FL 1000 XT C DMX. User manual

Similar documents
FL 150 XT-2 B, F, and C

FL Halogen light generator for use with fibre optic lighting. Mounting and installation instruction. Item no.: FL 20-2 Ø9 230V

FL B. Halogen light generator for Fibre optic lighting systems

RobLight FL User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn. Phone:

FL Roblon Lighting. User manual. Applies to: RobLight A/S Nordhavnsvej 1A DK Frederikshavn

F L B Metal Halide Light Generator for Fiber Optic Lighting Systems

Ara 4. Mounting and installation instructions. Item no.: Ara K black. User manual

Sirius Illuminator Range

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

P90L-ISO6MB & ISO10MB

Quick Reference Guide. English EN Español ES Français FR Nederlands NL

LyteLaunch Dry - Wet and DMX Models. Operation Manual

MOVING HEAD. User manual CAUTION!

4 - Finish. 5 - LED Style *1/ Driver Style. Wet Location Dry Location W

Light Source User Guide

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

STR9 Monochromatic. Linear LED Wall Washer and Wall grazer

USER MANUAL LUX-LD30W LED MOVING HEAD

Snapshot. User Manual BOB LED

EPS/ELA-Series User Manual EPS/ELA 250W

OBY-5. User manual MOVING HEAD CAUTION!

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

Snapshot Ok on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

QTFX-F1, QTFX-F2 FLAME EFFECT

LNT-65RGBW 3.4W IP67/IP68 COLOR-CHANGING LED STRIP

EVO LED Downlight Range

Rotator Item No 280 & 281 User Manual Rotator (280) Rotator (281)

TABLE OF CONTENTS. Page 2 of 12 DataStream 4 User Manual Rev. 2

Installation Instructions

User Manual. Snapshot. Use on Dimmer. Outdoor Use. Sound Activated DMX 512. Master/Slave. 115/230V Power Switch. Replaceable Fuse.

OUTDOOR TRACK. LABELS Assembled in America

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

Snapshot. Use on Dimmer Outdoor Use Sound-Activated DMX Master/Slave 120 V/230 V Switchable Replaceable Fuse User-Serviceable.

LED Pinspot 2. Snapshot. User Manual

FL-2R MOVING HEAD 120W

LED Pinspot 2. Snapshot. User Manual

IGLOO IGLOO EASY INSTRUCTION MANUAL

Installation Instructions

Step1: Battery and Speaker Assembly Step 2: Pump and Battery Installation Step 3: Setting Up Your Fountain 6 Troubleshooting and Maintenance

LEDtape 800 TW Tunable White K CRI>90

c-go 24V/6A 24V/8A 24V/12A

Compact LED profile with zoom

Product Innovation Award winner Architectural/Flood lighting. Exterior 400 Range. Exterior 400 Range

LED AR111 Instruction Manual

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

Pyxis & Corvus. Launch brochure

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

Transformer Module for 6-10KVA User s Manual 6-10KVA-GTM

Installation Instructions

Transformers for Low-voltage Halogen Incandescent Lamps

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Pressure chlorine changeover unit C 7520

Bubble King. User Manual

CH-158 Color Bank 8 USER MANUAL

USER MANUAL MOMENTS COLLECTION

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

FL15 FL50 FL100 USER MANUAL USER MANUAL FL15 PRODUCT OVERVIEW HARDWARE AND SET-UP. page 1

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Operation Manual. Mega 4Bank DMX Universal

iw Fuse Powercore Linear interior LED wall grazing luminaire with intelligent white light

GP12 TECHNICAL MANUAL

Product Guide: Series III Pump Control Board Set (RoHS)

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

Light is universal OPTOTRONIC LED drivers

Measurements are expressed in millimeters.

1 Safety instructions

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog


Operation Manual. Select/DMX 4Bank

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

TUNNEL LED LIGHTING. High power, low consumption public LED lighting

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

Battery Safety Instructions 4 Garden Fountain Parts List 7 Step1: Battery Installation 8 Step 2: Setting Up Your Fountain 11

STR9-SLIM. Low Profile Monochromatic Linear Wall Washing and Grazing LED Lighting SPECIFICATION LOGIC: STR9 SLIM PRODUCT SPECIFICATION SHEET DATE:

OPTOTRONIC Programmable LED Emergency Driver and Battery Pack

LED RECESSED LIGHTS Rev./150827/CLZ

Instruction Manual Installation and Operation Guidelines for DWL5000XY and DWL5500XY Tilt Sensor Modules (Version 2.2)

