Pre-Delivery Instructions

Similar documents
Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners. DATE INSTALLED: DEALER:

Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of Hot Spring spa owners.

Spa Location and Preparation 4-5. Wood or Synthetic Deck Installation 6. Delivery Access Backyard Delivery 7. How To Measure For Backyard Delivery 8

Pre-Delivery Guide. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free

Owner s Manual. Important!

PRE-DELIVERY GUIDE 2011

Pre-Delivery Guide.

PRE-DELIVERY GUIDE How to make the delivery and installation of your new hot tub fast, easy, and trouble-free

LTR , Rev. P 1/14/15

saratoga spas ADVANCE DELIVERY GUIDE Key steps to making the delivery and installation of your new spa smooth and hassle-free

INSTALLATION INSTRUCTIONS

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

Buyers Guide. You Deserve It. Helping You Find The Perfect Hot Tub!

CHAPTER V RESIDENTIAL WIRING

PART B BRAND SPECIFIC MANUAL

COMMERCIAL QUICK REFERENCE

VPL-SH1 Vertical Platform Lift

Installation Manual. CS9300 Professional Series Landscape Lighting System

Installation Manual CS9300-LED. Professional Series Landscape Lighting System

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Step 1. PLANNING FOR THE INSTALLATION TOOLS REQUIRED

INSTALLATION AND OPERATING INSTRUCTIONS

PowerMaster MODEL MBG. Installation Manual U L R UL 325 AND UL 991 LISTED MEDIUM DUTY BARRIER GATE OPERATOR TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

IntelliTouch Pool and Spa Control System Load Center and Power Center

poollux Power plx-pw60 & plx-pw100

SECTION VII METERING INSTALLATIONS

Service Requirements

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts

Professional Séries. Professional Séries. Model T03828 SUBMERSIBLE SUMP DUPLEX SYSTEM SUBMERSIBLE SUMP DUPLEX SYSTEM. 1/3HP 2400 GPH Head of 20 (6 m)

10 Commercial, Industrial, Agricultural Services

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Manual. For. PWC 3000 Boat Lifts

PRE-PLUMBED SEWAGE SYSTEM

2016 Photovoltaic Solar System Plan Review List

WARNING. Important Notice

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Installation Manual CS9100-LED. Professional Series Landscape Lighting System

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Electric Vehicle Charging Station

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Installation Manual. For. Trident Boat Lifts

Placement on the fireground simply refers to how and where an apparatus is placed at the scene.

MASTERsine Inverter PXA Series Installation Guide

Metering and Service Installation:

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

WSB clean: Installation Manual

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

INSTALL SERVICE- ENTRANCE SYSTEMS

MODEL D-SBG Single Arm Barrier Gate Operator

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

LT Charging Cart for Laptops

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

A Homeowner s Guide to Natural Gas Service

Q-VAULT Installation Instructions. Q-Tran, Inc. Milford, CT

HERCULES II DC OWNER S MANUAL HERCULES II DC RESIDENTIAL & COMMERCIAL

City of Manhattan Beach Community Development

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

PRE-DELIVERY. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

SOLID WASTE AND RECYCLING ENCLOSURE STANDARDS

Installation Instructions: ACCENT SYSTEM

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Service Requirements

ALL PURPOSE CNC/HEAVY DUTY

A B C D E F. b.tools Required (supplied by others) 3/16" Drill Bit 3/8" Wrench Phillips Head Screwdriver

Corrections most seen on plan review October 18, 2017 David Rankin Seattle Department of Construction and Inspections

Installation Manual. For. Hi-Speed Alumavator / Platinum Vertical Boat Lifts

Standby Electric Generators for Alaskan Residences. Advice & Installation

Chapter 8 Interior Wiring and Lighting

Automated Trash and Recycling Collection System

Gold Luxury-Lift. la-z-boy.com. operating instructions. instrucciones de operación. instructions. power recliner.

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

Contents. Delivering your Canadian Spa. Pre-Delivery Guide.

