Operating instructions minipuls C200

Similar documents
SOLO 400/800/1600/ 3200 B

Operating instructions Bedienungsanleitung Mode d'emploi. minipuls C200.

OPERATING INSTRUCTIONS BRONCOLOR SIROS L

Operating instructions Bedienungsanleitung Mode d emploi

Operating instructions broncolor Mobil A2l

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

USER GUIDE. Retail Locations CALUMET ( ) New York, NY W. 19th St

TritonFlash Instruction Manual Item SK-TRITONFLSH

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

PIXAPRO LTD. 50 Popes Lane, Oldbury, West Midlands, B69 4PA. INSTRUCTION MANUAL English. Company Registration No

P/N Wheeler. user manual

The Safari Portable Flash Generator

Operating instructions EWB 200

Switching DC Power Supply

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Light Source User Guide

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

Rovelight RT 601. Monolight with On Board Power Bowens Mount

LyteLaunch Dry - Wet and DMX Models. Operation Manual

XeVision XeRay XV-LX50 HID Searchlight

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

Measurements are expressed in millimeters.

ECO Spot 2500 User Manual

ECO Spot 2500 User Manual

Mania EF1 user manual

Compact LED profile with zoom

siros L

1992 Energy Policy Act A Pacific Energy Center Factsheet

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

Light Source User Guide

FiberSource Q150. user manual P/N

Ego 01 Ego 02 Ego 03 Logo Projector user manual

1000-Watt Energy Center

Triple Output Power Supply

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord

Battery Power Inverters

KENSUN HID AUTOMOTIVE HEAD LAMP CONVERSION KIT INSTALLATION MANUAL

DH-2000 Deuterium-Halogen Light Source Installation and Operation Manual

LEAD ACID BATTERY CHARGER

Event Spot WW Triac. User Manual. Order codes: LEDJ237 - Black Housing LEDJ237A - White Housing

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Snapshot LX10 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

OPERATION INSTRUCTIONS

Power Generator 450 & 800. Instrution manual

OPERATIONS MANUAL CR Thermoreactor

7 Lighting Technology

GSL Electronics Modified Sine Wave Power Inverters

ATD-5925 RECHARGEABLE 12 VOLT 18 AMP/HOUR JUMP START WITH BUILT-IN 260 PSI AIR COMPRESSOR OWNERS MANUAL

58kHz AM Deactivator DB104 Instruction Manual V1.0

Operating Instruction Manual of Energy Management System EBL 208, Art.-No Seite 1 / 7

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

Always remember to put your Series 60 LED on charge after use to prolong the life of the high capacity rechargeable battery.

Smart Battery Charger

BRAVER UPS. (Uninterruptible Power System) User s Manual

INSTRUCTION MANUAL FOR PLASMA CUTTER

User s Manual. Automatic Switch-Mode Battery Charger

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

ALU-29CF Portable Light NSN:

Mania DC3 user manual

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Q-Series Ultraviolet Lamps OPERATOR S MANUAL

MULTI FUNCTION POWER PAK PLUS

Item No User Manual. All-in-One Solar Courtyard / Street LED Light

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

Lambda HPX-L5. High-Power LED Light Source System (Air-Cooled with Liquid Light Guide) Operation Manual. Rev (( )

Wilo-Control SC-Fire Jockey

6000DC CONTAINS TRANSMITTER AND RECEIVER BOX ONLY

1. Before You Begin What Is Included... 3 Unpacking Instructions Claims Product at a Glance... 3 Safety Instructions...

UV-cabinet DNA/RNA UVC/T-M-AR

MOVING HEAD. User manual CAUTION!

OPERATION MANUAL MODELS TWE-250 TWE-321 TWE-375 TRU WELD EQUIPMENT COMPANY 6400 N. HONEYTOWN ROAD SMITHVILLE, OHIO (330)

MANUAL BAT/48342 IMPORTANT NOTE : BEFORE FIRST USE CHARGE THE JUMP STARTER WITH THE SUPPLIED CHARGER FOR AT LEAST 12 HOURS.

Snapshot. Hurricane 1300 USER MANUAL F-1300

Power Inverter 400 MW Owner s Manual

Fluorescent Ring Light with Dimmer INSTRUCTIONS

Verti Blast. User Manual. Order code: EQLED355

Welcome to Speedotron. Instruction Manual

User Guide for Logo Projector

Compact Security FloodLight

Originalbedienungsanleitung/Ersatzteilliste 5. Original operating manual/spare parts list 11

Hartenberger Underwater Hand Lamp

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

Smart Sensor Pro+ User Guide

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

welcome Welcome to Speedotron

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Operating instructions

156W Explosion Proof Portable LED 360 Degree Flood Low Profile Light System - 2ft - Tank Cleaning

Abbeon Cal, Inc. Model BD-50E HIGH FREQUENCY GENERATOR OPERATING MANUAL

Electromotoric Actuators

Compact Sine Inverter

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

TECHNICAL MANUAL. FOR BLAST 2 (Bright Light Aiming System Tactical 2) For Rifles and Pistols Equipped with MIL-SPEC-1913 and Picatinny Rails

6-2 Interior equipment

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

TABLE OF CONTENTS 1. BEFORE YOU BEGIN...

