Pneumatic Actuator Durastroke Series 2000 Installation & Maintenance Instructions

Similar documents
Pneumatic Actuator Durastroke Series Installation & Maintenance Instructions

Fisher 657 Diaphragm Actuator Sizes and 87

MODEL 5540 CONTENTS. Installation, Operation and Maintenance Instructions 1.0 GENERAL

Baumann Series Flexsleev Control Valve Instructions

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators

IOM Manual. IOM Manual. Series 20/21.

Globe type control valve

Technical Manual MSI Hydraulic Adjustable Choke

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions

Baumann Sanitary Diaphragm Angle and Inline Control Valve

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Property of American Airlines

Powers Controls No. 6 Damper Actuators Tandem Mounting

Fisher 2052 Diaphragm Rotary Actuator

Installation, Operation and Maintenance Instructions

CUSTOM COMBINATION AIR VALVE

Type 657 Diaphragm Actuator Sizes and 87

VALVE AND PLUMBING KIT INSTRUCTIONS SMC 84Q & 2408 LOADERS NEW HOLLAND TRACTORS MODEL 2WD 4WD LESS CAB WITH CAB 1720 X X X 1920 X X X

INSTALLATION MANUAL. MB-180, MB-210 and MB-210L Motor Brake INSTALLATION. Force Control Industries, Inc. DESCRIPTION OPERATION

KIT INSTALLATION INSTRUCTION

MODEL DESCRIPTION IN LBS.

Model DFR 070/156/220 Rotary Actuator

Fisher 1061 Pneumatic Piston Rotary Actuator with Style F & G Mounting Adaptations

Fisher D4 Control Valve Assembly

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division

Baumann Sanitary Control Valve

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

Series 9000 Control Valves RESEARCH Control Valves

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

VALVE AND PLUMBING KIT 2409 LOADER CUB CADET & KIOTI TRACTORS


Fisher 1052 Size 70 Diaphragm Rotary Actuator

Sanitary Design Control Valves V972. Instruction Manual. Installation & Maintenance instructions for W.Arthur Fisher V972 series control valves

Baumann Way Control Valve

IBT Series Square Drive Torque Wrenches

PremAire Cadet Escape Respirator: Second Stage Regulator

Nor East. Instructions. Safety Messages. Inspection. Parts Nor East Controls. Service. Type 05 Air-O-Motor Actuator Used With Globe Valves

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm

Mixer Discharge Door Adjustment on models; 30, 42, 54, 81, 108, 135 mixers.

ASSEMBLY MANUAL. Keep With Operator s Manual

J Flow Controls Model Numbering

Type 3660 and 3661 Positioners

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

HexPro Series Low Profile Wrenches

VALVE AND PLUMBING KIT 2408TL LOADER AGCO & MASSEY FERGUSON TRACTORS

CVS Type 657 Diaphragm Actuator Sizes 30-70

Firehawk Second Stage Regulator Fire Service

TECHNICAL INSTRUCTIONS Heavy Duty Bronze Series

Masoneilan Instruction Manual for VariPak Series

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Low Profile Wrenches Operation and Maintenance Manual

ZICO 3094PM1. Model VS REV Retracted. Extended

Fisher 3024C Diaphragm Actuator

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

TRENCH & CLAY DIGGERS

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Type 1051 and 1052 Diaphragm Rotary Actuators

VALVE AND PLUMBING KIT NEW HOLLAND 7310 LOADER NEW HOLLAND TRACTORS

Baumann Little Scotty Bronze Control Valve

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL


AV-497. Application. Features. Valve Linkage for MK-6811 and MK-6911 General Instructions

INSTALLATION INSTRUCTIONS Auto Level Compressor Kit IMPORTANT NOTES

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

SkidPro. Hydraulic Snow Blade/Pusher Combo OWNERS/OPERATORS MANUAL. Model Number HSBP.

