M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

Similar documents
M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

M-50/55 Series. Fixed setting flow switch with in-line flow

Adjustable Flow Switches

M-200 Series. High flow, Adjustable flow switch with right-angle flow

M-100 Series. Adjustable flow switch with right-angle flow

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

M-100 Adjustable flow switch with right-angle flow

M-2800 Series. Inline Ultrasonic Flow Meter. Description. Measurement Principle. Key Features. Applications

MFC Integrated Flow Control Module For Slurries and Chemicals. Key Features. applications.

Description. Measurement Principle. Key Features. Applications. Malema SUMOFLO. 1 Barb Single-Use Sensor for g/min

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Shuttle Type Switches For Moderate to High Liquid Flow Rates

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Ar-Mite TM Low Flow Armored Flowmeter

RS85 Vibrating fork level switch

Operating Instructions

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Metal tube variable area flowmeter for gases, liquids and steam

Fisher 2100 Pneumatic and 2100E Electric Liquid Level Switches

Plastic tube variable area flowmeter for liquids and gases

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

LFC Integrated Flow Control Module. Description.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

Fisher i2p 100 Electro Pneumatic Transducer

General Specifications

Direct-acting 3/2 way plunger valve

Flow Switches INTRODUCTION

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

8000 Series Liquid Flow Meters

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

KDM ARMORED FLOW METER & SWITCH

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Flow Switches INTRODUCTION

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Mini pressure switch Stainless steel switch enclosure Model PXS

Technical Datasheet. GR Series - Flameproof Pressure Switch Models: GR2 & GR4. GR Series. Key Features. Series Overview. Product applications

8000 Series Liquid Flow Meter

SATRON VT Pressure Transmitter

Load and Motor Switches, Load-Break Switches Series 8549

PISTON STYLE GAUGE. Mid-West Instrument

INSTALLATION INSTRUCTIONS SWITCH HOUSING SUPPLIED ONLY AS AN ASSEMBLY OF ENCAPSULATED SWITCH & LEADS. FLOAT SUPPLIED ONLY WITH ENCAPSULATED MAGNET.

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Flow Monitors Excess Flow Valves Flow Meters. ChemTec.com

Mini temperature switch Stainless steel switch enclosure Model TXS

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Flow switches Series AD/VH

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

Ex m Solenoid Operator Type 0519

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Micro Motion ELITE High Capacity Coriolis Flow and Density Meters

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Magnetic-inductive flow meter for hazardous areas

Compact pressure switch Model PCS

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Accord DS/DM Series UltraSwitch Switch box

Control switch/load disconnect switch Series 8008

Miniature I/P, E/P Transducer

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

SP/SF Series Flow Switches

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Temperature Products. Temperature Products

Glass Tube Flowmeter Model GT1000

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

SATRON VDt Differential Pressure Transmitter

GA 24 Heavy-duty variable area flowmeter

Micro Motion Model D and DL Coriolis Flow and Density Meters

Check Valve AP64 P.149. Vacuum Generator Vacuum Generator Module Vacuum Generator Module AP7 & 70 AP71 AP72. Flow Switch Flow Switch (For high flow)

Flap-Type Flow Meter Prall

T95 Load Cell Assembly for Silo, Tank & Vessel Weighing and Axle Weighing

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Ex Pressostat EXPK 944/947/953. Applications. Features

SKINNER Intrinsically Safe Series Four-Way

Digital Positioner 8049

Relative and absolute pressure transmitter type 528

Fisher 3660 and 3661 Positioners

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

General Specifications

Micro Motion 7827 Digital Viscosity Meter

K - Flow Meter with Float

Micro Motion. CMF400 Sensor. Installation Instructions. Quick Reference Guide P/N , Rev. D May 2003

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Transcription:

Explosion Proof Flowswitch with In-line Flow Key Features Well suitable for corrosive and noncorrosive liquids or gases UL recognized for hazardous location ATEX certified for intrinsic safety and encapsulation and dust environments Community Europe compliant Universal Mounting available Description The M-60X Explosion proof Series low flow, flow switches monitor increasing and decreasing flow. They utilize a single moving part which responds to fluid (liquid or gas) flowing within a system. These switches are suitable for a wide range of applications in industrial, biomedical and OEM products. The flow monitors operate only when fluid flows is absolutely established. Operating Principle The operating principle is based on a free floating magnetic piston which responds only to the motion of fluids within the line, not to static or system pressures. In the presence of fluid flow, controlled movement of the piston actuates an external hermetically sealed reed switch thus opening or closing the required signal circuit. This signal can be used to actuate audible or visual alarms as well as relays, or other controls. Piston travel is short which insures low hysteresis. Pressure drop across flowswitch varies from 0.035 to 2 psi (at maximum flowrates for air and liquid). Universal mounted units are outfitted with a spring which resets the piston. The spring is held in place using a perforated disc. Applications Illustrated is the M-60X model with 1/4 ports. Custom Version Available Malema welcomes the opportunity to apply its flow sensor experience to work for its customers. Please contact the factory for any special requirements; such as ports, extreme temperature and pressure capabilities, etc. Gas panels Hazardous fluid systems Pollution control monitors Gas leak monitors Sample flow monitoring Purge Flows

