VACUUM CONTROL SPI-MODULE INSTRUCTION MANUAL

Similar documents
SPI Supplies Vacu Prep II TM Operation Manual

Analog Condensate Monitor Instruction & Maintenance Manual

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY

SE2000BX Static Exciter

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Ford Meter Box Test Bench Installation Instructions

AUTO PUMP 12V MODEL #: V 12 VOLT DC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. INPUT: Volts DC, 11 Amps OUTPUT: 100 PSI Max

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

AUTO-PUMP 12V HP-VER FOR VERTICAL MOUNT ONLY MODEL #: V-HP-VER 12VDC HIGH OUTPUT AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

Automated I.V. Stand Cat. No OPERATOR S MANUAL. Operation& Maintenance Instructions. Raising the Standard of Care!

COMPRESSED AIR LOADER MODEL: AL-1

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

PORTABLE POWER SUPPLY MODEL NUMBER VMS-1 VERSION 1.0

Operating Instructions for the. In Line Conveyor System West Cabot Boulevard Langhorne, PA w w w.empire-airblast.

OPERATION and MAINTENANCE INSTRUCTION MANUAL

MITYFLEX PERISTALTIC PUMPS

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL

Model G14SD Vapor Management System

INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Operators Manual. Recirculating Chiller /06/08

OWNER'S MANUAL & INSTALLATION INSTRUCTIONS 6500 Series

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345

1.4 N/1.4 D. Operating Instructions. 580 Mayer Street, Building #7, Bridgeville, PA phone fax

AD-830. Parts Manual thru 1997

Model LA 4300 Time Delay OFF Controller

OPERATION and MAINTENANCE INSTRUCTION MANUAL. AEU-70A Peristaltic Infusion Pump

XENON POWER SUPPLY 4000 Watt Gladiator IV

Model LA 4100 Time Delay OFF Controller

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

INSTALLATION INSTRUCTIONS For Model 855 Wolo Express TM

Centrifugal Separator Operations & Maintenance Manual

DWYER INSTRUMENTS, INC. Phone: 219/ P.O. BOX 373 MICHIGAN CITY, IN 46361, U.S.A. Fax: 219/

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY


UV DISINFECTION UNIT MODEL 3G

Model 809 Diaphragm Gauge Controller

PEANUT ROASTER Instruction Manual Model #5081

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

SPC-PANEL Simplex, Single Phase Pump Control Panel

Users Manual. Phase Rotation Indicator

Installation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Model LA 4400 Time Delay OFF Controller

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Vacuum Gauge Catalog

AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

AUTO CHARGE 11HO PIM AUTOMATIC BATTERY CHARGER

EZ SDI TM Booster Pump Assembly

DENTONVACUUM DESKV DESK V - SPUTTER/ETCH UNIT AND ACCESSORIES

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

ALU-29CF Portable Light NSN:

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

Countertop B.I.B. Butter Dispenser Instruction Manual Model #2496

SOFT TOUCH FOR PNEUMATIC RIVETERS

SOFT TOUCH for PNEUMATIC RIVETERS

Pump Installation and Service Manual HRS Hydromatic Retractable System

SELF PRIMING CHEMICAL SERVICE PUMPS

Corrosion Coupon Rack

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Myers Vacuum RD # 2 Box 247A Kittanning, PA Phone: Fax: Instruction Manual For Thermistor Gauge GT-340A

INDIAN INSTITUTE OF TECHNOLOGY KANPUR Kanpur , Uttar Pradesh, India Centre for Lasers and Photonics

GLOBE FLOWCELL. Operating Manual. Rola-Chem Flowcell PN /01/2013 page: 1 of 8

The Gaylord Duct Sump Maintenance Manual For Model "GDS" GAYLORD INDUSTRIES

LIQUID DIELECTRIC TEST SET MODEL NUMBER LD60 VERSION 3.2

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Myers Vacuum 1155 Myers Lane Kittanning, PA Phone: Fax: Instruction Manual For Thermocouple Vacuum Gauge GTC-390

Refinery Supply Company, Inc.

Model TC-20. Tube Cut-Off Machine. Operator s Manual REV H

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET

TactAir 4-Stage PCP Hand Pump. Operation Manual

WIRING DIAGRAM, MILLENNIUM TM MODEL YT (STYLE J) LIQUID CHILLERS GRAPHIC CONTROL CENTER WITH ELECTRO-MECHANICAL STARTER PRODUCT DRAWING JOB DATA:

S25500 MAXI STIRRER OPERATION MANUAL AND PARTS LIST SERIES 849

I N S TA L L AT I O N

Undercounter Refrigeration Design Guide

advanced FLOW engineering Instruction Manual P/N: Make: RAM Model: 1500 EcoDiesel Year: Engine: V-6 3.0L (td)