Installation Manual. Rev

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

8300 Series Installation Guidelines

NEW SERVICE HANDBOOK COMMERCIAL & IRRIGATION SUPPLEMENT

UPPCO SERVICE MANUAL

Instruction & Owner s Manual

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/14/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

CLEAN POWER TM CPS Series Operator s Manual

Table of Contents. Electrical Service Requirements. 1. General Requirements

OVERHEAD SERVICE. Items to consider

SPRINGVILLE CITY ELECTRICAL REQUIREMENTS & STANDARDS MANUAL

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Code Complaint Type Section Violation description and Corrections required

Installation Manual. For. Alumavator / Platinum Boathouse Lifts

OWNER S MANUAL Spa & Jetted Bathtub Pump

Transcription:

HIGHLIFE COLLECTION Congratulations on your decision to enjoy the finest spa available... Welcome to the growing family of HOT SPRING spa owners. Pre-Delivery Instructions Please take the time to read this booklet carefully, as it will provide you with the information you will need to ensure the safe, secure, and timely installation of your new spa. The following sections are guidelines on how to prepare for delivery and set-up of your new spa. Specifically covered are site selection, delivery access, ground preparation, and electrical requirements. Remember to carefully review the Owner s Manual that accompanies your spa, and to register the spa's warranty within 10 days of delivery. These items, along with other valuable information, will be found in the Owner s Package which has been placed in the equipment compartment of your spa, where you will also find its serial number. Watkins Manufacturing Corporation reserves the right to change features, specifications and design without notification and without incurring any obligation. DATE PURCHASED: Register your warranty DATE INSTALLED: using the QR code below: DEALER: ADDRESS: TELEPHONE: In most cities and counties, permits will be required for the installation of electrical circuits or the construction of eterior surfaces (decks and gazebos). In addition, some communities have adopted residential barrier codes which may require fencing and/or self-closing gates on the property to prevent unsupervised access to a pool (or spa) by children under 5 years of age. Your HOT SPRING spa is equipped with a locking cover that meets the ASTM F1346-91 Standard for Safety Covers and as a result, is usually eempt from most barrier requirements. As a general practice, your local Building Department will inform you of any applicable barrier requirements at the time a permit is obtained for the installation of an electrical circuit. Your Hot Spring dealer can provide information on which permits may be required. Hot Spring Spa Pre-Delivery Page Instructions

Site Selection and Preparation IMPORTANT: Site selection and preparation are your responsibility. Carefully read these instructions and consult your authorized HOT SPRING dealer if you have any questions. You probably have a spot picked out for your new spa, whether it s indoors or outdoors, on a patio or on a deck. Just make sure you check the following: Always put your spa on a structurally sound, level surface. A filled spa can weigh a great deal. Make certain that the location you choose can support the weight of your filled spa. Don t forget to level your spa before filling it. (See Spa Leveling Instructions included in Owner s Manual.) Locate your equipment compartment, which houses all of the electrical components, in a place where water will drain away from it. Allowing water into the equipment compartment can damage the electronics, or may result in tripping your house s circuit breaker. Leave yourself easy access to the circuit breakers in the subpanel (230 volt models), or to the interrupter switch on the end of the power cord (115 volt models). Never let water get into the subpanel (230 volt models), into the interrupter switch (115 volt models), or into the electrical outlet that your spa is plugged into. Your 115 volt HOT SPRING spa will come with a protective bo designed to keep out rain and water from sprinkler systems. Your 230 volt spa s subpanel is raintight when installed correctly with the door closed. Leave access to the equipment compartment for periodic spa care and maintenance. OUTDOOR AND PATIO INSTALLATION No matter where you install your new spa, it s important that you have a solid foundation to support it. Structural damage to the spa resulting from incorrect installation or placement on an inadequate foundation is not covered under the spa s limited warranty. If you install the spa outdoors, a reinforced concrete pad at least four inches thick is required for the Grandee spa, and recommended for the Envoy, Vanguard, Aria, Sovereign, Prodigy and Jetsetter spas. The reinforcing rod or mesh in the pad should be attached to a bond wire (see your Owner s Manual). All Hot Spring spas may be installed onto a deck, provided that the load capacity of the deck is greater than the dead weight of the spa (see Deck Installation). If you place the spa on the ground, even temporarily, place stepping stones under the leveling areas (see Spa Leveling Instructions in your Owner s Manual). The stones should be at least two inches thick and twelve inches square. Even with stones in place, the spa will inevitably settle and become unlevel. Plus, a spa surrounded by dirt or grass will soon be filled with dirt or grass from users feet; therefore, it is important to get it onto a solid foundation as soon as possible. DECK INSTALLATION To be certain your deck can support your spa, you must know the deck s maimum load capacity. Consult a qualified building contractor or structural engineer before you place the spa on an elevated deck or indoors. To find the weight of your spa, its contents and occupants, refer to the Spa Specification chart. This weight per square foot must not eceed the structure s rated capacity, or serious structural damage could result. INDOOR INSTALLATION Be aware of some special requirements if you place your spa indoors. Water will accumulate around the spa, so flooring materials must provide a good grip when wet. Proper drainage is essential to prevent a build-up of water around the spa. When building a new room for the spa, it is recommended that a floor drain be installed. The humidity will naturally increase with the spa installed. Water may get into woodwork and produce dryrot, mildew, or other problems. Check for airborne moisture s effects on eposed wood, paper, etc. in the room. To minimize these effects, it is best to provide plenty of ventilation to the spa area. An architect can help to determine if more ventilation must be installed. Your HOT SPRING dealer can help you with local information such as zoning regulations and building codes. Pre-Delivery Instructions Page 2

