SERIES 670E End-of-Line Deflagration Flame Arrester

Similar documents
SPRING LOADED VENTS. Set Points of 3 PSIG and Above PROTECTOSEAL

FRP VENTS. Fiberglass Reinforced Plastic Vents... No Exposed Metal Components. Distributed by Relevant Solutions relevantsolutions.

Table of Contents. 1. Fuel Oil Fill Box 2. Remote Alarm Panel 3. Level Switch Assembly

94407 Horizontal Inline Deflagration Flame Arrester

94406 Vertical Inline Deflagration Flame Arrester. Features

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 300. Product Description. (Vertical, in-line, deflagration)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL (IOM) Model 6A00. Inline Deflagration Flame Arrestor SECTION I

VAREC 5910B AND 5920B SERIES RELIEF VALVE WITH FLAME ARRESTER

Installation, Operation and Maintenance Manual for Flame Check

Installation, Operation and Maintenance Manual for Model 7758A Deflagration and Detonation Flame Arrester

VAREC 5810B AND 5820B SERIES RELIEF VALVE WITH FLAME ARRESTER

Flame arresters 4301A/4319A ATEX Approved

Installation, Operation & Maintenance. Model 7678 End of Line Deflagration Flame Arrester ATEX Certified

This document is a preview generated by EVS

INSTALLATION AND MAINTENANCE

VAREC 5810B/5820B Series. Relief Valve and Flame Arrester

Flame Arrester. ergil. ATEX approved. Storage Tank Protection Equipment. Model Number 320. Product Description. (Vertical, in-line, detonation )

Instructions for installation, service and maintenance 1. INTRODUCTION APPLICATION TECHNICAL DATA, IDENTIFICATION...

COVER EQUIPMENT. VAREC BIOGAS 400W Series EMERGENCY RELIEF MANHOLE COVERS

Installation Instructions. Install Hubs Set Spacing Install Element FINISHED BORE INTERFERENCE FIT. Step 1 - HUB INSTALLATION

EN-DFA Series Detonation Flame Arrestor (ATEX Approved)

Model 6A00 TECHNICAL BULLETIN 6A00 - TB Inline Deflagration Flame Arrestor

Hazardous Location Enclosures INDEX. Hazardous Location Enclosures HAZ-2

Flame-transmission-proof KITO devices for storing and transporting combustible fluids, vapours and gases

Installation, Operation & Maintenance. Model 7688 In Line Deflagration Flame Arrester. ATEX Certified

Zone 1 Linear Range - Installation Guide

HAZMAT PUMPS TUP, GUP, IN EX explosion proof up to 620 l/min, up to 2.0 bar

Operating Instruction Inline Detonation Flame Arrester

PASSIVE OPERATION Completely self-contained with no reliance on power supplies, sensors, actuators or any external components.

In-Line Detonation Flame Arrester PROTEGO DA-CG

Installation, Operation & Maintenance of the In-Line Flame Arrestor Model L76L-UF

Floodlight Range Installation Guide

Condensate Drain Valve AK 45. Original Installation Instructions English

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Model 7A00 7A00 - TB TECHNICAL BULLETIN. Detonation Flame Arrestor

ANDERSON GREENWOOD TYPE 4410 SIDE ENTRY ATMOSPHERIC VACUUM RELIEF VALVES

Ex m Solenoid Operator Type 0519

In-Line Detonation Flame Arrester PROTEGO DA-SB. for stable detonations and deflagrations in a straight through design with shock tube, bidirectional

Protection & Safety Equipments For Storage Tanks. Pressure / Vacuum Relief Valves, Flame Arresters, Free Vent, Gauge Hatch.