Phenix Technologies Inc. 75 Speicher Drive Accident, Maryland 21520

Cooling Module. Instruction Manual

shadow focus floodlight SFS-300 INSTRUCTIONS

Export Bucket Pump Instruction Manual Models: 2114XE & 2114XD

Installation, Operation, and Maintenance Manual

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

TS69 TS65 TS55 TS45 TS5768 TS SERIES INSTALLATION/OWNER'S MANUAL

INSTRUCTION MANUAL CAUTION

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

Dispenser & Warmer RIC-1909 RIC-1909EXP

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

600 Amp Battery Jumper with Air Compressor

PRO IV LIQUID DETERGENT & LIQUID RINSE DISPENSER INSTALLATION INSTRUCTIONS REVISION #5

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Operation & Service Manual

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

G8 Portable Fuel Transfer Pump Owner s Manual

Transcription:

SUPPLIES R VACUUM CONTROL TM SPI-MODULE INSTRUCTION MANUAL SPI Supplies Division of STRUCTURE PROBE, inc. 69 East Gay Street, P.O. 66, West Chester, PA 1981-066 (610) 46 400 Fax: (610) 46-7 E-Mail SPISPI@SPI.com Website - http://www.spi.com Canada:Box 187,Postal Station "T", Toronto,Ontario,M6B 4A1 Canada (416) 787-919 800-668-08 Fax (416) 781-049 SPI Supplies is a registered trademark of Structure Probe,Inc.

Structure Probe, Inc. / SPI Supplies Street address for UPS, FedEx, DHL, other couriers, trucks 69 East Gay Street West Chester, PA 1980 Mailing address P.O. Box 66 West Chester, PA 1981-066 USA Toll-free from USA/Canada: 1-(800)-44-SPI Phone: 1-(610)-46-400 FAX: 1-(610)-46-7 E-mail: spispi@spi.com For further information regarding any of the other products designed and manufactured by SPI Supplies, contact your local representative or directly to SPI Supplies at the address above, or visit www.spi.com Carbon and Sputter coaters Plasma Reactor for ashing and etching High Vacuum Bench Top Evaporators Critical Point Dryers Electron Microscopy Supplies, Consumables and Accessories

Warranty The SPI Supplies unit you have purchased is guaranteed to be free of defects in workmanship on the day of shipment. This warranty covers parts and labor for a period of one year, excluding shipping charges or consumables. Breakage of glassware is specifically excluded from this warranty. Proper use of your unit, according to the operation manual, should result in trouble-free operation. Any improper use of the SPI Supplies unit through modifications or unreasonable operating procedures will void this warranty. DISCLAIMER SPI Supplies Plasma-Prep III is designed for simplicity of installation and operation. This manual provides full and complete information in both of these areas. SPI Supplies therefore assumes no liability or responsibility of any kind for damage or injury resulting from incorrect installation or operation of the machine. If any questions arise, call SPI Supplies from the USA/Canada 1-800-44-SPI or 1-610-46-400 for assistance. For all other countries, contact our nearest agent or SPI Supplies directly. A listing of our agents may be found on our website at: http://www.spi.com/info/agents/

TABLE OF CONTENTS A. SERVICES REQUIRED...4 B. GENERAL DESCRIPTION...4 C. INSTALLATION... D. TEST PROCEDURE...6 E. SPARE PARTS...7 4

A. SERVICES REQUIRED The following services are either required or optional for the operation of the SPI-MODULE CONTROL unit : 1. Power: Check the voltage label near the main power cord to ensure that the equipment has been supplied for the correct laboratory voltage and frequency. OPTIONAL. ARGON GAS (Industrial Grade ) : A commercial cylinder fitted with a two stage regulator so that a pressure of around psi can be obtained.. WATER: The base plate of the work chamber can be water-cooled if required. B. GENERAL DESCRIPTION The SPI-MODULE CONTROL unit has been designed as the basis of a range of SEM sample coating instruments. The main cabinet contains all the necessary hardware to control and monitor vacuum pressure within the work chamber. The front panel arrangement is shown in Figure 1. The meter measures chamber pressure both in millibars and millitorr units. The main power switch controls the power to the instrument and also to the vacuum pump when connected to the receptacle provided on the rear panel see fig. The needle valve controls the leak of the argon into the work chamber which, in turn will control the plasma current if the instrument is used in a sputtering mode. The back panel (figure ) houses all the service connections. The main power cord enters the rear of the instrument and the instrument is protected by a 1"x 1-1/4" 10 amp glass fuse. The vacuum pump is electrically connected to the receptacle on the rear panel and also to the 1/" brass tube extending out the rear by the shortest convenient length of rubber hose supplied. Argon gas is fed from the cylinder regulator head to the inlet fitting. Cool water may be circulated through the chamber base plate via the water fittings. The design of the base plate also acts as a baffle to condense any back streamed rotary pump oil. The vacuum interlocked power outlet is fused with a 1"x 1-1/4" 10 amp glass fuse, and is used to power the SPI-MODULE SPUTTER COATER or the SPI-MODULE CARBON COATER. The SPI-MODULE CONTROL unit can also house internally the SPI-MODULE QUARTZ CRYSTAL THICKNESS MONITOR. Fitting of this unit is described in a separate handbook.

