A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories

Similar documents
A-4000 Series Oil Removal and Pressure Reducing Stations & Air Compressor Accessories

ZTF. Compressed Air Filters scfm INNOVATIVE COMPRESSED AIR SOLUTIONS FILTER ASSEMBLIES ELEMENT OPTIONS SPECIFICATIONS ACCESSORIES

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

V-9502 Series Pneumatic Valve Actuator Positioners

M Ball Valve Linkage Kit

M x Cast Iron Flanged Valve Linkage Kit for Mounting a Single M9000 Series Electric Actuator

Installation Instructions

M x Series Cast Iron Flanged Valve Linkage Kit for Tandem Mounting of M9000 Series Electric Actuators

Part III: Maintenance

74 Series Combination Filter/Regulator and Lubricator Unit, featuring an in-line shut-off valve, and Quikclamp system.

AIR PREPARATION PRODUCTS. Table of Contents

PP1 Series Piping Packages for VG1000 Series Ball Valves

Filters, regulators, and lubricators

P70 Series MICRO-SET TM Pressure Controls for Refrigeration and Air Conditioning, 4-Wire, 2-Circuit Contact Block

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

Installation Instructions. Applications. Installation. Part No , Rev. Issued May 9, 2011

This valve is designed to modulate flow of water or glycol to a water cooled condenser on a refrigeration system. ice machines. Pressure Element Style

105 Commerce Way Westminster, SC Tel: (864) Fax: (864)

M Valve Actuator Weather Shield Kit

RD-2000 Round Control Dampers

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

V46 Series Pressure-Actuated Water-Regulating Valves

Doosan XHP1170FCAT Bid Specifications

BD-1600 Balancing/Zone Control Damper

C-5230 Pneumatic Signal Limiter

M x Series Cast Iron Flanged Valve Linkage Kit for M9000 Series Electric Actuators

M Remote Mounting Kit

M x Series Valve Linkage Kits

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

Manual Flushing. I nspection and Service

3000 Series filters 3/4" and 1" Ports

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

Models & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø

Model Model Model

Your Plant Deserves Pure-Aire!

S-2300 Pneumatic Selector Switch

M x Series Valve Linkage Kits

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR

SUB-LINE FILTERS CONTENTS

Temperature Sensor Series

INSTRUCTION AND MAINTENANCE MANUAL GFH45 PRESSURE REGULATOR

AV-8020 Series Floating Control Actuated Valve

P70, P72 and P170 Series Controls for High Pressure Applications

D-3240 Series Pneumatic Piston Actuators

Model Series 66 Amplifying and Reducing Relays

ID-141x 12-Gauge Hat Channel Industrial Damper

Installation. Installation. 12. System Diagram... 10

Baumann Mikroseal Control Valve

M9000-3xx Series Weather Shield Enclosures

T PI Receiver-Controller

ARO-FLO SERIES FILTERS, REGULATORS AND LUBRICATORS

MODEL 73N BUILT-IN VALVE POSITIONER

Doosan XHP1170WCAT Bid Specifications

Pressure Relief Valve Maintenance Manual

Filters, Gauges, Regulators

F61 Series Standard Flow Switches

MIS SERIES. Mist Eliminator. Installed differential pressure gauge and optional zero air-loss drain valve. Air or Water Cooled Aftercooler

FRP SystemOne GELCOATER OPERATION MANUAL. MAGNUM VENUS PRODUCTS Operation Manual. Part No. M Revision

M x Series Valve Linkage Kits

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve

Cash Valve B SERIES PRESSURE REGULATORS. ISSUED - JANUARY 1999 CAVMC-0509-US-0208 ISO 9001 Certified

Pressure Sensor No Series

TK-6024, TK-6124, TK-8024, TK-8124

60 SCFM Model # A B C D 3C-060-M04-P, Manual Drain C-060-M04-F, Float Drain C-060-M04-Fi, Float Drain w/indicator

Flow Meters. Installation, Operation & Maintenance Manual.

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER FILTER DRYER

Bettis M11 Manual Hydraulic Override System Operating Instructions for HD, T, and G Series Pneumatic and Hydraulic Actuators

Logo/Company Name 4 w x.75 h. Assembly Instructions. 1) Remove base, back/back bar, pneumatic cylinder, casters/glides, and seat from box.