DELIVERY ACCESS First, locate the dimensions of your spa on the following chart. The dimensions shown are the measurements of the spa in the vertical position, laid on its side. Net, contact your dealer to find the height and width added by the delivery cart which the dealer will use to deliver your new spa. Use the height of the cart plus the dimension shown as H to determine the vertical clearance required to pass the spa and cart. Use the width of the cart, or dimension W, whichever is greater, to determine the maimum width of clearance necessary. NOTE: It may be necessary to allow for additional over-head clearance if the spa will be rolled up or down an incline or moved up or down a short flight of stairs. Use the information below to determine the requirements for access to your desired location. Model Width W Length L Height H GRANDEE (GG) 38" 8'4" 7'7" ENVOY (KK) 38" 7'9" 7'7" VANGUARD (VV) 36" 7'3" 7'3" ARIA (AR) 36" 7'3" 7'3" SOVEREIGN (II) 33" 7'9" 6'8" PRODIGY (H) 33" 7'0" 6'6" JETSETTER (JJ) 29" 7'0" 5'5" How is your width clearance? BACK YARD Check all gates Protruding electric meters Gas meters A/C units Do you have sufficient overhead clearance? Check low roof eaves, overhanging branches, rain gutters Is the path clear? HOUSE Move away branches, dog houses, firewood, etc. If there is a 90 turn, can we clear it? (The spa will not bend) No more than 6 consecutive stairs without a landing STREET Page 3 Pre-Delivery Instructions

It may be necessary to remove a gate, part of a fence, or other movable obstructions in order to roll the spa to its installation site. About ten percent of the time, a crane is the only way to install the spa by lifting it to its final destination. If the spa has to be taken off of the cart to go over a wall (either because the entry area is too narrow, the eaves are too low, the corner is too tight, or the stairway is too steep), a crane will be required. Don t be alarmed! The crane has a truck-mounted boom which can fit right in your driveway. It is run by a licensed and insured operator. For a charge, the crane operator will lift your spa over walls, buildings, or any other obstruction and place it as close to the installation site as possible. The HOT SPRING spa delivery personnel will supervise the crane delivery and complete the spa installation. NOTE: If your spa delivery requires the use of a crane, you may be required to pay for its services at the completion of the delivery. GROUND PREPARATION Your Hot Spring spa has been engineered to perform on all kinds of common yard surfaces. While a concrete slab is best for long-term use*, other foundations are acceptable so long as a level base is prepared prior to delivery. Three foundation base pictures, shown at right, represent eamples of alternatives to a concrete slab for spas installed without gazebos or other accessories. *NOTE: A reinforced concrete pad at least four inches thick or a deck that is able to withstand more than 125 per square foot is required for the GRANDEE spa, and recommended for the ENVOY, VANGUARD, ARIA, SOVEREIGN, PRODIGY and JETSETTER spas. INSTALLATION NOTES: If stepping stones or railroad ties are selected for the spa foundation, they should be placed at the designated leveling areas of your spa to maintain even distribution of the spa weight. It is important to note that soft surfaces, even when stepping stones are used to distribute the weight of the spa as evenly as possible, will still have a tendency to settle unevenly, resulting in an unlevel spa. Remember, placing the spa on grass or dirt may increase the amount of debris which is inadvertently brought into the spa water on the user s feet. If you are purchasing a deck package or a gazebo with your spa, a solid foundation becomes mandatory. Placing them on any surface other than a single level pad could create problems with their installation. Pictured at right are a few of the recommended surfaces. As a homeowner, it is your responsibility to provide a suitable, level foundation for your spa. Keep in mind that most delivery crews are not equipped to level and prepare spa sites. If you are interested in having a concrete slab, brick surface, or wood deck installed, your HOT SPRING dealer should be able to suggest a qualified, licensed contractor. NOTE: In order for the spa to operate properly and the internal plumbing to drain completely, you must ensure that the spa is leveled after it has been installed. The diagrams on the following pages indicate the recommended shimming points on your spa s base support system. Your HOT SPRING spa delivery crew can help you perform the procedure. FOUNDATIONS FOR SPAS ONLY (No accessories such as cover or gazebo) PEA GRAVEL OR CRUSHED ROCK RAILROAD TIES PRE-CAST STEPPING STONES FOUNDATIONS FOR SPAS WITH ACCESSORIES CONCRETE PADS BRICK SURFACES WOOD DECKING Pre-Delivery Instructions Page 4

