PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

Similar documents
IGNITION FLAME SAFETY CONTROLLER

REV 1.7 PROFIRE 2100 MANUAL BURNER MANAGEMENT SYSTEM

INSTALLATION MANUAL ACL 5500 COMBUSTION SAFETY CONTROLLER

PF 3100 ION PILOT CARD PRO.FIRE

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

REV INSTALLATION GUIDE BURNER MANAGEMENT SYSTEM

The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor

User Manual. Solar Charge Controller 3KW

User Manual Solar Charge Controller 3KW

TABLE OF CONTENTS 1 INTRODUCTION 4 SYSTEM BEHAVIOR 5 EXPANSION CARDS 6 TROUBLESHOOTING 2 INSTALLATION 3 USER INTERFACE & SETTINGS APPENDICES

Installation Manual. ACL3200 Flare Stack / Incinerator Ignition Systems

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

G76x Direct Spark Ignition Controls

Section 3 Technical Information

G72x Series Direct Spark Ignition Controls

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

Application Engineering

Operating Manual. Safety/Process Flare Pilot

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

2 INTRODUCTION. FLAME SMART Ei3

BG1600M Intermittent Pilot Ignition Control

Troubleshooting Manual

The Combustex Pilot Pro 500 Ignition System with Pilot Tip and Flame Sensor

INSTALLATION MANUAL FOR ACL 3200 FLARE STACK /INCINERATOR IGNITION SYSTEMS WARNING

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

DIESEL Engine Fire Pump Controllers Features

Application Engineering

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

G600 Series Replacement Intermittent Pilot Ignition Controls

DIFFERENTIAL PRESSURE BATTERY CHARGERS

E Series CE Approved Intermittent Pilot Ignition Control

RF Point Level Control with Sensor Monitor



SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

60 Series Engine Controls

Modulating Furnace Information. Warning on Meter Setting - Read First!

This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified.

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM).

REVISION HISTORY REVISION HISTORY

SECTION B1: MACHINE COMPONENTS

GCU-10. Automatic Engine Control Unit Operators Manual

SAVANNAH EI & DELUXE SYSTEM TROUBLE SHOOTING GUIDE

SECTION B: SYSTEM OPERATING COMPONENTS

GPS-iConnect Installation Operation & Maintenance Manual

CAUTION All safety information must be followed as provided in Service Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

PT-M90 Automatic Full-Sequence Modulation Gas Control System

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

OpenEVSE - 40A Charging Station

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Section 55 Chapter 6

Battery Control Center - Diesel

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor

J1 Plug Pin Identification

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

SC SERIES SOLAR CONTROLLER USER MANUAL Ver 1.0

Operators Guide: RoboSign Stop/Go Traffic Control System

DEEP SEA ELECTRONICS PLC

J1 Plug Pin Identification

SERVICE MANUAL (INTERNATIONAL)

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

CRAGG RAILCHARGER Instruction Manual for 20SMC-12V 20SMC-24V 40SMC-12V 40SMC-24V 60SMC-12V 80SMC-12V

J1 Plug Pin Identification

Subject Underhood G System Error Codes and Symptoms System or Parts affected

Compact Sine Inverter

Generator Start Control Module

GSL Electronics Modified Sine Wave Power Inverters

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Operators Guide: RoboSign Stop/Go Traffic Control System

Installation and Operating Instructions

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

BGH2UNCNTRLHT-01 Universal Hot Surface Ignition Control

MAXIGARD A2000 SPEED SWITCH. Introduction

Energy Division

ST315B. User Handbook STAFFOR. ST315B Temperature Programmer. See separate handbook for Installation Instructions Issue: 2.00

Model VC volt to 12 volt DC to DC Converter. Table of Contents. Introduction. 2. Specifications.. 2. Operation... 2

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

G821L/G822L Series Integrated Function Direct Spark Ignition Controls

American Flame AF-4000 Series Intermittent Pilot Ignition System Trouble Shooting Guide

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

PRODUCT INFORMATION BULLETIN

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

burners with or without fan. It conforms to EN C). APPROVAL EU type test approval as per EU Gas Appliance Directive.

