OPERATING LIMITS Flow up to: 16 m 3 /h Head up to: 9 m Max. operating pressure: 1 bar Max. suction pressure: 6 bar Temperature range: 15 to + 9 C Max. ambient temperature: + C DN of ports: G1 to G1 1/ MULTISTAGE HORIZONTAL PUMPS pole - 6 Hz APPLICATIONS 9 Pumping of clear non-loaded fluids in the housing, agricultural and industrial sectors: - Transfer - pressure boosting - Sprinkling - Irrigation - Washing station - Draining - Filling (ponds, etc.) - Heating - Air conditioning - Water treatment (demineralization, filtering, etc ). And incorporation in all modular systems. 16 AdVANTAGES - Monobloc pump, compact, economical and silent. - Impellers, hydraulic and pump shaft assembly in stainless steel, pump casing in cast iron, - Motor rolling bearing fitted in the front endshield, amply dimensioned. - Suction rings between very thick cells limitating thermal expansion and eliminating risks of seizing up. - Maximum reliability - high efficiency due to impeller profile limiting the number of stages, shaft size and ball bearing size. 9 15 - Standardized mechanical seals. + 9 C maximum. - Easy installation. 5 36 N.T. N o 11-11- 6Hz/ENG - Ed. 3/6-8 1
muh DESIGN Hydraulic part - Horizontal, centrifugal, non self priming - Multi-stage, from to 7 stages - Axial suction, vertical discharge upwards - Impellers mounted directly on the motor shaft extension - Shaft leaktightness by standardized mechanical seal. Motor - Standard ventilated - Extended shaft end - Single-phase motor with integrated thermal protection, automatic reset; - Capacitor incorporated into the terminal box - Ball bearings of the impeller shaft lubricated for life HYDRAULIC PRESELECTION CHARTS 1 9 8 7 6 5 6 Hz Speed of rotation : 35 tr/mn Windings three-phase : -38 V single-phase : V Frequency : 6 Hz Insulating class : 155 C (F) Protection index : IP 5 3 1 1 m 3 3 m 3 5 m 3 89 m 3 6 8 1 1 1 16 18 STANDARD CONSTRUCTION Main part Material Pump casing EN GJL5 Impellers 3 stainless steel Cells (stage casing) 3 stainless steel Pump shaft stainless steel Cell centring 3 stainless steel Mechanical seal Carbon/silicon carbide Round section joint rings EPDM ethylene propylene Fixing-support bearing EN GJL5 IDENTIFICATION Pump family Nominal flow in m 3 /h No. of stages E = O ring: EPDM V = O ring: VITON M = single-phased M11 = Single-phased 11 V T = three-phased - 3 - E - M / 6 / OEM / XX / B 6 = 6 Hz OEM = Original Equipment Manufacturer Technical definition code Version index
SECTIONAL DRAWING 6-1 3
