Coaxial Pulse Tube Microcryocooler

Similar documents
Qualification of Lockheed Martin Micro Pulse Tube Cryocooler to TRL6

Development of a Joule-Thomson Micro Compressor

Efficient High Capacity Space Microcooler

Pulse Tube Microcooler for Space Applications

Cryocooler with Cold Compressor for Deep Space Applications

Development of a J-T Micro Compressor

Overview of Micro-Miniature Stirling Cryocoolers for High Temperature Applications

Experimental Investigation of a 40K Single Stage High Frequency Pulse Tube Cryocooler

Development of the LPT W Concentric Pulse Tube

Gas Spring Effect in a Displacer Pulse Tube Refrigerator

MIRI Cooler System Design Update

The Development of a New Generation of Miniature Long-Life Linear Coolers

An Advanced Compressor for Turbo-Brayton Cryocoolers

LPT6510 Pulse-tube Cooler for K applications

Miniature cryocooler developments for high operating temperatures at Thales Cryogenics

The BEI OWL cooler is one of many in a family of linear Stirling-cycle cooler designs developed by the company.

Long Transfer Lines Enabling Large Separations between Compressor and Coldhead for High- Frequency Acoustic-Stirling ( Pulse-Tube ) Coolers

Pressure Ratio Effect to Warm Displacer Type Pulse Tube Refrigerator

High Capacity Flexure Bearing Stirling Cryocooler On-Board the ISS. Sassenage, France (2) THALES Cryogenics B.V. Eindhoven, The Netherlands

ABI Cooler System Protoflight Performance

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Chart, Inc. Data Sheet 2s241K Cryocooler

Development of a High Frequency Pulse Tube

Small Scale Cooler: Extending Space Developed Technology into Adjacent Markets

HIGH CAPACITY TWO-STAGE PULSE TUBE

Characterization Testing of Lockheed Martin Standard Micro Pulse Tube Cryocooler

NIRCam Filter Wheels

Design of a Large Heat Lift 40 to 80 K Pulse Tube Cryocooler for Space Applications

Data Sheet 2s102K Cryocooler

Development of a High Frequency Pulse Tube

Characterization Testing of the Thales LPT9310 Pulse Tube Cooler

Reduction of Self Induced Vibration in Rotary Stirling Cycle Coolers

Available online at ScienceDirect. Physics Procedia 67 (2015 )

A Thermoacoustically Driven Two-Stage Pulse Tube Cryocooler

COLD PLATE SOFTWARE PROGRAM ANALYZES AIRCRAFT

Development of a 6W high reliability cryogenic cooler at Thales Cryogenics

PMT DARK CURRENT REDUCTION USING THERMOELECTRIC COOLING UNIT TE-206TSRF

Liquid Nitrogen Research Dewars

RICOR'S K508N HIGHLY RELIABLE INTEGRAL ROTARY CRYOGENIC COOLER

A Prototype Oil-Less Compressor for the International Space Station Refrigerated Centrifuge

Use of Flow Network Modeling for the Design of an Intricate Cooling Manifold

Statement of Jim Schoppenhorst, Director, DD(X) BAE Systems / Armament Systems Division. Before the

A view on the functioning mechanism of EBW detonators-part 3: explosive initiation characterisation

Air Bearing Shaker for Precision Calibration of Accelerometers

Clearance Loss Analysis in Linear Compressor with CFD Method

Ambient Magnetic Field Compensation for the ARIEL (Advanced Rare IsotopE Laboratory) Electron Beamline. Gabriela Arias April 2014, TRIUMF

Reliability Evaluation of Stirling Cryocooler for an Electric Vehicle High Temperature Superconducting Motor System

Effect of Compressor Inlet Temperature on Cycle Performance for a Supercritical Carbon Dioxide Brayton Cycle

Substation inspection guidelines Mark B. Goff, P.E.