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

WATERFLUX 3070 Quick Start

DBC-1 DEIF Battery Charger

Woertz 3G2.5 mm 2 and Woertz 3G4 mm 2

1. Before You Begin What Is Included... 3 Unpacking Instructions Claims Product at a Glance... 3 Safety Instructions...

PRELIMINARY. D40 Studio ETC. Selador Desire Series ORDERING INFORMATION GENERAL INFORMATION. Desire CE D40 Studio

FR5050X60WH10. LEDwise Strip Light SPECIFICATION SHEET DESCRIPTION DESCRIPTION. Rev1605

Bubble Machine. User Manual

LED STREET LIGHTS Rev./150617/AL

Indoor- Outdoor - Pool Cordless LED Bulb & lamp shade

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

75% ENERGY SAVINGS 200W-600W HID Light Replacement

12-in-1 CABLE TESTER. User Manual CBT-12

MyGel Mini. Operating Manual Version 1.2. a division of. Electrophoresis System. 6 Troubleshooting (continued) Problem Causes Resolutions

Via Michelangelo Buonarroti, 52/B Cologno M.se (Mi) USER S MANUAL

In-Place-Inclinometer Installation Manual

INDEX PAGE WHERE LIGHT CREATES COLOUR SERIES, EDITION 01

LED Wall Sconce. Offered with a frosted lens, these wall luminaires provide a high quality diffuse light due to their high CRI of more than 90.

Transcription:

FL 1000 XT C DMX LED light generators with DMX controlled colour or twinkle wheel. Dual light generators with both color and twinkle. All units with DMX controlled dimming 0100%. User manual Item no.: 0123 6310 FL 1000 XT C DMX Colour 3000K 0123 6315 FL 1000 XT C DMX Twinkle 3000K 0123 6320 FL 1000 XT C DMX Colour 4000K 0123 6325 FL 1000 XT C DMX Twinkle 4000K 0123 6410 FL 1000 XT C DMX Dual 3000K 0123 6420 FL 1000 XT C DMX Dual 4000K +99082098 02.11.2015

Contents. 1 Introduction 2 Product overview when unpacking 3 DMX addressing the light generator 3.1 Factory default setting 3.2 Factory custom set up addresses 3.3 Setup of the DMX adresses on site 4 DMX protocol 5 Surfacemounting 6 Installation 7 Installing in closed compartments 8 Installing one or more light generators 9 Technical data 10 Spare parts 11 Accessories 12 Troubleshooting 1. Introduction. Roblon FL 1000 XT C DMX light generator with DMX controlled colour and twinkle wheel as well as very smooth controlled dimming are designed for use outdoors with glass or PMMA fibre in all installation setups, including in closed compartments. Weatherproof, waterproof LED light generator. Cuts energy consumption by min. 63% compared with equivalent halogen generators. For functional and decorative tasks outdoors and in wet locations. Ideal for fountains, public art, facades, signage, parks, gardens and swimming pools Follow the installation instructions correctly in order to ensure safe operation enhanced functionality extended lifetime for components uninterrupted illumination 2

2. Product overview when unpacking the light generator. FL 1000 XT C DMX light generator Allen key Screws w/ plugs User manual Light port OUT DMX IN DMX signal and programming Connect wire to mains 3

3. Addressing set up of the light generator: 3.1. Factory default setting: Factory default Address settings are as follows: Electronically setting: CH1 dimming 0100% CH2 Dimming 16 bit (High resolution 65536 levels). Mecannically setup directly on the hardware inside the unit: CH3 DMX addressable special functions. CH4 Colour wheel. CH5 Twinkle wheel. 3.2. Factory custom set up addresses: You can order a custom addressing (part number 9903 0071) of the unit when ordering the light generators. The light generators will be supplied with a label informing about the settings. 3.3. Setup of the DMX addresses on site: 3.3.1. Please note that the following steps requires a skilled technician. And that working on a light generator with the lid off requires a trained electrican. Use caution! Turn the light generator upside down and remove the eight screws and then remove the lid and sealing. On www.eldoled.com/software download software for eldoled TOOLbox pro: eldoled FluxTool software v1.04 MAC.zip eldoled FluxTool software v1.04 WIN.zip or eldoled Showmaster DMX software v 1.5.zip Download and follow user manuals in: User manuals/accessories/user Manual TOOLbox PC Software v1.0.pdf. Connect TOOLbox as shown and follow eldoled manual. eldoled TOOLbox pro 0160 0336 120 240V 4 Programming cable 0160 0337 DMX in

