Portable 12V Jump Start Device Powered By KrankingKAP Supercapacitors REV. A

Similar documents
INSTALLATION - OPERATION MANUAL. Revision of 01/2012

KAPower Starting Module (KSM) With Programmable Logic Controller (PLC)

Matson Jump Starter Operator s Manual

JUMP STARTER OPERATOR S MANUAL RA1900

900 PEAK AMP PORTABLE JUMP STARTER

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

User Guide IGD Series

Vehicle battery BATTERY WARNING SYMBOLS BATTERY CARE

IMPORTANT SAFETY INSTRUCTIONS

Owner s Manual & Safety Instructions

Spotlight 1,000,000 Power Series Cordless Rechargeable

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

MULTI-FUNCTION JUMP STARTER

BusPro Series Instruction Manual

Installation Power Management Unit Battery Cables and Battery Harness

FEATURES. Power Status and Charge Indicator: A red LED indicates the battery is charging and a green LED indicates the battery is fully charged.

Twin-Beam Spotlight 3,000,000 Power Series Corded Cordless Rechargeable

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

4 in 1 POWER STATION Model: 7226

INSTRUCTION MANUAL. BatteryMINDer. Model SCC515 Maintenance Charger- Solar Controller for use with 5 Watt and 15 Watt Solar Panels

OPERATING INSTRUCTIONS

QPET, QPETXU Battery Chargers

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

MB V 3-IN-1 JUMP STARTER WITH SPIRAL WOUND BATTERY

QSSE, QSSEX INDUSTRIAL Battery Chargers

BATTERY & STARTER ANALYSER (BSA-12) User Manual

SUPER PUMP OUT SYSTEM

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

CORDED CORDLESS RECHARGEABLE

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

300 Amp Battery Jumper

Operating Instructions & Parts Manual. Portable Power Supply & Jump Starter ! WARNING

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

WJS-1800 User Guide MINI JUMP STARTER. Portable Jump Start & Power Supply

Battery Booster Pack. Instruction Manual for P/N

LIBERATOR USER MANUAL

PSX-240 Enclosed Autotransformer Installation Manual

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

600 Amp Battery Jumper with Air Compressor

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

Operating Instructions

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

OWNER S MANUAL & WARRANTY INFORMATION IMPORTANT SAFETY INFORMATION, SAVE THESE INSTRUCTIONS

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

installation and operating instructions for the following xtreme Battery chargers:

INTELLIGENT BATTERY CHARGER/MAINTAINER

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

WJS-3500 User Guide MIGHTY JUMP STARTER. Portable Jump Start & Power Supply

USER GUIDE EMERGENCY JUMP STARTER PORTABLE POWER SUPPLY INTELLIBOOST ULTRA RG600 12V 600A REV 1.16B

12V CAR JUMP STARTER and portable power bank

Digital Intelligent Battery Charger OPERARATOR S MANUAL

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

INSTALLATION & OPERATION MANUAL

II DISTRIBUTION & SUBSTATION TYPE C

Cordless Sweeper. OWNER S MANUAL Model: CFT Volt DC. Made Exclusively for ALDI Inc. Batavia, IL.,

30 Amp Solar Charge Controller

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

ADI-125/750 ADI-125/1500 ADI-125/2500

Go Power! Manual. GP-Smart Charger

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

SP6. Automatic Battery Charger. Model

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

Jumpbox Model SP-12V1500-JB1

Operating and Installation Instructions

Lemania/EnergyFlo Start booster X7

CLEAN POWER TM CPS Series Operator s Manual

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

WARNINGS, CAUTIONS AND NOTES

User Manual HomeGrid 5000 HD

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER BATTERY CHARGER! For your personal safety read, understand and follow the information provided in

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

O W N E R ' S M A N U A L

VTC1000 Series Voltage Converter. Installation & Operation Manual

Battery Jump Pack. Instruction Manual for P/N Lithium Iron Phosphate (LiFePO4)

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

44,400mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

40 V LITHIUM-ION BATTERY ATTACH YOUR RECEIPT HERE AB13786C 1. kobalttools.com ITEM # /

Instructions for use Attention

Battery Capacity Analyzer

OBE, OBEXU, ON BOARD Battery Chargers

Power Beam 20MCP Searchlight with 12 LED Area Light and Vehicle Jump Starter. Instruction Manual

OBAE, OBAEXU, ON BOARD Battery Chargers

Instructions for use

Models: SP3, SPSS3 Automatic Battery Charger

DC to DC Step Up Converter Model: VTC305

Cruising Charger Series OWNER S MANUAL

C3 Operating Instructions

1.5W Solar Panel. Owner s Manual

POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL

Transcription:

KrankingKART Mini HD Portable 12V Jump Start Device Powered By KrankingKAP Supercapacitors REV. A Protected by one or more of the following U.S. Patents US 6,819,010 B2 US 6,871,625,B1 US 6,988,475 B2

KrankingKART Mini HD Introduction. The patented KBI KrankingKART Mini HD jump start device is capable of delivering large amounts of power to start cars, light trucks, ATV s, boats, lawn equipment, and most other 12 Volt powered equipment. Identifications: Digital Voltage Guage Reverse Polarity Indicator Activation and Voltage Check Switch Boost Button For Emergency Recharge All Features Are Waterproof Built In Safety Device Will Not Activate If Connect In Reverse Polarity Or Connected To Incorrect Voltage Source Heavy Duty Solid Copper 900 Amp Booster Clamps Rocker switch position functions: Center or Nuetral Postition = Off Up = On or Starting Mode Press and hold down = Momentary Voltage Check

KrankingKART Mini HD Unique Features. Maintenance Free Built heavy duty for harsh environments Unique patented design Unparalleled Power and Reliability Cycle life upwards of 1,000,000 cycles Recharge to 100% in as little as 30 seconds Performance unaffected by cold temperatures Extremely long life regardless of storage voltages Weighs up to 60% less than lead acid battery alternatives Water proof, built using IP67 components Can sit unused for months and still start engines Recharges off any running vehicle, never needs to be plugged in Made in the U.S.A. ALWAYS WEAR EYE PROTECTION (WEAR SAFETY GLASSES) WHEN USING AND WHEN WORKING AROUND BATTERIES. NONCOMPLIANCE WITH THE REQUIREMENTS SET FORTH IN THIS MANUAL MAY RESULT IN DEVICE FAILURE OR FAILURE OF THE SUPERCAPACITOR WITHIN THE DEVICE.

Use your jump start device safely. WARNINGS AND CAUTIONS THIS DEVICE IS POWERED BY A SUPERCAPACITOR. THIS CAPACITOR OR CAPACITORS ARE VERY POWERFUL AND SHOULD BE TREATED WITH RESPECT. FOR THIS REASON WE ISSUE THE FOLLOWING WARNINGS AND CAUTIONS. Do not short circuit the cable clamps. Short circuiting of the clamps may result in burning or igniting of combustible materials adjacent to the point of short circuit. In case of an accidental short circuit it is necessary to disconnect the clamps immediately from the electrical circuit taking relevant safety measures. Do not touch the clamps to any conductive material. Do not use the device if any cable clamp or cord is damaged. Do not use the jump start device on a damaged or broken battery. Do not attempt to repair the unit or replace parts. Unauthorized repairs will void your warranty. If your KrankingKART Mini HD requires service, follow the directions in the warranty section or contact Kold-Ban International, Ltd.. Check vehicle battery terminals on the battery being jump started before using the power pack. If needed clean the battery terminals. After approximately 10 seconds of continuous cranking, if the disabled vehicle fails to start, stop and wait for 1 minute. This prevents damage to your vehicle s system. Avoid storing in direct sunlight, in extreme heat, or very moist areas. Never attempt to jump start a battery with frozen electrolyte. A frozen battery could explode from applying a charge. If the battery being jump started is less than 2V check battery prior to proceeding since the battery may no longer be in working condition. When LED is GREEN, unit is active. When LED is Orange, unit is on. Do not disassemble unit. Do not open unit up. Never operate MINI HD if unit is damaged.

12 Volt use ONLY. Use in well vented area. Read owner s manual before using. Contact with battery acid may cause severe burns and blindness. Failure to follow these instructions may result in personal injury, destruction of the jump starter, or damage to your vehicle. ALWAYS WEAR EYE PROTECTION (WEAR SAFETY GLASSES) WHEN USING AND WHEN WORKING AROUND BATTERIES. WARNING Risk of Explosion or Fire (ALL BATTERIES can release hydrogen gas that is explosive and/or flammable). KrankingKART Mini HD jump start procedures. Before using the jump start device it should be charged. Unlike ordinary battery powered jump start devices, the Mini can be charged with as little as 10V and still provide enough power to start an engine. Differences in engine size, engine oils, parasitic loads, and temperature may affect the amount of charge needed. As a result, until you become familiar with the Mini s charge characteristics for your application, it is recommend to charge the device prior to use. In most cases the charge process will take place between 90 and 180 seconds. If more than 5 minutes pass with the unit active, the unit will automatically shut off and enter sleep mode. If the unit is left in ON position longer than 10 minutes, the device will enter sleep mode. To wake from sleep mode press the boost button, or the activation switch down. To charge the KrankingKART Mini HD using a running vehicle: 1. BE SURE the jump starter switch is in the OFF position. 2. Open the hood of a running vehicle and locate the battery. 3. Connect the RED POSITIVE (+) clamp to the POSITIVE terminal first, then connect the BLACK NEGATIVE (-) clamp to NEGATIVE terminal. 4. If you accidentally connected the clamps backwards a warning LED will light RED. If the warning LED is lit RED, DISCONNECT THE CLAMPS IMMEDIATELY. DO NOT TURN THE JUMP STARTER ON. The unit has safety features to prevent activation in this scenario, but care should be taken to avoid this scenario. 5. Turn the device ON using the switch on the jump starter. LED should illuminate green. If the LED is ORANGE, press and hold boost button to recharge.