GRANDEE GRANDEE (MODEL GG) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 84.5" (214.6 cm) 34.5" (87.6 cm) 34.5" (87.6 cm) 38" (96.5 cm) 38" (96.5 cm) MAIN DRAIN 1.75 (4.4 cm) ELECTRICAL CUTOUT SECONDARY DRAIN 15.5" (39.4 cm) cm) 47.5" (120.7 cm) 71 "" (180.3 cm) 3.5" (8.9 cm) 3.5" (8.9 cm) (Bottom view) UPSIDE DOWN VIEW OF SPA 24.75" (62.9 cm) 19.5 (49.5 cm) 19.5 (49.5 cm) 24" (61 cm) 24.75" (62.9 cm) 19.5 (49.5 cm) 19.5 (49.5 cm) 24" (61 cm) 91" (231 cm) 91" (231 cm) 53.5" (135.9 cm) 43" (109.2 cm) 53.5" (135.9 cm) 43" (109.2 cm) 100" (254 cm) 100" (254 cm) DOOR SIDE NOTE: Watkins Manufacturing Corporation requires that the GRANDEE be installed on a minimum 4 (10 cm) thick reinforced concrete pad or a deck that is able to withstand more than 115 per square foot (555 /m²). WARNING: The GRANDEE must not be shimmed in any manner. Pre-Delivery Instructions Page 5 Pre-Delivery Instructions

ENVOY (MODEL KK) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 77.75" (197.5 cm) 34 " (86.4 cm) 38" (96.5 cm) MAIN DRAIN 1.75 (4.4 cm) ELECTRICAL CUTOUT SECONDARY DRAIN 72 1/2" (184.2 cm) 44" (111.8 cm) 14 1/2" (36.8 cm) 3.5 " (8.9 cm) 93" (236.2 cm) 44.5" (113 cm) 44.5" (113 cm) 18" (45.7 cm) 18" (45.7 cm) (Bottom view) UPSIDE DOWN VIEW OF SPA 26.5 " (67.3 cm) 22" (55.9 cm) 17" (43.2 cm) 22.25" (56.5 cm) 91" (231 1cm) DOOR SIDE 15 leveling points (place shims at illustrated locations). Pre-Delivery Instructions Page 6

VANGUARD (Model VV) & ARIA (Model AR) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 71.75" (182.2 cm) 32 " (81 cm) 36" (91 cm) MAIN DRAIN 1.75 (4.4 cm) ELECTRICAL CUTOUT SECONDARY DRAIN 62 " (157.5 cm) 41" (104.1 cm) 21.5" (54.6 cm) 3.5 " (8.9 cm) (Bottom view) UPSIDE DOWN VIEW OF SPA 26.75" (67.9 cm) 20" (50.8 cm) 20 " (50.8 cm) 21 " (53.3 cm) 87" (221 cm) 18" (46 cm) 41.5" (105 cm) 41.5" (105 cm) 87" (221 cm) 18" (46 cm) DOOR SIDE 15 leveling points (place shims at illustrated locations). Page 7 Pre-Delivery Instructions