Pilot-Operated Regulators

D-4070 Two Stage Pneumatic Actuator

F200 Series. Compressed Air and Gas Filters FEATURES. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

Vision Ped Plus. Operators Guide. Studio Pedestal. Vinten Camera Control Solutions

P70, P72, and P170 Controls for Low Pressure Applications

VA-7450 Series. Electric Valve Actuators

Baumann Sanitary Angle Control Valve

INSTRUCTION MANUAL FLUID POWER DIVISION Miniature Series. F300, R160, R260, R2424 & L180 Mini Particulate Filter Regulator Lubricator...

Y690A Series Pressure Reducing Regulators

PC-125x Counter-Balanced Backdraft Damper

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

NAVAL INSTALLATION INSTRUCTIONS PISTON TYPE FLUSHOMETER FOR EXPOSED CLOSET AND URINAL INSTALLATIONS LIMITED WARRANTY

B14 AAA FINE FINISH SERIES PUMP OUTFIT

P200 Pressure Regulator

Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations

F200 Series. Compressed Air and Gas Filters. Heavy duty cast aluminum housings. Maximum working pressure 250 PSIG. Nine filtration grades

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

VG7000 Series Bronze Control Valves

DO NOT INSTALL, OPERATE, OR MAINTAIN AN ATI PRODUCT UNLESS TRAINED AND QUALIFIED IN PRODUCT AND ACCESSORY INSTALLATION, OPERATION AND MAINTENANCE.

29 Series OEM Style Bronze Safety Valves for Steam, Air and Non-Hazardous Gas

Air Line Modulars Each component is engineered to connect easily modular FRL assemblies manual shut off

SPECIFICATIONS TEST AND ADJUSTMENT SPECIFICATIONS SPECIFICATIONS ENGINE FD620D, K SERIES

Parker Global Air Preparation System

COMPRESSED AIR FILTERS

F261 Series Fluid Flow Switches

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

KIT INSTALLATION INSTRUCTION

Modulating Water Valves and Bulb Wells

Logo/Company Name 4 w x.75 h. Assembly Instructions. 1) Remove base, back/back bar, pneumatic cylinder, casters/glides, and seat from box.

Transcription:

A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories Installation Applications The A-4000 Series Oil Removal and Pressure-Reducing Stations (see Figure 1, Figure 2, Figure 3, and Figure 4) are available in single or dual PRV models in 10 or 20 scfm (4.7 or 9.4 l/s) maximum flow capacities. In addition, each unit features a four-way bypass valve, coalescing and activated charcoal oil removing filters, and is completely piped with copper tubing, which reduces friction, allows higher flow rates, and meets fire codes in mechanical equipment rooms. The filter combination removes oil aerosols and vapors to provide clean, oil-free air for pneumatic control systems. All models provide maximum performance for a period of 1 year, at which time the coalescing and activated charcoal filter elements need to be replaced. Gauges are provided to monitor system operations and performance. All models can provide filtered, high-pressure air to remote PRV stations. All models have a maximum input pressure rating of 150 psig (1,050 kpa) and an upper temperature limit of 125 F (52 C). Part No. 64-257-14, Rev. C Issued September 27, 2013 Supersedes September, 2007 Refer to the QuickLIT website for the most up-to-date version of this document. Figure 2: A-4000-140, 10 scfm, Dual PRV Station Figure 3: A-4000-141, 20 scfm, Single PRV Station Figure 1: A-4000-139, 10 scfm, Single PRV Station (Shown with Optional Oil Reservoir) Figure 4: A-4000-142, 20 scfm, Dual PRV Station (Shown with Optional Oil Reservoir) A-4000 Series Oil Removal and Pressure-Reducing Stations and Air Compressor Accessories Installation 1

