Innovative Power Supply System for Regenerative Trains

Similar documents
Energy Management for Regenerative Brakes on a DC Feeding System

Power management control in DC-electrified railways for the regenerative braking systems of electric trains

Train Group Control for Energy-Saving DC-Electric Railway Operation

Application of energy storage systems for DC electric railways

- friction and heat free braking of moderately

K. Shiokawa & R. Takagi Department of Electrical Engineering, Kogakuin University, Japan. Abstract

Development of the Regenerative Power Compensation Device SANUPS K23A (R Type)

A study of the power capacity of regenerative inverters in a DC electric railway system

Common Bus and Line Regeneration

Energy Storage for Traction Power Supply Systems

Development of Motor-Assisted Hybrid Traction System

Technical Explanation for Inverters

APPLICATION NOTE QuickStick 100 Power Cable Sizing and Selection

SDC,Inc. SCR-Regenerative Ac Drive

REAL TIME TRACTION POWER SYSTEM SIMULATOR

Development of a High Efficiency Induction Motor and the Estimation of Energy Conservation Effect

A Bidirectional Universal Dc/Dc Converter Topology for Electric Vehicle Applicationsand Photovoltaic Applications

Examples of Electric Drive Solutions and Applied Technologies

The evaluation of endurance running tests of the fuel cells and battery hybrid test railway train

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

Technical Guide No. 7. Dimensioning of a Drive system

Development of Emergency Train Travel Function Provided by Stationary Energy Storage System

Method to tie feeding cables for energy conservation

Applications for energy storage flywheels in vehicles of Deutsche Bahn AG

Energy Saving Technologies for Elevators

Regenerative Braking System for Series Hybrid Electric City Bus

Targeted Application of STATCOM Technology in the Distribution Zone

Specifications and schedule of a fuel cell test railway vehicle. T. Yoneyama, K. Ogawa, T. Furuya, K. Kondo, T. Yamamoto

Special edition paper

Application Case. Issued by Solution Center Date May, 2013 Pages 5

Special edition paper

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

Soft Start for 3-Phase-Induction Motor

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

MIKLOS Cristina Carmen, MIKLOS Imre Zsolt UNIVERSITY POLITEHNICA TIMISOARA FACULTY OF ENGINEERING HUNEDOARA ABSTRACT:

Development of ESS for Regenerative Energy of Electric Vehicle

The Modeling and Simulation of DC Traction Power Supply Network for Urban Rail Transit Based on Simulink

Supercapacitor Based Power Conditioning System for Power Quality Improvement in Industries

Fully Regenerative braking and Improved Acceleration for Electrical Vehicles

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Technology Development of Dual Power Supply System for Mild Hybrid System and Micro Hybrid System

Power Supply, Energy Management and Catenary Problems. Editor: Eduardo Pilo Universidad Pontificia Comillas de Madrid, Spain

Field Tests of DC 1500 V Stationary Energy Storage System

INVENTION DISCLOSURE MECHANICAL SUBJECT MATTER EFFICIENCY ENHANCEMENT OF A NEW TWO-MOTOR HYBRID SYSTEM

Abstract In this paper, we developed a lateral damper to improve the running safety of railway vehicles

V1000, A1000, E7, F7, G7,

Improvements to the Hybrid2 Battery Model

American Traction Systems

Current collecting characteristics of catenary with non-tension contact wires

INNOVATIVE SOLUTION: HESOP. Mr. Swarup Chakraborty

Components of Hydronic Systems

EXTENDING PRT CAPABILITIES

Electrification and Power Supply. Andrea Nardinocchi Technological Design Department Italferr S.p.A., Rome, Italy

Adaptive Power Flow Method for Distribution Systems With Dispersed Generation

Advanced Railway System Development Center, Research & Development Center of the JR East Group Hiroshi Nomoto

Fundamentals and Classification of Hybrid Electric Vehicles Ojas M. Govardhan (Department of mechanical engineering, MIT College of Engineering, Pune)

ABB POWER SYSTEMS CONSULTING

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

STEADY STATE ELECTRICAL DESIGN, POWER PERFORMANCE AND ECONOMIC MODELING OF OFFSHORE WIND FARMS

Optimizing Drive Systems for Energy Savings

Central Japan Railway Company, Komaki, Japan 1 ; Central Japan Railway Company, Tokyo Japan 2

INTRODUCTION. I.1 - Historical review.

Reducing Train Weight and Simplifying Train Design by Using Active Redundancy of Static Inverters for the Onboard Supply of Rolling Stock

Chapter 4. Design and Analysis of Feeder-Line Bus. October 2016

A COMPARISON OF THE PERFORMANCE OF LINEAR ACTUATOR VERSUS WALKING BEAM PUMPING SYSTEMS Thomas Beck Ronald Peterson Unico, Inc.

