TTF/BGTS Series. Return In-Tank Filters. Global Filtration Technology

Similar documents
Oil Solutions. TTF/BGTS Series Return In-Tank Filters. Global Filtration Technology. Filtration.

BGT Series. Low Pressure Filters

Oil Solutions. GA/BGAH Series Medium Pressure Filters. Global Filtration Technology. Filtration.

AGS/MPN Series. Medium Pressure Filters. Global Filtration Technology

KLT and KLS Series Tank Top Return Line Filters

AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF. Product Features:

AN INNOVATIVE GREEN FILTER FEATURING LEIF LEIF. Product Features:

PT Series Tank Top Filters

TTF Series MAX 500 I/min - 10 bar

RF4 Series. Return Line Filters

PT Series. Tank Top Filters

Moduflow Series IL2/RF2/CF2 Low Pressure Filters

HIGH PRESSURE FILTERS

Moduflow. ILP and RFP Low Pressure Filters. Series

Tank Top Mounted Suction & Return Line Filters Types SR1 & SR2. Max 250 l/min - 10 bar. Brochure HYD001GB3

Tanktop Mounted Return Line Filters. ETF Series. MAX 140 I/min - 6 bar. Low pressure filters

12AT/50AT Series Spin-On Filters

Hydraulic Filtration & Contamination Control Products. Brochure: FDHB200UK (Low Pressure Section)

15/40/80CN Series Coreless Medium Pressure Filters

15/40/80CN Series. Medium Pressure Filters

Portable Filter Carts Models 5MF and 10MF

MEDIUM PRESSURE FILTERS

12AT/50AT Series. Spin-On Filters. Global Filtration Technology

Duplex Pressure Filters

HIGH PRESSURE FILTERS

Series RFL In-Line Filter

12CS/50CS Series Coreless Medium Pressure Filters

12AT/50AT Series Spin-On Filters

HIGH PRESSURE FILTERS

12CS/50CS Series. Coreless Spin-on Filters

10 Hydraulic Filters

Series RFLD Duplex In-Line Filter

LF(M) High Viscosity Filter Assemblies. hyprofiltration.com/lf

PT Series. Tank Top Filters

Low Pressure Filters. Low Pressure Filters LOW PRESSURE FILTERS

IL8 Series. Medium Pressure Filters

10 Hydraulic Filters

SPIN-ON FILTERS & ELEMENTS

HIGH PRESSURE FILTERS Series HF2P

15P/30P Series High Pressure Filters

HIGH PRESSURE FILTERS

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

IL8 Series. Medium Pressure Filters

12CS Series. Coreless Spin-on Filter Max. 75 l/min - 35 bar. Environmentally friendly alternative for spin-in filtration.

LOW PRESSURE FILTERS RF Series In-tank / Inline Filters 360 psi up to 400 gpm

HIGH PRESSURE FILTERS HF4P Series Inline Filters 5000 psi up to 120 gpm

LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

Filter elements for installation in Pall filter housings. Type 16. filter elements. Contents. Features. RE Edition:

MPD Series. Medium Pressure Duplex

Pressure: Max working 8 bar (116 psi) (acc. to NFPA T ) Burst 16 bar (232 psi) (acc. to NFPA T ) Buna-N (FKM on request)

Medium Pressure Filters

World Pressure Filters A new standard in 7,000 psi pressure filters

MPD Series. Medium Pressure Duplex

HIGH PERFORMANCE FILTERS INDUSTRIAL HYDRAULIC AND LUBRICATION APPLICATIONS

12CS Series Coreless Spin-on Filter Max. 75 l/min - 35 bar

Portable Hydraulic Filtration Systems. Guardian. MAX 15 I/min - 2 bar. Portable filtration systems

World Pressure Filters. A New Standard in 7,000 psi Pressure Filters

Custom & Standard Filter Elements ISO 9001:2008 CERTIFIED

Hydraulic & Lubrication Filters

[You may download this article at: ]