SOVEREIGN (Model II) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 65.25" (165.7 cm) 29 " (73.6 cm) 33" (83.8 cm) MAIN DRAIN 1.75 (4.4 cm) ELECTRICAL CUTOUT 60" (152.4 cm) 14.5" (36.8 cm) 37.5" (95.3 cm) 3.5" (8.9 cm) SECONDARY DRAIN 18" (45.7 cm) 38" (96.5 cm) 38" (96.5 cm) 18" (45.7 cm) (Bottom view) 23.75" (60.3 cm) 20" (50.8 cm) 20" (50.8 cm) 25" (63.5 cm) UPSIDE DOWN VIEW OF SPA 93" (236 cm) Pre-Delivery Instructions Page 8 80" (203 cm) DOOR SIDE 15 leveling points(place shims at illustrated locations).

PRODIGY (Model H) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 62.75" (159.4 cm) 29 " (73.6 cm) 33" (83.8 cm) MAIN DRAIN 1.75 (4.4 cm) ELECTRICAL CUTOUT 63" (160.0 cm) 14" (35.6 cm) 36" (91.4 cm) 3.5" (8.9 cm) SECONDARY DRAIN 37" (94 cm) 37" (94 cm) 18" (45.7 cm) 18" (45.7 cm) (Bottom view) 21" (53.3 cm) 20" (50.8 cm) 20" (50.8 cm) 19.5" (49.6 cm) UPSIDE DOWN VIEW OF SPA 84" (213.4 cm) 78" (198 cm) DOOR SIDE 15 leveling points(place shims at illustrated locations). Page 9 Pre-Delivery Instructions

JJE JETSETTER (Model JJ) Dimensions NOTE: All dimensions are approimate; measure your spa before making critical design or pathway decisions. (Front view) DOOR 69.25" (175.9 cm) 3" (7.6 cm) 29" (73.7 cm) 62" (157.5 cm) 66" (167.6 cm) 84" (213 cm) 80" (203 cm) 15.5" (39.4 cm) 25 " (63.5 cm) SECONDARY DRAIN MAIN DRAIN 1.75 (4.4 cm) ELECTRICAL CUTOUT 39" (99.1 cm) (Bottom view) 15.5" (39.4 cm) 15.5" (39.4 cm) 15.5" (39.4 cm) UPSIDE DOWN VIEW OF SPA 61" (155 cm) 65" (165 cm) 21" (53.3 cm) 19.25" (48.9 cm) 19.25" (48.9 cm) 21.25" (54 cm) DOOR SIDE 15 leveling points (place shims at illustrated locations). Pre-Delivery Instructions Page 10

ELECTRICAL REQUIREMENTS To ensure you will have an opportunity to use your spa soon after delivery, it is very important that the required electrical service has been installed. Unless otherwise stipulated by your dealer, THIS IS YOUR RESPONSIBILITY. IMPORTANT: All electrical circuits must be installed by a qualified, licensed electrician. HOT SPRING spas are manufactured in two different electrical versions. The GRANDEE, ENVOY, VANGUARD, ARIA and SOVEREIGN models are available with a 230 volt continuous heating system. These spas cannot be converted to 115 volt operation. The remaining spa model, the PRODIGY & JETSETTER are available as 115/230 volt convertible heating systems. This models comes standard from the factory with 115 volt heating systems; however, with the addition of a subpanel and a control bo wiring change, they can be converted to 230 volt operation. See the following sections for the electrical requirements for 115 volt operation, 230 volt operation and 230 volt converted operation. 115 VOLT OPERATION REQUIREMENTS The 115 volt spa requires a dedicated 20 amp, 115 volt circuit. This circuit must be properly wired; that is, it must have a 20 amp GFCI breaker in the main electrical service panel, and #12 AWG wire (including ground wire) and the correct polarity throughout the circuit. WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maimum voltage drop of 3% be used when calculating the larger wire size. NOTE: The term dedicated means that only the spa operates on the circuit. Each 115 volt model comes equipped with approimately 15 feet of usable power cord. (This is the maimum length allowed by Underwriters Laboratory.) When the spa is installed, the power cord will come out of the bottom of the equipment compartment. In addition to the dedicated 20 amp, 115 volt GFCI protected circuit, your spa requires a 20 amp single receptacle. This receptacle, which contains an outdoor-rated, weather-resistant receptacle cover plate, will be provided to you. The single receptacle and cover plate should be installed by your electrician prior to the delivery of your spa. For your safety, when your electrician is installing the electrical outlet, it should be no closer than five (5) feet and no farther than ten (10) feet from the spa. (Reference National Electric Code 680-6a(1) and 680-41a.) WARNINGS: Do not connect your spa to an etension cord! The 115 volt GFCI switch and the receptacle must be protected from weather and landscape sprinklers they should never get wet. NOTE: If you require the services of a licensed electrician, your HOT SPRING Dealer should be able to suggest one for you. Your HOT SPRING spa has been carefully engineered to provide maimum safety against electric shock. Remember, connecting the spa to an improperly wired circuit will negate many of its safety features. Page 11 Pre-Delivery Instructions