Transcription:

Operating instructions minipuls C200 www.broncolor.com

Operating instructions b r o n c o l o r M i n i p u l s C200 Before use Please read all the information contained in these operating instructions carefully. They contain important details on the use, safety and maintenance of the appliance. Keep these operating instructions in a safe place and pass them on to further users if necessary. Observe the safety instructions. Contents page Safety information 3 Controls and displays 4 Front panel for Minipuls C200 5 1. Minipuls C200 6 2. Application 6 3. Commissioning 6 4. Flash tube 7 5. Protecting glass 7 6. Modelling light 7 7. Fuse 7 8. Heating/temperature monitor 7 9. Afterglow block 8 10. Mounting 8 11. Umbrella bracket 8 12. Flash release 8 13. Accessories 9 14. Service and repair 9 15. Technical data 10 16. Order numbers for diverse spare parts/accessories 10 1

2

Safety information Attention: Read before start up - Prior to replacing the fuse, light bulb or flash tube, discharge the unit and disconnect from power. Allow the unit to cool off for 10 minutes before replacing the bulb or flash tube. - Only those types of fuses indicated on the fuse label may be used. This is particularly important for fusing the halogen lamp which may burst if the wrong fuse is used. - Only sand-filled fuses may be used. Sand-filled fuses can be identified by the opaque body of the fuse. - The devices are designed for use in dry rooms. Protect them against splash water and against excessive exposure to dust. - The devices are not suitable for use in an explosions-hazard environment. - The accessories mounted to the unit may heat up to high temperatures under specific conditions. Handle with care! - To protect against the effects of radiated heat, the unit must not be pointed at flammable surfaces from less than 1 meter away. - Do not block the cooling louvers on the unit. - Flash light contains, similar to sunlight, a specific portion of UV light. The undesirable side effects on skin and eyes are considerably reduced by using flash tubes with UV coating. Without these or other protective filters, use extreme care when shooting. - Even when disconnected from power, dangerous voltages may remain within the interior of the device. For this reason, devices should only be opened by our broncolor repair service. - For safety reasons, never operate a unit without the protecting glass in place. 3

Controls and displays 1. Flash release key 2. Jack for synchronous cable 3. Flash ready control lamp 4. Connection socket for mains cable 5. Fuse 6. Switch for modelling light (proportional/full) 7. Switch for modelling light (on/off) 8. Main switch (on/off) 9. Slave cell (on/off) 10. Infrared receiver (on/off) 11. Rotary switch for power control 12. Switch for dim function (flash release control) 13. Reflector release 4

Front panel for Minipuls C200 5

1. Minipuls C200 We are delighted that you have chosen the high quality product broncolor Minipuls C200. With proper care it will render you many years of good service. 2. Application This mains supplied studio flash unit is designed for professional photography only. In countries with earthed mains systems, use a threewire extension cable. 3. Commissioning 3.1 Remove grey plastic hood by rotating. Insert the flash tube in accordance to point 4 and plug in the modelling lamp. Press desired reflector and protecting glass into the mounting and rotate in any direction. 3.2 Please check that the mains supply corresponds to the information on the label of the unit. Connect unit to earthed power. 3.3 Switch on main switch (8) and modelling light (7). 3.4 The modelling light can be switched off or on during charging (dim function) by pushing in switch (12) with a small screwdriver. This option allows the photographer to confirm visually that all the Minipuls C200 units have fired. 3.5 Set desired flash output via control knob (11). 3.6 Green control lamp (3) will illuminate: this is how the unit shows that it is ready 3.7 Release test flash by pressing key (1). 3.8 Switch photocell (9) or infrared receiver (10) on or off. 3.9 If needed, plug in synchronous cable (2). 6