Special edition paper Development of an NE train

Power Flow Simulation of Flywheel Energy Storage Systems for Tramways

POWER DISTRIBUTION SYSTEM ANALYSIS OF URBAN ELECTRIFIED RAILWAYS

Development of Variable Geometry Turbocharger Contributes to Improvement of Gasoline Engine Fuel Economy

Review paper on Fault analysis and its Limiting Techniques.

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Dual power flow Interface for EV, HEV, and PHEV Applications

Regenerative Braking System Using Ultracapacitor For Electric Vehicles

Simulation research on rail transit traction grid voltage stabilization and its energy saving effects based on BESS

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Power Quality Improvement Using Statcom in Ieee 30 Bus System

Technology from the New Product SANUPS K for a Smart Grid Society

Steering Actuator for Autonomous Driving and Platooning *1

Rescue operations on dedicated high speed railway lines

Hybrid Wheel Loaders Incorporating Power Electronics

A Study on Energy Usage Efficiency Improvement Scheme in 48V Multi-axis Robot System

Protective firing in LCC HVDC: Purposes and present principles. Settings and behaviour. V. F. LESCALE* P. KARLSSON

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

A Measuring Method for the Level of Consciousness while Driving Vehicles

Torque Management Strategy of Pure Electric Vehicle Based On Fuzzy Control

Elevator Drives Energy Consumption & Savings

Maximum Superelevation: Desirable, Allowable, and Absolute

ESS SIZING CONSIDERATIONS ACCORDING TO CONTROL STARTEGY

i-eloop Regenerative Braking System

HIGH VOLTAGE vs. LOW VOLTAGE: POTENTIAL IN MILITARY SYSTEMS

Offshore Application of the Flywheel Energy Storage. Final report

1) The locomotives are distributed, but the power is not distributed independently.

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

Present Status and Prospects of High-Power Conversion Systems

One-Cycle Average Torque Control of Brushless DC Machine Drive Systems

C&D VRLA Batteries Extended Run Time for Small UPS Machines

CLOSED CIRCUIT HYDROSTATIC TRANSMISSION

INTRODUCTION. In today s highly complex and interconnected power systems, mostly made up of thousands of buses and hundreds of generators,

Transcription:

Innovative Power Supply System for Regenerative Trains Takafumi KOSEKI 1, Yuruki OKADA 2, Yuzuru YONEHATA 3, SatoruSONE 4 12 The University of Tokyo, Japan 3 Mitsubishi Electric Corp., Japan 4 Kogakuin University, Japan Abstract The authors are proposing pure electric brake which supplies service brake in normal operation solely in electrical mode down to complete stop. This reduces mechanical wear of brake linings and realises much better riding comfort with easier and exacter braking manoeuvre. This full usage of the regenerative braking mode is getting popular in Japan. However, there are still problems to be solved before all related parties can enjoy advantages of this technique; insufficient braking force at high speed due to the power limitation, squeezing of braking force at excessive line voltage at the pantograph of the braking train, and giving up the regeneration when no other trains simultaneously absorb the regenerated power. Combination of regenerative and rheostatic brakes has, therefore, been introduced to some lines, which have long and steep slopes. This paper deals with countermeasures in power feeding system by introducing equipment for absorbing regenerated power effectively. Several case studies show the effectiveness of the wayside power-absorbing components for the full usage of the regenerative electric brakes. 1 Introduction DC-electrification is often used for urban public transport. Although many trains have power electronic components for regenerative braking as well as powering motors for acceleration recently, it is often difficult to fully use the

regenerative electric brake, since the regenerative action requires simultaneous electric loads, which may be mainly other powering trains, in the same electrified line. If there is no considerable electric load in the system, the pantograph voltage immediately increases up to the maximal limitation during its electric braking action, which results in failure of electric motion and supplemental compensation or the braking action by its mechanical braking system. This tendency is being more obvious since the number of train sets, which have regenerative braking function, has been increased. The full usage of the regenerative electric brake for ordinary braking action has the following inherent advantages: (1) saving energy, (2) saving maintenance works on account of the reduction of the chance of mechanical braking action, and (3) better passenger comfort due to good and stable transient response of the braking force. The main purpose of this paper is to investigate how to reduce the probability of the failure of regenerative braking actions for energy-saving and maintenancesaving railway operation. Several strategies for the full usage of the regenerative brake have been discussed, e.g., : (1) constant power electric braking pattern, with which the peak regenerative power at high speed drive is suppressed, by giving weak braking command when the train runs fast, (2) intentional activation of onboard auxiliary equipment, e.g., air- conditioner and compressor when the electric loads are insufficient, and (3) comprehensive power management controls [1]. The methods listed above have been investigated [1][2] in detail and the validity of the strategies have been proven through numerical simulations. However, such strategies cannot guarantees the regenerative action completely. A substantial solution may be to equip the components which absorb excessive power. Fig.1 shows a possible type of DC-electrification. Powering train 2MW Actually calculated components Regenerating train 4MW Figure 1: Typical power flow on braking.

