ELEKTROMATEN ST Sliding-door-drive

Similar documents
ELEKTROMATEN SI Rapid Safedrive. Emergency manual operation. Door controls. Limit switches. Mounting. Special versions. Series SG63F SI 17.

ELEKTROMATEN SE Sectional-door-drive. Emergency manual operation. Special versions. Limit switches. Door controls. Mounting

ELEKTROMATEN SI FI Safedrive with built-on frequency inverter

Opener with external control unit Opener with integrated control unit (Illustration: Deadman mode)

Mechanical Operating Instructions

Door Control Panel TS 960. instructions. (Design and functions subject to change) /

Operating Instructions for Roll-Up Door Operators / MDF

Rolling door drives and controls robust and safe

Installation instructions

Electrical operating instructions

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Installation Instructions

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

Lexium integrated drives

Installation instructions

Electrical operating instructions

Lexium integrated drives

Mechanical operating instructions

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Electrical operating instructions

HITACHI ELECTRIC CHAIN HOISTS

HIGH SPEED SLIDING GATE OPENER

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

Slide gate openers MOVEMENT BRINGS MORE

ENGINE WINCHES from 300 to 5000 kg - TS and TD Series

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

REVISED ATM72 Auto Transfer Module

AE 9... AE 40 Contactors NE... Contactor Relays

ZAP Controls. ZAP Controls. Series 3 Commercial Operator Catalog. Series 3 Commercial Operator Catalog. ZAP Series 3 Simply Logical.

Transmission systems: Multiple components that have the same type of movement (rotational, linear, etc)

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

Installation instructions

Technical Data Sheets

! C A U T I O N! Damages on the machine possible.

Modifications List. Control and Panel Modifications. Call: Effective Nov. 1, 2012

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

DKG-114 MANUAL AND REMOTE START UNIT

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011

Interroll. Product Description. Material Versions. Technical Data. Options. Order Information. Accessories. Standard Asynchronous

Electrical Operating Instructions

COOKSON OWNER'S MANUAL

mono-mix Contents Complete Equipment with Scope of Supplies 3 Accessories 4-5 Spare Parts

SMS PRODUCT CATALOGUE

1. Basic parameters... 1

Assembly and Operating Instructions

LIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER

BETA Switching Switches and Light Indicators

Commercial Garage Door & Gate Operators

Electrical Operating Instructions

3RT14 Contactors with 3 Main Contacts

TAE pole Contactors

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Technical Data Sheets

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

PSM72H Push-Button Start Module

DEEP SEA ELECTRONICS PLC

Locking Assemblies & Locking Elements

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

Interroll. Material Versions. Product Description. Technical Data. Options. Accessories. Order Information. Standard Asynchronous

Max. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max.

Electrical operating instructions

The electro-mechanical power steering with dual pinion

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

C-SERIES S-SERIES. Metric Machine Screw Jacks EMA LINEAR ACTUATORS

WEEK DELIVERY. High-Speed Doors. For optimised material flow and improved efficiency. Made in Germany

DEVICE STATE/BYPASSED FAILURE OVERLOAD

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Product Information ECN 425 EQN 437. Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications

Electrical operating instructions

HP High-Performance Gear Units with <2' Adjustable Backlash

INTERROLL DRUM MOTOR 80i

Power Electronics. Motor brake relay GA 9031 ministop

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

zelsius Installation and operating manual All that counts EnergyMetering

DC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A

TITANO 400V SLIDING GATE OPENER

DC motors. G-motion. CTi Automation - Phone: Fax: Web:

Gate & Door Controller with LCD and Intelligent Technology

Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar

Rotary Indexing Tables are used in rotary special purpose machines and other types of machines to mount fixtures, work pieces for precision indexing.

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

WELDING POSITIONER S OPERATION MANUAL CWP40

High performances 5 Axis Machining Center Performance Technology Power Accuracy

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Compact Units. For fluid grease, NLGI grades 000, 00 Group MKF 0.1 or 0.2 l/min EN

Electronic Circuit Breaker ESS20

INSTRUCTION & INSTALLATION

MODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL. OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318

Low-Voltage Motors N-compact Standardline Operation on supply system

Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

EM DC Multi-Function DC Energy Meter

Transcription:

ST Sliding-door-drive for sliding doors ST 9.5 ST 80. Output torque: 90-800 Nm Output speed: 5 - rpm Control panels for ST WS 905 / TS 00.0.0 Subject to alterations. (_Db).000