LOW PRESSURE FILTERS RFM Series In-Tank Return Line Filters 145 psi up to 224 gpm

Guardian Portable Filtration System

HIGH PRESSURE FILTERS DFFX Series Reverse Flow Differential Pressure Optimized Filters 6090 psi up to 160 gpm

World Pressure Filters A New Standard in 7,000 psi Pressure Filters

Low Pressure Filters

FCL Filter Cart Flow rate up to 22 gpm (82 lpm)

MPD Series Medium Pressure Filters

12S Series High Pressure Filters

Process & Chemical Fluid Filtration Liquid filtration systems for beverage, chemical and food processing; cosmetic, paint, fabrication.

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

High Pressure Filters. 15P/30P Series. MAX 200 I/min bar. High pressure filters

Oil Conditioning Unit

COMPANY. Liquid Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:FLOWLIQUIDMETERMAN082516

PFH. High Pressure In-line Filter Assemblies. hyprofiltration.com/pfh

PRESSURE FILTERS FOR MODULAR STACKING. Series DF-Z Pressures to 4500 psi Flows to 10 gpm APPLICATION PRODUCT FEATURES FILTER ELEMENTS

50P Series High Pressure Filters

D e s c r i p t i o n

NFH Low Pressure Filters

HD 790 HD 990 In-line mounting Operating pressure up to 630 bar / 9137 psi Nominal flow rate up to l/min / gpm

Connection Ports: 3/4 1 1/4 BSP (other thread options on request)

Fabricated Tee Strainers Style T & TQ; 150#, 300# and 600# Flanged or Butt Weld Connections...6 Technical Data...7

Rosedale Model HSS300 and HSS750 Single Cartridge Housings for Liquids

Distributed By: M&M Control Service, Inc

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

High Pressure Filters Worldline 400 HD 790 HD 990. In-line mounting Operating pressure up to 9137 psi Nominal flow rate up to gpm. 40.

MATERIALS CARTRIDGES PRESSURES VALUES TESTS CARRIED OUT ON FILTER ELEMENTS

HMK05/25 DURAMAX Spin-Ons

A Filtration Primer. Filter Elements. High Pressure Filters. Tank-Mounted, Return Line and Medium Pressure Filters. Water Service Filters

LS 025 LS 035 In-line mounting Connection up to G¾ / -12 SAE Nominal flow rate up to 33 l/min / 8.7 gpm

22PD/32PD Series High Pressure Duplex Filters Max 260 l/min bar

Portable Filter Carts 10MFP with Moduflow

Pressure: Max working 280 bar (4000 psi) (acc. to NFPA T ) Burst 840 bar (12200 psi) (acc. to NFPA T )

Filter solutions for Danfoss PAH, APP and CLP pumps

ES 134 ES 144 Tank top mounting Connection up to SAE 1½ Nominal flow rate up to 130 l/min

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

Hydraulic Filtration & Contamination Control Products. Brochure: FDHB200UK

Filtering elements differential collapsing pressure tested in compliance with ISO 2941:

HPK04 Max Flow: 120 gpm (454 lpm)

Transcription:

Return In-Tank Filters Global Filtration Technology 25

Features/Applications for Tank Top Return Flow Filters Flows to 640 GPM 3 Micron Absolute to 120 Micron Absolute Disposable or Recleanable Elements Visual and Electrical Indicators BetaMaze long life elements Full flow bypass valve No internal leakage paths Inside-to-out flow thru element Complete contaminant removal during element service Optional LEIF element Magnetic prefiltration Specifications Housing Data: Material: Head Aluminum Alloy Diffusor Steel Internals Carbon Steel and Aluminum Seals Nitrile (Standard), FKM Pressure Rating: Static 150 psi (10.3 bar) Temperature Range: Operating -40 F to +250 F (-40 C to +120 C) 26

