BS EN ISO :2006

Similar documents
BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

EN 1154:1997 / A1:2002

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

Title: WF Report No: Prepared for: Simonswerk UK Ltd. Burcott Works, Spring Street, Tipton, West Midlands, DY4 8TF. Date: 20 th April 2012

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

Title: Fire resistance test in accordance with BS EN : 2008 on an uninsulated, face fixed rolling shutter doorset. Report No: Prepared for:

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES LOW PROFILE FIXED. Dominion Doors & Windows Ltd.

COMPUTER SIMULATION U-FACTOR, SHGC, VT PERFORMANCE EVALUATION OF FIXED WINDOW 3000 SERIES CASEMENT WINDOW. Dominion Doors & Windows Ltd.

Rayleigh Instruments Ltd Raytel House Brook Road Rayleigh Essex SS6 7XH United Kingdom

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145.

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: PARAMOUNT WINDOWS

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: CR LAURENCE CO., INC.

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY

WF Report No: Prepared for: Rohden UK Ltd Unit 2, Hayleys Manor Farm Upland Road, Epping Upland, Essex, CM16 6PQ. Date: Notified Body No:

Title: WF Report No:

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

PART XV Metering Systems SECTION 2 GUIDE TO GAS METERING SYSTEMS

Title: The Fire Resistance Performance of Modified Doorsets. WF Assessment Report No: Prepared for:

Kestrel Aluminium Systems Limited. Product Manual Section 14 Thermal Sliding Folding Door. Manual Version

AAMA THERMAL PERFORMANCE REPORT. Rendered to: TORO ALUMINUM. SERIES/MODEL: Commdoor 225 Awning (Project Out) TYPE: Projecting, Awning

The Heritage Stepped Door Technical Manual

Technical Document. Product Information and Test Reports for Fire Resistant Glass 2016 EDITION

AAMA THERMAL PERFORMANCE REPORT (Revised) Rendered to: UNITED STATES ALUMINUM

THE INSTITUTE OF PETROLEUM GUIDELINES FOR THE DESIGN AND PROTECTION OF PRESSURE SYSTEMS TO WITHSTAND SEVERE FIRES

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

Content. Thermal insulation

Test Report No.: SDHGR FM Date: Jun.08, 2012 Page 1 of 3

Evidence of Performance Burglar resistance

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

56 LESLIE HOUGH WAY SALFORD GREATER MANCHESTER M6 6AJ UNITED KINGDOM. Test Report EN : TA11/0004c.

Report No 2370/ This Report consists of 40 pages. Authority & date Request by Client dated 25 November 2010

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

SLIDING DOOR AND WINDOW SYSTEM WITH THERMAL BREAK

UK Weighing Federation Technical Articles

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

Understanding BS 1363 Amendment No.4

AAMA/WDMA/CSA 101/I.S.2/A440-08

H Window Company, LLC Super-insulating Windows and Doors th Avenue West Ashland WI Phone: Fax:

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

Title: Performance Requirements of Exterior Painted Parts

AAMA/WDMA/CSA 101/I.S.2/A440-08

Uw = 0.66W/m²K Uf = 0.77 W/m²K Ug = 0.50 W/m²K

European Fire Pump Listing

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

Article: Sulfur Testing VPS Quality Approach By Dr Sunil Kumar Laboratory Manager Fujairah, UAE

Australian/New Zealand Standard

Australian Standard. Uninterruptible power systems (UPS) Part 1.1: General and safety requirements for UPS used in operator access areas

TOPAS 2130A (Draft v3)

Luxury Window Designs

AAMA THERMAL PERFORMANCE REPORT. Rendered to: US ALUMINUM INC., DIVISION OF CR LAURENCE CO., INC.

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY

FrontGuard Steel Entrance Doors

EU RO Mutual Recognition Technical Requirements

Mondrian CWS-50 Slim Product Information Sheet

COMMISSION REGULATION (EU)

CRL PREMIUM SERIES BALANCED DOOR

Single action, hinged

EC Type-Approval Certificate UK2853 Revision 4

CRL PREMIUM SERIES BALANCED DOOR

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: EARTHWISE GROUP, L.L.C

Executive Summary. The testing was conducted with the following steps in order to evaluate the tyre pressure decay.

