The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Similar documents
Unobox units with backward curved centrifugal impellers

AXIAL FANS Catalogue CN0050C01 May 2008

BDB DIDW CENTRIFUGAL FAN with Backward Wheel TYPE X TYPE T

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

KAT. DOUBLE INLET CENTRIFUGAL FAN with Forward Wheels

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

BOX BLB Centrifugal Box Fan

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Square Mixed Flow Fans (MFQ)

BSB. SINGLE INLET CENTRIFUGAL FAN with Backward Wheels

ATZAF DOUBLE INLET CENTRIFUGAL FANS WITH AIRFOIL BACKWARD CURVED BLADES

Centrifugal Fans belt driven. TD_CFB-RDY_EN Issue 1.1 EN July 2013

NEW Acoustic In-Line Fans (ACQ)

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

NEW WINDER. Impellers with higher efficiency and less sound level

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

Mixed Flow Roof Fans (RMH)

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

ACOUSTIC CABINET FANS CVB / CVT Series

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Sabre Plate Mounted Sickle Fans (VSP)

Plate mounted axial flow fans HXBR / HXTR Series

ACOUSTIC CABINET FANS CVAB / CVAT Series

Inside Front cover White

WINDER. Impellers with higher efficiency and less sound level

NEW Slimpak EC Box Fan (SLPT EC)

Mixed Flow Roof Fans (RMH)

Centrifugal Fans RZR belt driven. Issue 2.5 EN August 2013

FADE SERIES. Typical Specifications for Model FADE Sidewall Propeller Fans Sidewall propeller fans shall be of the direct driven type.

Parts and characteristics

Uniclass L7534. Manufacture controlled to ISO9001

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

Centrifugal Fans ADH belt driven. Issue 2.5 EN August 2013

Product Data Sheet ACi 4420 HHR

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

BPF. Centrifugal Plug Fans

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

Specifications. Applications Ventilation of safety cabinets (STORM 10), scrubbers, fume capture arms, filter housing, etc. (STORM 12, 14, 16).

to obtain the specified voids due

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

AND AXIAL FLOW FANS ECOFIT

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Sentinel D-Box Single Fan

CK, LPK, LPKB. Duct fans with circular connection.

ASA. SINGLE INLET CENTRIFUGAL FAN with Airfoil Wheels

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

ROOFMASTER STEF-HT ROOF FAN

ROOFMASTER STEF-HT ROOF FAN

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

Product Data Sheet ACi 4420 MLR

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

Sentinel D-Box Twin Fan

AC Commercial Fans Edition. ErP ready

CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

CENTRIFUGAL FANS. Single Width, Single Inlet WFS & WBS Series WTC TECH CO., LTD. CENTRIFUGAL FANS Single Width, Single Inlet WFS & WBS Series

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

VARYCONTROL VAV Dual Duct Terminal Boxes

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

ROOFMASTER STEF ROOF FAN

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

HIGH TEMPERATURE TWIN SQUIF FANS

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CHVB / CHVT Series. Cabinet fans designed for smoke extraction in fire condition F BACKWARD CURVED CENTRIFUGAL FANS CHVB / CHVT

CENTRIFUGAL IN-LINE FANS VENT Series

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

Vent-Axia Sabre Sickle Roof Fans (VSR)

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

MAJAX-2 GENERAL SPECIFICATION

ROOFMASTER STEF-ATEX ROOF FAN

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Acoustic Twin Fans (ATQ)

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

DIRECT-AIR ILB / ILT Series Rectangular duct fans

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Axial Fans

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

GigaBox centrifugal fans Product specific information

Transcription:

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans The Straight Way Rectangular Cabinet Fan Systemair India Pvt. Ltd. certifies that the Rectangular Cabinet Fan shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

