SOLO 400/800/1600/ 3200 B

Similar documents
Operating instructions minipuls C200

Operating instructions Bedienungsanleitung Mode d'emploi. minipuls C200.

Operating instructions Bedienungsanleitung Mode d emploi

OPERATING INSTRUCTIONS BRONCOLOR SIROS L

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

Operating instructions broncolor Mobil A2l

Operating instructions EWB 200

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

TritonFlash Instruction Manual Item SK-TRITONFLSH

PIXAPRO LTD. 50 Popes Lane, Oldbury, West Midlands, B69 4PA. INSTRUCTION MANUAL English. Company Registration No

Operating instructions

USER GUIDE. Retail Locations CALUMET ( ) New York, NY W. 19th St

The Safari Portable Flash Generator

P/N Wheeler. user manual

Switching DC Power Supply

Triple Output Power Supply

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Compact LED profile with zoom

XeVision XeRay XV-LX50 HID Searchlight

LyteLaunch Dry - Wet and DMX Models. Operation Manual

Measurements are expressed in millimeters.

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

1000-Watt Energy Center

siros L

KENSUN HID AUTOMOTIVE HEAD LAMP CONVERSION KIT INSTALLATION MANUAL

MANUAL BAT/48342 IMPORTANT NOTE : BEFORE FIRST USE CHARGE THE JUMP STARTER WITH THE SUPPLIED CHARGER FOR AT LEAST 12 HOURS.

Light Source User Guide

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

MULTI FUNCTION POWER PAK PLUS

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

Sinewave Inverters. SWING 150VA and 300VA. User s manual

Battery Power Inverters

Battery Charger. Series EASY Charger. User s manual

LEAD ACID BATTERY CHARGER

Smart Battery Charger

Mania EF1 user manual

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

OPERATION INSTRUCTIONS

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

Power Generator 450 & 800. Instrution manual

welcome Welcome to Speedotron

Ego 01 Ego 02 Ego 03 Logo Projector user manual

Installation Instructions

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Compact Sine Inverter

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

You re never left in the dark.

Installation Instructions

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Rovelight RT 601. Monolight with On Board Power Bowens Mount

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

GSL Electronics Modified Sine Wave Power Inverters

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

LED Twister II. User manual UK Version 1.0

Light Source User Guide

Car Battery Charger Instructions for Use

INSTRUCTION MANUAL FOR PLASMA CUTTER

ATD-5925 RECHARGEABLE 12 VOLT 18 AMP/HOUR JUMP START WITH BUILT-IN 260 PSI AIR COMPRESSOR OWNERS MANUAL

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

Compact Security FloodLight

OPERATIONS MANUAL CR Thermoreactor

User s Manual. Automatic Switch-Mode Battery Charger

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

7 Lighting Technology

Attention please! Bosch rotating beacons

Always remember to put your Series 60 LED on charge after use to prolong the life of the high capacity rechargeable battery.

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

Ultraviolet Fluorescent Lighting Fixtures WF-EM2B, WF-EM4B WF-EM2M, WF-EM4M WF-EM22D, WF-EM4D WF-EM2R, WF-EM4R WF-EMMIM

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Event Spot WW Triac. User Manual. Order codes: LEDJ237 - Black Housing LEDJ237A - White Housing

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

With magnetic fixing With ON/OFF switch

ALU-29CF Portable Light NSN:

HLS Watt Halogen Illuminator Service Manual

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

CH-158 Color Bank 8 USER MANUAL

HILLSTONE DC LOAD BANK

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Welcome to Speedotron. Instruction Manual

UV-cabinet DNA/RNA UVC/T-M-AR

DISCHARGER-ANALYZER BDX USER'S MANUAL

Power Inverter 400 MW Owner s Manual

FiberSource Q150. user manual P/N

1992 Energy Policy Act A Pacific Energy Center Factsheet

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord

MOVING HEAD. User manual CAUTION!