Models TTF and BGTS Tank Mounted Return Flow Filters 1 TTF and BGTS Filters feature Arlon s exclusive Magnetic Prefiltration core which collects ferromagnetic particles from fluid upstream of the filter element. This feature alone could save hundreds of dollars a year by protecting costly equipment from increased wear and malfunction by assuring that the fluid is as pure as possible when it leaves the filter. Even during bypass due to cold start up, contaminant is collected by the magnetic core, a feature of importance on any fluid power system. Take a close look and compare Arlon features with any other filter. 2 1. Fluid flows through the inlet port into an enlarged area which reduces fluid velocity. Inlet flow does not impinge on the element. 4 3 2. Filtration begins with magnetic prefiltration of ferromagnetic particles in the full fluid flow upstream of the element, not downstream or in the reservoir. Built-in or system generated ferromagnetic wear debris (even particles smaller than the element rating) are collected by the high strength (3.0K Gauss) magnetic column. This results in extended element and oil life and reduced maintenance and downtime, which reduces overall operating cost. 3. Fluid passes through the element in an inside-to-outside direction, collecting particles inside the filter cartridge. This eliminates reinjection of contaminant during element change. Clean fluid then returns to the reservoir through the diffusor which prevents fluid aerations. Normal return line filters, that flow outside-to-inside, allow contaminated fluid to drain back into the reservoir when the element is serviced. 4. Simplified bypass design and location prevents flushing previously collected contaminant back into the system. Since the element serves as the valve there is no troublesome separate valve to remove when changing elements. Magnetic filtration occurs even during bypass. All potential leakage paths are o-ring sealed to eliminate bypass leakage that occurs in loose fitting valve assemblies. TTF and BGTS Filters are available with disposable or cleanable elements of several contamination class levels for use in all common fluids. Optional accessories include weld plates, which simplify installation, and visual and electric warning indicators, that assure proper element service. B D F (A) TTF-230 (B) BGTS-390 with Gauge (C) TTF-60 (D) TTF-300 with Switch and Weld Plate (E) TTF-120 with Gauge and Weld Plate (F) BGTS-500 A C E 27

How To Size Tank Top Filters Element Pressure Drop Factor: Multiply the actual flow rate times the applicable P factor to determine the pressure drop with a fluid viscosity of 140 SSU. Correct for other viscosities by applying the following formula: Flow rate (GPM) x filter factor x (new viscosity in SSU/140 SSU). Flow/Pressure Drop Data Fluid Conditions: Viscosity-140 SSU Sp. Gr. - 0.88 Media Size Code Code 60 90 120 170 230 300 390 500 600 1000 2000 GDL3.905.603.452.286.205.157.122.097.082.0493.0246 GDL6.345.236.168.103.079.057.045.037.031.0187.0091 GDL10.280.187.127.074.052.044.032.024.022.0129.0066 MB/ST10.238.166.123.088.065.049.037.029.025.0152.0073 GDL20.214.137.107.049.038.031.022.017.014.0088.0044 ST25.079.055.041.030.021.016.012.010.008.0050.0025 TXX.040.029.021.018.013.010.007.006.005.0030.0015 ST40.036.025.018.014.010.007.006.0044.004.0023.0011 Example: Element Size Code = 230 Element Media Code = GDL10 Filter Factor =.052 (From chart) Flow = 60 GPM Viscosity = 160 SSU Formula: 60 GPM x.052 x (160 SSU/140 SSU) = 3.6 PSID Element Data Multipass Test Results To ISO 4572 Media Absolute (Time Weighted Averages) Type Rating B 3 B 6 B 10 B 12 B 20 B 25 B 36 GDL 3 100 800 2000 >5000 GDL 6 8 100 1000 2000 >5000 GDL 10 6 22 100 200 >5000 GDL 20 2 8 20 100 200 >5000 TXX 36 2 3.5 6 23 100 28