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

MI0559A OXY-BEVEL OPERATIONS MANUAL: Oxy-fuel contouring beveling head with manual tilt function.

SERIES VAC Microprocessor Based Direct Spark Ignition Control with Combustion Blower Relay FEATURES DESCRIPTION

Temperature Controller OVATION 214 User's Guide

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

Transcription:

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

Cautions WARNING: EXPLOSION HAZARD- -DO NOT SERVICE UNLESS AREA IS KNOWN TO BE NON- HAZARDOUS -DO NOT OPEN WHEN ENERGIZED EXPLOSION HAZARD- -SUBSTITUTION OF COMPONENTS MAY IMPAIR THE SUITABILITY FOR DIVISION 2/ ZONE 2 -REPLACEMENT FUSES MUST BE SAND-FILLED -DO NOT OPEN WHEN ENERGIZED INSTALLATION WARNING Terminal Connections: Connections must conform to the directions in this manual. The unit must be properly connected to earth-ground for effective ionization operation. Electrical devices connected to the controller must meet electrical standards and be within voltage limits. Contact Number For any questions call: 780-960-5278

Table of Contents Introduction 1 Features 3 Specification 4 Installation 5 Function diagram 13 Standard parts 14 Spare parts 15 Trouble-shooting 16 Key-pad functions 6 Wiring Diagram Rev 4.09 7 Coil 8 Pilot assembly 9 Program Mode 10 Program menu 11 Changing settings 12

Features of the Profire 1100i CSA compliant for: 1. Class 1, Division 2 locations approval (CSA 213-92). 2. Industrial Process Equipment approval (CSA 14-95). Input Power +10 to +28 VDC. Dual Flame-sensing modes: 1. Thermocouple (type K thermocouple). 2. Flame Rod (ionization circuit) Rapid 1.8 second shut-down on flame-out. DC Voltage spark generator. Low-power design to incorporate solar panels or TEG applications. Auto relight or manual operation, push button selectable. Remote Start/Stop control. Large, easily-accessible terminal connections. Equipped with AVD (Advanced Visual Display) for improved operating functions and signals. START-LOCKOUT input for connections to safety interlock devices. All circuits are transient protected and are fail-safe. 3

Specifications E N C L O S U R E Fiberglass 8" x 6 x 4" CSA and UL compliant for Class 1, Division 2 locations Enclosure type 4, 4X, 12, 13 C I R C U I T B O A R D S All solid state, CPU base CSA compliant for Class 1, Division 2 locations I G N I T I O N B A S E A N D C O I L For non-classified area only P O W E R R E Q U I R E M E N T S +10 to + 28 volts DC S U P P L Y C U R R E N T 2.0 amps surge (limited), 0.015-2 amps run P O W E R C O N S U M P T I O N 1100i only: 12 volts - Display on - 106 ma or 1.3 watts 12 volts - Display off - 43 ma or 0.6 watts 24 volts - Display on - 66 ma or 1.6 watts 24 volts - Display off - 35 ma or 0.9 watts Operating Conditions: 40 C to +55 C 4

Installation Site Selection The Profire 1100i system enclosure is CSA compliant for a Class 1, Division 2 (C&D) area classification. This means the system enclosure must be mounted outside any Class 1, Division 1 area. The system can be mounted on the unit skid or on a building wall as long as it does not infringe on a Class 1, Division 1 area. The Profire 1100i system enclosure is a fiberglass box 8" x 6" x 4", complete with mounting tabs. The enclosure weighs less than 5 pounds, so heavy duty supports are not required, but the unit should be firmly mounted as the push buttons on the front panel have to be operated. The enclosure should be mounted in a location that faces away from the burner housing so that the operator is facing both the enclosure and the burner housing while operating the unit. Other considerations are panel access, traffic, wire-runs, and visibility. The enclosure should be mounted about 5 1/2 feet above ground level. The spark generators, however, must be mounted in a non-classified area, as there is a potential of a spark arcing across the output terminals of the coil or along the insulated high voltage leads. The ideal location for the spark generator is inside the burner housing or in an approved enclosure for the area. 5