Single PRV models are factory-set for approximately 20 psig (140 kpa), and dual PRV models are factory-set for approximately 15 and 20 psig (105 and 140 kpa). Dual 10 scfm units have a maximum of 1 psi (7 kpa) pressure drop with a 10 scfm flow from the PRVs through the three-way air valve; dual 20 scfm units have a maximum of 2 psi (14 kpa) pressure drop. The three-way air valve is equipped with a 1/2 in. O.D. compression fitting to furnish the dual supply air to the system. A 1/2 in. connection is furnished to provide a constant 20 psig (140 kpa) supply to local control panels, and a 3/8 in. connection is furnished to provide filtered high-pressure air to remote PRV stations. Table 1: Models Flow Consumption Compressor Horsepower (50% Running Time) Note: All A-4000 Series Oil Removal and Pressure-Reducing Stations are shipped from the factory with the activated charcoal filter packaged separately in the carton. The filter must be reinstalled by screwing it onto the threaded pipe of the filter head. Tighten the filter to the point where the white label faces the front of the unit. IMPORTANT: System air flow consumption must not increase beyond the maximum flow listed. Overconsumption forces oil through the coalescing filter, saturating the activated charcoal filter before its required replacement time. PRVs Code Number Up to a Maximum of 10 scfm (4.7 l/s) Johnson Controls 7-1/2 hp and Under Single A-4000-139 Dual A-4000-140 10 to 20 scfm Maximum (4.7 to 9.4 l/s) Other Manufacturers 7-1/2 hp and Over Single A-4000-141 Dual A-4000-142 Table 2: Repair Parts Description Code Number Charcoal Filter Elements 10 scfm (4.7 l/s) A-4000-632 20 scfm (9.4 l/s) A-4000-633 Coalescing Filter Elements 10 scfm (4.7 l/s) A-4110-604 20 scfm (9.4 l/s) A-4000-604 3/8 in. Pressure Regulator with Bracket, Gage, and Safety Relief Valve A-4000-138 Four-Way Bypass Valve with 3/8 in. Compression Fittings A-4110-601 2

Figure 5: Flow Path with Bypass Valve in Bypass Position (Applies to all Models) Figure 6: Flow Path through Three-Way Air Valve on Dual Oil Removal and Pressure-Reducing Stations (Shown with Optional Oil Reservoir), in./mm 3

Remote-Mounted 3/8 in. Pressure-Reducing Station The A-4000-138 Remote-Mounted 3/8 in. Pressure-Reducing Station (see Figure 7) comes completely assembled with a wall mounting bracket, 0 to 30 psig gauge, safety relief valve, and 3/8 in. O.D. compression elbow fittings on the high- and low-pressure sides. The desired output pressure can be easily adjusted between 0 and 30 psig using the black knob. The factory-set safety relief valve relieves overpressures exceeding 25 psig (175 kpa). Pressure adjustments up to 50 psig (350 kpa) can be made; however, the 0 to 30 psig gauge must be replaced with one having a higher scale, and the safety relief valve must be readjusted to the required higher value. Designed to handle input pressures up to 300 psig (2,100 kpa) at air flows exceeding 20 scfm (9.4 l/s), this pressure-reducing station regulates an output pressure within a 0.2 psi (1.4 kpa) variation with a 20 psi (140 kpa) variation in input pressure. Figure 7: A-4000-138 Remote-Mounted 3/8 in. Pressure-Reducing Station Figure 8: A-4000-138, in./mm Table 3: Repair Parts Description Code Number 1/4 in. NPT, 25 psig Safety Relief Valve (Not ASME Coded) A-4000-144 Replacement Bracket A-4000-143 Figure 9: A-4000-143 Mounting Bracket, in./mm 4

Oil Reservoir The A-4000-145 Oil Reservoir (see Figure 10) provides a means of identifying excess oil pumping (compressor maintenance) as well as water entrainment (air dryer maintenance). If either occurs, replacement of the oil removal elements is required. The oil reservoir also provides a means of collecting the coalesced oil for proper disposal. Oil Removal Filters The combination of coalescing and activated charcoal filters (see Figure 11) in series removes both oil aerosols and vapors to provide clean, oil-free air for pneumatic control systems. These filters have a maximum input pressure rating of 150 psig (1,050 kpa) and an upper temperature limit of 125 F (52 C). Note: The air supply to this filter combination must be from a properly broken-in air compressor producing less than 6 ppm aerosol oil (as measured by a Johnson Controls A-4000-120 Oil Indicator on the compressor tank outlet) and must also pass through a properly operating air dryer. Figure 10: A-4000-145 Oil Reservoir and Bracket Assembly Coalescing Filter Charcoal Filter Figure 11: Oil Removal Filters Table 4: Models Description Efficiency Rating Code Number Coalescing 10 scfm (4.7 l/s) 99.999+% Efficient for Particles 0.025 microns in Size and A-4000-1048 20 scfm (9.4 l/s) Larger A-4000-1049 40 scfm (18.9 l/s) A-4000-6001 Carbon 10 scfm (4.7 l/s) 100% Efficient for Particles as Small as 0.025 microns in A-4000-147 20 scfm (9.4 l/s) Size A-4000-146 5