Type S030. Operating Instructions. Symbols used. INLINE fitting. Bedienungsanleitung Manuel d'utilisation

DETONATION FLAME ARRESTER MODEL 7658A

Model 5000 Level Controller

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

DFA Series Detonation Flame Arrestor (USCG/ATEX Approved)

Easy Riser swing check valve Models E-1 & F-1

Instructions for Installation, Operation, Care and Maintenance

ILED Aquarius Illuminated Windsock. User Manual

Inspection and Maintenance of Flame Arresters

Flame Arrestor Design and Application Data

High voltage flameproof induction motors The simplest solution for hazardous environments

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Temperature Switches. General Instructions

EU Mutual Recognition Technical Requirements

Instructions for Installation, Operation, Care and Maintenance

PROTEGO Detonation Flame Arresters. Volume 4. for safety and environment

Operating Instructions Inline Detonation Flame Arrester and

TECHNICAL DATA 1-1/2 (dn40)

Available in aluminum (type 356), carbon steel, stainless steel and other materials.

VALIADIS S.A. HELLENIC MOTORS

Flame arresters/vents

Reflex ex separator. Exvoid / Exvoid HC (HiCap) Exdirt / Exdirt HC (HiCap) Extwin /Extwin HC (HiCap) Operating manual

ATMOSPHERIC RELIEF VALVE

These installation and maintenance instructions must be read in full and completely understood before the installation!

UZK12.261, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 26AH 1/10.

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

manual addendum ROBUS Ex

TECHNICAL DATA OBSOLETE

Operating & Maintenance Manual For Steam Conditioning Valve

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

Instruction Manual. Ex-Time 40 / 50

BMRX Series ROTARY LEVEL CONTROL

Model DFA Detonation Flame Arrestor. Model DFA North America Only. Table of Contents. Introduction WARNING. Product Description

Model DA05 Model DA07 Model DA10

7 Series Flame Arrestor

GL Ludemann Y-Strainers

Installation, Operation and Maintenance Manual for Pressure/Vacuum Relief Valves

Rev. Apr. 2/02 !# " " $%# &&% #&% #&&% &% *!)

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

PROTEGO Detonation Flame Arresters. Volume 4. Volume 4. for safety and environment

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

8 Series High Pressure Deflagration Flame Arrestor

GLASS LINING TECHNOLOGIES. Bottom Outlet Valves

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Declaration of Conformity as per Directive 97/23/EC

"N-1-A" REDUCING VALVE, Part No with "N" REDUCING VALVE PORTION, Part No

Special Radial piston pumps Type SRK-ATEX

This document is a preview generated by EVS

List Price. Mult. Sym. C Dim. Single Phase

1/4 thru 300 Hp NEMA 48 thru 449TY. List Price. Mult. Sym. C Dim. Single Phase

Chain-saws (combustion engine powered)

The 7100B Series is designed to protect low pressure storage tanks and systems from being overpressured. Introduction

Features 1. Differential Latch-type, lightweight, dependable

SAFE USE AND HANDLING OF HOSES AND FLEXIBLE CONNECTIONS IN THE SOLVENTS INDUSTRY

PTS SERIES With AE402 Indicator

Terminator ZP/FAK-4L Kit Electrically Heated TubeTrace Bundles

UZK24.071, UZO GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Fisher SS-263 Volume Booster

ACE Variable Frequency Drive System

YT-720 SERIES. Rotork YTC Limited VERSION 1.07

Transcription:

SERIES 670E PROTECTOSEAL CAUTION: If any questions arise concerning the proper installation or maintenance of our products, please contact Protectoseal or one of our Authorized Representatives. When installing any Protectoseal device, the legal, corporate and advisory safety regulations and procedures appropriate for the specific installation site must be fully understood and followed. CLASSIFICATION: The Protectoseal 670E Series Flame Arresters are classified as s. They are suitable for arresting an unconfined deflagration propagating into a vessel or enclosure. The markings on the arrester identify restrictions concerning the use of a specific arrester with respect to gas/vapor group and maximum operational temperature/pressure. OPERATIONAL LIMITS: The Protectoseal Series 670E Flame Arresters are suitable for use under the following limitations: Materials may include aluminum, carbon steel or stainless steel Maximum Operational Temperature = 60 C (40 F) Maximum Operational Pressure =. bar (5.9 PSIA) Explosion Group (Ex. G.) = As marked on the arresters: Group IIB3 or Group IIA Not for use in stabilized burning situations MARKINGS: Each Protectoseal 670E Series Flame Arrester includes two labels: an Identification Label and a Warning Label. Identification Label The Identification Label includes:. SIRA certificate number 2. Deflagration arrester and gas/vapor explosion group designation 3. Burn time designation 4. Maximum operational temperature 5. Maximum operational pressure 6. Model number and unique serial number 7. Standards designations 8. SIRA identification number Warning Label The Warning Label indicates that limitations to the installation and application criteria for the arrester exists and identifies type designation according to ISO 6852. DEF - indicates that the arrester is a deflagration flame arrester L u /D = na - indicates that the arrester is suitable for end-of-line applications only BC: c - indicates a rating of no burn time Ex.G - indicates the appropriate explosion group that the arrester is suitable for (IIB3 or IIA as appropriate) T o = 60 C - indicates a maximum operational temperature of 60 C (40 F) p o =. bar - indicates a maximum operational pressure of. bar (5.9 PSIA) www.protectoseal.com