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Ranger RX / Speed / Speed AS & Ranger A Head. Unique super short flash duration with a single, twin electrode flash tube

Fluorescent Ring Light with Dimmer INSTRUCTIONS

Wilo-Control SC-Fire Jockey

User and Fitting Manual June 2008

DC POWER SUPPLY ALIMENTATION C.C.

Transcription:

Operating instructions SOLO 400/800/1600/ 3200 B www.visatec.com 1

Operating instructions V I S A T E C SOLO 400 B / SOLO 800 B / 1600 B / 3200 B Before use Please read all the information contained in these operating instructions carefully. They contain important details on the use, safety and maintenance of the appliance. Keep these operating instructions in a safe place and pass them on to further users if necessary. Observe the safety instructions. Contents page Safety information 2 Controls and displays 3 1. SOLO 400 B / SOLO 800 B / 1600 B / SOLO 3200 B 5 2. Application 5 3. Commissioning 5 4. Flash tube/protecting glass 6 5. Modelling lamp 6 6. Fuse 7 7. Heating/temperature monitor 7 8. Afterglow blockout 7 9. Battery operation 8 10. Mounting 8 11. Changing of reflectors 8 12. Mounting of barn doors 9 13. Umbrella bracket 9 14. Flash release 9 15. Service and repair 9 16. Technical data 10 17. Order numbers for diverse spare parts/accessories 11 2

Safety information Attention: Read before startup - Prior to replacing the fuse, light lamp or flash tube, discharge the unit and disconnect from power. Allow the unit to cool off for 10 minutes before replacing the lamp or flash tube. - Only those types of fuses indicated on the fuse label may be used. This is particularly important for fusing the halogen lamp which may burst if the wrong fuse is used. - Only sand-filled fuses may be used. Sand-filled fuses can be identified by the opaque body of the fuse. - The devices are designed for use in dry rooms. Protect them against splash water and against excessive exposure to dust. - The devices are not suitable for use in an environment with risks of explosion. - The accessories mounted to the unit my heat up to high temperatures under specific conditions. Handle with care! - To protect against the effects of radiated heat, the unit must not be pointed at flammable surfaces from less than 1 meter away. - Do not block the cooling louvers on the unit. - Flash light contains, similar to sunlight, a specific portion of UV light. The undesirable side effects on skin and eyes are considerably reduced by using flash tubes with UV coating. Without these or other protective filters, use extreme care when shooting. - Even when disconnected from power, dangerous voltages may remain within the interior of the device. For this reason, devices should be opened by our VISATEC repair service. - For safety reasons, operate a lamp (resp. a unit) only with the mounted protecting glass. The protecting glass should not be damaged, to guarantee a perfect functioning of the unit. - The unit may only be used for professional photography and must only be operated by trained personnel. 3

Controls and displays 1. Flash release key 2. Jack for synchronous cable 3. Flash ready control lamp 4. Connection socket for mains cable 5. Fuse 6. Switch for modelling light (proportional/full) 7. Switch for modelling light (on/off) 8. Main switch (on/off) 9. Slave cell (on/off) 10. Rotary switch for power control 11. Switch for dim function (flash release control) 4

Front panel to SOLO 5

1. SOLO 400 B / SOLO 800 B / 1600 B / SOLO 3200 B We are delighted that you have chosen the high quality product VISATEC SOLO. With proper care it will render you many years of good service. 2. Application This mains supplied studio flash unit is designed for professional photography only. In countries with earthed mains systems, use a threewire extension cable whenever needed. 3. Commssioning 3.1 Remove grey plastic hood by rotating. Insert desired reflector and protecting glass and rotate in any direction. 3.2 Please check that the mains supply corresponds to the information on the label of the unit. Connect unit to earthed power. 3.3 Switch on main switch (8) and modelling light (7). 3.4 The modelling light can be switched off or on during charging (dim function) by pushing in switch (11) with a small screwdriver. This option allows the photographer to confirm visually that all the VISATEC SOLO units have fired. 3.5 Set intended flash output via control knob (10). 3.6 Green control lamp (3) will illuminate: this is how the units show that it is ready 3.7 Release test flash by pressing key (1). 3.8 Switch photocell (9) on or off, depending on the shot-situation. 3.9 If needed, plug in synchronous cable (2). 6