muh HYDRAULIC PERFORMANCE - 1 AND 3 SERIES - pole - 6 hz 9 17 17 1 m 3 /h 6Hz 9 36 3 m 3 /h 6Hz 8 16 8 35 7 7 6 15 6 3 5 1 1 5 33 13 3 1 3 3 1 1 1 3 1 3 5 6 Ql/min,5 1 Ql/s 1 3 5 6 6 8 1,5 1 1,5 Ql/min Ql/s 3 NPSH (m) m 6 3 NPSH (m) 6 1 N.P.S.H 1 N.P.S.H 1 3 1 3 5 6 P kw 1,,8,6,, 17 16 15 1 13 1 P kw 1,,8, 36 35 3 33 3, 1 3, 1 3 5 6
HYDRAULIC PERFORMANCE - 5 AND 9 SERIES - pole - 6 hz 8 55 5 m 3 /h 6Hz 5 93 98 m 3 /h 6Hz 7 6 5 35 3 9 5 53 5 3 5 15 1 1 5 1 3 5 6 7 8 9 5 1 15 Ql/min 1 Ql/s 1 3 5 6 7 8 9 1 11 1 13 1 15 16 5 1 15 5 Ql/min 1 3 Ql/s N.P.S.H 1 3 5 6 7 8 9 P kw 1, 55 5 53 5 NPSH (m) 6 6 1 3 5 6 7 8 9 1 11 1 13 1 15 16 P kw 1,5 1,,5 N.P.S.H 93 9 NPSH (m), 1 3 5 6 7 8 9, 1 3 5 6 7 8 9 1 11 1 13 1 15 16 5
muh SECTIONAL VIEW OF THE INSTALLATION Suction pump MIN. Suction pump Max. suction head (Ha) and minimum pump head (Hc) at nominal pump flow rate Fluid temperature 1/3 5/9 Ha mcl Hc mcl Ha mcl Hc mcl Niveau high level haut + C 7 --- 7 --- + 5 C 6 --- 6 --- + 8 C, --- 3 --- + 9 C --- 8,1 --- 7 These values do not take into account pressure loss in the suction pipe Ha Niveau low levelbas min.,7m Clapet strainer de foot pied valvede crépine,1m On-load pump on storage tank or town water network (with dry running protection kit) Strainer Crépine Hc Town Réseau water de network ville 6
H ELECTRICAL DATA AND DIMENSIONS L DISCHARGE REF D 3~ 1~ Presse Packing étoupe gland D3 Single-phase Monophasé Moteur motor size taille 71/8 = 16 Moteur motor size taille 63 = 81 ø 1/" H1 H SUC. ASP D1 øm ø 1/" L1 L 58 1,5 7 ø1 18 138 ~ Hz V V A A P capacitor H H1 H L L 1 L M D1 D D3 Weight 1xV 3x/V 1xV 3x38/V kw µf mm mm mm mm mm mm mm mm Kg 1-E-M/6 1 6 3,7 3,5,55 1 16 9 1 33, 156, 1,7 15 1 1 13,5 16,6 13-E-M/6 1 6 3,7 3,5,55 1 16 9 1 35,6 176, 1,9 15 1 1 13,5 17,3 1-E-M/6 1 6 3,7 3,5,55 1 16 9 1 37,8 196,6 13,1 15 1 1 13,5 17,8 15-E-M/6 1 6 5, 5,75 16 16 9 1 39,7 16,8 163,3 15 1 1 13,5 17 16-E-M/6 1 6 8, 9 1,1 3 9 1 37 183,5 16 1 1 13,5,3 17-E-M/6 1 6 8, 9 1,1 3 9 1 6, 57, 3,7 16 1 1 13,5,9 3-E-M/6 1 6 3,7 3,5,55 1 16 9 1 35, 167, 113,7 15 1 1 13,5 15 33-E-M/6 1 6 5, 5,75 16 16 9 1 369,6 191, 137,9 15 1 1 13,5 17,6 3-E-M/6 1 6 8, 9 1,1 3 9 1 18,6 15,6 16,1 16 1 1 13,5 19,7 35-E-M/6 1 6 1,8 1,1 1,5 9 1 33,8 39,8 186,3 16 1 1 13,5,5 36-E-M/6 1 6 1,8 1,1 1,5 9 1 58 6 1,5 16 1 1 13,5 1,5 5-E-M/6 1 6 5, 5,75 16 16 9 1 35, 167, 113,7 15 1 1/ 1 13,5 16 53-E-M/6 1 6 8, 9 1,1 3 9 1 39, 191, 137,9 16 1 1/ 1 13,5 18,8 5-E-M/6 1 6 1,8 1,1 1,5 9 1 18,6 15,6 16,1 16 1 1/ 1 13,5 19,8 9-E-M/6 1 6 1,8 1,1 1,5 9 1 367, 173, 119,7 16 1 1/ 1 1/ 13,5 1-E-T/6 3 6-5 Y38-.6-.6 1.5-1.5,55-19 9 1 33, 156, 1,7 15 1 1 11 16,6 13-E-T/6 3 6-5 Y38-.6-.6 1.5-1.5,55-19 9 1 35,6 176, 1,9 15 1 1 11 17,3 1-E-T/6 3 6-5 Y38-.6-.6 1.5-1.5,55-19 9 1 37,8 196,6 13,1 15 1 1 11 17,8 15-E-T/6 3 6-5 Y38-3.3-3. 