Medium Voltage current limiting Fuse links

Similar documents
Medium Voltage current limiting Fuse links

High voltage high-breaking capacity VV fuse-links

Current Limiting Fuses, CEF Motor Circuits Fuses, CMF. Catalogue 1YMB en. Industrial IT. enabled

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

FUSES. Safety through quality

High voltage current limiting Fuse links type CEF

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Medium voltage products. Fuses

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Medium voltage products. Fuses

HHB. Medium Voltage Fuses British Standard. Introduction. Fuse-links for oil insulated switchgear

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

Limitor -G General Purpose Fuses

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

General information on current-limiting fuse-links. The main characteristics of the CNC fuse-links. Construction. Operating.

Low voltage NH knife-blade fuse-links

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

High-voltage high-breaking capacity VV fuse-links

HIGH VOLTAGE FUSE-LINKS HIGH VOLTAGE FUSE-LINKS WITH THERMAL STRIKER HIGH VOLTAGE FUSES POWER NEEDS CONTROL

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

High-voltage high-breaking capacity VV fuse-links

NEOZED D0 fuse-links gg 400/440VAC

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

Fuse-Links according to VDE 0670 T 402. Hi gh-voltage

High-Voltage Fuse Links according to IEC

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

IEC Standard Back-Up Fuse-Links

Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

Applications. Fuse range selection. Motors Power transformers. Voltage (kv)

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

DRIWISA HIGH VOLTAGE CURRENT-LIMITING FUSES HIGH INTERRUPTING CAPACITY INDOOR AND OUTDOOR USE

High-Voltage Fuse-Links

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

Fuses are the most effective and economic ways of protection against short circuits in m.v. installations.

RAPIDPLUS. high speed fuse links for semiconductors

MEDIUM VOLTAGE DIN Fuse-Links

INDUSTRIAL CYLINDRICAL FUSE LINKS

RAPIDPLUS. high speed fuse links for semiconductors

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

34-SDMS-02 SPECIFICATIONS FOR

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

CYLINDRICAL FUSES. 8x32. 10x38. 14x51. In REFERENCE U BREAKING CAPACITY REFERENCE U BREAKING CAPACITY PACKING (A) IEC /95/EC

Medium Voltage Distribution. Fuses. from 3.6 to 36 kv. Catalogue 2012

Connect - Contact - Control. Fuses for high-voltage switchgear F-HS, F-VS Series Ø 60. F 185.en

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

NH (H.R.C) FUSES AND FUSE BASES

MV SWITCHGEAR 511. CF / SOLEFUSE / TEPEFUSE / MGK MV current limiting fuses With thermally operated striker From 3.6 to 36 kv

Power systems Protection course

Thermal system protection of switchgear through high voltage fuse links with integrated temperature limiter under consideration of IEC 420:1990

Medium voltage fuses Medium voltage fuses

Standardized fuse characteristics

MEDIUM VOLTAGE DIN Fuse-Links

Technical Specification for 12kV and 24kV Powder Filled Fuse-Links and Fuse Holders

EUROFUSE MULTIBLOC MULTIVERT D/D0-FUSE-SYSTEM BSL NH-FUSE-MATERIAL MULTIFIX 60 CYLINDRICAL FUSE-SYSTEM MINIATURE FUSE LINKS HIGH VOLTAGE FUSE LINKS

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Special Purpose Fuses

NH DIN Dual Indication Fuse Links

MEDIUM VOLTAGE FUSES FOR CAPACITORS NORTH AMERICAN STYLE

Mica Element Support. Compacted Quartz Sand. Length B

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Use of switch-fuse combinations at the medium-voltage level for the protection of distribution transformers siemens.com/tip-cs

Medium voltage fuses - European Fuses

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.

EUROPEAN HIGH VOLTAGE FUSES

Medium Voltage Fuse Links Full Line Catalogue

NH fuse-links gtr 400VAC top indicator/live gripping-lugs size 2, 3, 4a

Technical Specification for 12kV and 24kV Current Limiting Fuse- Links for Overhead Applications

Capacitor Switching Contactors Type K3...-A, K3...-K

fuse-links & fuse holders PHOTOVOLTAIC

CYLINDRICAL FUSES CYLINDRICAL FUSES

Fuses Introductory Information

BUSSMANN. Leadership in fusible circuit protection solutions SERIES. Bussmann series Medium voltage fuse links catalogue

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Transformer bushings, type GOH. Technical guide

