Harbor Light Model HL General Specifications

Similar documents
Lighthouse Power Pedestals,

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Newport Harbor Mate Utility Center

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Marina Power and Lighting, Inc. General Specifications for the Newport Harbor Mate

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

General Specifications for Lighthouse Power Pedestal

Anchorage SS Center Model AN3050. Installation, Maintenance, and Operation Manual

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

Marina Mate SS Model MMSS2050 Installation, Maintenance, and Operation Manual

Harbor Light SS Model HLSS Installation, Maintenance, and Operation Manual

Marina Mate SS Model MMSS2050. Installation, Maintenance, and Operation Manual

Fire Station Hose Rack Model FSHR Installation, Maintenance, and Operation Manual

Installation, Maintenance, and Operation Manual

GTX UNIT SUBSTATION Installation, Maintenance & Operation Manual

RV Park Equipment Product Focus. Power Pedestals Distribution Equipment

Installation Instructions for Admiral Power Pedestal (# )

Installation Instructions for Lighthouse SS Power Pedestal Rev. 3 5/20/14

! WARNING! WARNING. Dock Boxes Unlimited, Inc. strongly recommends that these products be installed by a qualified electrician.

Beginner's Guide to Marinas, RV Parks, and NEC Requirements for Both

Marina Power and Lighting Product Focus. Power Pedestals Distribution Equipment

POOL BARON Nicheless Color Changing LED Pool Light

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Marina Power and Lighting Equipment. Product Focus. Power Pedestals Distribution Equipment. High-Quality, Weatherproof Electrical Equipment

Every accessory for today s dock......except the boat. Version 08

Level One Electric Vehicle Charging Station Wall Mount Product Guide

Power Pedestals. 6.1 Introduction Product Description... 2 Application Description... 2 Optional Features... 2

Installation Manual. For. PWC 3000 Boat Lifts

6.1 Introduction Product Description... Application Description... Optional Features...

Power Pedestals. 5.1 Introduction Product Description... Application Description... Optional Features...

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts

A. Submit manufacturer's literature and technical data before starting work.

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts

Recreational Vehicle Park Electrical Products & Accessories

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

Bussmann series Quik-Spec Coordination Panelboard

SV10 LED. The US manufactured SV10 LED is. SV10 LED technical specifications

WattStation Wall Mount User Manual

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Project: Type: Qty: QH2L. Options QH2L 27 3 /8" 23 3 /16" 3 1 /2" O.D. Pole. Options

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

CHAPTER V RESIDENTIAL WIRING

Pow-R-Line 3E Panelboard

South Dock Replacement Prescott Park. This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement Prescott Park.

Installation Manual & Warranty

BUSWAY Low Voltage (Pow-R-Flex)

4400JF (120V) Aerating Fountain Specifications

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

SEA PORT MARINE CORP.

Generator Fire Safety: Generator assemblies should be located outside the building.

Marina Power & Lighting Capabilities Brochure

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

24 KVA International Universal IsoTransformer

East Central College

Solar Combiner Solutions

Spring Test 10 due 05/11/2013

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved.

3.6 KVA IsoG2. INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model 93-ISOG26-A LT ISOG26 1. Issue 1 Print 3 SHORELINE ISOLATION TRANSFORMER

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Volume 1 Residential and Light Commercial CA E December

APPENDIX B: LISTS OF APPROVED MATERIALS

Instrument Enclosure Assemblies

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

MIL-24/2600Q MIL-24/3200DQ

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Quik-Spec Coordination Panelboard Specifications

OWNERS MANUAL JANUARY 2007 ISO

8400JF (240V Single Phase) Aerating Fountain Specifications

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

Quik-Spec Electrical Gear

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

INSTALLATION INSTRUCTIONS

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

3.8 KVA IsoG2. INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model 93-ISOG2/8-A LT-ISOG28-1. Issue 1 Print 3 SHORELINE ISOLATION TRANSFORMER

3.6 KVA IsoGuard. INSTALLATION INSTRUCTIONS & OWNER S MANUAL Model 93 IXFMR3/6N A LT IXFMR36N 1. Issue 1 Print 1 SHORELINE ISOLATION TRANSFORMER