Installation & Maintenance Series 670E WING NUTS MAINTENANCE PROCEDURE:. Loosen the wing nuts on the weatherhood. Remove the weatherhood to expose the flame arrester element. FLAME ARRESTER ELEMENT INSTALLATION PROCEDURE:. Check carefully to insure that no packing materials remain on or inside the arrester housing or element. 2. Make sure that the wing nuts mounting the weatherhood to the housing are hand tightened securely. 3. Mount the arrester to the appropriate end-of-line, outlet connection using thread sealant or gasket compatible with service conditions. 4. Arrester should be located at least 0.3 metres ( foot) from equipment or structure that could impede access to the arrester or impair flow through the device. MAINTENANCE: WEATHERHOOD Protectoseal recommends that our products be inspected and maintained according to the normal maintenance schedule of the facility. At a minimum, maintenance should be conducted annually. More frequent maintenance may be required, and should be scheduled, for unusual service conditions. CAUTION: When maintaining any Protectoseal device, the legal, corporate and advisory safety regulations and procedures appropriate for the specific installation site must be fully understood and followed. CAUTION: Tank vapor space pressure or vacuum should be relieved before any maintenance operations are undertaken. 2. The arrester element assembly consists of a series of circular plates, separated by precise embossed teats or spacers. 3. Inspect the arrester assembly. The passages between the individual plates should be even and clear of debris. Blow out any loose dirt or foreign material. If necessary, the arrester assembly may be removed from the tank and immersed in a suitable solvent to remove gums and deposits. CAUTION: Do not remove plates from stud. Do not bend plates. Contact Protectoseal if any questions arise. 4. If plates are damaged or if spacing between plates is uneven, the arrester should be removed from service immediately and replaced. 5. Reinstall weatherhood and secure by hand tightening the wing nuts. PROTECTOSEAL Safety Without Compromise 225 Foster Ave., Bensenville, IL 6006-690 P 630.595.0800 F 630.595.8059 info@protectoseal.com www.protectoseal.com 206 The Protectoseal Company VM-670E/

PROTECTOSEAL Safety Without Compromise The Protectoseal Company EC Declaration of Conformity Manufacturer: The Protectoseal Company 225 Foster Avenue Bensenville, IL 6006 USA Quality Assurance Notification Certificate Number: SIRA 0 ATEX M458 issued by SIRA Certification Service (Notified Body No. 058) Rake Lane Eccleston, Chester, CH4 9JN, UK The Protectoseal Company herewith declares that the equipment detailed below is in conformity with the applicable provisions of the ATEX Directive 204/34/EU and has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive. Equipment: Type 670E Range of End-of-Line Flame Arresters EC Type Examination Certificate #SIRA 09ATEX996X issued by SIRA Certification Service (address as listed above) Notified Body No. 058, in accordance with Article 7 of Directive 204/34/EU. Applied Standards/Marking: EN ISO 2874:200 ISO 6852:2008 II IIA, IIB3 058 Michael Collins Engineering Manager Engineering Document Number: SPEC-670E Revision: 6 Issue Date: January 4 th, 208

