SPECIFICATION SHEET. C5000 ( cfm)

Similar documents
CH5000 Heat Recovery Ventilator

A. NU2035 HRV Specifications NU2035

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

This series of H/ERVs is highly customizable and purpose built for the project it was designed into. See the nomenclature details that follow.

D M S 760 C01 A A 1 1

SOLUTION AIR HANDLING UNIT PERFORMANCE SPECIFICATION

Multi-Path RTU-TYPE 9 (RTU-1) CES-MPU-025-RE-VAV9

PCB COMMERCIAL SERIES

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

TORIN by: AIRDEX Index Page No.

200, 9200 & 9200-VIB SERIES

RERV & RERVX RERVLP. Rotary Energy Recovery Ventilators. Low Profile Indoor Rotary Energy Recovery Ventilators

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

Factory Option Codes L M E S P R D V F F H E

The newest addition to RenewAire s broad line of Energy Recovery Ventilators.

ERU ENERGY RECOVERY UNIT

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

AIR-AIR ENERGY CONSERVATION MODULE

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ


"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

Warm. DFC Direct Fired Gas Heating System. Applied Air. Keeps You. Technical Guide for: Outdoor Mounted Units To 100,000 CFM And 14M BTUH

Direct Gas-Fired Heating

Centrifugal Filtered Supply Roof Blowers

ENERGY RECOVERY SYSTEM 60 HZ

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

XeteX, Inc. All Rights Reserved.

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

Q6SP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

DTC Series. Submittal Data Form 3- TO 5-TON SINGLE-PHASE PACKAGED AIR CONDITIONER

Filtered Kitchen Supply Packaged Ventilator

Product Data Manual. ERV5000i/e ERV6500i/e ERV8000i/e ERV10000i/e

SUNLINE 2000 SINGLE PACKAGE AIR - TO - AIR HEAT PUMPS DESCRIPTION. B1CH 180 & and 20 NOMINAL TONS ( EER)

Comfortable. Cooling/Heating Comfort Systems. Applied Air. Keeps You. Technical Guide for: IFL TGIFL-4

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

DCG Series. Submittal Data Form. 7½ - 12½ Ton Packaged Gas/ Electric Up to 11.3 EER / 80% AFUE

VHIA High-Static Ducted Indoor Units - 60HZ

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

Prepared By : Checked By : Approved By : Page 1 out of 6

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

The highest energy recovery available.

Ruud Commercial Achiever Series Package Gas Electric Unit

Rheem Commercial Classic Series Package Gas Electric Unit

CPG Series. Submittal Data Form. 3- to 6-Ton Self-Contained. Packaged Gas/Electric. with R-410A

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 7.7 HSPF Three Phase, Packaged Heat Pump 3-5 Ton Units WARRANTY

Submittal DIMENSIONS SIZE FAN SIZE L W H C D E F G J K [406] [508] 25 [635] [406] 16 [406] 16 [406] 39-1/2 [1003] 44-1/2 [1130] 51 [1295] 59 [1499]

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

SUBMITTAL. Palm Beach Gardens Fire Station. Fausto Frias

VAHU Vertical Air Handling Unit

Product Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015

ROOF TOP SINGLE AND DOUBLE WALL BELT DRIVE AIR HANDLER DX OR CHILLED WATER COOLING HOT WATER OR ELECTRIC HEATING

14 SEER R -410A PACKAGE DUAL FUEL HEAT PUMP 2 to 5 TONS Two -Stage, Gas Heating / Electric Heating and Cooling Unit

Ruud Commercial Achiever Series Package Gas Electric Unit

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

MODEL IFG INDIRECT FIRED MAKE-UP AIR HEATER

CPC Series. Submittal Data Form. 15- & 20-Ton Self-Contained. Packaged Air Conditioner. with R-410A

ERV. Energy Recovery Ventilators. Capacity: 400 to 4,000 cfm Model: ERV500i/e, ERV1000i, ERV1500i/e, ERV2000i/e, ERV3000i/e

OmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide

ASHRAE 90.1 COMPLIANT PACKAGED ROOFTOP ELECTRIC COOLING UNITS, R 410A, TONS 3 Phase, 50 Hz. BUILT TO LAST, EASY TO INSTALL AND SERVICE

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Tons BTU/h S.E.E.R* E.E.R** HSPF

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

R6GP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Gas/Electric Units, with R-410A WARRANTY

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

FEATURES AND BENEFITS

Sizes 156, 180. COOLING HEATING (High Temp) Unit Dimensions. COOLING HEATING (High/Low) Unit Dimensions

CHP

Z-Series Rooftop Units 50 HZ

TECHNICAL SPECIFICATIONS

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

COMMERCIAL HIGH EFFICIENCY PACKAGE AIR CONDITIONER UNITS R 22 SINGLE PACKAGE ROOFTOP 3 5 TONS (3 Phase 575 Volt)

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CEILING CONCEALED LOSSNAY LGH-50RX3

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

WATER SOURCE HEAT PUMPS

Product Data. Features/Benefits. 50TFQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

Product Data. Features/Benefits

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

PHR5. Product Specifications

R6GN Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units with R-410A WARRANTY

REPLACEMENT PARTS MANUAL

Product Data. Features/Benefits. 50TJQ Single-Package Standard Efficiency Rooftop Heat Pump Units. 3 to 10 Nominal Tons

August PRODUCT DESIGN GUIDE Inteli-line Vertical Stack Fan Coil with Slide-Out Chassis

REPLACEMENT PARTS MANUAL

Industry best 5 year fan housing warranty, 1 year motor warranty

HRV. Heat Recovery Ventilators. Capacity: 300 to 1,260 cfm Model: HRV600i, HRV700i, HRV1200i