2 Substations with Inverter Function and the Definition of Case Studies Fig. 1 also shows the scenario of numerical studies in this paper. On braking, The decelerating train at the section between substations 2 and 3 converts kinetic energy to electrical one. The location of the regenerating train is assumed just the centre of the two substations for a simple calculation using symmetric assumption without losing generality of the analysis. Thanks to this symmetric assumption, one can manage the simulation in a half size. Fig. 2 shows the current-voltage characteristics of different types of convertors assumed in this study. The thyristor convertor/inverter can control itself and keep the voltage constant up to its nominal load current, whereas the conventional diode rectifier has voltage drop proportional to its load current. The PWM convertor/inverter can control its voltage constant for all the amount of its load current. The PWM-convertor voltage is set to 1600V, which is of 100V higher than the system nominal voltage, so that one can use out the advantage of constant voltage operation. Inverter voltages for regenerative action is set to 1620V, which is slightly higher than convertors' no load voltage, for avoiding unfavourable direct power flow from converting to inverting substations. For the case of the PWM convertor/inverter configuration, one can, of course, set the substation voltages to 1500V, which is just identical to their nominal system voltages. A regenerating train could send its generated power from further location to another powering train in this case compared to the case of the 1600V-setting, but one must accept inherently more stationary loss in general, since one needs more current to send the identical power with lower voltage. Therefore, the case of 1600V will be studied in detail here, for energy-saving operation is one of the significant purposes of introducing new regenerative components into the substations. V N =1500V PWM inverter Thyristor inverter 1600V 1590V 1320V V PWM rectifier 1620V Thyristor rectifier Diode rectifier 3 I N 3 I N I Figure 2:Typical characteristics of different substation convertors. I N

3 Preconditions for the Calculations of the Case Studies The distance of two substations is assumed to 4.5km constant as shown in Fig, 2, and the train at the centre between the substations 2 and 3 intends to regenerate and send back the power of 4.0MW to the electric system. The powering train locating at 0.75km-point from the substation 1 is taking power of 2.0MW from the electric line. Hence, the distance between the powering and the braking trains is 6.0km. The trains are modelled as DC-power source in the simulation. The upper power limitation of regenerating components have not been assumed in this study, whereas the real thyristor inverter may keep the inverter voltage of 1620V constant only up to the five times of its nominal regenerative current. The upper limitation of PWM converters may be approximately 300% of its nominal regenerative current. The line resistance is assumed to 0.03 /km. The voltages of the resistor chopper in case II and the chopper for the energy storage in case V are also set to 1620V constant. The difference between these two cases is only the count of regenerated and lost powers after the substantial circuit calculations. The upper limitation of the regenerated current of the train is 2kA constant up to the pantograph voltage of 1700V and the limit value is linearly reduced to 0A between the pantograph voltages of 1700V and 1800V. The inner loss of the trains contains the joule loss in filter reactors of the onboard inverter. The power has been doubled and the line resistance has been divided by two, for calculating the power flow of double tracks in a simplified calculation with a single track modelling. 4 Calculated Results and Comparisons The power flows, current and voltage distributions dependent on different substation equipment, have been obtained from DC-circuit calculations and indicated in figures from 3 through 7. Fig. 3 represents the basic case of diode rectifiers, which have no regenerative functions. The substation 2 has nothing to do, since the resultant voltage at the entry point of the substation 2 is higher than the no-load voltage of 1590V of the diode rectifier. The pantograph voltage of the regenerating train has been too high, since there is nothing absorbing its excessive power, and the regeneration of the braking power has been partially given up. The chopper-controlled resistor absorbs the excessive power in Fig. 4. The voltage at the entry point of the substation 2 is suppressed to 1620V of the nominal DC-voltage of the resistor-chopper, which results in the lower pantograph voltage of the regenerating train, and full regenerative braking action has been guaranteed. But the absorbed power has been immediately converted to joule loss in the wayside resistor, and there is no contribution for energy saving in this configuration. The thyristor inverter in Fig. 5 is also controlling the entry voltage of the substation 2 to 1620V, which is identical to case II. Main difference from Fig. 4

Figure 3: The Case I: Conventional diode rectifiers at the substations 1 and 2. 1226 Rectifier loss: 14 1212 14 2026 Powering loss: 26 36 Resistor: 1005 loss: 10 1015 101 1980 Regenerating Current[A] 771 533 1160 0.75km 3.75km 2.25km SS1 Powering train SS2 Braking train Figure 4: Case II: Conventional diode rectifier with a wayside braking resistor controlled by a chopper.