Table 5: Repair Parts Description Code Number Coalescing Filter Elements 10 scfm (4.7 l/s) A-4110-604 20 scfm (9.4 l/s) A-4000-604 40 scfm (18.9 l/s) A-4000-605 Charcoal Filter Elements 10 scfm (4.7 l/s) A-4000-632 20 scfm (9.4 l/s) A-4000-633 Filter Auto-Drain Kit (All Coalescing Filters) A-4000-6010 Servicing Procedure for Coalescing Filters All coalescing filters are equipped with an automatic drain from which accumulations of entrapped liquids are automatically blown out. The filter element should be replaced when the leaving air pressure gauge (mounted on the PRV station charcoal filter head) indicates less than 50 psig (350 kpa) the differential pressure between the leaving and input gauges is 15 psi (105 kpa) or more, or after one year of service whichever occurs first. To replace the filter element, see Figure 14 and proceed as follows: 1. Turn the air supply OFF. 2. Depress the lever on the filter bowl clamp and turn 1/8 of a revolution. Drop the clamp, bowl guard, and bowl to expose the filter element which needs to be replaced. 3. Remove the old filter element by turning it counterclockwise. 4. Clean the small screen around the drain seat of the automatic drain seat of the automatic drain valve by turning the filter bowl upside down and tapping it lightly on a table top. 5. Clean the bowl and drain valve assembly using household detergent or any solvent that is not harmful to polycarbonate. 6. Install the new filter element and bowl O-ring, then reinstall the bowl and guard. A-4110-604 (10 scfm) A-4000-604 (20 scfm) A-4000-605 (40 scfm) Figure 12: Coalescing Filter Elements A-4000-633 (20 scfm) A-4000-632 (10 scfm) Figure 13: Charcoal Filter Elements Figure 14: Coalescing Filter Disassembly 6

Servicing Procedure for Activated Charcoal Filter Refer to the white service label on the activated charcoal filter element for proper replacement procedure. Note: After the activated charcoal filter element has been replaced, apply the white service label included and record the next replacement date (month and year). A-4000-6010 Filter Auto-Drain Replacement Release the pressure in the system and remove the bowl guard and the plastic bowl. Insert a 7/64 in. Allen wrench up through the bottom of the external 1/2 in. hex brass nut to prevent the float assembly from turning when loosening the 1/2 in. hex brass nut to remove the old auto-drain assembly. Install the replacement auto-drain assembly. Turn the hex brass nut finger-tight while restraining the float assembly from turning by holding it with the 7/64 in. Allen wrench. IMPORTANT: Do not hold onto the float assembly while tightening the 1/2 in. hex nut. Holding onto the float assembly may cause the float arm to twist and result in malfunction of the auto-drain. Wall Bracket for Small, Horizontal, Single Compressors and Tanks Rugged 1/8 in. A-4000-108 Angle Iron Brackets (see Figure 16) may be used to mount a compressor on a wall where floor space is limited. These brackets may be used for single compressors with up to 30-gallon tanks. Figure 16: A-4000-108 Wall Bracket (1/8 in. Plate Metal), in./mm Floor Legs for Horizontal Tanks A-4000-109 Floor Legs (made from U-channel, see Figure 17) for mounting horizontal tanks 12 in. off the floor are available to meet building requirements and facilitate cleaning under the compressor. Figure 15: A-4000-6010 Filter Auto-Drain Assembly Figure 17: A-4000-109 Floor Leg 7

Intake Air Filter The dry-type intake air filters (see Figure 18) are rated 99% efficient at a 10 micron rating, regardless of air demands or temperature variations. A steel housing with baked enamel finish makes these filters suitable for either outside or inside locations. Figure 18: Intake Air Filters Figure 19:, in./mm (See Table 6) Table 6: Code Capacity Connection, in. (mm) Number A B C A-4000-612 15 scfm (7.1 l/s) 3/4 in. NPT 6 (152) 4 (102) 4-1/4 (108) A-4000-613 30 scfm (14.2 l/s) 1-1/4 in. NPT 6 (152) 6-3/4 (172) 7 (178) A-4000-635 5 scfm (2.4 l/s) 1/2 in. NPT 2-1/2 (64) 3 (76) 2-7/8 (73) Table 7: Replacement Filter for A-4000-115 Code Description Number F-1000-232 Replacement filter for the discontinued A-4000-115, 5 scfm (2.4 l/s), 1/2 in. NPT connection 8 Published in U.S.A. Building Efficiency 507 E. Michigan Street, Milwaukee, WI 53202 Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. 2013 Johnson Controls, Inc. www.johnsoncontrols.com