230 VOLT OPERATION REQUIREMENTS All models require a 50 amp, single phase, 230 volt circuit breaker in the main electrical service panel. All 230 volt Hot Spring spas must be wired in accordance with applicable local and national electrical codes, all electrical work must be done by a licensed electrician. NOTE: Watkins Manufacturing Corporation RE QUIRES THE USE OF A SUBPANEL TO SUPPLY POWER AND PROTECT THE SPA. On the GRANDEE, ENVOY, VANGUARD, ARIA and SOVEREIGN models, the subpanel containing GFCI breakers is included with the spa. On the 230 volt PRODIGY & JETSETTER model, the subpanel containing GFCI breakers must be purchased separately and can be purchased from your HOT SPRING dealer. A licensed electrician should install a four-wire electrical service (two line voltages, one neutral, one ground) from the main electrical service panel to the subpanel, and from the sub-panel to the spa per the appropriate wiring diagram as illustrated below. The grounding conductor must be at least #10 AWG. Your electrician should mount the subpanel in the vicinity of the spa but it should not be closer than five (5) feet from the spa water edge (NEC 680-38 to 41-A-3). INSTALLATION NOTE: After the spa has been installed by the dealer s delivery crew, your electrician can connect the conduit from the subpanel to the spa s IQ 2020 Control Bo and then complete the wiring connections in the control bo. IMPORTANT NOTE: Three different wiring diagrams are shown: one for GRANDEE, ENVOY, VANGUARD & ARIA models. One for the SOVEREIGN model, and one for the PRODIGY & JETSETTER models. Always follow the wiring diagram for your specific model. NOTE: Complete step-by-step Installation and Wiring Instructions for all 230 volt Hot Spring models are included in the Owner s Manual and with each sub-panel, which can be obtained from your dealer. WARNING: Removing or bypassing the GFCI breakers in the subpanel at any time will result in an unsafe spa and will void the warranty. WIRE SPECIFICATION NOTE: Long electrical runs may require a larger gauge feed wire than stated. We recommend that a maimum voltage drop of 3% be used when calculating the larger wire size. Refer to the Wiring Diagrams to the right for the electrical requirements of the 230 volt models. When connecting the supply conduit to the bottom of the IQ 2020 bo, use a 3/4 liquid-tight fle conduit fitting. GRANDEE (Model GG), ENVOY (Model KK), VANGUARD (Model VV) & ARIA (Model AR) 230 volt permanently connected models WARNING! The eact physical location of the terminals on the GFCI breaker will vary between manufacturers. Connecting the hot wire to the neutral terminal will cause irreversible damage to the control bo. 230V, 50 Amp, 2-POLE, CIRCUIT BREAKER (NON GFCI) # 8 AWG WHITE, NEUTRAL MAIN SERVICE ELECTRICAL PANEL # 10 AWG GREEN, GROUND** L1 #12 AWG BLUE # 8 AWG BLUE, L1 # 8 AWG RED, L2 LESS THAN 100 FT. GROUND #10 AWG GREEN *SUBPANEL WITH GFCI BREAKERS L2 #12 AWG RED L1 #10 AWG BLUE L2 #10 AWG RED N #10 AWG WHITE Minimum 5 FEET The Subpanel must be within sight of the spa Do no eceed 50 FEET See owner s manual or control bo schematic for electrical connection details. NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 30 amp breaker. GRD *PROVIDED WITH SPA. NOTE: ALL WIRING SHOULD BE COPPER. Pre-Delivery Instructions Page 12