SERIES 670E Suitable for use with Explosion Groups IIB3 or IIA (NEC Groups C or D) Vapors PROTECTOSEAL Sizes DN 25 (") through DN 50 (6") Conforms to the latest ATEX Directive, ISO 6852 Suitable for use with Explosion Groups IIB3 or IIA (NEC Groups C or D) Parallel plate-type flame arrester Operating temperatures up to +60 C (40 F) Available with threaded (FNPT) or flanged (DIN, ANSI) connections Easy inspection and maintenance Weatherhood protects against environmental conditions Available in Aluminum, Steel and Stainless Steel OBJECTIVE The Series 670E Flame Arresters are designed to provide flame stopping protection for a tank s vapor space when mounted to the end of a tank nozzle leading directly to atmosphere. Maximum operating pressure is. bara (5.9 PSIA). The arresters prevent a flame front generated by an unconfined deflagration occurring outside the tank from propagating into the vapor space. Arresters are not for use instabilized burning situations. VAPOR GROUPS The arresters as designated by model number, are intended for use with vapors equivalent to International Electrotechnical Commission Explosion (IEC) Groups IIB3 or IIA, National Electric Code (NEC) Group C or D. TECHNIQUE The arrester is mounted on the end of a vent pipe from the tank. Vapors are allowed to escape into the atmosphere and air can be drawn into the tank through the specially designed flame arrester grid assembly. If an ignition source outside the tank is encountered, the flame arrester provides protection for the tank contents. SPECIAL FEATURES Easy Inspection, Installation and Maintenance. Design and light weight of unit permit easy, convenient handling for inspection, installation and maintenance. The weatherhood is readily removable by loosening just a few wing nuts. Automatic Condensate Drainage. Vertically mounted, circular plate-type flame arrester is employed for self-drainage of condensate. This prevents accumulation of condensate subject to freezing and consequent clogging of the arrester under low temperature conditions. Positive Flame Arresting. The Series 670E employs a precisely-spaced, circular plate type flame arrester to protect tank contents by preventing the propagation of fire into the tank. Precision embossings or spacers provide correct gaps for flame arresting function. Plates are fabricated from heavy gauge stainless steel to resist distortion and bending. Sizes Available. DN 25 ("), DN 50 (2"), DN 80 (3") and DN 00 (4") and DN 50 (6"). Please refer to dimension chart on reverse for flange connection options. Test Lab Listings. Conforms to the latest ATEX Directive, ISO 6852. Refer to Protectoseal Series 670/6670 for Underwriters Laboratories (UL) Listed arresters. PRO-FLOW Sizing and Selection Software. Use PRO-FLOW to calculate flame arrester flow requirements in accordance with API 2000, ISO 28300, NFPA 30 and OSHA 90.06. Quality Assurance. Each unit is inspected to meet Protectoseal s high standards prior to shipment. CONSTRUCTION A comprehensive range of materials is offered as shown in the chart below. Available Options. Material certifications for castings Nipple/ Flame Arrester Series Body Hood Flange Grid Assembly A670E Aluminum 36 S.S. Aluminum 36 S.S. F670E 36 S.S. 36 S.S. 36 S.S. 36 S.S. S670E Steel 36 S.S. Steel 36 S.S. Please refer to charts on reverse for ordering options. Note : Hood on 6" size is constructed of Steel. www.protectoseal.com

