Regenerative DC Common Bus Supply

Similar documents
Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

BR Second Position Voltages. AA Fourth Position

Data Bulletin. ALTIVAR FLEX58 Chassis Drive Controllers Class 8806 INTRODUCTION DESIGN CONCEPT. Bulletin No. 8806DB0102 August 2001 Raleigh, NC, USA

RVS-AX Instruction Manual

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

AC Drives Regenerative Energy Solutions. Product Summary

J1000 D E F I 1000 J1000 J1000 J1000 J1000

MX1S Matrix Converter

RVS-DX Digital Reduced Voltage Motor Starter

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

RVS-DN Digital Reduced Voltage Motor Starter

Description 1/8-7.5HP

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Hitachi America, Ltd.

Fincor Series 2230 MKII/2240

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

MaxPak Plus Analog DC V S Drive

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

J1000. Compact Inverter Series.

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

Power Supplies PSS Series

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

ALTIVAR FLEX58 Chassis Drive Controller Product Selection

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Delta Products VFD CP2000 Bypass Control Packages.

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Chapter 1: Getting Started User Manual Overview...1 2

PowerOhm Installation Manual for BM R Series Braking Modules

Unidrive M700 Class leading performance with onboard real-time Ethernet

SECTION VARIABLE FREQUENCY DRIVE UNITS

High performance Vector Control. Ratings. System configuration

GS2 Series - Introduction

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

This manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.

TDBU Series Dynamic brake unit user manual

ROBICON W120 enclosed drive

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

Reduced Voltage Motor Starters

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Applications: General purpose industrial use with permanent magnet or shunt wound DC motors. Description

SOLSTART Instruction Manual

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

SDC,Inc. SCR-Regenerative Ac Drive

EATON 9315 UPS 200 TO 300 KVA Specifications

SINUS K 13. ACCESSORIES Braking resistors APPLICATION TABLES 78/160 INSTALLATION INSTRUCTIONS

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Industrial Variable Speed A-C Motors B-4511

PowerOhm Installation Manual for BM R Series Braking Modules

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Three Phase UPS Systems Range: 10 to 500kVA

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

Powerdrive FX Ultra compact regenerative drive solution

A flexible, reliable and affordable drive for 1/4 through 2 HP DC applications

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

Low voltage AC drives

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

1 Phase electronic contactor (SC 1)

Softstarters Type PSS. Softstarters. General information

Design Guide. VLT Soft Start Controller MCD 100

Application Note. Common Bussing AC Drives. For 650 and 690+ series drives APP-AC-03

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

EFFEKTA Power Supplies

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

ABB Component Drives ACS150, 0.5 to 5 Hp

Operating Instructions. VLT Soft Starter - MCD 500. Phone: Fax: Web: -

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Datasheet. Pitch Motor PMSM SP260B8

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Datasheet. Pitch Motor PMSM SP190C8

USERS MANUAL MCD REMOTE OPERATOR

Applications: Conveyors, machine tools and other applications requiring adjustable speed. Mult. Sym.

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

vacon nx ac drives brake resistors user manual

Datasheet. Pitch Motor PMSM SP190F8

DYNAMIC BRAKING (DB) OPTION

DIGITAX ST UNIMOTOR 2000RPM COMBINATIONS

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Transcription:

Regenerative DC Common Bus Supply The Regenerative DC Common Bus Supply supplies both motoring and regenerative current to the DC bus of one or more AC drives without the need of rectifier front end in each AC drive. When the overall power requirements of the attached common DC bus drives require motoring power, energy flows from the utility to the common DC bus. When the overall power requirements of the attached common DC bus drives require regenerative power, energy flows from the common DC bus to the utility. Typical Applications that require regeneration are: High Inertia Loads that must be stopped or slowed down quickly - Saws, Fans, Flywheels and Centrifuges. Unwind Stands of all types - Uncoilers, Payoffs Overhauling Loads - Hoists, Cranes, Downhill Conveyors and Holdback Rolls in Process Line Applications. Machine applications with fast cycle times that require rapid deceleration. Our Regenerative DC Common DC Bus Supply Module is easy to use. There are only five wires to connect: 3 - AC Power and 2 - DC Bus. Our Regenerative DC Common Supply Modules are 99% efficient and operate at near unity power factor. Modules are easily paralleled for higher power applications. ELIMINATES THE NEED FOR ENERGY WASTING BRAKING RESISTORS PROVIDES CONTINUOUS REGENERATION ON OVERHAULING LOADS INSTANTANEOUS ENERGY FLOW BETWEEN LOAD & UTILITY PREVENTS AC DRIVES FROM OVERVOLTAGE TRIPPING ALLOWS RAPID STOPPING OF HIGH INERTIA LOADS USES THE LATEST GENERATION OF IGBT POWER DEVICES DELIVERS SUBSTANTIAL ENERGY SAVINGS PHASE INSENSITIVE TO THE AC POWER LINE RDCCB1