2 Rectangular Cabinet Fan Rectangular Cabinet Fan CDRE The Systemair Rectangular Cabinet Fan units are the results of long experience in the development and manufacturing of ventilation systems. The partnership between highly motivated Systemair employees and world know component suppliers guarantees quality products on the highest technical level and precise reliability. The Systemair advantages: Modular system : Casings can be disassembled, if required. Easy installation. Min. 25mm perforated panels manufactured from pregalvanised mild steel with non-flammable mineral wool infill for thermal and acoustic insulation. All units are fitted with fans from the Systemair range, with external rotor motors for the direct driven units. Compact design Low-level noise The Systemair quality: Plug fans are installed in the Rectangular Cabinet Fans. The impeller with backward curved blades are external rotor motor and standard foot mounted motor (P44, 54 & 55) steel & aluminium impeller for all sizes. These plug fans are mounted on a motor supporting frame; the motor and impeller assembly is balanced dynamically in two levels according to VDI 2060. quality 0 2, 5. Tolerance in accordance with technical conditions of supply of fans DIN 24166, class 3. Panel insulation is provided by non flammable (AI) mineral fibre slab in accordance with DIN 4102. Thermal insulation K = 0.89 W/m²k in acc. With DIN 52210 Sound insulation R w = appr. 25dB in acc. With DIN 52210. The Systemair accessories: Flexible connections Shutters Counter Flanges The Systemair performance curves: Have been tested using a test chamber in accordance with with AMCA 210. The values refer to an air density of 1.2 kg/m³ at 20 C. Noise levels: The technical data show the A-weighted sound pressure levels LPA. Tolerance in accordance with technical conditions of supply of fans DIN 24166, class 3, noise level ca. 0.5 x \pfa max. The Systemair selection criteria: Size Air volume Static Pressure Sound requirements

Rectangular Cabinet Fan 3 Reference Code CDR CDR Model ( Rectangular Cabinet Fan ) E /D 315 E = Single phase AC Impeller diameter D = Three phase AC Safety Rules : PLEASE NOTE THE FOLLOWING ADVISE FOR INSTALLATION AND OPERATION OF SYSTEMAIR FANS Before you do any work on the fan you must disconnect the electrical supply first. The buyer is responsible that the local codes are being followed. During all maintenance works, the electrical connections must be checked. Warranty rules : The buyer is responsible for the selection and operations of the fan. The warranty is only for fans which are operating under normal conditions. Warranty is only valid when thermal protections (TK) are used. If the delivered goods shows failures, the customer can claim the exchange of the product or parts of it up to the amount of the buying price. Claims for secondary damages are not accepted. We reserve the rights to change the construction and design without notice, for the purpose of technical progress. Rectangular Cabinet Fans CDRE 315

4 Rectangular Cabinet Fan Rectangular Cabinet Fan CDRE 600 500 4 AMCA 210, ISO 5801:2007 p = 1.2kg/m³, 20 C, 1013 hpa 1 CDRE 315 1370rpm 2 CDRE 355 1383rpm 3 CDRE 400 1385rpm 4 CDRE 450 1340rpm 3 81 Static Pressure Ps [Pa] 400 300 2 1 73 76 74 82 200 73 71 72 77 82 100 70 74 0 0 71 75 78 84 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 Air Volume Q [m3/h] CDRE 315 CDRE 355 CDRE 400 CDRE 450 Voltage V 220 230 230 230 Frequency Hz 50 50 50 50 Phase - 1 1 1 1 Max. Motor Input Watts W 140 225 480 750 Max. Current A 0.68 0.94 2.1 3.2 Nominal Speed RPM 1370 1383 1385 1340 Max. Airflow m³/h 1537 2034 3640 4817 Sound Pressure level LpA at 3m db(a) 51 55 58 63 Max. Temperature C 45 60 50 60 Motor Insulation Class F F F F Motor Protection IP 44 44 54 54 Capacitor µf 4 6 10 14 Weight kg 16 20 25 30 SOUND DATA Single figure on performance curves are overall inlet LwiA sound power levels, derived from measurements taken in laboratory specifically under ducted conditions. Following is the inlet Lwi sound power levels (db) in eight octave bands maximum airflow (0Pa) : Model 63 125 250 500 1K 2K 4K 8K Overall CDRE 315 84 83 72 66 60 58 57 48 87 CDRE 355 86 88 74 69 63 60 63 55 90 CDRE 400 90 88 79 75 67 64 63 71 92 CDRE 450 88 93 84 79 74 73 74 70 95 The sound power level rating shown are in decibel, referred to 10-12 watts calculated per AMCA International Standard 301. Performance certified is for installation type D-Ducted inlet. Ducted outlet. Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (accessories) The A-weighted sound ratings shown have been calculated per AMCA international Standard 301. Values shown are for inlet Lwi and LwiA sound power levels for installation type D ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Sound pressure level LpA at 3m are not licensed by AMCA international.