NCC Leisure Battery Verification Scheme. Leisure Accommodation Vehicles

Fire resistance test in accordance with BS 476 Perko (R1, R2 & R21) and Perkomatic (R85) concealed door closers

PERFORMANCE TEST REPORT. Rendered to: AIR VENT, INC. SERIES/MODEL: Hip Ridge Vent PRODUCT TYPE: Ridge Vent

Introduction. Our Ref: Chilt/IF12041 AR1. 24 th June Astra Door Controls Ltd Unit 10 Astra Business Centre Roman Way Preston PR2 5AP

Technical Services Report

THE UNITED KINGDOM VEHICLE APPROVAL AUTHORITY EU TYPE-APPROVAL CERTIFICATE

Automatic Entrance Systems

Visions 3000 Series 924 Parts Catalog

Volume Control Dampers. Series LF upvc-vcd High performance plastic volume control dampers. Incorporating

PETROLEUM MEASUREMENT MANUAL THE PERFORMANCE OF TURBINE METERS IN LOADING GANTRIES - A REVIEW OF PROVING AND TEST DATA

Certification Scheme

Sound-absorbing spacer Sorp10

SPECTRUM PRESTIGE 86MM PROFILE SYSTEM

EU Mutual Recognition Technical Requirements

Unwin T-Bolts. Unwin TN, TN1, TN2, TN3, TNL, TNL1, TNL2, TNL3, TNS. Instructions for fitting and operating

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

CERTIFICATE OF APPROVAL No CF 5543 ASSA ABLOY SECURITY SOLUTIONS

Craigieburn Employment Precinct North and English Street

ISO :2015/DAM 1

INSTITUTE OF PETROLEUM TESTING OF VAPOUR CONTAINMENT ON PETROLEUM ROAD TANKERS

Product Datasheet. Cable TV Junction Box (Page 4)

ANSI/BIFMA X Desk/Table Products - Tests. American National Standard for Office and Institutional Furnishings

TEST REPORT FOR: Product Design Group Fuze T50 Manual Wheelchair (204 kg / 450 lb)

Combinations. Monolithic Glass: Standard thickness: 4mm and 6mm Substrate: SGG PLANILUX clear float. Toughened Glass:

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

Louvre systems. Series WL Standard weather louvres. Incorporating. Standard range of single bank louvres as used in countless installations worldwide

4. If applicable, name and address of manufacturer's representative: Not applicable

Report Number BTC 12261F

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES CLP S-D-A FTSH S-DV-A SAMTEC, INC.

AUGUST 28, 2008 TEST REPORT # REV.1.1 MIXED FLOWING GAS TESTING CONNECTOR SERIES SEM H-D-WT TEM H-D-WT SAMTEC, INC.

Title: The fire resistance performance of a specimen of single-acting single-leaf doorset in accordance with BS EN : Report No: A

AS AS Australian Standard. Starter batteries Lead acid. This is a free 6 page sample. Access the full version online.

FUNCTIONAL SAFETY CERTIFICATE

ISO 3934 INTERNATIONAL STANDARD

SAMPLE RETENTION POLICY

Rototherm Certificates of Calibration Traceability and Quality System

Transcription:

Exova (UK) Ltd Key Industrial Park Fernside Road Willenhall West Midlands WV13 3YA T : +44 (0) 1902 722 122 F : +44 (0) 1902 727 242 E : willenhall@exova.com W: www.exova.com BS EN ISO 10077-1:2006 Calculation of: Door U Value Thermal Performance of Windows, Doors & Shutters Calculation of Thermal Transmittance A Report To: Debar Ltd Whitehall Properties, Towngate, Wyke, Bradford, BD12 9JQ Date: 29/11/2016 Copy: 1 Issue No.: 1 Page 1 Document Reference: WIL 376371 Registered Office: Exova (UK) Ltd, Lochend Industrial Estate, Newbridge, Midlothian EH28 8PL United Kingdom. Reg No.SC 70429 This report in issued in accordance with our terms and conditions, a copy of which is available on request.

CONCLUSIONS Drawings of: Manufacturer Product Model Debar Ltd DeWall A1 3 Panel Slide Fold Door Set, Aluminium Have been submitted for thermal performance calculation in accordance with BS EN ISO 10077-1:2006. By Christian Adams, a BFRC certified simulator (No. 125) of Exova (UK) Ltd, a UKAS accredited Testing Laboratory (No. 0621) and EC Notified Body number (No. 1104) At Key Industrial Park, Fernside Rd, Willenhall, West Midlands, WV13 3YA. Results and comments as detailed below: Description Doorset 1 36mm 4-12-4-12-4 e=0.05 pos 1,3 Doorset 2 44mm 4-16-4-16-4 e=0.05 pos 1,3 U D value W/(m 2.K) 1.5 1.4 No inferences can be made regarding performance against other requirements of this standard Document No.: WIL 376371 Page No.: 2 of 22