Accessories. Robust, watertight plug connectors For vertical and horizontal mounting. Application For inside and outside (-30 C to +130 C)

MN/DOT Specification Light Emitting Diode (LED) Luminaire 03/20/2012

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

CON EDISON EQUIPMENT

PRODUCT/SERVICE CLASSIFICATION CLASS 285 ELECTRICAL EQUIPMENT AND SUPPLIES (EXCEPT CABLE AND WIRE)

Electrical Wiring Practices

use pulldowns to assign fixture # to arm locations: K K K 14W LED 27W LED 1 Full-Cutoff optics

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Expense Report. spare muffin fans 29% ventilation 47.48% latch & cement board 23.05%

Weather Protective Devices

Vandal Resistant Ringdown/Autodialer Telephone

DC to AC Power Inverters

DC to AC Power Inverters

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

1000 Watt Metal Halide Light - Class 1 Division 2 Groups A-D - T3b Temperature - 110,000 lumens

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Operating Instructions

Operating Instructions Series L 4000 Spring Driven Cord Reels

Connectors and Insulators

Transcription:

Harbor Light Model HL30100 General Specifications Rev.5 02-02-17 Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 Toll Free: 1-855-258-3939 Fax: 1-757-258-3988

ALL HARBOR LIGHT POWER PEDESTALS SHALL MEET THE FOLLOWING SPECIFICATIONS: SECTION A: ACCEPTABLE MANUFACTURERS: Marina Electrical Equipment, Inc. 100 Warwick Court Williamsburg, VA 23185 Toll Free: 1-855-258-3939 Web: www.marinaelectricalequipment.com SECTION B: GENERAL REQUIREMENTS 1. Power pedestal shall be listed and marked, tested and certified to conform to Standard ANSI/UL 231 entitled Power Outlets and CAN/CSA Standard C22.2 No. 29 entitled Panelboards and Enclosed Panelboards. 2. Shall be compliant with all sections of the latest edition of NFPA 303, Fire Protection Standards for Marinas and Boatyards. 3. Shall be compliant with NEC, and NFPA 70 406.8 (B)(2)(a), which states: A receptacle installed in a wet location shall be installed in a weatherproof enclosure, the integrity of which is not affected when the attachment plug cap is inserted. SECTION C: CONSTRUCTION REQUIREMENTS 1. All materials and components used in the construction of the power pedestal shall be listed. 2. Main Housing: Shall be constructed of 3/16 thick injection-molded listed polycarbonate and shall be painted with a UV-resistant 2-part polyurethane coating and be listed as a Type 3R weatherproof enclosure. The housing shall pivot at the mid-section to provide access to the terminal block assembly. 3. Access Panels: Shall be constructed of 3/16 thick injection-molded listed polycarbonate, painted with a UV-resistant 2-part polyurethane coating, and be flush -mounted. 4. Top: Shall be constructed of 3/16 thick injection-molded listed polycarbonate and shall be covered with a UV-resistant 2-part polyurethane coating. 5. Lens: Shall be constructed of 3/16 thick injection-molded listed clear or amber-colored polycarbonate. 6. Mounting Base: Shall be constructed of 1/4" thick injection-molded polycarbonate and isolate the bottom of the pedestal housing from the mounting surface to shield against the corrosive effects of concrete and pressure-treated wood decking. The base shall include a non-metallic gland plate designed to prevent the intrusion of water and other items into the unit after installation. 7. Hardware: Shall be stainless steel, Phillips drive. SECTION D: LIGHTING 1. Each power pedestal shall contain a non-metered lighting assembly. 2. Lighting assembly shall be a readily available, commercially manufactured LED that is controlled by an electromechanical photocell. Optional helical compact fluorescent bulbs are also available. 3. The electromechanical photocell shall be internally mounted with no exposed external components. 4. Lighting assembly shall be protected by a 20 ampere, single pole circuit breaker or fuse. 5. Standard lighting assembly shall provide 360 downward illumination and provide minimum dock lighting of one foot-candle at 15 feet and not interfere with boater navigation. SECTION E: RECEPTACLES & CIRCUIT BREAKERS 1. Receptacles shall be corrosion-resistant, locking grounding type conforming to L5-20R, L5-30R, SS2-50R and/or SS1-50R requirements and are rated for marine ship-to-shore use. 2. receptacles shall be Leviton corrosion-resistant stainless steel or equivalent. 3. IEC/CEE pin-and-sleeve receptacles shall be ABL-Sursum, Globetron or equivalent. 4. Ground Fault Circuit Interrupting (GFCI) receptacles shall conform to 5-20R requirements. 5. GFCI Receptacles shall be Leviton SmartLockPro Weather Resistant, corrosion-resistant stainless steel or equivalent. 6. Receptacles shall be mounted at a minimum height of 30 above the deck surface and at a minimum angle of 35 from horizontal for ship-to-shore power cord strain relief. 7. Each receptacle shall be individually protected by a thermal-magnetic type circuit breaker with 10 kaic interrupting rating. Rev.5 02-02-17 Page 1