Rectangular Cabinet Fan 5 Dimensions Rectangular Cabinet Fans CDRE 315 D C B A D C B IN METRIC CDRE A B C(P.C.D.) D 315 400 450 425 400 355 550 550 525 500 400 600 650 625 600 450 600 650 625 600 NO LIABILITY FOR ERRORS SUBJECT TO TECHNICAL MODIFICATIONS

6 Rectangular Cabinet Fan Rectangular Cabinet Fan CDRD Performance Data & Curves 1200 3 AMCA 210, ISO 5801:2007 p = 1.2kg/m³, 20 C, 1013 hpa 92 1000 Static Pressure, Ps [Pa] 800 600 2 1 82 88 82 84 86 88 400 86 1 CDRD 500 1435rpm 2 CDRD 560 1456rpm 200 83 3 CDRD 630 1471rpm 0 0 2000 83 87 89 4000 6000 8000 10000 12000 14000 Air Volume, Q [m3/h] CDRD 500 CDRD 560 CDRD 630 Voltage V 415 415 415 Frequency Hz 50 50 50 Phase - 3 3 3 Max. Motor Input Watts W 1359 2432 3893 Motor size kw 1.5 3 4 Max. Current A 3.2 6.0 7.9 Nominal Speed RPM 1435 1456 1471 Max. Airflow m3/h 6152 9702 12643 Sound Pressure level LpA at 3m db(a) 63 67 69 Max. Temperature C 40 40 40 Motor Insulation Class F F F Motor Protection IP 55 55 55 Weight kg 65 85 110 Sound Data Single figure on performance curves are overall inlet LwiA sound power levels, derived from measurements taken in laboratory specifically under ducted conditions, Following is the inlet Lwi sound power levels (db) in eight octave bands at maximum airflow (0Pa): Model 63 125 250 500 1k 2k 4k 8k Overall CDRD 500 93 93 86 80 72 71 68 70 97 CDRD 560 94 97 90 81 79 76 73 76 99 CDRD 630 95 99 92 83 81 78 77 77 101 Performance certified is for installation type D Ducted inlet, Ducted outlet, Speed (RPM) shown is nominal. Performance is based on actual speed of test. Performance ratings do not include the effects of appurtenances (Accessories). The A-weighted sound ratings shown have been calculated per AMCA International Standard 301. The sound power level ratings shown are in decibels, referred to 10-12 watts, calculated per AMCA International Standard 301. Values shown are for inlet Lwi and Lwi(A) sound power levels for installation type D : ducted inlet, ducted outlet. Ratings include the effects of duct end correction. Sound pressure level LpA at 3m are not licensed by AMCA International.

Rectangular Cabinet Fan 7 Direct Drive Rectangular In-Line Fan CDRD 500 Dimensions SIDE VIEW FRONT INLET Features The CDRD Cabinet In-line Duct Fan a series of duct mounted in-line centrifugal suitable for supply or exhaust from applications ranging from residential & commercial to industrial. Galvanised steel housing and flanged connections. AIR FLOW A B D D C (P.C.D.) Backward curve centrifugal impellers. Fan units are lightweight and can be mounted at any angle. Motors Type can supplied with directdriven standard TEFC motors. Electrical supply three-phase to suit a wide range of voltages and frequencies. IN METRIC MODEL A B C D CDRD 500 650 710 680 650 CDRD 560 750 785 755 725 CDRD 630 800 860 825 800 NO LIABILITY FOR ERRORS SUBJECT TO TECHNICAL MODIFICATIONS

Systemair India Pvt. Ltd. Plot no. 3, Sector - 31, Kasna Greater Noida-201 308. India Tel. +91 (0120) 4763100 Fax +91 (0120) 4763101 mailbox@systemair.in www.systemair.in Systemair IN/ CDRE/D/MAY2017