DRIESCHER Y WITTJOHANN, S.A. MEDIUM VOLTAGE SOLUTIONS

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

Surface Mount Fuses 0603Size> Slow Blow> S0603-S Series

Leadership in fusible circuit protection solutions

multicond Power capacitors Data sheet: multicond

3.6kV 36kV High Voltage DIN Distribution Fuses

Paramount HRC Cartridge

شركة كهرباء محافظة القدس المساهمة المحدودة

AIR CORE REACTORS. Phoenix Electric Corporation

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

CP Automatic capacitor bank

Utilisation category gl/gg 500VAC with combi indicator

HV-Fuse-links SSK type SSK 10/02

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

LOW VOLTAGE FUSES EUROPEAN NH KNIFE-BLADE FUSE SYSTEM

Technical Specification for 12kV and 24kV Powder Filled Current Limiting Fuse Links for Use in Switchgear (In Air)

Protistor size 70 gr 690VAC (IEC)

Transcription:

Medium Voltage current limiting Fuse links Type PCEF for indoor and outdoor use Rated Voltage 12-24 kv Current Rating 6 0A

1. General information P&C Medium Voltage fuse-links named PCEF are designed to protect devices in switch-gears and other equipment (distribution transformers, capacitors, motors) from thermal and dynamic effects of short circuits and overcurrents. Time-current characteristics correspond to standard IEC 60282-1, item 3.3.3., Back-up fuse. They are suitable for installation in Indoor and outdoor switchgear 2. Features The most significant features of P&C Medium voltage fuses are Low temperature rise because of low power dissipation High breaking capacity ka for 12kV and kv for 24kV Reliable sealing system against humidity irruption Low switching voltages 3. Standards P&C Medium Voltage fuse-links comply with the following standards and specifications: IEC 60282-1, Sixth edition 11/05 Current limiting fuses Application guide for the selection of high voltage current limiting fuse-links for transformer circuits IEC 60644 Specification for high-voltage fuse-links for motor circuit applications IEC 609 High-voltage fuses for external protection of power capacitors 4. Construction P&C Medium voltage fuses are designed to assure stable and reliable characteristics. The glazed porcelain tube (made in Europe) is extremely high mechanical and thermal resistant. Galvanically protected contact caps made of electrolytic copper are nickel - or upon customer request silver plated. The design and method of production of the melting elements ensures precisely tolerances and stable time/current characteristics. Fuse elements are wounded on a ceramic carrier (Star-core) and electrically welded on special copper strips. The inside of the tube is filled with quarz sand with an exactly determined granulation and chemical structure. The sand guarantees good and reliable extinguishing of the electric arc. The HRC generation of fuse link type PCEF are designed and tested according to IEC Publication 60282-1 (IEC 282-1). Dimensionally the fuse links are in accordance with DIN 436.

P&C fuse links have the following properties: - Low minimum breaking current - Low power losses - Low arc-voltage - High breaking capacity up to ka - High current limitation. Low power losses permit installation of these fuse-links in compact switchgear. PCEF fuses are of back-up type. They have a zone between the minimum melting current and the minimum breaking current where the fuse links may fail to interrupt. For PCEF fuse links this zone is very narrow with a minimum breaking current (I 3 ) of less than 3 & 4 times the rated current. 5. Overvoltages In order to be current limiting, the fuse link must generate an arc-voltage exceeding the instantaneous value of the operating voltage. The over voltage generated by the PCEF fuse link is below the maximum permissible value acc. to IEC 60282-1. The PCEF fuse link can safely be used if the system line voltage is -0% of the rated fuse link voltage. 6. Replacement of melted links The fuse links can't be regenerated according to IEC Publication 60282-1. All three fuse links should be replaced, even if only one or two of the fuse links in the three phase system have operated. Exceptions are allowed when it can be verified that the fuse links have not experienced any overcurrent. 7. Nameplate The symbols on the nameplate have the following meaning: - In Rated current - Un Rated voltage - I 3 Minimum breaking current - I 1 Minimum short circuit current for which the fuse is tested. The arrowhead on the nameplate indicates in which end of the fuse link the indicator and striker appears. Additionally this end contact of the fuse link is specially marked. PCEF-U is outdoor type.

P&C Type PCEF I n = 0 A I 3 < 3 x I n U n = 12 kv I 1 = ka High Voltage Current Limiting Fuse-Link According to IEC 60282-1 Made In Egypt 8. Melting times The characteristics are equal for all rated voltages and are recorded from cold condition. In uncertain interruption zone the curves are dotted.

9. Current limitation PCEF fuse links are current limiting. A large short circuit current will therefore not reach its full value. The diagram shows the relation between the prospective short circuit current and the peak value of the cutoff current. Substantial current limitation results in a considerable reduction of the thermal and mechanical stress on the high voltage installation. (Prospective current [ka] (rms. Indicator and striker pin The PCEF fuse link is equipped with a combined indicator- and striker system, which is activated immediately when the fuse element melts. The force diagram is in accordance with the requirements of IEC 60282-1 (IEC 282-1) and DIN 436.