TTF-60, TTF-90, TTF-120 Return Line Filter Series 1 TTF Filter Model inches (mm) 60 90 120 C 6.25(159) 8.0 (203) 10.0 (254) L 9.25 (235) 11.0 (280) 13.0 (330) P 1" NPT or 16 SAE Straight Thread O-Ring D 3.66/3.56 (93/90) E* 4.50/3.75 (114/95) E* dimension using weld plate TTF-170, TTF-230, TTF-300 Return Line Filter Series 2 TTF Filter Model inches (mm) 170 230 300 C 11.0 (279) 13.5 (343) 21.5 (546) L 12.0 (305) 12.0 (305) 20.0 (508) P 1½ NPT or 24 SAE Straight Thread O-Ring D 5.36/5.26 (136/133) E* 6.25/5.50 (159/140) E* dimension using weld plate 29

BGTS-390, BGTS-500 RETURN LINE FILTER SERIES 3 BGTS Filter Model inches (mm) 390 500 C 15.75 (400) 23.25 (590) L 14.57 (370) 22.05 (560) P 2" SAE 3000lb. Flange D 6.54/6.52 (166/165.5) E* 7.25/6.75 (184/171) E* dimension using weld plate Accessories TANK TOP WELD PLATE Filter Series inches (mm) 1 2 3 A 5/16-18 UNC-2A 3/8-16 UNC-2A 3/8-16 UNC-2A B 5.33 (135) 7.15 (182) 7.67 (195) C 1.00 (25) 1.00 (25) 1.00 (25) D 3.59 (91) 5.29 (134) 6.58 (167) E 4.50/3.75 6.25/5.50 7.25/6.75 (114/95) (159/140) (184/171) 30

BGTS-600, BGTS-1000, BGTS-2000 Return Line Filter - Series 4 BGTS Filter Model inches (mm) 600 1000 2000 C 18.0 (457) 27.0 (686) 48.0 (1219) L 16.75 (425) 25.20 (640) 47.25 (1200) D 9.49/9.47 (241/240.5) E 10.25/9.70 (260/246) 31

Parts Breakdown TTF Series Cover 5842209 - TTF60/TTF120 5842210 TTF170/TTF300 Cover 0-Ring TTF60/TTF120 N72239, Nitrile V72239, FKM TTF170/TTF300 N72251, Nitrile V72251. FKM Top Spring 48371201 - TTF60/TTF120 48371205 TTF170/TTF300 Insert Consult Factory Insert O-Ring TTF60/TTF 120 SOR-64, Nitrile SOR-64-V, FKM TTF 170/TTF300 SOR-71, Nitrile SOR-71 -V, FKM Bypass Gasket TTF60/TTF 120 81.14.150.31. Nitrile 81.14.152.31, FKM TTF170/TTF300 81.14.150.32, Nitrile 81.14.152.32, FKM See Table Bypass Spring TTF60/TTF120 6903181 - Blocked 4903017-4.5 PSlD 4902001-12 PSlD 4903005-22 PSlD TTF 170/TTF300 6903182 - Blocked 4903018-4.5 PSlD 4903002-12 PSlD 4903006-22 PSlD Filter Head TTF60/TTF120 5841216 SAE16 5841248-1" NPT TTF170/TTF300 5841224 - SAE24 5841264-1 1/2" NPT Tank Gasket TTF60/TTF120 108x98x5.5B, Nitrile 108x98x5.5V, FKM TTF170/TTF300 152x1 36x68, Nitrile 152x1 36x6V, FKM Diffusor 2107002 - TTF60 2107003 - TTF90 Element Codes Disposable Recleanable MB Series TXX Series Betamaze Elements* ST Series High Effic. 10 Micron 3 Micron 6 Micron 10 Micron 20 Micron Recleanable 10 Micron 10µ Nom. 3µ Abs. 6µ Abs. 10µ Abs. 20µ Abs. St. Steel Model β10>2.5 β10>2 β3>100 β6>100 β10>100 β20>100 Mesh Elem. TTF-60 TXX2-10 TXW2-GDL3 TXW2-GDL6 TXW2-GDL10 TXW2-GDL20 ST2- TTF-90 TXX3-10 TXW3-GDL3 TXW3-GDL6 TXW3-GDL10 TXW3-GDL20 ST3-10 TTF-120 TXX3D-10 TXW3D-GDL3 TXW3D-GDL6 TXW3D-GDL10 TXW3D-GDL20 ST3D- 25 TTF-170 MB4 TXX4-10 TXW4-GDL3 TXW4-GDL6 TXW4-GDL10 TXW4-GDL20 ST4-40 TTF-230 MB5 TXX5-10 TXW5-GDL3 TXW5-GDL6 TXW5-GDL10 TXW5-GDL20 ST5- (Micron TTF-300 MB5A TXX5A-10 TXW5A-GDL3 TXW5A-GDL6 TXW5A-GDL10 TXW5A-GDL20 ST5A- Absolute) Material* Cellulose Cellulose Fiber, Fiber, Epoxy Glass Micro-fiber, Epoxy End Cap Adhesive Stainless Steel Plastisol End End Cap Mesh, Epoxy Cap Adhesive Adhesive End Cap Adhesive *All End Caps and Support Tubes are Plated Carbon Steel **For LEIF Elements, replace TXW with TXWL. Example: TXW4-GDL3 becomes TXWL4-GDL3 for LEIF style element. 32