1226 Rectifier loss: 14 995 Thy Inv 1212 14 2026 Powering loss: 26 36 1015 101 1980 Regenerating Current[A] 771 533 1160 0.75km 3.75km 2.25km SS1 Powering train SS2 Braking train Figure 5: Case III: Conventional diode rectifier and thrystor inverter. 1545 PWM Inv loss: 46 1277 PWM Inv loss: 39 1499 22 2025 Powering loss: 25 15 1316 101 1980 Regenerating Current[A] 937 348 1160 0.75km 3.75km 2.25km SS1 Powering train SS2 Braking train Figure 6: Case IV: PWM inverters in the substations1 and 2.

is that a part of the regenerated energy is sent back to the AC-power system. Since the voltage in the AC-side is high, which may result in the small current sent back into AC-side, the loss in the AC-side has not been considered in this calculation. The rated voltage of the thyristor inverter is designed slightly lower than the case of PWM inverter, since it has relatively large ripples in voltage as well as current waveforms. 12-bridge inverter configuration shall be applied in practice for reducing these ripples and harmful effects from switching harmonics. Both substations 1 and 2 have PWM-inverters in Fig. 6. This case seems to have slightly worse efficiency than the case in Fig. 5, but this comparison may not be so simple, since the thyristor inverters will need supplemental filter circuits, whose loss is not negligible, for suppressing the effects of the switching harmonics in practice. Fig. 7 shows a case of the usage of generic energy storage device whose total efficiency of charging/discharging actions is assumed 75% in the substation 2. It can be super-capacitors, fly-wheels, battery systems or these combinations. Only the charging efficiency of 0.75 has been considered in this calculation. One must pay attention to the fact that the finally reusable energy will be the amount of the stored energy furthermore multiplied by factor 0.75. The circuit behaviour has been identical to the case of Fig. 4, but this system has a substantial advantage that you can reuse the stored energy, and the total energy efficiency will be inherently better than Fig. 4. From these calculations, the criteria values have been summarised in table 1 for comparing the goodness of the possible DC-substation configurations in the 1226 Rectifier loss: 14 Storage: 879 loss: 136 1212 14 2026 Powering loss: 26 36 1015 101 1980 Regenerating Current[A] 771 533 1160 0.75km 3.75km 2.25km SS1 Powering train SS2 Braking train Figure 7: Conventional rectifier with a way-side energy storage.

era of regenerative trains. The restriction for the regenerative action for the braking train has occurred only in the case I. This shows that energy absorbing equipment is inherently effective and useful in order to guarantee the regenerating braking action. Table 1: Summary of the calculated power flow. Electric braking ratio in % (Reusable power)/ (Regenerated power) in % Total system energy efficiency in % Total goodness Case I 76 89* 68 Not preferable Case II 100 41 41 Not preferable Case III 100 91 91 Preferable Case IV 100 91 91 Preferable Case V 100 85** 85** Preferable *seems good, but it is not true, since the regenerated power in the denominator of the definition of this criteria is small, because of the squeezing control of its electric brake. ** this figure does not include the efficiency of recharging process. The really usable energy will be smaller, i.e., to be multiplied by 0.75. 5 Conclusions The authors have calculated and compared power flows in several power regenerating equipment in DC-electrified railway system to make full use of the regenerative braking action of modern trains. It is beneficial for the effective usage of regenerative brakes to send back the power to AC-commercial electrical network through inverters at substations, or to implement energy storage devices at substations. When one partially introduces inverters to substations, the rated voltage of the inverters should be set slightly higher than rectifiers, otherwise unfavourable

power flows would occur from powering to inverter substations. The simultaneous implementation of the inverters to each substation is preferable. Power storage system is often discussed for balancing power demand between daytime and night. The balancing function for the peaky power deviation in very short time scale like this example of railway traction power balance, the charging and discharging energy efficiency may tend to be worse. Therefore, the relatively conservative total efficiency of 75% has been assumed in this conceptual investigation. From these fundamental calculations, it has been obviously shown that the cases from III to V are preferable for the DC-electrifying equipment for the generation of power electronic traction system with regenerative braking. This study has, however, included neither economical assessment, in which the balance between initial and running costs as well as the life cycle of the total system, nor environmental impacts. Such a comprehensive viewpoint shall be taken into account for a realistic system design in near future. Especially, the power storage device may be implemented concentrated to specific substations from the economical and maintenance reasons, although this aspect has not been quantitatively discussed either in this paper. References [1] Y. OKADA, T. KOSEKI, S. SONE, Energy Management for Regenerative Brakes on a DC Feeding System, STECH 03, pp 376-380, 2003 [2] S. SONE, Re-examination of Feeding Characteristics and Squeezing Control of Regenerative Trains, Joint Technical Meeting Transportation and Electric Railway and Linear drives, TER-02-49/LD-02-64, 2002