SECTION E: RECEPTACLES & CIRCUIT BREAKERS (cont.) 8. Circuit breakers shall be miniature molded case type as manufactured by Square-D, GE, EATON or equivalent and mounted vertically to avoid water accumulation on or around the circuit breaker. 9. Circuit breakers and twistlock receptacles shall be assembled together on a panel section which can pivot out as a single mechanism for simplified maintenance practices. 10.Circuit breakers and receptacles shall be covered by a hinged weatherproof lockable door which must latch closed with or without the plugs and ship-to-shore power cords attached. 11.GFCI receptacles shall be covered by the same hinged weatherproof lockable door, which complies with NEC Article 406.9 (B)(1), which states: 15 and 20 ampere, 125V and 250V receptacles installed in wet locations shall have an enclosure that is weatherproof whether or not the attachment plug is inserted. SECTION F: SOLID-STATE ELECTRIC kwh MONITORING (OPTIONAL) 1. Each pedestal shall be equipped with solid-state electric monitors which output kilowatt-hours (kwh) consumption at each slip via an electromechanical counter and internally built wireless remote transmission. Wireless transmission shall be integral to the solid state electric monitor. Transmission via third-party vendors is not acceptable. 2. Each solid-state electric monitor shall be rated for 200 amperes, listed, marked and tested to conform to Standard ANSI-C12.1 and NTEP standards with ±1% accuracy. 3. Each solid-state electric monitor shall be capable of monitoring ground faults at each slip. 4. Each solid-state electric monitor shall measure the analog pulse output of the water meters at each slip and wirelessly transmit the gallon usage via the internally built wireless remote transmission. Wireless transmission via thrid-party vendors is not acceptable. SECTION G: WIRING & TERMINAL BLOCK 1. Power pedestal shall be completely factory pre-wired to the load side of the copper 3/8 stud lug compression terminal block assembly. 2. Electrical wiring shall be high-stranding tin-plated copper THHW/MTW VW-1 Boat Cable rated for 105 C. 3. LOAD side terminations to the copper bus bar shall be made by compression-type ring terminals on 3/8-16 stainless steel stud with stainless steel 3/8 x 3/4" O.D. flat washer, 3/8 stainless steel Belleville captive spring washer and 3/8-16 silicone-bronze hex nut, torqued to 180 inch-pounds. 4. LINE side terminations to the copper bus bar shall be made by compression-type ring terminals on 3/8-16 stainless steel stud with a stainless steel 3/8" split-ring lock washer and 3/8-16 silicone-bronze hex nut. Maximum wiring size shall be maximum 4/0 AWG for loop feeding and 350 kcmil for direct feed. 5. Maximum standard terminal block load shall not exceed 250 amperes at 125/250VAC or 277/480 VAC. 6. All electrical components shall be located above the electrical datum plane set forth by the NEC. 7. All exposed metallic parts shall be grounded as part of the integral equipment ground. SECTION H: TELEPHONE, CABLE TELEVISION, INTERNET (OPTIONAL) 1. Power pedestals shall be capable of providing single and/or dual telephone (RJ-11), cable television (F), and internet (RJ-45) connectors. 2. Low voltage telephone, cable television, and internet connections must be mounted under a weatherproof protective cover. SECTION I: PLUMBING (OPTIONAL) 1. Each pedestal shall be capable of providing single or dual 3/4" IPS stainless steel ball valve hose bibs. 2. Plumbing connections must be partitioned from all electrical wiring/components by an integral partition box. 3. Each ball valve hose bib shall be metered (with or without analog display at at the pedestal) and have the gallon per slip usage wirelessly transmitted via an internally built wireless remote transmitter that is integral to the monitor. Wireless transmission via third-party vendors is not acceptable. SECTION J: HOSE/CABLE BRACKETS 1. Each pedestal shall be equipped with brackets capable of holding 50 feet of standard 5/8 I.D. garden hose, or 50 feet of 50 ampere, 4-wire shorepower (S.O.) cord. END OF SECTION Rev.5 02-02-17 Page 2