According to DMX protocol driver address should be set to light generator desired DMX address. Driver: Channel 1: Dimming 0100% light Channel 2: Dimming. Fine resolution, 16 bit (LSB: Least Significant Bit). (One DMX channel represents a number from 0 to 255 which is a 8 bits number. In order to have more than 256 DMX steps, two channels can be combined (256 times 256). This is called 16 bits resolution). 3.3.2. Wheel control board code on driver. Wheel must be set to driver DMX address +2. Example: DMX address 1 on driver wheel sets to address 3 DMX address 8 on driver wheel sets to address 10. x1 x10 x100 Light generator channel CH 1 CH 2 CH 3 CH 508 Driver 1 2 3 508 Wheel control board 3 4 5 510 3.3.3. When the light generator is addressed replace the sealing and the lid and fasten the screws on cross to example as shown to up. Beware of the sealing: it has to lay plain on the light generator but may not be destroyed. It is critical to be IP 65. 5 3 7 1 2 8 4 6 5

Connecting the light generators. FL 1000 XT C DMX # 1 Address X FL 1000 XT C DMX # 2 Address X + 4 Controller Address (First used channel in light generator) DMX OUT DMX IN 4. DMX protocol. CH 1 0 255 0 100% light intensity CH 2 0 255 Hi res 16 bit dimming (LSB) Control: 5 sec. delay on all functions CH 3 000 050 051 070 071 080 081 100 101 120 121 144 145 160 161 179 180 255 Not assigned Shortest mode Not assigned Linear mode Not assigned Reset wheel Not assigned Reset wheel Not assigned 6

CH 4 000 200 000 / 200 033 067 100 133 167 Colour wheel: Position of wheel White Green Orange Blue Red Yellow 201 205 Not assigned 206 207 Variable speed of rotation clockwise (10 rpm.) 208 210 Variable speed of rotation clockwise (5 rpm.) 211 212 Variable speed of rotation clockwise (3 rpm.) 213 215 Variable speed of rotation clockwise (2 rpm.) 216 219 Variable speed of rotation clockwise (1 rpm.) 220 Variable speed of rotation clockwise (0.8 rpm.) 221 223 Variable speed of rotation clockwise (0.6 rpm.) 224 225 Variable speed of rotation clockwise (0.4 rpm.) 226 228 Variable speed of rotation clockwise (0.2 rpm.) 229 230 Variable speed of rotation clockwise (0.1 rpm.) 231 232 Variable speed of rotation counter clockwise (10 rpm.) 233 235 Variable speed of rotation counter clockwise (5 rpm.) 236 237 Variable speed of rotation counter clockwise (3 rpm.) 238 240 Variable speed of rotation counter clockwise (2 rpm.) 241 244 Variable speed of rotation counter clockwise (1 rpm.) 245 Variable speed of rotation counter clockwise (0.8 rpm.) 246 248 Variable speed of rotation counter clockwise (0.6 rpm.) 249 250 Variable speed of rotation counter clockwise (0.4 rpm.) 251 253 Variable speed of rotation counter clockwise (0.2 rpm.) 254 255 Variable speed of rotation counter clockwise (0.1 rpm. ) 7

CH 5 000 200 000 / 167 033 133 Twinkle wheel: Position of wheel White / open Only twinkle 201 205 Not assigned 206 207 Variable speed of rotation clockwise (10 rpm.) 208 210 Variable speed of rotation clockwise (5 rpm.) 211 212 Variable speed of rotation clockwise (3 rpm.) 213 215 Variable speed of rotation clockwise (2 rpm.) 216 219 Variable speed of rotation clockwise (1 rpm.) 220 Variable speed of rotation clockwise (0.8 rpm.) 221 223 Variable speed of rotation clockwise (0.6 rpm.) 224 225 Variable speed of rotation clockwise (0.4 rpm.) 226 228 Variable speed of rotation clockwise (0.2 rpm.) 229 230 Variable speed of rotation clockwise (0.1 rpm.) 231 232 Variable speed of rotation counter clockwise (10 rpm.) 233 235 Variable speed of rotation counter clockwise (5 rpm.) 236 237 Variable speed of rotation counter clockwise (3 rpm.) 238 240 Variable speed of rotation counter clockwise (2 rpm.) 241 244 Variable speed of rotation counter clockwise (1 rpm.) 245 Variable speed of rotation counter clockwise (0.8 rpm.) 246 248 Variable speed of rotation counter clockwise (0.6 rpm.) 249 250 Variable speed of rotation counter clockwise (0.4 rpm.) 251 253 Variable speed of rotation counter clockwise (0.2 rpm.) 254 255 Variable speed of rotation counter clockwise (0.1 rpm. ) 8