Material Versions Housing Pistons Orifice Plate or disc (Only in Universal Mounting Version) Spring Retaining ring 316 SS 316 SS 316 SS Stainless Steel Stainless Steel Other materials available upon request; only the 316SS is Cenelec Certified. Calibration range Air Water 300-55,000 scc/min 10-1,600 ml/min For lower and higher trip points contact factory. Maximum flow through switch are higher. Specifications Set Point Accuracy ± 10% maximum Hysteresis 15% Repeatability ± 2% Port size 1/4 FNPT 2

Standard Specifications Maximum Operating (psig) 3,000 Burst (psig) 5,000 Maximum Operating temperature 175 C (347 F) See Design Consideration/Construction section Electrical Specifications Reed Switch data (Electical Ratings) 10 Watts SPST or 3 Watts SPDT (Hermetically Sealed) UL Recognized. File E47258 Operating temperature -40 C to 175 C Switch voltage Breakdown voltage DC Resistive AC Resistive Switching current Carrying current Lead Wires Lead Wires Color 200 Vdc (170 Vdc for SPDT) 250 Vdc (200 Vdc for SPDT) 10 VA (3 VA for SPDT) 10 Watts (3 Watts for SPDT) 0.5 A (0.25 A for SPDT) 1.2 A (0.5 A for SPDT) No 24 to 18 AWG. 18 length, Polymeric UL Recognized (Belden cable or special shielded cable is available) SPST: 2 blue wires SPDT: Green - Common, Yellow - Normally Closed, Orange - Normally Open Reed Switch Ratings as Recognized by UL SPST SPDT 120 Vac 24 Vdc 50 Vdc 120 Vac 10 Vdc 24 Vdc 0.1 A general purpose 0.25 A resistive 0.25 A resistive 0.1 A general purpose 0.25 A resistive 0.1 A resistive 3 Installation and Maintenance The standard switch has to be mounted vertically in the position shown above for normally open conditions and inverted position for normally closed conditions. When inverted, the switch set point will change by ± 5%; please use the product in the orientation it was calibrated (as indicated by reading the label). Universal units can be mounted horizontally or vertically. Please advise mounting orientation while ordering, so that the factory can calibrate in the required orientation as calibration does change slightly when changing orientation. Adequate filtration and sealing procedures should be used when mounting in flow lines. For detailed directions, please refer to our Installation and Maintenance sheet.

Design Considerations / Construction The M-60X Series comprises a Body, piston, and Retaining rings. Selecting a flowswitch begins with selecting the body; this series is available in 316 Stainless Steel, Monel 400, or Hastelloy 276. The M-60X series contains one moving part (i.e. the piston) and two retaining rings that are in the fluid path. Construction of the piston is important from a design perspective. We manufacture three types of pistons (it is critical to select the correct piston for your application): 316 Stainless Steel, PTFE encapsulated, and Special All-Metal Piston. 1. The standard piston is a 316 Stainless Steel piston with epoxy to hold the magnet in place. This piston is recommended for non-aggressive fluids and inert gases. Stainless Steel retaining rings are typically used with this piston type. 2. The second piston that is available is PTFE Encapsulated. The piston is a magnet that has PTFE molded around it and then machined to the appropriate configuration. These pistons are primarily used in PTFE flow switches and also in other flow switch bodies (typically 316SS and Acrylic bodies) where customer prefer a piston that does not have epoxy in the fluid path; as well as a piston that is impervious to aggressive fluids and gases. This piston is highly recommended for medical applications. Hysteresis on these pistons does tend to be slightly higher (10 to 15%) than metal piston due to frictional effects, weight, and surface adhesion considerations. Prior to selecting this piston, fluid temperatures, and fluid compatibility with PTFE must be taken into account because certain aggressive chemicals at specific temperatures tend to swell PTFE causing the piston to change shape resulting in failure of the product. Stainless or PTFE retaining rings can be used with this piston. 3. The third piston that is available is a Special All-Metal piston with no epoxy (only available in 316SS). This piston is fabricated in a proprietary process with only one weld seam (leak tested) which presents an all 316SS surface to the fluid path. This piston is recommended for those applications where the piston could experience a lot of cycling wear. This piston has been tested to 250,000 cycles at 125 psi. Stainless Steel retaining rings are recommended for this piston type for low pressure applications and an orifice disc (See Universal Mounting Diagram) is recommended for high pressure (125 psi) applications. Fixed Flow Setting Information This model is a FIXED flowswitch. The flow set point is fixed at the factory and is NOT field adjustable. Proper calibration of the set point requires the following information. When purchasing a flowswitch, use the Set Point Calibration form or provide the following information on the purchase order. Calibration set point Increasing or decreasing flow Fluid type (i.e. liquid or gas) Density or specific gravity Viscosity System pressure and temperature Flow direction (i.e. upward or downward) Mounting orientation (i.e. horizontal or vertical) 4