SOVEREIGN (Model II) 230 volt permanently connected models WARNING! The eact physical location of the terminals on the GFCI breaker will vary between manufacturers. Connecting the hot wire to the neutral terminal will cause irreversible damage to the control bo. HEATER GROUND 230V, 50 Amp, 2 POLE, CIRCUIT BREAKER (NON GFCI) #8 AWG WHITE, NEUTRAL #10 AWG GREEN, GROUND #8 AWG BLUE, L1 50A #8 AWG RED, L2 MAIN SERVICE ELECTRICAL PANEL N L1 L2 L2 #12 AWG RED L1 #12 AWG BLUE GRD 20A N #12 AWG WHITE L2 #10 AWG RED 30A L1 #10 AWG BLUE GROUND #10 AWG GREEN 1 2 3 4 5 TB1 See owner s manual or control bo schematic for electrical connection details. GRD LESS THAN 100 FT. CONTROL BOX NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 20 amp breaker. *PROVIDED WITH SPA. NOTE: ALL WIRING SHOULD BE COPPER. PRODIGY (Model H) & JETSETTER (Model JJ) 230 volt converted models WARNING! The eact physical location of the terminals on the GFCI breaker will vary between manufacturers. Connecting the hot wire to the neutral terminal will cause irreversible damage to the control bo. HEATER GROUND 230V, 50 Amp, 2 POLE, CIRCUIT BREAKER (NON GFCI) #8 AWG WHITE, NEUTRAL #10 AWG GREEN, GROUND #8 AWG BLUE, L1 50A #8 AWG RED, L2 MAIN SERVICE ELECTRICAL PANEL LESS THAN 100 FT. N L1 L2 L1 #12 AWG BLUE GRD 20A N #12 AWG WHITE L2 #10 AWG RED 30A L1 #10 AWG BLUE GROUND #10 AWG GREEN 1 2 3 4 5 TB1 See owner s manual or control bo schematic for electrical conversion and connection GRD details. CONTROL BOX NOTE: The wire connections to GFCI breakers are for reference only. Always ensure the white neutral wire is connected to the load neutral of the 20 amp breaker. *AVAILABLE FROM DEALER. NOTE: ALL WIRING SHOULD BE COPPER. Page 13 Pre-Delivery Instructions

WIRE INSTALLATION FOR CONTROL BOX TERMINAL BLOCK (Layout of Spa s Terminal Blocks may vary) Insert screwdriver to engage cage 3 Push top of screwdriver away from wire Terminal Block Wire Installation Steps 1/2 4 Strip wire insulation back ½ Install Stripped end of wire into Terminal Block Refer to spa s wiring diagram on back of Control Bo Cover for proper wiring and jumper configuration! Entire stripped end of wire must be inside Terminal Block 5 3 After step 6, pull on wire to ensure proper installation Remove screwdriver 6 SERVICES AVAILABLE FROM YOUR HOT SPRING SPA DEALER Service Pre-Delivery site inspection Deliver spa to installation site Unwrap spa and haul away packaging material Set up & level spa Fill the spa with water Connect the spa to its power source (115 volt models) Eplain and test the spa s operation Cost Jet system Moto-Massage DX jet Comfort Control system Set temperature control Eplain the safety features Control panel functions GFCI Heater high limit Heater thermal cut-off General spa operation & maintenance orientation Water quality and maintenance orientation Adjust the water s Total Alkalinity, and ph Sanitize the water Inspect the spa cover, place on spa Review winterizing instructions Review Owner s Manual & Warranty Card Follow-up call In-store spa water analysis In-store spa water analysis TOTAL COST Pre-Delivery Instructions Page 14