Key-pad function Flame light indicates presence of flame 1 3 ESD push-button 4 Display window Key-pad for parameter adjustments and field settings 2 Switches between auto and manual modes 5 6 Manual button. Also used for testing on start-ups. 1 2 3 4 5 6 Flame light indication: Allows operator to see that the pilot is lit. Key-pad: Allows operator to select adjustable field parameters on the unit. "PROG" button selects the mode in which the adjustments are allowed. "UP" button scrolls up though the menu."down" button scrolls down through the menu."ok" button will allow system to accept changes. ESD: Allows operator to manually shut unit down, and alarm. Display window: Allows operator to read pilot flame temperature, menu, and errors that have occurred. Mode: Allows operator to switch unit into a manual mode to check pilot ignitor and pilot solenoid, providing all safety interlocks have been met. LED's indicate the state the unit is in. IGNITE button: Allows operator to activate ignition, providing all safety parameters are met and unit is in manual mode. 6

Wiring connections for the Profire 1100i For good connections, spade connectors should be used and wires should be clearly marked. Terminal Board Connections Alarm Signal Dry contact N.O. STATUS+ STATUS- 12/24vdc+ common DC Power Supply Input +12 VDC or +24 VDC Dry contact Closed to start Open to stop Dry contact Closed to Run Open to ESD Main fuel solenoids up to two in parallel 2 Amp output START+ START- ESD+ ESD- MAIN+ MAIN- ground LCK+ LCK- TC+ TC- TCS Proof of closure switch Switch closed to start ignition sequence Thermocouple connection to type 'k' probe for pilot flame Main fuel solenoids up to two in parallel 2 Amp output PILOT+ PILOT- COIL+ COIL- Voltage output to coil with Ionization return to unit High and Low fuel switches in series. Dry contact, closed to run PR.SW+ PR.SW- COIL-I COIL-G Grounding is required Rev. 4.09 7

* Coil must be mounted in a NON-HAZARDOUS location. Coil requires solid ground from Profire 1100 to ensure ionization operates properly. 90 mm 45 mm C/C Mounting hole size 8 mm (1/4" bolt) 130 mm 115 mm C/C Coil Spark lead to pilot electrode / Flame Rod Coil Power Ion + - Coil height 110 MM Coil ground from panel to housing Ionization output to panel Coil power contact Top view 8

Pilot bracket assembly Pilot mounting bracket. Standard size for 1/2" pipe. Comes with electrode bushing and probe fitting. Type "K" thermocouple probe 2" past pilot nozzle with a 30 bend Ignition cable. Five foot carbon lead with end connections for electrode and coil. Kanthol electrode, ignitor and flame rod. Bend in a fashion that the gas will ignite. Pilot bracket assembly can be mounted on existing pilot. Brackets can be ordered to fit pilots 1/2" and up. Slip-stream applications are also acceptable, but may require custom length probe and ignition electrode. Pilot burner is not included. Available as option 9

Program Mode On Screen Description Function Default setting AU Enables unit to automatically start on power-up ON= Auto start enabled OFF = Auto start disabled Off HI High set point (Spark) Signal setting for a spark trigger point in Celsius. Sparks when below this setting. 600 LO Low set point (Alarm) Signal setting for a prove point / alarm point in Celsius 200 LEd Power saving Allows unit to turn LEDs off on 10

Program Menu PROGRAM AU ON OFF HI Hi set point C LO Low set point C LED Allows LED to shut off OK 11

Changing settings Changing settings can only be done when unit is in manual mode and displaying RDY. Using the front key-pad buttons, select PRG. Scroll through pushing the DOWN key to the menu that will be changed. Once the system displays the menu, changes can be selected by the UP or DOWN buttons. The change will only be accepted if the OK button is pushed. Flame mode The Profire 1100i has two method of flame detection: (1) Type K thermocouple probe, (2) Flame rod (ionization). Combined, they provide a safe and reliable flame detection system. The thermocouple probe provides low and a high set points, which indicate the flame temperature of the pilot. Running the Ionization circuit in conjunction with the probe, detects a flame-out within 1.8 seconds. Hi and Low set points Setting the high set point can be done once the lowest running temperature of the flame has been established. This can be done on the initial start-up of the unit. Typically the pilot temperature can be used, but on occasion, the main burner can effect the flame temperature of the pilot. If that is the case, one should use the lower of the two flame temperatures as a guideline to setting the Hi set point. The unit should then be shut down ensure the setting is where it needs to be. Only under special circumstances will the low set point need adjustment. 12

