Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

Similar documents
Flow Control Valve IOM 770-U

IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

IOM IR-110-X. Solenoid Control Valve

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

PRESSURE RELIEF VALVE CONTROL VALVE

INSTRUCTION MANUAL INSTALLATION OPERATION TROUBLESHOOTING MAINTENANCE PRESSURE RELIEF VALVE WITH SURGE ANTICIPATION (HYDRAULIC) FEATURE MODEL 50RWR-A

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

PRESSURE RELIEF VALVE

SINGLE ACTING ALTITUDE VALVE

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

INSTALLATION & MAINTENANCE MODEL mm

1451 Control Valve. General Instructions. Table of Contents

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM)

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

INSTRUCTIONS Installation - Operation - Inspection - Maintenance 4" - 16" ROSS MODEL - 30AWR FIGURE 29 SINGLE ACTING ALTITUDE VALVE

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Pressure Reducing Valve Type 2114/2415

INSTALLATION, OPERATION AND MAINTENANCE Threaded and Wafer Style Flowmeters

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

CUSTOM COMBINATION AIR VALVE

4 - Way Control 4 - Way Control 4 - Way Control with lock

ROOTS Meters Series B3 Meter Models 8C175-56M175

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

Operation and Maintenance Manual

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

AUTOMATIC FLOW CONTROL VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

METERING VALVE 2" STEM GUIDED

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

GP-2000 : Trouble Shooting. Cause of problems

Industrial Turbo Meters, Sizes 2" through 6"

INSTRUCTIONS FOR INSTALLATION, START-UP, AND OPERATION

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Fisher 2052 Diaphragm Rotary Actuator

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

BERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

Automatic (Air Release) Air Valve

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

6 8 Magnum 40(x) Maintenance Instructions

DC-501 Double Check Backflow Preventer OPERATIONS, MAINTENANCE AND TROUBLESHOOTING GUIDE

PRESSURE REDUCING CONTROL VALVE

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Type EZR Relief Valve or Backpressure Regulator

BERMAD Irrigation. High Performance Plastic Valves. 100 Series - Water Control Solutions

Deep Well Pump Control Valve

WARNING Carefully Read These Instructions Before Use

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

Ordering Guide. Ordering Guide. May Water Control Solutions

Series 820 AWWA Butterfly Valves

Manually Operated Diaphragm Valves

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

PRESSURE REDUCING VALVE

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

Butterfly valves Figure 56 Installation & Maintenance Instructions

HTX-HTH SEPARATORS I&O MANUAL

Pilot-Operated Regulators

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

2001 SERIES CRYOGENIC BAR STOCK BODY VALVES

Three Way Pilot Control

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

Series 995/995RPDA. Sizes: 3" - 6" Reduced Pressure Zone Backflow Preventer/ Reduced Pressure Detector Assemblies RP/IS-995/995RPDA

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Crispin Valves Operating Guide. Crispin

Instructions for Installing and Operating Clark Reliance EA100 Series Levalarm

TECHNICAL DATA CAUTION

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

TECHNICAL CHARACTERISTICS

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

V-SEGMENT SERIES V-Port Segment Control Valves (VS/VV/VM) Installation & Maintenance Manual

200 Series - Plastic Hydraulic/Electric Control Valves. Water Control Solutions

Type EZR Relief Valve or Backpressure Regulator

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

Model 116 DPI Switch Installation and Operating Instructions

THIS WARRANTY IS IN LIEU

BERMAD Waterworks. Electronic Control Valve. 700 Series. Model Features and Benefits. Major Additional Features

Series 20 Installation Instructions

Transcription:

IOM IR-472-50-bRU Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300) Description: The BERMAD Flow Control and Pressure Reducing Valve with Hydraulic Control is a hydraulically operated, diaphragm actuated control valve that performs three independent functions. It controls system demand to a preset maximum flow rate; it reduces downstream pressure to a constant preset maximum, and it either opens or shuts in response to a remote pressure command. Installation: 1. Ensure enough space around the valve assembly for future maintenance and adjustments. 2. Prior to valve installation, flush the pipeline to insure flow of clean fluid through the valve. 3. For future maintenance, install Isolation gate valves upstream and downstream from Bermad control valve. 4. Install the valve in the pipeline with the valve flow direction arrow in the actual flow direction. 5. The orifice assembly should be attached to the valve inlet flange, with a resilient gasket between them. Determine tightening bolts length according to flanges, gaskets and orifice assembly thickness. Note: if the valve end connections are Thread, then the orifice assembly is already connected to the valve. 6. Install the orifice assembly in the flow direction and confirm connection of the sensing ports, marked [+] and [-], according to the attached drawing. 7. For best performance, it is recommended to install the valve horizontally and upright. 8. After installation carefully inspect/correct any damaged accessories, piping, tubing, or fittings. Commissioning & Calibration: 1. Confirm that the In-line filter (4A) arrow direction is in the valve flow direction. 2. Allow the valve to start regulation by opening the cock valve [2]. (Handle is parallel to cock valve body). 3. Open fully the upstream isolating valve and slowly open the downstream isolating valve, to fill-up, carefully, the consumers' line downstream from the Valve. 4. Vent air from the valve's control loop by loosening cover tube fitting at the highest point, allowing all air to bleed. Then Retighten the tube fitting. 5. The IR-472-50-RUb is factory set according to the design. The set pressure is marked on each of the pilot's label. 5.1. The set flow on the Flow Control Pilot [FCP] (PC-SD) label. 5.2. The set downstream pressure on the Pressure Reducing Pilot [PRP] (PC-20) label. 6. If the set flow and/or pressure reduce are either different from the design or the requirements have been changed, change settings according to the following: 6.1. Unlock the PRP locking nut and slowly turn the pilot adjusting screw Clock-Wise [CW] to increase set pressure and Counter -Clock-Wise [CCW] to decrease it. Allow the 472-50-RUb to react and the downstream pressure to stabilize, lock the PRP locking nut and open fully the downstream isolating valve. 6.2. Confirm/create demand higher than the required new set point 6.3. Unlock the FCP locking nut and slowly turn the pilot adjusting screw CW to increase set flow and CCW to decrease it. Allow the 472-50-RUb to react and the flow to stabilize, lock the FCP locking nut. 7. Connect the remote control to the opening port in the hydraulic relay valve (50 M).

IOM IR-472-50-bRU Trouble-Shooting: Symptoms Cause Remedy Valve fails to open 1. Cock valve [2] is closed. 2. Hydraulic control command. 3. Not sufficient inlet pressure. 4. Not sufficient flow. 5. Adjusting screws. 1. Check Cock valve status. 2. Check no existence hydraulic command in the relay. 3. Check for sufficient inlet pressure. 4. Create demand/flow, confirm pilot setting. 5. Check that the Pilot adjusting screw is not loose. Valve fails to close 1. Hydraulic control command. 2. Control circuit is clogged. 3. Debris. 4. Diaphragm. 1. Check existence of hydraulic command in the relay (50 -M). 2. Check for any debris trapped in the valve control circuit. 3. Check for any debris trapped in the valve body. 4. Check diaphragm is not leaking. Valve fails to regulate 1. Not sufficient inlet pressure. 2. Not sufficient flow. 3. Pilots setting. 4. Air trapped in the control chamber. 1. Check for sufficient inlet pressure. 2. Create demand/flow, confirm pilot setting. 3. Check Pilot setting. 4. Release air trapped in the control chamber. Preventive maintenance: 1. System operating conditions that effect on the valve should be checked periodically to determent the required preventative maintenance schedule. 2. Maintenance instructions: 2.1. Tools required: 2.1.1. Metric and imperial wrenches 2.1.2. Anti-seize grease 2.1.3. Visual inspection to locate leaks and external damages 2.2. Functional inspection including: closing, opening and regulation. 2.3. Close upstream and downstream isolating valves (and external operating pressure when used) 2.4. Once the valve is fully isolated vent pressure by loosening a plug or a fitting. 2.5. Open the screw nuts and remove the cover unit from the valve body. Disassemble necessary control tubs. 2.6. It is highly recommended to stock a reserve parts assembly for each size. This allows minimum system field work. And system down time. 2.7. Disassemble the cover and examine the inside parts carefully for signs of wear, corrosion, or any other abnormal conditions. 2.8. Replace worn parts and all the Elastomers. Lubricate the bolts and screws threads with Anti seize grease. 2.9. Winterizing /freezing prevention: drain the valve & the valve accessories (pilot, solenoid) on time. Spare Parts Bermad has a convenient and easy to use ordering guide for valve spare-parts and control system components. For solenoid valves refer to model and S/N on solenoid tags. Pub # : IOM-IR-472-50-RUb-3'' 12''' By : YG 4/13 Rev: YG 4/13 File name : IOM-IR-472-50-Rub-3"-12''- 4/13 PT1AE08-01

BERMAD IR Spare Parts 400 Series Basic Control Valves For Irrigation (IR) Sizes: ; 10 -¾ DN20-250 12 Effective 10/2014

BERMAD IR Spare Parts 400 Series Basic Control Valves For Gardening (LS) Sizes: ; 2 -¾ DN20-50 12a Effective 10/2014

BERMAD IR Spare Parts 400 Series Basic Control Valves (IR & WW) Sizes: ; 12-14 DN300-350 13b Effective 10/2014

BERMAD IR Spare Parts 400 Series Accessories 13c Effective 10/2014

BERMAD Spare Parts PC Series PC-20-AM Metal 2-way Pressure Reducing Mini Pilot Valve 32 2/05

BERMAD Spare Parts PB Pilots #2PB 2-way Pressure Reducing Pilot Valve 50d 2/05