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

Fisher TBX Hydro Plug Fixture


Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division

HD Series. Pilot-Operated Regulating Valves. HD Series features & benefits

VG7000 Valve Linkage for M100 Series Motor Actuators

Fisher CVX Hydro Plug Fixture

ANDCO Eagle Actuator Instruction Manual

INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Fisher 585C Series Piston Actuators

THE GLIDER 5th Wheel Attachment

Fisher 667NS Diaphragm Actuators Size 40, 45, 70, and 80

LS200, LS200N, LS200NDVOR Series and L1100 Liquid Level Switches

Bettis M11 Manual Hydraulic Override System Operating Instructions for HD, T, and G Series Pneumatic and Hydraulic Actuators

Wastewater Air Release Valve Models 48A, 49A

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Type 1051 and 1052 Diaphragm Rotary Actuators

Installation, Operation & Maintenance Instructions

Installation Instructions

LEVEL CONTROLS 313 IOM

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

Model DF233 Control Valve

Operation and Maintenance Manual

Oil Control Handle with Mechanical Meter. Introduction. General Information. Important Information 3575-A 3575-B 3575-C 3575-D

B o d y S t r u c t u r e

Model DF269 Control Valve

SECTION CONTROL VALVE ACTUATORS

ASSEMBLY MANUAL SMC 2491 LOADER VALVE AND PLUMBING KIT INSTRUCTIONS KUBOTA TRACTORS

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS

Transcription:

Pneumatic Actuator Durastroke Series 2000 Installation & Maintenance Instructions INSTALLATION Installation of Airtech Products Durastroke pneumatic actuator is a simple three-step process; Mounting of the actuator & attachment to load, connection of air line and connection of the control signal. Before starting installation, inspect the actuator and contents of the shipping carton to ensure all required parts are present. Check the following: Ensure the positioner is firmly secured to the actuator body. Clevis is present at the end of travel stem? The following hardware kit was included:. Five (5) /- x ½ long bolts 2. Four () / lock washers. One () /- locking nut A) Mounting The Actuator:. The actuator can be mounted in either a vertical or horizontal position. 2. The actuator is supplied with four () / - bolt-holes in the bottom plate for attachment to a mounting plate or bracket.. A hole at least / (but not larger than diameter) must be provided in the center of the actuator mounting bolthole pattern for penetration of the actuator travel stem and clevis.. Attach the actuator to the mounting bracket with the four supplied / - x ½ bolts and lock washers. In a rotating pattern, tighten each to Ft-Lbs torque. 5. DO NOT ATTACH THE ACTUATOR TO THE TORQUE TUBE LEVER ARM YET. B) Air Line Connections:. Blow out all piping before connections are made to prevent dirt, chips, etc from entering the positioner. Ensure all air entering the positioner and actuator is clean, dry and oil free. Failure to do so increases the possibility of operational problems and/or deviation from specified performance. 2. Locate the / NPT ports on the Fisher DVC Positioner.. Install a / threaded adapter in the air inlet port. Use Teflon tape or a non-hardening sealant on the male threads of connectors.. Connect / or / air line to the supply port on the positioner. 25 psig is the suggested maximum total air pressure in this line. C) Control Signal Connection:. Locate the /2 NPT port for the conduit connection and install male adapter. 2. Connect conduit and thread wiring into transducer connection terminals. Connect leads for control signal to corresponding terminals in Positioner.. Securely reinstall cap. 550 S. st W. Avenue Tulsa, OK 727 Office: 9-2-02 Fax: 9-2-0270 www.airtechproducts.com