TECHNICAL GUIDE DESCRIPTION SINGLE PACKAGE AIR CONDITIONERS AND SINGLE PACKAGE GAS/ELECTRIC UNITS PRELIMINARY DATA

ROOFTOP UNITS 60 HZ P A C K A G E D H E A T P U M P

Transcription:

(3500 5500 cfm) CASING Double wall cabinet White exterior paint, 22GA steel Galvanized 18GA steel inner wall Access door with ¼ turn handle Insulation : 2 in 18GA Stainless Steel drain pan Drain connection : 1 in NPT MOUNTING On roof curb or on platform BLOWERS Type: Forward curved (pillow block) Permanently sealed and lubricated ball bearings Diameter: 15 in Width: 10 in Shaft : 1 3/16 in Power transmission by adjustable pulleys and belts Outdoor unit MOTORS Type: Inverter duty 10:1, PREMIUM* efficiency, ODP Speed: 1800 rpm Maximum power : 10 HP Drive assembly/blower : on anti vibration isolators (spring) * T frame only FILTERS Type: MERV8 Quantity: 6/circuit Dimensions: 16 in X 20 in X 4 in CORE Enthalpy (quantity : 2, pitch : 3.3 mm, dimensions : 22.62 in X 22.62 in X 30 in) Indoor unit WARRANTY Core : Limited ten years warranty All other covered components : Limited two years warranty CERTIFICATION Licenced to use the following label of approval NET WEIGHT* (LBS) Min. : 3100 lbs [1406 Kg] Max. : 5200 lbs [2359 Kg] *Depending on options and construction 1

(3500 5500 cfm) CONTROLS Start/stop dry contact and general alarm dry contact Dry contact for occupancy control Terminals for fresh air damper power and control (24VAC, 10VA) Terminals for exhaust air damper power and control (24VAC, 10VA) Power 24VAC 20VA available for accessories Low temperature limit: unit will stop if fresh air supply is under setpoint (adjustable) for more than 5 minutes. Access panel with non fused disconnect (NEMA 4) Single point power connection BACnet compatible controller (communication module is optional) Available power (Volt/Ph/Hz): 208/1/60* 230/1/60* 208/3/60 230/3/60 460/3/60 575/3/60 *to be approved DEFROST Frost control is activated by a temperature reference (Set point: enthalpy core: 10 C) Pre heating, electric coil inside unit, SSR control Pre heating, hot water coil inside unit (0 10V signal available at the control panel, piping connections at rear) By pass damper (fresh air deviation) inside unit Defrost cycles, evacuation or recirculation, (c/w motorized and isolated damper on OA only, see tables below for temperature references. OPTIONS Cabinet Options Intake and exhaust hoods: c/w motorized and isolated dampers. Bird screen on intake and exhaust hoods Roof curb: 14 in high, galvanized 18GA steel, optional insulation available Piping connections (drain pan, post heating water coil and/or cooling coil connections): Front or back Components Options MERV13 filters: Final MERV13 filters added to the fresh air circuit Motorized and insulated dampers (on OA and/or EA openings) Not insulated backdraft damper (on EA opening only). Backward inclined blowers (BI) Post heating coil: electric or hot water (0 10VDC signal to maintain supply air temperature, or 0 10VDC signal by others) Cold water cooling coil: Control by others (c/w 18GA stainless steel drain pan) DX cooling coil (all controls and condensation unit by others, c/w 18GA stainless steel drain pan) Blowers motors options TEFC Two speeds: two speeds motors or simple speed motors with variable speed drives for two speeds applications Variable speed: variable speed drives on motors (0 10VDC control signal by others) Exchange period (min) 35 30 25 20 15 Exchange period of a defrost cycle Standard cycles (7 min defrost) Control options Dirty filters contact: dry contact closes and message on display when dirty filters detected on either air circuit Low airflow switch (will open a dry contact when no airflow is detected on fresh air blower) Free cooling management: control of free cooling by temperature sensor on OA (available with bypass damper only) End switch on dampers: unit start up conditional to dampers opening BACnet network communication modules: MS/TP or IP Remote keypad and display Phase loss detection: unit will stop when a phase loss occurs, automatic restart CO2 detection: sequence control to be validated 10 30 25 20 15 10 5 Outside air temperature (deg C) 2

INTERNAL COMPONENTS 3

UNIT DIMENSIONS AND WEIGHT 4

AVAILABLE CONFIGURATIONS 5

ROOF CURB DIMENSIONS BP (Bypass damper) 6

ROOF CURB ASSEMBLY ROOF CURB ASSEMBLY 7

PERFORMANCES : ENTHALPY CORE 70 * Enthalpy core Efficiency 60 Efficiency (%) 50 40 30 Sensible Latent Total 20 10 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 4900 5000 5100 5200 5300 5400 5500 Air flow (cfm) Supply temperature ( C) 18 16 14 12 10 8 6 4 2 0 2 4 6 8 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 4900 5000 5100 5200 5300 5400 5500 Enthalpy core Supply temperature T2 (T3 at 21 C DB /14 C WB) T1 at 10 C T1 at 0 C T1 at 5 C T1 at 10 C T1 at 30 C Air flow (cfm) 8

INTERNAL STATIC PRESSURE Enthalpy core Internal APD 1.4 1.2 APD (inh2o) 1 0.8 APD 0.6 0.4 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 Air flow (cfm) 4900 5000 5100 5200 5300 5400 5500 MOTOR SELECTION ENTHALPY CORE HP = BHP * 1.2 9

BLOWERS PERFORMANCES 10