To charge the KrankingKART Mini using a running vehicle (continued): 6. Wait 90 to 180 seconds. After 90 to 180 seconds the jump starter should be charged. 7. The digital voltage display will indicate charge level. 8. Turn the jump starter OFF. 9. After turning the jump starter OFF disconnect the jump starter clamps. The BLACK NEGATIVE (-) first then the RED POSITIVE (+). Be sure the jump starter is in the OFF position before disconnecting the clamps. Failure to do so could cause damage. 10. The KrankingKART Mini HD is now ready for use. Notes about charging. 1. If more than 5 minutes pass with the unit active, the unit will automatically shut off and enter sleep mode. If the unit is left in ON position longer than 10 minutes, the device will enter sleep mode. 2. Different Vehicles may provide different levels of maximum charge. This is because the unit can only charge up to the system voltage of the vehicle used to recharge it. 3. The device may be charged to a maximum of 16V. Do NOT charge the device to a voltage greater than 16V. Irreversible damage and safety issues may occur. 4. Charging methods may vary. As a result, use common sense, use safety measures, and adhere to warnings & cautions at all times. ALWAYS WEAR EYE PROTECTION (WEAR SAFETY GLASSES) WHEN USING AND WHEN WORKING AROUND BATTERIES. USE COMMON SENSE, USE SAFETY MEASURES, AND ADHERE TO WARINGS & CAUTIONS AT ALL TIMES.

To jump start a vehicle or engine: 1. Turn the ignition key to the OFF position and remove the key before connecting clamps to the vehicle battery. 2. Be sure the jump starter switch is in the OFF position before the clamps are connected to the battery. 3. Connect the RED POSITIVE (+) clamp to the POSITIVE terminal first, then connect the BLACK NEGATIVE (-) clamp to NEGATIVE terminal. 4. If you accidentally connected the clamps backwards a warning LED will light RED and the unit will disable itself. If the warning LED is lit RED, DISCONNECT THE CLAMPS IMMEDIATELY. DO NOT TURN THE JUMP STARTER ON, this could cause serious damage, or injury. Reverse the clamp connections and the warning LED light should turn off and stop. 5. Turn the device ON using the switch on the jump starter. LED should illuminate green. If LED is Orange the boost button must be held in during start attempt. The less time between switching the device on and engine starting the better. 6. Start the engine. After starting the engine leave the jump starter attached for approximately 3 minutes, or until unit has reached system voltage. This will insure the jump starter is fully charged for its next use. 7. After 3 minutes turn the jump starter OFF. This is done by turning the switch back to the OFF position. 8. After turning the jump starter OFF disconnect the jump starter clamps. The BLACK NEGATIVE (-) first then the RED POSITIVE (+). Be sure the jump starter is in the OFF position before disconnecting the clamps. Failure to do so could cause damage. 9. The KrankingKART Mini is now ready to be used again, or to be placed in storage. If LED is RED after connecting cables: 1. Unit may be hooked up backwards (reverse polarity scenario). Check to make sure unit is correctly attached to battery terminals. Follow instruction number 3 from list above. 2. System voltage could be above 16 volts. In this scenario LED will remain RED, and the unit will not activate. Designed to work with 12 volt vehicles only.