4. Flash tube The flash tube is pluggable. To replace it, fire a flash, disconnect unit from power, and allow to discharge and cool off for ten minutes. Then press the spring radially inward and carefully remove or plug in the flash tube. The spring acts as the electrical contact and also prevents the tube from falling out. For Minipuls C200 following 1500 J flash tubes are available. coating for 5500 K art. no. 34.310.55 5. Protecting glass For safety reasons, never operate a unit without the protecting glass in place. - Clear protecting glass for Minipuls C200 art. no. 34.336.59 6. Modelling light The unit is equipped with a very bright halogen modelling light. The maximum tolerated modelling light output supplies: Minipuls C200 650 W 220-240 V, 300 W 110-120 V In order to meet the European security standard, the modelling lamps which are offered by the manufacturer must be used. 7. Fuse The fuse (5) is located on the rear of the unit. Sand-filled fuses with a value 3.15 AF may only be used (sand-filled fuses can be identified by their opaque fuse container). Using an incorrect fuse is dangerous: it may cause the halogen lamp to burst. The correct fuse is therefore included with each original broncolor replacement lamp. 8. Heating/temperature monitor In the proximity of the halogen lamp, the unit, depending on adapters used, can acquire high temperatures. For this reason, we recommend touching the unit on the handle behind or on the stand adapter only. Due to the intense heat radiation when a modelling light is in operation, keep the unit at a minimum distance of 1 m from flammable surfaces. 7

The unit contains a temperature sensor which protects the electronic circuitry from overload during long flash sequences. If the safety system is activated, the modelling light goes out and charging is blocked. The ready indicator light changes to red until the unit has cooled off. The fan will continue to operate to promote faster cooling. 9. Afterglow block The unit is equipped with an automatic afterglow block. If the flash tube begins to exhibit afterglow (at the end of its service life, for example), this block stops further charging to prevent any additional damage. The ready indicator light also glows continuously red to indicate this condition. To cancel the block, switch the unit off and then on again. 10. Mounting The stand adapter is located below the housing. The adapter will accept standard broncolor bolts and Manfrotto pins. Make sure the lamp is firmly attached to the stand before operating. The click-stops of the locking handle can be adjusted by pulling it out. The enclosed locking pin has to be screwed into the lower part of the stand adapter so it can be hung from a broncolor bolt; this is not required for stand mounting. A safety cable must be installed whenever the lamphead is suspended. 11. Umbrella bracket The umbrella reflector (art. no. 33.496.00) is used in conjunction with umbrella diffusers and reflectors. The umbrella handle is inserted into the special holder in the stand adapter. 12. Flash release The release is possible via sync cable, infrared, photocell or with manual trigger button. The units are fitted with a synchronous circuit with low working voltage to protect the camera contact. This synchronous contact may not be switched parallel with outside brands since the latter work with high synchronous voltage. 8

The infrared receiver integrated in the unit is used for a wireless release by the following units - IRX 2 transmitter } Available as from - FCM 2 lightmeter and contrast photometer } shipping date - FCC flash colormeter chronoscope } 1/1995 When in use, make sure that the receiver cell of the unit is not blocked by obstacles. 13. Accessories The Pulso bayonet system allows you to use the full line of broncolor reflectors. For a complete summary, please consult the broncolor system catalogue, "Be Creative with Light. And with System." 14. Service and repair Your broncolor compact unit is a precision device which will work for many years without malfunctions if you take proper care of it. If malfunctions do arise, please do not attempt to open the unit to repair it yourself. Even when the unit is shut off, dangerous voltages may remain within the interior of the device. Leave service and repairs to our broncolor repair service. 9

15. Technical data Minipuls C200 Flash energy 1500 J F-stop at distance of 2 m, 64 100 ISO, reflector P70 Flash duration t 0.1 t 0.5 1/250 s 1/1000 s Charging time (for 100 % 0.6-2.4 s of selected energy) Ready display optical Control range 4 f-stops Modelling light halogen max. 650 W (off, prop, dim, full) Flash release wireless via infrared transmitter IRX 2, FCM 2*, FCC*, photocell, sync cable, manual release button Reflector mounting Pulso bayonet Stabilized flash voltage +/- 1 % Power requirements 220-240 V, 50 Hz, 10 A or 110-120 V, 60 Hz, 16 A Interference suppressor SEV, VDE Dimensions 120 x 195 x 495 (mm) Weight 4.5 kg * From year of production 1995, serial number begins with C (=compatible with Minipuls C200). Subject to change in the interest of technical development. 16. Order numbers for diverse spare parts/accessories flash tube 5500 K for Minipuls C200 art. no. 34.310.55 halogen modelling light (650 W / 240 V) art. no. 34.226.XX halogen modelling light (300 W / 120 V) art. no. 34.225.XX halogen modelling light "longlife" (300 W / 120 V) art. no. 34.232.XX protecting glass, clear 5900 K art. no. 34.336.59 protecting glass, mat 5900 K art. no. 34.337.59 protecting glass 5500 K art. no. 34.336.55 protecting glass, mat 5500 K art. no. 34.337.55 fuse 3.15 AF art. no. 37137.00 transport protecting cap, grey art. no. Z3620.00 mains cable Europe 200-240 V art. no. 39086.00 mains cable CH 200-240 V art. no. 39084.00 mains cable USA 100-120 V art. no. 39085.00 10