Durastroke 2000 Pneumatic Actuator Installation Instructions Page 2 of D) Connecting The Linkage:. In most cases**, the torque tube lever arm will be preset at the factory to drive the louver either Fail Open or Fail Closed upon loss of air and / or actuator retraction. As a result, connection of the linkage will be a simple matter of manually situating the louver blades and actuator stem to the correct position and then attaching the control link to the clevis (at the base of the actuator stem) and finally to the torque tube lever arm. To determine how the actuator and louver blades should be positioned, please note the following instructions: a. Fail Open Louvers Stroke actuator to fully extended and manually set louver to fully closed position before connecting louver lever arm & link to actuator clevis. b. Fail Closed Louvers Ensure actuator is completely retracted and manually set louvers to fully closed position before connecting louver lever arm & link to actuator clevis. 2. When all sections are installed and connected, stroke the actuator several times to ensure it moves the entire louver freely without binding or interference. On very large louvers with multiple sections, inspect to confirm all the sections are fully open and completely closing in unison. Some adjustment of end links or torque tube clamps may be required to ensure all louver blades open and shut consistently down the entire length or across the entire width of the louver.. Check all attachment fasteners to ensure all are properly tightened and completely engaged to the louver flange.. If applicable, check all end link connections and torque tube couplers to ensure they are properly tightened and fasteners are completely engaged. **For new orders only when the actuator is purchased in conjunction w/louvers. Please contact the factory for specific instructions on retrofit or other applications that did not see both the actuator and louver originate as simultaneous/concurrent Airtech orders

Durastroke 2000 Pneumatic Actuator Installation Instructions Page of MAINTENANCE Annual Inspection:. Inspect and verify all mechanical connections Positioner & mounting bracket bolting to actuator body o Check mounting bracket rigidity o Confirm actuator to mounting bracket bolt tightness Clevis general condition o Visually inspect overall clevis condition o Confirm fastener between clevis and actuator link is sound Link to torque tube lever arm o Visually inspect overall link condition o Confirm fastener between link and torque tube lever arm is sound Positioner attachment to actuator body o Visually inspect positioner for visible cracks or damage o Confirm positioner is securely fastened to actuator body 2. Inspect and verify all pneumatic and electrical connections Air connections to positioner o Supply line to threaded adapters o Adapters to positioner Diaphragm o Confirm pressure is present at Diaphragm Listen for leaks at stem Repair Kit & Recommended Spare Parts List The following items are recommended as a single actuator repair kit. It is suggested that one repair kit be kept on hand for each actuators on site and in service. Please note a repair & maintenance kit is not offered for the positioner because of the complexity of that particular item. Best practice is simply to replace a non-operational positioner. Item numbers noted below refer to Airtech Products, Inc. drawing, Durastroke 2000 Actuator. Item Number Description 2 Guide Bushing Snap Ring 9 Diaphragm Diaphragm Washer 5 O-Ring 25 Kit, Positioner, Fisher DVC 00 0-0-0

/" 2 27 2 29 2 2 0 20 7 0 2 9 9 5/" 5 2 2 25 9 5 2 /2" /" DIA AIRTECH PRODUCTS, INC. Dwg. Name: DURASTROKE 2000 ACTUATOR Date: By: /0/0 STEWART Customer: File #: AIR MOTOR

ITEM QTY. DESCRIPTION 2 5 7 9 0 2 5 7 9 20 2 2 2 25 2 27 2 29 0 2 CLEVIS GUIDE BUSHING LOWER HOUSING SNAP RING STEM HOUSING NUT, ESNA LOCKWASHER HOUSING SCREW DIAPHRAGM LOCKNUT DIAPHRAGM PLATE UPPER HOUSING DIAPHRAGM WASHER CONNECTOR NUT O-RING SPRING COVER SCREW SPRING ROD MAIN SPRING SPRING COVER SPRING WASHER WASHER HOUSING SCREW, / X / HOUSING NUT, / STD. GASKET POSITIONER, DVC 00 /" NPT FITTING LOCKWASHER COVER PLATE SCREW COVER PLATE WASHER LOCKNUT 2 SAE FLAT WASHER /" TUBING AIRTECH PRODUCTS, INC. Dwg. Name: DURASTROKE 2000 ACTUATOR Date: By: /0/0 STEWART Customer: File #: AIR MOTOR