Parts Breakdown BGTS Series Part Numbers Seals BGTS BGTS 390 or 500 600, 1000 or 2000 Description R-8575 R-8875 Cover O-Ring R-208 SOR-90 Insert O-Ring 81.14.150.33-Buna SOR-85 Bypass Seals 81.14.152.33-FKM 182 x 164 x 4 R8975 Tank Gasket SOR-113 SOR-115 Element O-Ring Nitrile or FKM Material* *Please specify seal material suffix when ordering Fluorocarbon seals: -V 2 1 3 4 5 See Table Bypass Assembly 390 Or 500 600, 1000 Or 2000 Pressure 6903183 6903184 Blocked 4903019 4903020 4.5 PSID 4903003 4903004 12 PSID 4903007 4903008 22 PSID Part Numbers Item Description Material BGTS-390 BGTS-500 BGTS-600 BGTS-1000 BGTS-2000 1 Top Spring Steel 83.07.012.03 48371205 2 Cover Die Cast 84.22.064.04 84.22.064.06 Aluminum (5842204) (5842206) 3 Head Die Cast 84.10.064.22 5841032 Aluminum (5841031) 4 Insert Assy. Bridge Aluminum Shaft- Steel, 13080000 13090000 14100000 14120000 14140000 Magnets Ceramic 5 Diffusor Steel 21100008 21100009 2110084 2110085 21100086 Element Codes Disposable Recleanable** MB Series TXX Series Betamaze Elements* ST Series High Effic. 10 Micron 3 Micron 6 Micron 10 Micron 20 Micron Recleanable 10 Micron Nominal Absolute Absolute Absolute Absolute St. Steel Model β 10 >2.5 β 10 >2 β 3 >100 β 6 >100 β 10 >100 β 25 >100 Mesh Elem. BGTS-390** MB8A TXX8A-10 TXW8A-GDL3 TXW8A-GDL6 TXW8A-GDL10 TXW2-GDL20 ST8A- BGTS-500** MB8C TXX8C-10 TXW8C-GDL3 TXW8C-GDL6 TXW8C-GDL10 TXW8C-GDL20 ST8C- 10 BGTS-600** TXX10-10 TXW10-GDL3 TXW10-GDL6 TXW10-GDL10 TXW10-GDL20 ST10-25 BGTS-1000** TXX12-10 TXW12-GDL3 TXW12-GDL6 TXW12-GDL10 TXW12-GDL20 ST12-40 BGTS-2000 TXX14-10 TXW14-GDL3 TXW14-GDL6 TXW14-GDL10 TXW14-GDL20 ST14- (Micron Absolute) Material* Cellulose Cellulose Fiber, Fiber, Epoxy Glass Micro-fiber, Epoxy End Cap Adhesive Stainless Steel Plastisol End End Cap Mesh, Epoxy Cap Adhesive Adhesive End Cap Adhesive *All End Caps and Support Tubes are Plated Carbon Steel **Coarser ratings available: Consult Factory **For LEIF Elements, replace TXW with TXWL. Example: TXW8C-GDL10 becomes TXWL8C-GDL10 for LEIF style element. 33