ST Sliding-door-drive For driving: Sliding-doors Series SG50R ST 9.5 ST 9. Series ST 6.5 ST 0. Series SG5R ST 60.5 ST 80. ST are special drives for sliding-doors designed for industrial use. ST comprises of: Worm gear with integrated friction clutch, interchangeable output-shaft, magnetic brake (optional), emergency manual operation (optional), integrated limit switch (optional), mounting accessories and electrical motor. Output side: The interchangeable output-shaft allows easy modification from left- to right-hand use. Friction clutch: The integrated friction clutch guarantees impact-damped, low-wear operation. Magnetic brake (optional): Ensures precise positioning of the door limit position, slightly heating ensures trouble-free operation at low outside temperatures. Integrated limit switch (optional): No need of separate limit switches SG50R Approvals and certificates Type test according to: DIN EN 5 DIN EN 605- DIN EN 605--0 SG5R Emergency manual operation (optional) E.g.: for top-hung sliding doors Hand crank NHK Hand chain operator KNH Limit switch integrated (optional) Mechanical limit NES operating, emergency- and auxiliary limit switches Digital limit DES Absolute encoder, after a power failure, re-adjustment is not required Separate limit switch (optional) Roller-arm limit switch Inductive limit switch Mounting Foot angle (standard fitting) Mounting base Special versions Increase of movements per hour Other voltages and frequencies ST-TRK: Sliding-door with magnetic brake ST-SI: Sliding-door with integrated safety brake, e.g. for sliding doors operating on an incline Door controls Simple connection to the limit switch by means of non-interchangeable plug connections allowing simple exchange with other GfA control panels Control voltage: V Frequency: 50 / 60 Hz Supply voltage: N~0V, ~0V, N~00V, ~00V Details of all GfA door controls for sliding doors can be found from page.0. Subject to alterations. (_Cf).0

. Technical data Series ST 9.5 SG50R ST 9. SG50R ST 6.5 ST 6. ST 0.5 Output torque Output speed Max. door weigth Door speed Output shaft / hollow shaft (Ø) Permitted OPEN / CLOSE output speed in frequency-inverter operating mode Motor power Supply voltage Operating frequency Operating current Max. movements per hour 5 Supply side wiring fusing (delayed-action) Limit switch range 6 Weight Spare parts: Catalogue page Part no. installation drawing (dxf, dwg) Part no. Nm rpm N cm/ sec mm rpm kw V - Hz Hz A kg 90 90 60 60 00 5 5 5 9.000 9.000 6.000 6.000 0.000 7 9 5 5 0 0 0 6 / 6 / 6 / 6 / 6 / 6 0,0 0,7 0,55 0,0 0,75 ~0 / 00V ~0 / 00V ~0 / 00V ~0 / 00V ~0 / 00V 50 50 50 50 50,6 /,5, /,, /,8, /,8 5, /,0 0 0 6 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 0 / 0 0 / 0 0 / 0 0 /0 0 /0 6 6 5 6 9.09 9.09 9.09 9.09 9.09 50000976 50000976 5000099 5000099 5000099 0007 00097 0007 00099 0007 Series ST 0. ST 60.5 SG5R ST 60. SG5R ST 80.5 SG5R ST 80. SG5R Output torque Output speed Max. door weigth Door speed Output shaft / hollow shaft (Ø) Permitted OPEN / CLOSE output speed in frequency-inverter operating mode Motor power Supply voltage Operating frequency Operating current Max. movements per hour 5 Supply side wiring fusing (delayed-action) Limit switch range 6 Weight Spare parts: Catalogue page Part no. installation drawing (dxf, dwg) Part no. Nm rpm N cm/ sec mm rpm kw V - Hz Hz A kg 00 600 600 800 800 5 5 0.000 60.000 60.000 80.000 80.000 9 9 9 0 50 50 50 50 / 6 / 6 / 6 / 6 / 0,85,0,50,0,00 ~0 / 00V ~0 / 00V ~0 / 00V ~0 / 00V ~0 / 00V 50 50 50 50 50, /,6 7, /, 6,7 /,9 7,0 /, 8, /,7 6 6 6 0 0 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 0 / 0 0 / 60 0 /60 0 / 60 0 / 60 6 50 50 5 5 9.09 -- -- -- -- 5000099 5000 5000 5000 5000 00099 0000 00059 0007 00095 Generally applies: Protection class IP5, permissible temperature range -0 C...+0 C (+60 C), from -0 C in combination with a permanently used magnetic brake, operating sound pressure level SPL 70 db(a) See.6 Door speed when operated with standard chain wheel, see 5. We recommend the selection of a special (enquire) for use with frequency inverter, OPEN drive speed at 87 Hz, see.6 and.7 The operating current in door drives can reach up to x the rated current for limited periods, see.7 and.8 5 When using a temperature range of +0 C...+60 C use half of maximum movements per hour, see also. 6 Maximum possible revolutions of output-shaft with integrated limit switch, see.9.0 Subject to alterations. (_Cf)