AUTHORISATION Calculations performed by: Christian Adams, Thermal Test Engineer Report issued by: Christian Adams, Thermal Test Engineer Signed Date 29 th November 2016 For and on behalf of Exova (UK) Ltd Report authorised by: Mark West, Door & Window Laboratory Manager Signed Date 29 th November 2016 For and on behalf of Exova (UK) Ltd Report issued: 29 November 2016 NOTE. Tests marked Not UKAS Accredited are not covered by the Laboratory UKAS accreditation schedule. Tests marked NT were not tested Tests marked NA are not applicable to the product on test. Exova (UK) Ltd is an EC Notified Body Number 1104 This report shall not be reproduced except in full, (and then only as permitted by copyright laws), without written approval from Exova (UK) Ltd. Document No.: WIL 376371 Page No.: 3 of 22

CONTENTS PAGE NO. CONCLUSIONS... 2 AUTHORISATION... 3 CALCULATION DETAILS... 5 PROCEDURE... 6 CONCLUSIONS... 7 LIMITATIONS... 7 ANNEX A: SIMULATION RESULTS & CALCULATIONS... 8 ANNEX B: DOORSET DRAWINGS... 11 ANNEX C: SOURCE DATA... 15 ANNEX D: THERM MODELS... 16 REVISION HISTORY... 22 Document No.: WIL 376371 Page No.: 4 of 22

CALCULATION DETAILS CLIENT DETAILS Company name Address Debar Ltd Whitehall Properties Towngate Wyke Bradford BD12 9JQ Contact Marjanas Petraitis ORDER DETAILS Order number 2713 Dated 16/11/2016 PRODUCT DETAILS Product Model Manufacturer Material DeWall A1 3 Panel Slide Fold Door Set, Aluminium Debar Ltd Aluminium CALCULATION DETAILS Specification BS EN ISO 10077-1:2006 Clauses N/a Calculation methods BS EN ISO 10077-1:2006 Thermal performance of windows, doors & shutters Calculation of thermal transmittance Part 1: General BS EN ISO 10077-2:2012 Thermal performance of windows, doors & shutters Calculation of thermal transmittance Part 2: Numerical method for frames BS EN 673:2011 Glass in building Determination of thermal transmittance (Uvalue) Calculation method Simulation software & spreadsheet versions used Thermal transmittance models obtained by computer simulation using Therm Finite Element Simulator V5.2.14 provided by LBNL. Software validated in accordance with Annex D of BS EN ISO 10077-2. Exova BS EN 673 Ug spreadsheet TR099 version 2 issue 7 Exova BS EN ISO 10077 doorset U-value spreadsheet Document No.: WIL 376371 Page No.: 5 of 22

PROCEDURE Introduction This report should be read in conjunction with the Standard BS EN ISO 10077-1:2006 Thermal performance of windows, doors and shutters Calculation of thermal transmittance Part 1: General, BS EN ISO 10077-2:2012 performance of windows, doors and shutters Calculation of thermal resistance Part 2: Numerical method for frames & BS EN 673:2011 Glass in building Determination of thermal transmittance (U value) Calculation method Drawings in DXF format were submitted for calculation of thermal transmittance in accordance with BS EN ISO 10077-1. Instruction Calculation method The calculations were conducted on the 18 th 21 st November 2016 on behalf of Debar Ltd. Calculation was carried out in accordance with Clause 5.4 of BS EN ISO 10077-1 using an area weighted average of U f and U g shown in equation 8, plus the edge effect of the glazing perimeter Ψ g. As per Clause 6 of BS EN ISO 10077-1 Input Data the thermal transmittance of the frame U f and the linear thermal transmittance of the glazing junction were carried out by simulation in accordance with Annex C of BS EN ISO 10077-2 using THERM finite element analysis software version 5.2.14 provided by LBNL. Simulations were produced both with the glazing in place, and the glazing replaced with an insulation panel of thermal conductivity 0.035. Values used for the design thermal conductivity of materials in this calculation were taken from Annex A of BS EN ISO 10077-2:2012 unless specified otherwise, and are listed in Annex C of this report. As such the result contained in this report is partly derived from tabulated values and should be considered indicative and not definitive. Document No.: WIL 376371 Page No.: 6 of 22

CONCLUSIONS Evaluation against objective The sectional drawings of the doorsets as provided by the client were subjected to thermal performance calculations in accordance with BS EN ISO 10077-1 Observations & comments LIMITATIONS Limitations Range of assemblies covered by this report The results relate only to the behaviour of the specimens of the element of construction under the particular conditions of the calculation. They are not intended to be the sole criteria for assessing the potential performance of the element in use, nor do they reflect the actual behaviour in use. Table E.2 of BS EN 14351-1:2006 +A1:2010 states that the range of direct application (providing similar design) of doorset assemblies covered by this report is limited to the following: Doorsets with overall area 3.6m 2 for doorsets simulated at 1.23m x 2.18m. Doorsets with overall area >3.6m 2 for doorsets simulated at 2.0m x 2.18m Height and width of simulated assemblies subject to a tolerance of ±25%. Uncertainty of Measurement The uncertainties of measurements calculated for a confidence level of 95% throughout these tests are within the limits of these tolerances. The user and the simulation software have been validated in accordance with Annex D of BS EN ISO 10077-2:2012, giving the following accuracies: Thermal transmittance ± 5% Linear thermal transmittance ± 5% Document No.: WIL 376371 Page No.: 7 of 22