Operating And Maintenance Instructions Arlon Model TTF And BGTS Tank Top Filters A. Mounting 1. Standard mounting. a. Cut proper size hole in the top of the reservoir. b. Drill holes for studs within the proper bolt circle. c. Set the filter into the cutout hole and secure with proper size bolts, nuts and lock washers. 2. Mounting procedure using Arlon weld plate. a. Rough cut proper size hole in the top of reservoir. b. Weld the weld plate concentric to the rough cut hole. c. Mount the filter onto the studs and secure with nuts and lock washers. 3. Utilize proper fittings. B. Start-Up 1. Check for and eliminate leaks upon system start-up. 2. Check differential pressure indicator, if installed, to monitor element condition. C. Service 1. An element must be serviced when the differential pressure indicator indicates service is required. NOTE: If the filter is not equipped with a differential pressure indicator, the element should be serviced according to machine manufacturer s instructions. D. Servicing Dirty Elements 1. Shut system down to assure that there is NO PRESSURE OR FLOW into the filter housing. 2. Remove the filter cover. 3. Remove the filter insert (bridge which holds the element in place). 4. Remove the bypass spring assembly or non-bypass plate from the stud. 5. Remove the contaminated cartridge with a twisting motion. 6. a. Discard the disposable element cartridge. b. Wash cleanable or mesh elements in a non-caustic solvent. Compressed air can be used to facilitate cleaning. Use care to prevent damage to the element during cleaning. NOTE: Elements finer than 150 microns (100 mesh) may require special ultrasonic cleaning. Consult factory for recommendations. E. Before Installing A New Element Cartridge 1. Clean the magnetic core with a lint-free cloth. 2. Check all seals and replace if necessary. F. To Install A New Or Cleaned Element Cartridge 1. Lubricate all seals. 2. Mount new or cleaned Arlon filter cartridge. NOTE: For ease of mounting, hold the cartridge away from the magnetic core until the stud is through the hole in the bottom of the element. Then slide it up to securely seat it to the top of the bridge. 3. Install the bypass spring assembly or non-bypass plate, and tighten until snug. NOTE: Older versions may have a cotter pin/castellated nut retained bypass spring. In these cases, the nut should be turned down the shaft until the cross drilled hole is visible in the base of a castellation and the cotter pin inserted and ends flared to lock the bypass assembly in place. 4. Re-install the insert into the filter housing, making sure that the top-spring is secure. 5. Re-install the cover. Torque the cover nuts to 35 ft./lbs. Follow procedures B.1 and B.2. 34