SPECIFICATIONS AND FEATURES Electrical Specifications: Rated Input Voltage: 200-250Vac, 380-500Vac, 500-600Vac -10% of minimum, +10% of maximum. Frequency Tolerance: 47-63 Hz Number of Phases: 3 Efficiency: 99% or greater Max. Short Circuit Current Rating: 200,000A rms symmetrical, 600 volts (when used with AC input line fuses specified in tables 1 to 3). Noise Immunity: IEEE C62.41-1991 Category B (Formerly known as IEEE 587) - 6000V tests EN50082-1, 2 Generic Immunity Standards IEC 1000-4-2 ( IEC 801-2 ) IEC 1000-4-3 ( IEC 801-3 ) IEC 1000-4-4 ( IEC 801-4 ) IEC 1000-4-5 ( IEC 801-5 ) IEC 1000-4-6 ( IEC 801-6 ) IEC 1000-4-8 ( IEC 801-8 ) Environmental Specifications: Ambient Temperature: Storage Temperature: Altitude: Humidity: Vibration: -10C to 55C (14F to 131F) Nema type 1 enclosed. -40C to 70C (-40F to 158F) Nema type 1 enclosed. Sea level to 3000 Feet [1000m] without derating. 95% relative humidity non-condensing. 9.8m/sec 2 (1.0G) peak. Physical attributes: Mounting: Nema Rating: Construction: Though hole or panel mount. Type 1 (IP20) as standard, Type 12 (IP54) optional. Steel construction (reduces E.M.I.) Control I/O: 2 Digital Inputs: Regen Enable & Regen Reset 2 Digital Outputs: Form C dry contacts rated 115Vac @ 5A; 30Vdc @ 3.5A. 1 meter output: Use with 100A movement analog meter. 24Vdc source: Use to power operator pushbuttons and US Drives option boards: 24Vdc @ 100 ma max. Protective Features: Peak output current monitoring to protect against line-to-line shorts and line-to-ground shorts. Ground fault monitoring. Heatsink over-temperature monitoring. AC line & DC bus over-voltage protection. AC line & DC bus under-voltage protection. Control power supply power ride-thru. Internal power supply monitoring. AC phase loss detection. Standard Regen Features Latest generation IBGT. Nema type 1 (IP20) as standard for all models. 55C ambient with standard Nema type 1 (IP20) enclosure. High voltage ratings: 250Vac+10%, 500Vac+10% models, and 600Vac+10% models Input line suppression: Metal oxide varistors for line-to-line and line-to-ground voltage surge protection. No programming or hardware jumper for all voltages. RDCCB2

Frame Designation Table 1 Class 200 Regenerative DC Common Bus Supply Models (Typical Voltage 208/230/240 VAC) NEMA 1 (IP20) Catalog Number Drive HP 2 200-250VAC (-10% to +10%) Continuous Continuous Regen Motoring DC Bus DC Bus Current Current AC Current Maximum Recommended AC Line Fuses 3 Total Power Losses 4 (W) SIZE 1 RGB-0200-0030-N1 15 30 37 39 60 176 RGB-0200-0045-N1 20 45 49 50 70 239 RGB-0200-0060-N1 30 60 73 63 90 302 RGB-0200-0090-N1 40 90 98 97 125 428 RGB-0200-0120-N1 60 120 146 143 200 554 SIZE 2 RGB-0200-0180-N1 75 180 183 179 250 806 RGB-0200-0240-N1 100 240 244 231 350 1058 RGB-0200-0300-N1 125 300 305 290 400 1300 RGB-0200-0360-N1 150 360 366 335 500 1562 SIZE 3 RGB-0200-0480-N1 200 480 488 446 600 2066 RGB-0200-0540-N1 250 540 610 560 800 2318 RGB-0200-0600-N1 300 600 732 670 900 2570 RGB-0200-0720-N1 350 720 854 781 1000 3074 RGB-0200-0840-N1 400 840 976 893 1200 3578 RGB-0200-0960-N1 450 960 1098 1004 1500 4082 RGB-0200-1080-N1 500 1080 1220 1116 1500 4586 1 KW based on 240Vac AC Power line. 2 Drive HP ratings are calculated for 230 VAC Motors based on 100% Continuous Regeneration and 150% Regeneration for 1 Minute or Less. Consult Factory for Module sizing when Regeneration requirements are less than or greater than these values. 3 Semiconductor Fuses: Ferraz Shawmut A50P, A60X, Bussmann FWH. 4 Total Power Loss shown is for continuous operation at full regeneration. Frame Designation Table 2 Class 400 Regenerative DC Common Bus Supply Models (Typical Voltage 380/415/480 VAC) NEMA 1 (IP20) Catalog Number 380-500VAC (-10% to +10%) Continuous Continuous Regen Motoring Drive HP 2 DC Bus DC Bus Current Current AC Current Maximum Recommended AC Line Fuses 3 Total Power Losses 4 (W) SIZE 1 RGB-0400-0030-N1 30 30 37 37 50 200 RGB-0400-0045-N1 40 45 49 48 70 275 RGB-0400-0060-N1 60 60 73 72 100 350 RGB-0400-0090-N1 75 90 91 89 125 500 RGB-0400-0120-N1 100 120 122 115 175 650 SIZE 2 RGB-0400-0180-N1 150 180 183 167 250 950 RGB-0400-0240-N1 200 240 244 223 350 1250 RGB-0400-0300-N1 300 300 366 336 450 1525 RGB-0400-0360-N1 350 360 427 385 600 1850 SIZE 3 RGB-0400-0480-N1 450 480 549 502 800 2450 RGB-0400-0540-N1 500 540 610 558 800 2750 RGB-0400-0600-N1 600 600 732 670 900 3050 RGB-0400-0720-N1 700 720 854 781 1000 3650 RGB-0400-0840-N1 800 840 976 893 1200 4250 RGB-0400-0960-N1 900 960 1098 1004 1500 4850 RGB-0400-1080-N1 1000 1080 1220 1116 1500 5450 1 KW based on 480Vac AC Power line. 2 Drive HP ratings are calculated for 460 VAC Motors based on 100% Continuous Regeneration and 150% Regeneration for 1 Minute or Less. Consult Factory for Module sizing when Regeneration requirements are less than or greater than these values. 3 Semiconductor Fuses: Ferraz Shawmut A50P, A60X, Bussmann FWH.. 4 Total Power Loss shown is for continuous operation at full regeneration. RDCCB3