ANNEX A: SIMULATION RESULTS & CALCULATIONS Doorset 1 - BS EN 673:2011 calculation for 4-12-4-12-4 Argon filled unit 4mm toughened / 12mm Argon fill / 4mm toughened / 12mm Argon fill / 4mm toughened (ε=0.05 coating position 1 & 3) Doorset 2 - BS EN 673:2011 calculation for 4-16-4-16-4 Argon filled unit 4mm toughened / 16mm Argon fill / 4mm toughened / 16mm Argon fill / 4mm toughened (ε=0.05 coating position 1 & 3) Document No.: WIL 376371 Page No.: 8 of 22

Doorset 1 - ISO 10077-2:2012 calculation Document No.: WIL 376371 Page No.: 9 of 22

Doorset 2 - ISO 10077-2:2012 calculation Document No.: WIL 376371 Page No.: 10 of 22

ANNEX B: DOORSET DRAWINGS Doorset internal elevation Frame area A f = 1.44 m 2 Document No.: WIL 376371 Page No.: 11 of 22

Doorset 1 - head & sill section Doorset 1 - hinge & lock jamb section Document No.: WIL 376371 Page No.: 12 of 22

Doorset 1 meeting stile section Doorset 2 - head & sill section Document No.: WIL 376371 Page No.: 13 of 22

Doorset 2 - hinge & lock jamb section Doorset 2 meeting stile section Document No.: WIL 376371 Page No.: 14 of 22

ANNEX C: SOURCE DATA Materials used Design thermal conductivity of materials used in the simulation Material Conductivity (W/ m.k) Emissivity Source Aluminium (painted) Frame Stainless Steel (painted) Cill running track Glass Infill panel Polysulphide Spacer bar secondary sealant Polyamide 6.6 25% glass fibre Frame thermal break EPDM Weatherseal and glazing gaskets Thermobar Spacer bar Elastomeric foam Glazing packer 160 0.9 17 0.9 1.0 0.9 0.40 0.9 0.30 0.9 0.25 0.9 0.14 0.9 0.05 0.9 ISO 10077-2:2012 Table A.1 & A.4 ISO 10077-2:2012 Table A.1 & A.4 ISO 10077-2:2012 Table A.1 ISO 10077-2:2012 Table A.1 ISO 10077-2:2012 Table A.1 ISO 10077-2:2012 Table A.1 BF Datasheet 27 Rev Index 0 ISO 10077-2:2012 Table A.1 Cavities Conductivity (W/ m.k) Emissivity Source Unventilated cavity Unventilated Cavity Slightly ventilated cavity Various Various ISO 10077-2:2012 Clause 6 λeff for 12mm cavity 4-12-4-12-4 air filled unit, pos 1 & 3 0.05 low-ε coating λeff for 16mm cavity 4-16-4-16-4 air filled unit, pos 1 & 3 0.05 low-ε coating 0.0213 0.90 0.0225 0.90 By calculation according to BS EN 673:2011 By calculation according to BS EN 673:2011 Document No.: WIL 376371 Page No.: 15 of 22

ANNEX D: THERM MODELS Doorset 1 - head models (for L f 2d and L ψ 2d respectively) Doorset 1 hinge jamb models (for L f 2d and L ψ 2d respectively) Document No.: WIL 376371 Page No.: 16 of 22

Doorset 1 locking jamb models (for L f 2d and L ψ 2d respectively) Doorset 1 meeting stile models (for L f 2d and L ψ 2d respectively) Document No.: WIL 376371 Page No.: 17 of 22

Doorset 1 cill models (for L f 2d and L ψ 2d respectively) Document No.: WIL 376371 Page No.: 18 of 22

Doorset 2 - head models (for L f 2d and L ψ 2d respectively) Doorset 2 hinge jamb models (for L f 2d and L ψ 2d respectively) Document No.: WIL 376371 Page No.: 19 of 22

Doorset 2 locking jamb models (for L f 2d and L ψ 2d respectively) Doorset 2 meeting stile models (for L f 2d and L ψ 2d respectively) Document No.: WIL 376371 Page No.: 20 of 22

Doorset 2 cill models (for L f 2d and L ψ 2d respectively) Document No.: WIL 376371 Page No.: 21 of 22

REVISION HISTORY Issue No : Re - Issue Date : Revised By: Approved By: Reason for Revision: Issue No : Re - Issue Date : Revised By: Approved By: Reason for Revision: END OF REPORT Document No.: WIL 376371 Page No.: 22 of 22