. Notes. European directive In accordance with the product standard EN - Doors- and EN 5 Safety in use of power operated doors-requirements.. Movements per hour The indicated movements per hour (See item -. Technical data) may not be exeeded.. Magnetic brake The optional magnetic brake locks the output-shaft when the motor is switched off. The magnetic brake ensures precise positioning of the door in the limit position and avoids overrunning the limit position of the door. Slight heating ensures trouble-free operation at low outside temperatures.. Gear self-braking / Brake Drives without an electric brake have a self-sustaining worm gear and stop automatically. On drives with an electric brake, stopping is achieved by the external brake. Brake inspection must always be carried out by qualified service engineers..5 Manual operation In the event of power failure, the door can be opened by hand after releasing the friction clutch. Emergency manual operation by crank handle or chain is also available as an option (e.g. for top-hung sliding doors)..6 Output torque / Door weight / Friction clutch.7 Motor overload protection Motor overload protection must be able to withstand x the operating motor current because the starting current of the drive unit can reach these levels for short periods..8 Use with external frequency inverter For external frequency inverters applies: A higher than recommended drive speed puts extra load onto the gear. This extra load must be taken into account when sizing a drive by reducing the available output torque.. The admissible drive speeds may not be exceeded (See item -. Technical data). The operating forces must comply with EN 5, and the corresponding EMC directives must likewise be observed. If selecting a frequency inverter, note that the starting current of the drive unit can reach x of the operating motor current..9 Integrated limit switch The door construction should be designed to prevent the disengaging of drive elements (sprocket, chain, rack etc.). The stopping accuracy of the ST with magnetic brake and a limit switch range of E0 is approximately +/- 5mm (for E0, approx. +/- 5mm). The door construction must be designed to compensate onsite these differences (e.g. height- of the rubber profile of the safety edge). For higher requirements regarding stopping accuracy, we recommend the use of separate limit switches (roller-arm limit switches, inductive limit switches, etc.). The integrated slipping clutch guarantees impact-damped, lowwear operation. The admissible output torque is pre-adjusted. If the clutch is subject to higher forces than the admissible (e.g. the possibility of attempted forced entry) additional improvements of the door design may be required to prevent undesired opening of the door. The weights indicated apply to horizontal, rail-mounted sliding doors.. Dimensions. ST 9.5 ST 9. SG50R 7 5 8 Worm gear with friction clutch Motor Terminal box / optional: integrated limit switch Magnetic brake 5 Hand wheel for slipping clutch adjustment 6 Output-shaft right (optional: left) 7 Optional: WS 905 control panel 8 Cover 6 Permitted installation: horizontal (as shown) or vertical (motor to the top) Subject to alterations. (_Cf).0

. ST 6.5 ST 0. 7 8 5 6 Worm gear with friction clutch Motor Terminal box / optional: integrated limit switch Magnetic brake 5 Hand wheel for friction clutch adjustment 6 Output-shaft right (optional: left) 7 Optional: WS 905 control panel 8 Cover ST 6.5 ST 6. ST 0.5 ST 0. L 57 9 80 Permitted installation: horizontal (as shown) or vertical (motor to the top). ST 60.5 ST 80. SG5R 7 8 6 5 Worm gear with friction clutch Motor Terminal box / optional: integrated limit switch Magnetic brake 5 Friction clutch adjustment (SW 7) 6 Output-shaft right (optional: left) 7 Optional: WS 905 control panel 8 Cover ST 60.5 ST 60. ST 80.5 ST 80. L 57 56 59 57 Permitted installation: horizontal (as shown) or vertical (motor to the top). Emergency manual operation optional Hand crank operation NHK Rapid hand chain operator SK ( SG50) Hand chain operator KNH ( SG85 / SG5) Read note in.5.0 Subject to alterations. (_Cf) For Series Part no. L H SG50 SG85 SG5 00059 00079 000 55 5 65 9 9