11. Choice of fuse links Choice of rated voltage U N : The rated voltage of the fuse links must be equal to, or higher than the operating line voltage. By choosing the fuse link rated voltage U n considerably higher than the line voltage, the maximum arc voltage must not exceed the insulation level of the network. Choice of rated current I N : To obtain the best possible current limitation, and thereby also protection, I N must be chosen as low as possible compared to the rated current of the object to be protected. However, the following limitations must be taken into consideration: The largest load current must not exceed I N. Cooling conditions (e.g. in compact switchgear). Inrush current of off load transformers. For the choice of rated current of fuse links for protection of transformers, the relation between the power rating of the transformers, operating voltage and rated current of the fuse link is given in the table below. The same table indicates the highest rated current of the low voltage fuse link (on the low voltage side of the transformer) which gives discrimination with the high voltage fuse link. The low voltage fuse link is of the type gl (VDE) or gg/ gm(iec). Technical data (PCEF fuse)

12. Dimensions and data PCEF / 12kV Type Order code In(a) e(mm) d(mm) I1(KA) Wn(watt) V(Kg) PCEF 12-6 PCEF 12-6 PCEF 12-6 PCEF 12-6 PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12-30 PCEF 12-30 PCEF 12-30 PCEF 12-30 PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12- PCEF 12-63 PCEF 12-63 PCEF 12-80 PCEF 12-80 PCEF 12-0 PCEF 12-0 PCEF 12-1 PCEF 12-1 PCEF 12-0 PCEF 12-0 PCEF 12-0 PCEF 12-0 EGTF R12 J006AA EGTF R12 J006AB EGTF R12 J006BA EGTF R12 J006BB EGTF R12 J0AA EGTF R12 J0AB EGTF R12 J0BA EGTF R12 J0BB EGTF R12 J0AA EGTF R12 J0AB EGTF R12 J0BA EGTF R12 J0BB EGTF R12 J0AA EGTF R12 J0AB EGTF R12 J0BA EGTF R12 J0BB EGTF R12 J0AA EGTF R12 J0AB EGTF R12 J0BA EGTF R12 J0BB EGTF R12 J030AA EGTF R12 J030AB EGTF R12 J030BA EGTF R12 J030BB EGTF R12 J0AA EGTF R12 J0AB EGTF R12 J0BA EGTF R12 J0BB EGTF R12 J0AB EGTF R12 J0BB EGTF R12 J063AB EGTF R12 J063BB EGTF R12 J080AB EGTF R12 J080BB EGTF R12 J0AB EGTF R12 J0BB EGTF R12 J1AB EGTF R12 J1BB EGTF R12 J0AB EGTF R12 J0BB EGTF R12 J0AB EGTF R12 J0BB 63 63 80 80 0 0 1 1 0 0 0 0 41 41 41 41 33 33 33 33 52 52 52 52 78 78 78 78 3 3 1 1 1 1 174 174

13. Dimensions and data PCEF / 24kV Type Order code In(a) e(mm) d(mm) I1(KA) Wn(watt) V(Kg) PCEF 24-6 PCEF 24-6 PCEF 24-6 PCEF 24-6 PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24-30 PCEF 24-30 PCEF 24-30 PCEF 24-30 PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24 - PCEF 24-63 PCEF 24-63 PCEF 24-80 PCEF 24-80 PCEF 24-0 PCEF 24-0 PCEF 24-1 PCEF 24-1 EGTF R24 J006AA EGTF R24 J006AB EGTF R24 J006BA EGTF R24 J006BB EGTF R24 J0AA EGTF R24 J0AB EGTF R24 J0BA EGTF R24 J0BB EGTF R24 J0AA EGTF R24 J0AB EGTF R24 J0BA EGTF R24 J0BB EGTF R24 J0AA EGTF R24 J0AB EGTF R24 J0BA EGTF R24 J0BB EGTF R24 J0AA EGTF R24 J0AB EGTF R24 J0BA EGTF R24 J0BB EGTF R24 J030AA EGTF R24 J030AB EGTF R24 J030BA EGTF R24 J030BB EGTF R24 J0AA EGTF R24 J0AB EGTF R24 J0BA EGTF R24 J0BB EGTF R24 J0AB EGTF R24 J0BB EGTF R24 J063AB EGTF R24 J063BB EGTF R24 J080AB EGTF R24 J080BB EGTF R24 J0AB EGTF R24 J0BB EGTF R24 J1AB EGTF R24 J1BB 6,3 63 63 80 80 0 0 1 1 91 91 91 91 62 62 62 62 72 72 72 72 76 76 76 76 79 79 79 79 89 89 89 89 6 6 6 6 130 130 145 145 145 145 185 185 2 2 (P&C) Head Office: Factory: 23 Block 1312, El-Nozha Elgedidah, Heliopolis, Mubarak Industrial City Cairo, Egypt Industrial Zone 2 Tel. / Fax:+(2)26229977 El-Menoufia Mobile: +018838 Egypt Website: www.egpandc.com E-mail:protection.control@egpandc.com