4. Flash tube/protecting glass The flash tube or the protecting glass is coated to achieve an optimal colour temperature. For your security, only original flash tubes should be used. For safety reasons, never operate a unit without the protecting glass in place. If you need the compact unit SOLO 800 B for longer flash sequences, we propose the use of the flash tube to SOLO 1600 B. 4.1 Changing of the flash tube: 1. To replace it, fire a flash, disconnect unit from power, and allow to discharge and cool off for ten minutes (to ensure that the flash capacitor has discharged). 2. Remove the protecting glass. 3. First pull out the triggering cable and then the flash tube (do not touch with bare hands). 4. Insert the new flash tube. 5. Insert the triggering cable. 6. Replace the protecting glass. 7. Plug in the unit, now it is ready for use. 5. Modelling light The units are equipped with a very bright 150W halogen modelling light. The halogen lamp can be plugged in, when exchanging, beware of touching the lamp with bare hands. Please note, that you must pull out the flash tube before exchanging the modelling lamp. In order to meet the european security standard, the modelling lights which are offered by the manufacturer must be used. 7

6. Fuse The fuse (5) is located on the rear of the unit. Sand-filled fuses with a value 3.15 AF may only be used (sand-filled fuses can be identified by their opaque fuse container). Using an incorrect fuse is dangerous: it may cause the halogen lamp to burst. The correct fuse is therefore included with each original VISATEC replacement lamp. 7. Heating/temperature monitor In the proximity of the halogen lamp, the unit, depending on adapters used, can acquire high temperatures. For this reason, we recommend touching the unit on the handle behind or on the stand adapter only. Due to the intense heat radiation when a modelling light is in operation, keep the unit at a minimum distance of 1 m from flammable surfaces. The units SOLO 800 B / 1600 B / 3200 B contain a temperature sensor which protects the electronic circuitry from overload during long flash sequences. If the safety system is activated, the modelling light goes out and charging is blocked. The ready indicator light changes to red until the unit has cooled off. The fan will continue to operate to promote faster cooling. Using the SOLO 400 B, only a maximum of 120 flashes are possible within 1 hour. 8. Afterglow blockout The units SOLO 800 B / 1600 B / 3200 B are equipped with an automatic afterglow blockout. If the flash tube begins to exhibit afterglow (at the end of its service life, for example), this blockout blocks further charging to prevent any additional damage. The ready indicator light also glows continuously red to indicate this condition. To cancel the blockout, switch the unit off and then on again. 8

9. Battery operation If no mains power is available, use the 12-volt car battery converter to load (only for 220V units). The modelling light cannot be used on this mode (excessive load on battery). - Switch off modelling light and pull it out. - Connect converter to the 12-volt car battery with the + and - connector clamps. - Connect unit to converter; Switch on converter and unit. - After flash work, switch off converter during pauses. Charge battery if needed by allowing the car engine to run. - One SOLO compact unit can be connected to the converter (220V). A fully charged battery results in the following charging times, respectively flash discharges: SOLO 400 B 120 flashes at 130 J 3.5s SOLO 800 B 100 flashes at 300 J 5s SOLO 1600 B 100 flashes at 600 J 7s SOLO 3200 B 50 flashes at 1200J 12s 10. Mounting The stand adapter is located below the housing. The adapter will accept standard broncolor bolts and Manfrotto pins. Make sure the lamp is firmly attached to the stand before operating. The click-stops of the locking handle can be adjusted by pulling it out. A locking pin is screwed into the lower part of the stand adapter so it can be hung from a broncolor bolt; this is not required for stand mounting, and must be removed. A safety cable must be installed whenever the lamp head is suspended. 11. Changing of reflectors Reflectors and accessories are provided with an adapter which is to be fixed to the bayonet mounting with a slight turn. 9