Certifications UL and Canadian UL Recognized for use in Class I (Groups A, B, C) and Class II (Groups E,F,G), all divisions, hazardous locations. File E153446. Atex Certifications for Encapsulation and Intrinsic Safety (Via ISSeP) IECEx Certifications for Encapsulation and Intrinsic Safety Protection (Via UL) Intrisic Safety (Via ISSeP) Electrical parameters Gases: Dusts: II 1 G Ex ia IIC T6 T3 Ga II 1 D Ex ia IIIC T95 C T175 C Da Ui 30 V Pi 0,7 W Ci = 40pf Li = 4 µh Encapsulation (Via ISSeP) Electrical parameters Gases: Dusts: II 2 G Ex mb IIC T6 T3 Gb II 2 D Ex mb IIIC T95 C T175 C Db Um = 250 V and Im = 1 A Ambient temperature range Temperature class for Gas Temperature class for Dust - 40 C to + 60 C T6 T95 C - 40 C to + 75 C T5 T95 C - 40 C to + 117 C T3 T140 C - 40 C to + 149 C T3 T175 C -EX ia: EN 60079-0 : 2012 (IEC 60079-0 : 2011) EN 60079-11 : 2012 (IEC 60079-11 : 2011) -EX mb: EN 60079-0 : 2012 (IEC 60079-0 : 2011) EN 60079-18 : 2009 (IEC 60079-18 : 2009) 5 EN 60079-26 : 2007 (IEC 60079-26 : 2006) CE Mark IECEx EMC (EMC directive 2004/108/EC) Intrinsic safety EN 61326-1:2006 IECEX cert # : UL 13.0065X EN 61000-4-2:1995/A1:1998/A2:2001 Code : Ex ia IIC T6, Ex ia IIIC T80 C Da EN 61000-4-3:2006 Encapsulation safety EN 61000-4-4:2004 IECEX cert # : IECEx UL 13.0067X EN 61000-4-6 :2007 Code : Ex mb IIC T6 Gb, Ex mb IIIC T80 C Db EN 61000-4-8 :1994/A1:2001 Safety (Low-voltage Directive 2006/95/EC) EN 61010-1:2001 Check http:///certifications for more information.

Cut Dimensional Drawings Illustrated is the M-60X model with 1/4 ports and SPDT switch. For Reference Only 6

Ordering Information Model Ordering Code M-60X - * * * - * * - *** Option - Material S 316SS Port 2 1/4 Switch 3 SPDT - Mounting 0 Standard (Vertical) 1 Universal Mounting (with disc and spring) 0 316SS with epoxy Piston 1 PTFE encapsulated 2 All-316SS (no epoxy) - XXX Unique PN Identifier 2014 Malema Engineering Corporation. All rights reserved. Malema, Malema Sensors, and Malema Engineering Corporation are service marks of Malema Engineering Corpration. All other trademarks are property of their respective owners. Malema supplies this publication for informational purposes only. While every effort has been made to ensure accuracy, this publication is not intended to make performance claims or process recommendations. Malema does not warrant, guarantee, or assume any legal liability for the accuracy, completeness, timeliness, reliability, or usefulness of any information, product, or process described herein. We reserve the right to modify or improve the designs or specifications of our products at any time without notice. For actual product information and recommendations, please contact your local Malema representative. 7 Corporate Headquarters West Coast Headquarters Asia Pacific Headquarters 1060 S Rogers Circle Boca Raton, FL 33487 2329 Zanker Road San Jose, CA 95131 29 Woodlands Industrial Park E1 #02-06 Northtech Lobby 1 Singapore 757716 P: (561) 995-0595 F: (561) 995-0622 P: (408) 970-3419 F: (408) 970-3426 P: (65) 6482-3533 F: (65) 6484-4231 DOC# M-60X DS 418121