5. Surfacemounting. 5a Surfacemounting. 1. Attach to surface using two screws in the baseplate holes. 2. Vertical installation: to maintain IP 65 protection, mount with the light port facing down. 170 mm between Ø6 mm holes 5b Bracketmounting. 1. Attach the bracket (not supplied; see Accessories) to the surface using two screws. 2. Mount the light generator on the bracket. 140 mm between Ø6 mm holes 9

6. Installation. 1. Remove the plastic plug on the baseplate, directly bellow the light port. 2. Insert the common end fully in the light port. 3. Tighten the screw on the base with the Allen key. 4. Insert the plastic plug. (Important to be IP 65!) 5. Ensure all installation and ventilation requirements are met. 6. Connect the power cord to the mains. 10

7. Installing in closed compartments. Requirements: Enough space to allow natural heat transmission through surfaces Surfaces should not be insulated Air volume per light generator minimum 0.05 m³ Ventilation holes per light generator with min. 20 cm² air inlet and min. 20 cm² air outlet Inlet and outlet ventilation holes opposite each other Max. ambient temperature 45ºC. (Measuring temperature: see Troubleshooting ) (0.3 m) 0.05 m³ (0.6 m) (0.3 m) 8. Installing one or more light generators. Requirement: min. 100 mm distance between adjacent light generators in order to ensure sufficient heat transmission 100 mm 500 mm 11

9. Technical data. Light port Ø28 mm Fibre type PMMA / Glass Total power consumption @ 700 ma 26 W (Single wheel) 31 W (Dual wheel) Supply voltage 120240 V / 5060 Hz Applied LED LUXEON S1000 LXS8PW30 (3,000 K) LUXEON S1000 LXS8PW40 (4,000 K) Light source lifetime 50,000 hours CCT (nominal) 3,000 K / 4,000 K CRI8 (Ra) typical value 85 Protection rating IP 65 Driver type Electronic Driver lifetime 50,000 hours Dimmable DMX Thermal protection Integrated auto Cooling system Natural convection Noise level N/a Ambient temperature 20 C to 45 C Material EN AW5754 (AlMg 3) + POM Dimensions (L x H x W) 298 x 185 x 151 Weight 3.8 kg Safety CE, RoHS, F DMX Connection XLR 5 pin 12

10. Spare parts. Image Model designation Description Item no. Eldoled Driver Powerdrive Eldoled 50W 1104 1300 Colour wheel Standard 6 colour 5100 0085 Twinkle wheel 5100 0092 Diode LED LED module, no cooling 0129 4004 Effekt motor for DMX Stepper motor 1.8 6400 4000 Springclip 4 mm Lock for wheel 9100 6304 14

11. Accessories. Image Model designation Description Item no. Mounting bracket Bracket that can be padlocked 0126 7000 Colour wheel mix. Colour wheel special Standard 6 colour Custom specified colour wheel Rosco Permacolour Custom specified colour wheel 5100 0153 5100 0154 EldoLED TOOLbox pro 0160 0336 Programming cable for EldoLED toolbox pro RJ45 to XLR 5 pin 0160 0337 DMX adressing Addressing of light generator form factory 9903 0070 Sunlight USB Controller 0160 0302 DMX programming Programming of Controller 9903 0071 DMX Cable Cable between control unit and Light generator Please state required length 9903 0057 Springclip 4 mm Lock for wheel 9100 6304 Kit for twinkle wheel For insert in twinkle wheel to avoid constant white light. 0126 6220 14

12. Troubleshooting. Problem Trace the problem Solution No light Is the power on? Turn the power on Is the power cord connected properly? Connect the power cord properly Is the light generator too hot*? Check it is installed according to the instructions. Switch generator off. Let it cool for 15 minutes. Try again. Is the LED working? Replace the LED Is the Supply fuse intact? Replace the Supply fuse Light output has diminished Check DMX Has the light been dimmed via DMX Is the harness common end dirty? Set correct address, value and level Increase brightness using DMX Controller Clean filter with damp cloth Dry with lintfree cloth * Ambient temperature: max. 45 C. Measured 50 mm from light generator. Surface temperature: max. 73 C. Measured 15 mm from edge on top of light generator when it has been running for min. 1 hour 15

Roblon accepts no responsibility for possible errors in printed and electronic material. Roblon reserves the right to alter or discontinue products without notice. 2012, Roblon A/S Roblon Lighting Tel: +45 9620 3366 Nordhavnsvej 1 Fax: +45 9620 3396 9900 Frederikshavn info@roblon.com Denmark www.roblon.com