42.5" RECEPTACLES / CIRCUIT BREAKERS UNDER WEATHERPROOF COVER HOSE / CABLE BRACKET LED LIGHT w/ PHOTOCELL TERMINAL BLOCK ACCESSED BY PIVOTING TOP HALF DOWNWARD PIVOTING FACEPLATE ASSEMBLY FOR SIMPLIFIED MAINTENANCE HL013600 POLYCARBONATE HOUSING 3/4" WATER VALVE REMOVABLE WATER ACCESS PLATE SIDE VIEW SIDE VIEW SIDE VIEW w/ TOP HALF PIVOTED FOR ACCESS TO 250A TERMINAL BLOCK Ø.50" (TYP.) PLACE MAIN HOUSING OVER THE MOUNTING BASE AND SECURE WITH THE EIGHT (8) #10 x 3/4" STAINLESS STEEL SCREWS PROVIDED. HINGE TO TILT UNIT OVER FOR TERMINAL BLOCK ACCESS WATER FEED AREA ELECTRICAL FEED AREA (5.50" x 5.50") WATER FEED AREA 2.00" TYP. 2.00" MOUNTING BASE PLATE w/ NON-METALLIC GLAND PLATE 8.25" MOUNTING BASE DETAIL Rev.5 02-02-17 Page 3

LED LIGHT 5-20R SS2-50R PHOTO CELL L5-30R THERMAL / MAGNETIC TYPE CIRCUIT BREAKERS LIGHT RECEPTACLES GROUND LUG MOUNTED TO STAINLESS STEEL HOUSING CIRCUIT BREAKERS COMMUNICATIONS LINE 1 NEUTRAL LINE 2 GROUND LINE 3 MEE TERMINAL BLOCK SIDE VIEW w/ RECEPTACLE DOOR OPEN AND TOP REMOVED TYPICAL WIRING DIAGRAM SECTION K: WARRANTY 1. The main housing and attached parts (top, lens, doors, receptacle faceplates, circuit breaker plates, and mounting base plate) will be free from failure resulting from defects in material and/or workmanship, and are covered by a limited warranty of one (1) year. The warranty is voided if any petroleum-based solvent is used anywhere on or near any of the polycarbonate parts. These parts include: the top, lens, doors, receptacle faceplates, circuit breaker plates, and the mounting base plate. 2. Internal electrical components shall be covered by a limited warranty of one (1) year. Items covered include: receptacles, circuit breakers, photocells, lamp holders, coil transformers, counters and wiring harnesses. 3. The solid-state electric kwh monitors will be free from failure resulting from defects in material and/or workmanship, and are covered for one (1) year. The warranty shall not cover the product against severe over-voltage conditions such as lightning strikes or excessive utility surges. The warranty is voided if the factory seal is broken or manipulated. 4. The warranty policy does not cover damage or failure resulting from abuse, misuse, negligence or Force Majeure. Specifications Subject to Change Without Notice END OF SECTION Rev.5 02-02-17 Page 4