5. Attachments / Accessories 5. Mounting base ST 9.5 ST 0. 5. Housing ST 9.5 ST 0. ST 6.5 0. ST 9.5 / 9. Part no. 000 Right- or left-hand use Housing Part no. 0005 Right- or left-hand use Locking cpl. for housing Part no. 00066 units 5. Sprockets / chain Chain (p x b) Description Part no. B- (/ x 7/6 ) 6 B- ( x 7,0mm),0m 5,0m Link,5m 5,0m Link 00000 00909 000065 000509 0090 000067 Sprockets for Designation Teeth s Part no. D K D 0 D n D i B H ST 9.5 / ST 9. ST 6.5 ST 0. ST 60.5 ST 80. B- (/ x 7/6 ) 0000,9 90 5, 0 6 B- ( x 7,0mm) 9 0000 65 5, 00 0 6, 5 6 B- ( x 7,0mm) 9 0000 65 5, 00 50 6, 5 5. C-profile For For Chain Part no. A B C S ST 9.5 / ST 9. ST 6.5 ST 80. B- (/ x 7/6 ) 007 9,5 6 B- ( x 7,0mm) 008 8 9 0,5 5.5 Chain-tensioner For For Chain Part no. L ST 9.5 / ST 9. ST 6.5 ST 80. B- (/ x 7/6 ) 0000 00 6 B- ( x 7,0mm) 00065 50 Subject to alterations. (_Cf).05

Door controls for ST WS 905 TS 00 WS 905 Reversing contactor control WS 905 Technical data Suitable for ST with NES mechanical limit switch Supply voltage: N~0V, PE ~0V, PE N~00V, PE Control voltage: V AC reversing contactors Permissible temperature range: -0...+50 C Housing Dimensions W x H x D [mm]: 5 x 0 x 09 Protection class: IP5 Design Mechanically locked reversing contactors Positioning button CLOSE / OPEN Plug-in connection cable to for configuration with integrated mechanical limit switch NES Available with optional readywired CEE plug, regarded as mains circuit breaker under the terms of EN 5. Functions Operating mode: Hold to run CLOSE / OPEN via an external control device TS 00 TS 00 Automatic door control Technical data Suitable for ST with DES digital limit switch or NES mechanical limit switch Supply voltage: N~0V, PE / ~0V, PE / N~00V, PE Control voltage: V DC Mains supply ratings for external devices: V DC (0.5A) / 0V AC (A) integrated reversing contactors (up to kw motor power) Display for programming ( lines with 0 signs) Permissible temperature range: -0...+50 C Housing Synthetic housing with transparent cover, Dimensions W x H x D [mm]: 0 x 00 x 85 Protection class: IP55 Design Plugged terminals with screw connections Pluggable cable sets to the with DES or NES Integrated push buttons for the adjustment of the door positions in use with DES Connectors for control devices ( for the door area, for gatekeeper operation) Functions Automatic detection of DES or NES limit switches Intermediate open position for passengers (for use with NES is an additional limit switch required) Convinient adjustment via selector switch and display status Adjustment of the door final positions and intermediate positions from the operator level (DES) Self-hold in both directions, in case of failure - automatic switching to Hold to run mode Safety edge system 8k, evaluation for 6 safety edges Connection plugs for control devices with next function (pull switch or external radio receiver) Integrated timer with week program, OFF via external switch Automatical run-time monitoring (real runtime + 8%) Automatic closing feature adjustable (-999 sekc.), adjustable in steps of seconds Possibility of adjustable clearance time (-99 Sek.) Separated adjustment of the automatic closing function for complete- or partially opening Adjustable function of the traffic lights in the final door positions or the clearance time Adjustable reaction of the photo cell in the final limit position OPEN Fault memory Cycle counter (non-resettable) and maintenance cycle counter Modul with Relays for the final door positions and faults (potential free) Subject to alterations. (_Dc).0

Connection options TS 00 Slot for inductive signal transmission (ASO) Slot for -channel radio 6 safety edges 8 K x x x V / 0.5 A External Potential-free signal contacts Slot for loop detector N~0 V, PE ~0 V, PE N~00 V, PE 0 V /.0 A External Door controls and accessories Designation Description Part no. WS 905 - Reversing contactors V For drives without limit switch; with 0.8m cable and connection plugs for, without CEE-plug 0090500.0000 WS 905 - Reversing contactors V For drives with limit switch; with 0.8m cable and connection plugs for, without CEE-plug 0090500.000 TS 00 ST-door control for DES/NES 000000.0000 5 DES connection cable for TS 00 NES connection cable for TS 00 Inductive signal transmission (ASO) 5 Connection to drives with digital limit switch, pluggable on both sides; length of cable:.0m Connection to drives with mechanical limit switch, pluggable on both sides; length of cable:.0m Modul for TS 00 for monitoring of inductive signals from safety edges (brand ASO) 0000.0000 00087.0000 000 7 6 Radio receiver -channel Loop detector -channel 6 7 Modul for TS 00 (for Opening and Intermediate opening) Modul for TS 00 (for OPEN- and CLOSE signal) 008 0065.0 Subject to alterations. (_Dc)