1.9-1.9,75-19 9 1 39,7 16,8 163,3 15 1 1 11 18,5 16-E-T/6 3 6-5 Y38-.6-.6.7-.7 1,1-19 9 1 15, 37 183,5 15 1 1 11 19,1 17-E-T/6 3 6-5 Y38-.6-.6.7-.7 1,1-19 9 1 35, 57, 3,7 15 1 1 11 19 3-E-T/6 3 6-5 Y38-.6-.6 1.5-1.5,55-19 9 1 35, 167, 113,7 15 1 1 11 16,8 33-E-T/6 3 6-5 Y38-3.3-3. 1.9-1.9,75-19 9 1 369,6 191, 137,9 15 1 1 11 17,6 3-E-T/6 3 6-5 Y38-.6-.6.7-.7 1,1-19 9 1 393,8 15,6 16,1 15 1 1 11 17,5 35-E-T/6 3 6-5 Y38-6.9-6.6-3.8 1,5-6 9 1 9 39,8 186,3 16 1 1 13,5,5 36-E-T/6 3 6-5 Y38-6.9-6.6-3.8 1,5-6 9 1 58 6 1,5 16 1 1 13,5 1,5 5-E-T/6 3 6-5 Y38-3.3-3. 1.9-1.9,75-19 9 1 35, 167, 113,7 15 1 1/ 1 11 16,8 53-E-T/6 3 6-5 Y38-.6-.6.7-.7 1,1-19 9 1 369,6 191, 137,9 15 1 1/ 1 11 17,6 5-E-T/6 3 6-5 Y38-6.9-6.6-3.8 1,5-6 9 1 18,6 15,6 16,1 16 1 1/ 1 13,5 19,5 55-E-T/6 3 6-5 Y38-7.8-7.5.5-.3 1,85-6 9 1 33,8 39,8 186,3 16 1 1/ 1 13,5,5 9-E-T/6 3 6-5 Y38-6.9-6.6-3.8 1,5-6 9 1 367, 173, 119,7 16 1 1/ 1 1/ 13,5 18, 93-E-T/6 3 6-5 Y38-7.8-7.5.5-.3 1,85-6 9 1 397, 3, 19,9 16 1 1/ 1 1/ 13,5,5 7
muh ACCESSORIES ACSON: ON/OFF control device and protection against lack of water Three-phase motor protection overload cut-out Shut-off valve Strainer foot valve Check valve FEATURES a) Electrical - T types: Three-phase -38 V - 6 Hz - M types: Single-phase V - 6 Hz with capacitor integrated in terminal box. - Motor protection by overload cut-out essential for three-phase motor. - Connections to the motor terminal by packing gland. b) Installation - On the solid base with fixing by foundation bolts. - Suction pump assembly with compulsory strainer foot valve, or on-load pump on storage tank or on town water network with protection system against lack of water. - Pump connection through flexible or rigid piping. c) Packaging Pump supplied in cardboard packaging, without connection accessories. d) Maintenance Replacement of recommended spare parts ( ) subject to wear and tear. Water hammer tank Bladder tank Anti-vibratory sleeves OPTIONS & ACCESSORIES Shut-off valves Check valves Strainer foot valve Anti-vibratory sleeves Suction kit Bladder or galvanized tanks Water hammer tanks ME dry running protection kit ACSON: ON/OFF control device and protection against lack of water 3-phase overload cut-out motor protection, etc. 8 53, bd de la République - Espace Lumière - Bât. 6-783 Chatou Cedex - FRANCE SALMSON Contact : +33 ()8 Fax. : +33 ()1 3 9 8 8 www.salmson.com