HOW TO ORDER: Select the desired symbol (in the correct position) to construct a model code. Assembly Example: Return In-Tank Filters BOX 1 BOX 2 BOX 3 BOX 4 STD BOX 5 BOX 6 BOX 7 TTF-230 S24 TXW5-GDL10 B T 22 S TP Element Example: BOX 3 BOX 4 TXW5-GDL10 B BOX 1: MODEL Symbol Description FULL FLOW SURGE FLOW TTF-60 16 GPM (60 l/min) 30 GPM (110 l/min) TTF-90 24 GPM (90 l/min) 40 GPM (150 l/min) TTF-120 32 GPM (120 l/min) 50 GPM (190 l/min) TTF-170 50 GPM (190 l/min) 80 GPM (300 l/min) TTF-230 60 GPM (230 l/min) 100 GPM (375 l/min) TTF-300 80 GPM (300 l/min) 120 GPM (450 l/min) BGTS-390 105 GPM (400 l/min) 150 GPM (565 l/min) BGTS-500 135 GPM (510 l/min) 200 GPM (755 l/min) BGTS-600 160 GPM (600 l/min) 220 GPM (830 l/min) BGTS-1000 265 GPM (1000 l/min) 330 GPM (1250 l/min) BGTS-2000 530 GPM (2000 l/min) 640 GPM (2420 l/min) BOX 2 : PORTS Symbol Description TTF-60/90/120 S16 SAE-16 (1 1/16-12) N10 1 NPT TTF-170/230/300 S24 SAE-24 (1 5/16-12) N15 1 ½ NPT BGTS-390/500 F2 2 Code 61 SAE Flange BGTS-600/1000/2000 F3 3 Code 61 SAE Flange Please note the bolded options reflect standard options with a reduced lead- time. Consult factory on all other lead-time options. BOX 3 : ELEMENT Model Symbol 10µ Nom. 10µ Nom. 3µ Abs. 6µ Abs. 10µ Abs. 20µ Abs. St. Steel β 10 >2.5 β 10 >2 β 3 >100 β 6 >100 β 10 >100 β 20 >100 Cleanable TTF-60 TXX2-10 TXW2-GDL3 TXW2-GDL6 TXW2-GDL10 TXW2-GDL20 ST2- TTF-90 TXX3-10 TXW3-GDL3 TXW3-GDL6 TXW3-GDL10 TXW3-GDL20 ST3- TTF-120 TXX3D-10 TXW3D-GDL3 TXW3D-GDL6 TXW3D-GDL10 TXW3D-GDL20 ST3D- TTF-170 MB4 TXX4-10 TXW4-GDL3 TXW4-GDL6 TXW4-GDL10 TXW4-GDL20 ST4-10 TTF-230 MB5 TXX5-10 TXW5-GDL3 TXW5-GDL6 TXW5-GDL10 TXW5-GDL20 ST5-25 TTF-300 MB5A TXX5A-10 TXW5A-GDL3 TXW5A-GDL6 TXW5A-GDL10 TXW5A-GDL20 ST5A- 40 BGTS-390 MB8A TXX8A-10 TXW8A-GDL3 TXW8A-GDL6 TXW8A-GDL10 TXW8A-GDL20 ST8A- 60 BGTS-500 MB8C TXX8C-10 TXW8C-GDL3 TXW8C-GDL6 TXW8C-GDL10 TXW8C-GDL20 ST8C- 120 BGTS-600 TXX10-10 TXW10-GDL3 TXW10-GDL6 TXW210-GDL10 TXW10-GDL20 ST10- BGTS-1000 TXX12-10 TXW12-GDL3 TXW12-GDL6 TXW12-GDL10 TXW12-GDL20 ST12- BGTS-2000 TXX14-10 TXW14-GDL3 TXW14-GDL6 TXW14-GDL10 TXW14-GDL20 ST14- BOX 4 : SEALS Symbol Description B V TP OMIT Nitrile (Buna) Fluorocarbon (FKM) BOX 7 : OPTIONS Symbol Description Weld Plate If not required BOX 5 : BYPASS Symbol Description B Blocked 12 12 PSID (0.8 Bar) 22 22 PSID (1.2 Bar) BOX 6 : INDICATOR Symbol Description G S W V E OMIT 0-30 PSIG Gauge Pressure Switch w/½ Conduit Pressure Switch w/3 Wire Leads Visual Indicator (BGTS-600/2000 only) Electrical Indicator w/hirschmann (BGTS-600/2000 only) No Indicator 35

TTF/BGTS Notes Series 36