C. INSTALLATION 1. The unit is supplied with the following parts packed separately: (I) SPI-MODULE CONTROL UNIT (II) PYREX CHAMBER 4" X " (III) CENTRAL STAGE AND SPECIMEN HOLDER (IV) ' RUBBER VACUUM HOSE (V) OPERATING MANUAL (VI) STAINLESS STEEL HOSE CLAMPS To complete a system the following SPI-MODULES may be supplied either or (I) (II) (III) SPI-MODULE SPUTTER COATER (with sputter head containing a mil gold cathode and cable) SPI-MODULE CARBON COATER (with carbon fiber head and cable and 1 meter of carbon fiber) An optional carbon rod head is available. Unpack the SPI-MODULE CONTROL unit and connect the vacuum pump inlet port to the brass tube with the shortest length of vacuum hose possible. Connect the pump electrical cord to the pump receptacle on the rear of the unit. Check that the pump is filled with oil and is ready for use in accordance with the manufactures instructions provided.. Connect the outlet of the argon cylinder regulator head to the gas inlet fitting on the rear panel see fig and set to psi. 4. The base plate of the work chamber can be water cooled if coating of very delicate specimens is attempted. The cooling water can be connected to the two quick disconnects on the rear panel (see fig ) 1/8" o.d. nylon tubing is necessary (not supplied).. Place the glasswork chamber onto the base plate and locate it into the "O" ring grove. Fit the sputter or carbon fibber head whichever is appropriate for the work to be done onto the top of the glass chamber. At this stage do not make any electrical connection to this head. 6. Plug the power cord into a laboratory receptacle of the correct voltage. The unit is now ready for use. 6

D. TEST PROCEDURE Having connected all electrical cables and services the unit can now be test run. Check that the gas leak valve is fully closed (clockwise) and that the argon regulator is open and the pressure is set at about psi. WARNING: OVER TIGHTENING THE VALVE MAY CAUSE DAMAGE TO THE VALVE. 1. Switch on the power. The vacuum pump will start immediately and after 10-1 seconds (depending on the pump size) the vacuum gauge will register the fall in pressure inside the chamber. The unit should be left running until the gauge reads in the range of 60-80 millitorr. This indicates there are no major leaks in the system.. Open the gas leak valve (counterclockwise) and observe the rate of rise of the pressure relative to the position of the leak valve.. Finally, close the gas valve and, turn off the 'POWER' switch and vent the chamber with the vent valve on the top of the head. This completes the test run of the SPI-MODULE CONTROL unit and the various evaporation controls; modules can now be connected in accordance with their own manuals. 7

E. SPARE PARTS LIST FOR VACUUM CONTROL BASE MODULE SPI # 114-AB PART. VC1/1 V10H/1 VM0/1 1100H-AB DESCRIPTION 10A Fuse 1/4"x 1-1/4" Glass (Slo Blo) Metal Hose 40 Inches Long KF16 Flange Flange Clamp KF16 Rubber Vacuum Hose (specify length) V7/1 Moducel Vacuum Sensor & Control V8/1 Meter Vacuum Gauge VM1/1 114PS-AB 11446-AB 1148-AB 11460-AB Needle Valve Power Supply Pyrex Chamber Set of O-rings for Pyrex Chamber Set of O-rings for Vacuum Base V4/ Relay 10 volt V4HV/ Relay 40 volt 8

PUMP RECPT LI G MODULE RECPT L1 G 6 70006-0 4 1 VOLT POWER SUPPLY 7 8 1 8 _ 70061 CALBRATION BOARD M1 F1 SW1 MODUCELL 4 8 7 6 1 0 MICROAMP L1 PL1 G N RLY1 10 1 N N + + _ 9 11 110 V CONNECTIONS 110 VOLTS RLY DWG. 7001 SPI. 114 AB TITLE VACUUM CONTROL BASE SCHEMATIC DATE 8/6/9 DRAWN BY A.L.M. REV.. 9 10 F 10 A 9 1 11 4 6 70006-0 0 VOLTS 1 VOLT POWER SUPPLY 7 8 1 0 V CONNECTIONS

Voltage Regulator C1+ DWG.. Bridge Rectifier D1-D4 DESC. DATE 4/1/99 DRAWN ALM BY REV.. 10 V AC 0/60 HZ T1 781 1 POWER SUPPLY 6 7 8 1 VOLT DC SUPPLY 10

Function/Service Chart for Vacuum Base Power to the vacuum base on Vacuum pump on if connected to Vacuum Base Meter deflects to the right check relay check 1 Volt power supply meter moves to left to indicate pressure Replace Power Supply Check Votage output from Moducell pins #, 8 approx. Volts Moducell at fault or look for vacuum leaks Energizes receptacle for modules Replace Moducell # V7/1 Check Voltage at meter posts approx. 9 millivolts Replace Meter # V8/1 Replace Calibration Board # V8/1R Check Relay RLY terminals 10, for 110 volts ac or Moducell at fault Vacuum Base functioning correctly for other faults see function/service chart for Sputter/Carbon Module 7/7/011 for questions contact SPI Supplies Tele: 610 46 400 spi@spi.com 11