Specifications DN 25 ("), DN 50 (2"), DN 80 (3") & DN 00 (4") Sizes FNPT or Nipple and Flange Connection Suitable for use with International Electrotechnical Commission (IEC) Groups IIB3 or IIA (NEC Groups C or D), as designated by model number Series 670E DN 50 (6") Size Flange Connection E,N Looking for a UL Listed Group D Arrester? E,N SERIES 670E PART NUMBERING SYSTEM D DN 25 ("), DN 50 (2"), DN 80 (3") & DN 00 (4") Sizes DIGIT # 2 3 4 5 6 7 8 9 Material A Aluminum Body, 36 S.S. Element & Hood F 36 S.S. Body, Element & Hood S Steel Body, 36 S.S. Element & Hood 2 & 3 Series No. 67 4 Size DN 25 (") 2 DN 50 (2") 3 DN 80 (3") 4 DN 00 (4") 5 Type E 6 Connection FNPT 2 ANSI 25# FF Flange (Aluminum) ANSI 50# RF Flange (Other Materials) 3 DIN PN 6 FF Flange (Aluminum) DIN PN 6 RF Flange (Other Materials) 7 Flange / Nipple 0 None (FNPT Connection) 36 S.S. (Use with Prefix F ) 2 Steel (Use with Prefix S ) 3 Aluminum (Use with Prefix A ) 8-9 Vapor Group C Explosion Group IIB3 (NEC Group C) D Explosion Group IIA (NEC Group D) DN 50 (6") Size DIGIT # 2 3 4 5 6 7 8 9 Material A Aluminum Body, 36 S.S. Element & Hood F 36 S.S. Body, Element & Hood S Steel Body & Hood, 36 S.S. Element 2 & 3 Series No. 67 4 Size 6 DN 50 (6") 5 Type E 6 Connection ANSI 25# FF Flange (Aluminum) ANSI 50# RF Flange (Other Materials) 2 DIN PN 6 FF Flange (Aluminum) DIN PN 6 RF Flange (Other Materials) 7 Flange / Nipple 36 S.S. (Use with Prefix F ) 2 Steel (Use with Prefix S ) 3 Aluminum (Use with Prefix A ) 8-9 Vapor Group C Explosion Group IIB3 (NEC Group C) D Explosion Group IIA (NEC Group D) PART NO. EXAMPLE: Digit #: 2 3 4 5 6 7 8 9 F 6 7 2 E 3 - C Description: Body, Element & Hood - 36 S.S. Size - DN 50 (2") Connection - DIN PN 6 RF Flange Flange / Nipple - 36 S.S. Vapor Group IIB3 (NEC Group C) DIMENSIONS (Please refer to numbering system above to complete Part No. NOTE: Dimensions shown are for reference only, contact Factory for certified drawings.) Connection Ht Dia B.C Dia. Holes Type Part. No. FNPT ANSI DIN 6 PN A C D E N Approval 67E0-9 " - - 73mm (2.88") 73mm (2.88") - - - 67E2 7-9 - " - 2mm (4.4") 73mm (2.88") 80mm (3.3") 6mm (.63") 4 67E3 7-9 - - DN 25 2mm (4.4") 73mm (2.88") 85mm (3.35") 4mm (.55") 4 672E0-9 2" - - 7mm (4.63") 50mm (5.88") - - - 672E2 7-9 - 2" - 78mm (7") 50mm (5.88") 20mm (4.75") 9mm (.75") 4 672E3 7-9 - -- DN 50 78mm (7") 50mm (5.88") 25mm (4.9") 8mm (.72") 4 673E0-9 3" - - 203mm (8") 50mm (5.88") - - - 673E2 7-9 - 3" - 25mm (9.88") 50mm (5.88") 52mm (6") 9mm (.75") 4 673E3 7-9 - - DN 80 25mm (9.88") 50mm (5.88") 60mm (6.3") 8mm (.72") 8 674E0-9 4" - - 87mm (7.38") 84mm (7.25") - - - 674E2 7-9 - 4" - 238mm (9.38") 84mm (7.25") 9mm (7.5") 9mm (.75") 8 674E3 7-9 - - DN 00 238mm (9.38") 84mm (7.25") 80mm (7.09") 8mm (.72") 8 676E 7-9 - 6" - 330mm (3") 34mm (2.38") 24mm (9.5") 22mm (.87") 8 676E2 7-9 - - DN 50 330mm (3") 34mm (2.38") 240mm (9.45") 22mm (.87") 8 Superscripted numbers refer to digits as indicated in the Part Numbering System chart. See Series No. 670/6670 D ATEX Directive 94/9/EC Standards EN 2874 & ISO 6852 206 The Protectoseal Company V-670E/2