Frequently asked questions. What kind of battery is in this device? The device does not contain a battery. It contains a Supercapacitor. How is an Supercapacitor different than a battery? An Supercapacitor contains NO LEAD. Unlike a battery, a Supercapacitor stores and releases energy using a physical process not a chemical process like a battery. As a result, it does not suffer any of the drawbacks associated with lead acid batteries. What are some of the advantages a Supercapacitor has over a battery? Maintenance Free Unparalleled Power and Reliability Cycle life upwards of 1,000,000 cycles Recharge to 100% in as little as 30 seconds Extremely long life regardless of storage voltages Weighs up to 60% less than lead acid battery alternatives What are some of the disadvantages a Supercapacitor has over a battery? Supercapacitors are capable of large amounts of power but not energy. As a result, Supercapacitors are not a good replacement for batteries running energy demanding loads. What is the difference between power and energy? Power is how much can I give something. I.e.: Starting an engine requires a lot of power but only for a short duration. Energy is how long can I run something. I.e.: Running a radio, fan, or refrigerator overnight. This requires a small amount of power but a large amount of energy. How long will the device hold a charge? On average the device should hold a charge between 3 and 4 weeks. What happens if the voltage in the device is very low or reaches zero volts? Nothing, just simply recharge the device. Storing the device at low voltages does not effect its performance or life. Unlike battery powered devices, you do not have to keep the device constantly charged above a set voltage. Why does the device shut off on its own? If more than 5 minutes pass with the unit connected to a vehicle, the unit will automatically shut off and enter sleep mode. If the unit is left in ON position longer than 10 minutes, the device will enter sleep mode. To wake from sleep mode press the activation switch down. What should I do to maintain the device? Nothing except keep the cables and device in clean working order. Avoid storing in direct sunlight, in extreme heat, or very moist areas.

How can the device crank and engine with as little as 10V? The internal resistance inside a Supercapacitor is so much less than a lead acid battery that it can release its power more efficiently than a lead acid battery. Therefore, an engine starter, in most cases can effectively use the power with as little as 10V. I keep recharging the device but the voltage seems to drop off quickly? This is normal. There is a balancing circuit in the device that causes the voltage to drop as the Supercapacitor cells charge and balance between themselves. The voltage drop will be high at first and then slow down once the cells get synchronized. I am trying to use the device but nothing seems to be working. What am I doing wrong? In most cases there is insufficient charge in the device. Charge the device and try again. If still nothing, than call our help line. I am positive something is wrong, can I open unit up to fix it myself? In most cases there is insufficient charge in the device. Charge the device and try again. If still nothing, than call our help line. Where can I obtain help or service? Call Kold-Ban International, Ltd. For help or service. 1-800-527-8278 or 1-847-658-8561. Notes:

Supercapacitor contents. This capacitor is a manufactured electronic product that contains primarily non-hazardous materials, including metal and plastic. Supercapacitors are sealed, metal containers (steel or aluminum) which enclose layers of activated carbon which is saturated by an electrolyte solution, aluminum and plastic. The electrolyte solution contains a quaternary salt compound (tetraethyl aluminum tetrafluoroborate) dissolved in the solvent acetonitrile. The assembled layers are inserted into the outer metal container and are saturated with the electrolyte, sealed and stored in an uncharged state. There are minor hazards that can arise from exposure to the activated carbon. If the contents of these Supercapacitors remain sealed in the outer shell and they are kept uncharged, persons handling this product will avoid most of the risks described herein* for all hazardous components of the electrolyte. As such, precautions should be taken to avoid rupture or overheating the sealed metal containers. * herein describes and refers to the Material Data Safety Sheet (MSDS). ** The MSDS can be downloaded from the information center area of KBI s website. www.koldban.com If you are not able to download the MSDS sheet, a MSDS sheet can be faxed, mailed, or emailed by calling Kold-Ban International, Ltd. directly at 1-800-527-8278 or 1-847-658-8561. Dispose of properly by recycling. Call KBI 1-800-527-8278 or 1-847-658-8861

THIS PAGE INTENTIONALLY LEFT BLANK

Limited warranty: The Supercapacitor contained in the device is warranty for a period of three (3) years. All other components fall under the warranty described below. KBI products are warranted to the original purchaser against failure due to defective material and/or workmanship for a period of one (1) year from the date of purchase except when a variance is expressly stated in the Owners Manual. This warranty does not cover any product worn out or altered, used for a purpose other than for which it is intended, or used in a manner inconsistent with any instructions regarding its use. The exclusive remedy for any product found to be defective under this warranty is limited to the repair or replacement of the defective product without charge, and KBI shall not be liable for any consequential or incidental damages, including labor charges. In order to qualify for this warranty, the alleged defective product must be returned directly to the KBI factory (or authorized Service Center), postage or freight prepaid. Before the product is returned, a Return Material Authorization (RMA) number must be issued. Call KBI for a RMA number. Final determination of defects will be made by KBI in accordance with procedures established by KBI. No agent, employee, or representative of KBI has any authority to bind to any affirmation representation, or warranty concerning KBI Products, except as stated herein. See comprehensive policy for complete details. Kold-Ban International, Ltd. 8390 Pingree Rd. Lake In The Hills, IL 60156 P: 800-527-8278 or 847-658-8561 F: 847-658-9280 www.koldban.com KbI form 131406 2016 Kold-Ban International, Ltd. Protected By One Or More Of The Following Patents: US 6,819,010,B2 US 6,871,625,B1 US 6,988,475 B2