ADDITIONAL PRODUCTS AVAILABLE FROM YOUR HOT SPRING SPA DEALER ACE Salt Water Sanitizing System EverFresh water care system featuring the FreshWater III high output ozone, MPS, and FreshWaterAg+ Silver Ion Cartridge Clean Screen Pre-filter Vanishing Act Calcium Remover FRESHWATER Bottled Water Care Products FRESHWATER Test Strips FRESHWATER Instant Filter Cleaner and Filter Cleaner FRESHWATER Spa Shine FRESHWATER CoverShield Retractable cover systems including the CoverCradle, CoverCradle II, UpRite and Lift n Glide systems. Vinyl covers Spa steps Cover Cradle - 24 Clearance required Cover Cradle II - 24 Clearance required UpRite - 7 Clearance required Lift n Glide - 14 Clearance required Replacement filter cartridges Pillows CONTRACTOR SUGGESTIONS Electrician Name: Telephone: Name: Telephone: Masonry Name: Telephone: Name: Telephone: General Name: Telephone: Name: Telephone: Page 15 Pre-Delivery Instructions

Spa Specifications Footprint dimensions Height Effective filter area Heater (Watts) Water capacity Dry weight Filled weight* Dead weight* Electrical requirements GRANDEE (Model GG) Seats 7 Adults 7' 7" 8' 4" 2.31m 2.54m 38" 97cm **325 Square Feet 4,000 450 gallons 1,700 liters 1060 480 6,040 2,740 115 per square foot 230 volt, 50 single phase GFCI protected circuit ENVOY (Model KK) Seats 5 Adults 7' 9" 7' 7" 2.36m 2.31m 38" 97cm **325 Square Feet 4,000 390 gallons 1,475 liters 950 430 5,080 2,305 110 per square foot 230 volt, 50 single phase GFCI protected circuit VANGUARD (Model VV) Seats 6 Adults 7' 3" Sq. 2.20m Sq. 36" 91cm **325 Square Feet 4,000 335 gallons 1,275 liters 820 370 4,665 2,125 120 per square foot 230 volt, 50 single phase GFCI protected circuit ARIA (Model AR) Seats 5 Adults 7' 3" Sq. 2.20m Sq. 36" 91cm **325 Square Feet 4,000 325 gallons 1,225 liters 820 370 4,405 1,995 115 per square foot 230 volt, 50 single phase GFCI protected circuit SOVEREIGN (Model II) Seats 6 Adults 6' 8" 7' 9" 2.03m 2.36m 33" 84cm 120 Square Feet 6,000 315 gallons 1,200 liters 745 340 4,425 2,020 110 per square foot 230 volt, 50 single phase GFCI protected circuit PRODIGY (Model H) Seats 5 Adults 6' 6" 7' 0" 2.03m 2.36m 33" 84cm 90 Square Feet 1,500 or 6,000 290 gallons 1,100 liters 645 295 3,940 1,795 115 per square foot 115 volt, 20 amp Dedicated GFCI protected circuit 230 volt, 50 amp single phase GFCI protected circuit JETSETTER (Model JJ) Seats 3 Adults 5'5" 7'0" 2.26m 2.26m 29" 74cm 90 Square Feet 1,500 or 6,000 200 gallons 750 liters 475 215 2,670 1,205 90 per square foot 115 volt, 20 amp Dedicated GFCI protected circuit 230 volt, 50 amp single phase GFCI protected circuit CAUTION: Watkins Manufacturing Corporation suggests a structural engineer or contractor be consulted before the spa is placed on an elevated deck. * NOTE: The Filled weight and Dead weight of the spa includes the weight of the occupants (assuming an average occupant weight of 175 lbs). **Effective filter area is based on 6.5 square feet actual area per filter with 10 times effectivity rating. Pre-Delivery Instructions Page 16

WATKINS MANUFACTURING CORPORATION 1280 Park Center Drive Vista, California 92081 (800) 999-4688 etension 8432 2016 Watkins Manufacturing Corporation. Hot Spring, Built for a lifetime of relaation, Moto-Massage, Highlife, Grandee, Envoy, Vanguard, Aria, Sovereign, Prodigy, Jetsetter, AutoFresh, Comfort Control, CoverCradle, GlideRite, Lift nglide, UpRite, IQ 2020, CoverShield, ACE, EverFresh, FreshWater, Vanishing Act and The Home Relaation Specialists are trademarks of Watkins Manufacturing Corporation. 62904.17 A (11/16) Page