Function Diagram 1 Main Enabled Normal running condition High-set point Sparks Low-set point Alarms / ESD Pilot and Main Disabled Pilot Flame Temperature Time Type K Thermocouple Output Chart TEMP C TYPE K MV Default settings are bolded. TC OUTPUT TEMP. C TYPE K MV TC OUTPUT 40 1.611.401 560 23.198 5.740 60 2.436.605 600 24.902 6.161 100 4.095 1.015 640 26.599 6.581 140 5.733 1.420 660 27.445 6.790 160 6.539 1.620 700 29.128 7.206 200 8.137 2.015 740 30.799 7.619 240 9.745 2.413 760 31.629 7.825 260 10.560 2.614 800 33.277 8.232 300 12.207 3.022 840 34.909 8.636 340 13.874 3.434 860 35.718 8.836 360 14.712 3.641 900 37.325 9.233 400 16.395 4.057 940 38.915 9.626 440 18.088 4.476 960 39.703 9.821 460 18.938 4.686 1000 41.269 10.209 500 20.640 5.107 1060 43.585 10.781 540 22.346 5.529 1100 45.108 11.158 13

Standard Parts Sheet Call 780-960 5278 Enclosure Part Number Description Profire 1100i 780021i Complete standard package Door pad with electronics 780022i Front key-pad c/w electronics Door card 780023i Electronics only for the door Terminal card 780024i Terminal card only Coil assembly Coil Part Number Description 780034i Coil base 780038i Base mount Coil 780040i Ignition coil Complete coil assembly with base mount Pilot Part Number Description Pilot bracket assembly 780086i Probe fitting 780088i Tube fitting Complete pilot assembly with probe and electrode Electrode 780089i Ignitor rod with porcelain Electrode bushing 780087i Mounting bushing for electrode Pilot bracket 780040i Welded bracket Accessories Part Number Description 5 FT. 780010i Probe 6 FT 780011i 8 FT. 780012i All probes come 12 with optional extension length available. Custom Custom Ignition Extension cable 5 FT. 780100i 6 FT. 780101i 8 FT 780102i Custom Custom Extension wires come complete with ends. Optional lengths available. 14

Recommended spare parts Pilot mounting bracket. Standard size for 1/2" pipe. Comes with electrode bushing and probe fitting. 1 2 Type "K" thermocouple probe 2" past pilot nozzle with a 30 bend Ignition cable. Five foot carbon lead with end connections for electrode and coil. 3 Kanthol type electrode, ignitor and flame rod. Bend in a fashion that the gas will ignite. 4 1 Bracket part# 780086 2 3 4 Probe 12" with 6' lead part# 780011 Ignition wire extension 5' part# 780100 Ignition rod part# 780089 15

Trouble Shooting Always ensure proper voltage is applied; +10 to +28 VDC. Earth ground is required. Symptom Cause Action Screen flashes 999 Err 1 Check probe connections. Check probe. Start sequence initiated while FLAME is detected. Replace probe. Check pilot for flame. Reset system Err 2 Configuration memory failure. Replace door card. Err 3 Err 5 PILOT button pressed for more than 30 seconds. Thermocouple connection disconnected. Clear and restart sequence. Check Probe. Err 20 Internal self-check fault. Replace door. No spark Pilot light on but solenoid will not open. Flame light on in Fail mode Have pilot but no flame light Check pilot electrode gap. Check ignition wire. Check terminal board output to solenoid. If there is no power on terminals, reset system. Ionization circuit is closed. Clean pilot. Check coil connections. Ionization circuit does not see flame Replace ignition wire. Replace door card. Check pilot for flame. Reset system. Check ignition cable connections and ignition gap 16