Frame Designation Table 3 Class 500 Regenerative DC Common Bus Supply Models (Typical Voltage 525/575/600 VAC) NEMA 1 (IP20) Catalog Number Drive HP 2 525-600VAC (-10% to +10%) Continuous Continuous Regen Motoring DC Bus DC Bus Current Current AC Current Maximum Recommended AC Line Fuses 3 Total Power Losses 4 (W) SIZE 1 RGB-0500-0030-N1 30 30 32 35 40 236 RGB-0500-0045-N1 50 45 49 48 70 329 RGB-0500-0060-N1 75 60 73 72 100 422 RGB-0500-0090-N1 100 90 98 92 125 608 RGB-0500-0120-N1 125 120 122 116 175 794 SIZE 2 RGB-0500-0180-N1 200 180 195 179 250 1166 RGB-0500-0240-N1 250 240 244 225 350 1538 RGB-0500-0300-N1 350 300 342 312 450 1900 RGB-0500-0360-N1 400 360 390 355 600 2282 SIZE 3 RGB-0500-0480-N1 500 480 488 439 700 3026 RGB-0500-0540-N1 600 540 586 536 800 3390 RGB-0500-0600-N1 700 600 683 625 900 3770 RGB-0500-0720-N1 800 720 781 714 1000 4514 RGB-0500-0840-N1 900 840 878 804 1200 5250 RGB-0500-0960-N1 1000 960 976 893 1200 6002 RGB-0500-1080-N1 1300 1080 1269 1161 1500 6746 1 KW based on 600Vac AC Power line. 2 Drive HP ratings are calculated for 575 VAC Motors based on 100% Continuous Regeneration and 150% Regeneration for 1 Minute or Less. Consult Factory for Module sizing when Regeneration requirements are less than or greater than these values. 3 UL Class T, High Speed/Class J, and Semiconductor Fuses (preferred): Ferraz Shawmut A60X, A70P, Bussmann FWP. 4 Total Power Loss shown is for continuous operation at full regeneration. RDCCB4

Approximate Weight: 35 Lbs. [16 Kgs] Notes: - Top and bottom endplates are removable to gain access inside the drive and to punch holes for conduits. - Endplates must be removed from the drive before drilling and punching holes to avoid metal dust inside the drive enclosure. Failure to do so will cause damage to the drive. - For through-panel mounting, customer is to seal for gap on all side of cutout. Provided by customer, aluminum angle 1 x 1 x 0.050 can be used to attach to all sides of drive to help seal and secure the drive. Figure 2 AC Regen Mounting Information: Size 1 (Nema Type 1) RDCCB5

Approximate Weight: 150 Lbs. [68 Kgs] Notes: - Top and bottom endplates are removable to gain access inside the drive and to punch holes for conduits. - Endplates must be removed from the drive before drilling and punching holes to avoid metal dust inside the drive enclosure. Failure to do so will cause damage to the drive. - For through-panel mounting, customer is to seal for gap on all side of cutout. Provided by customer, aluminum angle 1 x 1 x 0.050 can be used to attach to all sides of drive to help seal and secure the drive. Figure 2-2a AC Regen Mounting Information: Size 2 (Nema Type 1) RDCCB6

Approximate Weight: 450 Lbs. [204 Kgs] Notes: - Top and bottom endplates are removable to gain access inside the drive and to punch holes for conduits. - Endplates must be removed from the drive before drilling and punching holes to avoid metal dust inside the drive enclosure. Failure to do so will cause damage to the drive. - For through-panel mounting, customer is to seal for gap on all side of cutout. Provided by customer, aluminum angle 1 x 1 x 0.050 can be used to attach to all sides of drive to help seal and secure the drive. - Size 3 enclosure can also be free-standing with optional floor stand kit from US Drives, Inc. Figure 2-2b AC Regen Mounting Information: Size 3 (Nema Type 1) RDCCB7