12. Mounting of barn doors The barn doors are inserted on the mounting supports of the reflector. 13. Umbrella bracket The umbrella reflector (art. no. 53.457.00) is used in conjunction with umbrella diffusers and reflectors. The umbrella handle is inserted into the special holder in the stand adapter. 14. Flash release The release is possible via sync cable, photocell or with manual release button. The units are fitted with a synchronous circuit with low working voltage to protect the camera contact. This synchronous contact may not be switched parallel with outside brands since the latter work with high synchronous voltage. When releasing by the photocell make sure that the receiver cell of the unit is not blocked by obstacles. As the photocell is also sensitive in the infrared range, the unit can be triggered, wirelessly, via a small flash unit on the camera fitted with an IRpermeable filter. 15. Service/repair Your VISATEC compact unit is a precision device which will work for many years without malfunctions if you take proper care of it. If malfunctions do arise, please do not attempt to open the unit so as to repair it yourself. Even when the unit is shut off, dangerous voltages may remain within the interior of the device. Leave service and repairs to our VISATEC repair service. 10

16. Technical data F-stop at 1 m (ISO 100, standard reflector) SOLO 400 B SOLO 800 B SOLO 1600 B SOLO 3200 B 32 45 64 90 Flash duration (t 0.5) 1/1200s 1/800s 1/600s 1/900s Charging time (to 100% of selected energy) 0.25s-1.1s 0.6-1.4s 0.7-1.9s 0.6-2.2s Ready indicator Visual at 100% of selected energy Control range of Over 3 stops Over 3 stops Over 3 stops Over 4 stops flash energy Modelling light Halogen 150W Halogen 150W Halogen 150W Halogen 150W Flash release Sync cable, infrared-sensitive* photocell (can be switched off), manual test button Reflector mount Patented interlocking bayonet Stabilized flash voltage +/- 1% +/- 1% +/- 1% +/- 1% Power requirements 200-240V, 50 Hz:6A 110-120V, 60 Hz:6A 110-120V, 60 Hz: 10A 220-240V, 50Hz: 6A 100V, 50 Hz: 10A Norms EC standards, 73/23, UL 122 200-240 V, 50 Hz: 10A 110-120 V, 60 Hz: 10A 100 V, 50 Hz: 16A 200-240 V, 50 Hz: 10A 110-120 V, 60 Hz: 16A 100 V, 50 Hz: 16A Dimensions 120x190x340 mm 120x195x410 mm 120x195x410 mm 120x195x495 mm (not including handle) Weight 2,3 kg / 5,1 lbs. 2,4 kg 2,6 kg 4,3 kg * The infrared-sensitive photocell of the SOLO units reacts to a small amateur flash with a dark red filter placed in front of it. Subject to change in the interest of technical development. 10

17. Order numbers for diverse spare parts/accessories Flash tube, coated for SOLO 800 B art.no. 54.300.00 Flash tube, coated for SOLO 1600 B art. no. 54.301.00 Flash tube, clear for SOLO 3200 B art. no. 54.302.00 Flash tube, coated for SOLO 400 B art. no. 54.303.00 Halogen modelling lamp (150W/120V) art. no. 54.251.XX Halogen modelling lamp (150W/230V) art. no. 54.252.XX Protecting glass, clear art. no. 54.400.59 Protecting glass coated for SOLO 3200 B art. no. 54.401.00 Fuse 3.15 AF art. no. 37137.00 Protection cap for transport, grey art. no. Z6098.00 Mains cable CH 200-240V art. no. 39084.00 Mains cable USA 100-120V art. no. 39085.00 Mains cable Europe 200-240V art. no. 39086.00 12 V battery converter 220V art. no. 36.450.10 Sync cable art. no. 54.104.00 11

Printed in Switzerland 11.03 Bron Elektronik AG CH-4123 Allschwil Schweiz (Switzerland) 12