Development of a Self-latching Hold-down RElease Kinematic (SHREK)

MOS Section Ken McCracken

Advanced Battery Models From Test Data For Specific Satellite EPS Applications

Novel Munitions Power Systems

QuickStick Repeatability Analysis

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

Monthly Progress Report January 2005

Linear Cryogenic Coolers for Hot Infrared Detectors

Earlier Lecture. For an optimum design of a Stirling cryocooler, a compromise between the operating and the design parameters may be sought.

Seventh Framework Programme THEME: AAT Breakthrough and emerging technologies Call: FP7-AAT-2012-RTD-L0 AGEN

Manufacturing Implications within. new DODI (Dec 8, 2008) Summary for Industry. National Center For Advanced Technologies.

Data Sheet 2s102K Cryocooler

VI Chip BCM Bus Converter Thermal Management

The Deployable Gage Restraint Measurement System - Description and Operational Performance

A First Principles-based Li-Ion Battery Performance and Life Prediction Model Based on Reformulated Model Equations NASA Battery Workshop

SPACE COOLER DEVELOPMENTS AT THALES CRYOGENICS TO FIGHT TRIBOLOGICAL FAILURE PHENOMENA

2009 JSPE - Saft. Advanced Lithium Power Sources Real World Experience

HIGH VOLTAGE vs. LOW VOLTAGE: POTENTIAL IN MILITARY SYSTEMS

RDT&E BUDGET ITEM JUSTIFICATION SHEET (R-2 Exhibit) June 2001

A First Principles-based Li-Ion Battery Performance and Life Prediction Model Based on Single Particle Model Equations

M. A. Green, and S. Yu Lawrence Berkeley National Laboratory, Berkeley CA 94720, USA

ECSE-2100 Fields and Waves I Spring Project 1 Beakman s Motor

The AGM-114K-2A Missile Enhanced Lethality Design and Test

A thin film thermoelectric cooler for Chip-on-Board assembly

NOVEL DIAPHRAGM BASED STIRLING CRYOCOOLER. A.J. Caughley 1, A Tucker 2, M Gschwendtner 3, and M Sellier 2 ABSTRACT

Scroll Compressor Oil Pump Analysis

Building Blocks and Opportunities for Power Electronics Integration

for Critical Applications in Extreme Environments

CASED TELESCOPED SMALL ARMS SYSTEMS

UNCLASSIFIED FY 2017 OCO. FY 2017 Base

TELEDYNE STORM MICROWAVE. even in space TELEDYNE. Everywhereyoulook. Tel Fax Toll Free

LOW SHOCK NON-EXPLOSIVE ACTUATOR

Future NASA Multi-kilowatt Free Piston Stirling Applications

UNCLASSIFIED. UNCLASSIFIED Army Page 1 of 11 R-1 Line #130

ADVANCED STEEL OFFERS AUTOMAKERS AGGRESSIVE ENGINE DOWNSIZING

REPORT TO THE CHIEF ADMINISTRATIVE OFFICER FROM THE DEVELOPMENT AND ENGINEERING SERVICES DEPARTMENT COMPRESSED NATURAL GAS TRANSIT FLEET UPDATE

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

Li-ion battery and super-capacitor Hybrid energy system for low temperature SmallSat applications

Low Vibration Microminiature Split Stirling Cryogenic Cooler for Infrared Aerospace Applications

Mobile Air Conditioning (MAC)

Improvement Curves: Beyond The Basics

Army Ground Vehicle Use of CFD and Challenges

A Recommended Approach to Pipe Stress Analysis to Avoid Compressor Piping Integrity Risk

Annual Press Conference 2011 Results

REVERSE TURBO BRAYTON CYCLE CRYOCOOLER DEVELOPMENT FOR LIQUID HYDROGEN SYSTEMS

MODELING SUSPENSION DAMPER MODULES USING LS-DYNA

Salakhov R.R Salakhov Rishat Rizovich, Candidate of Technical Sciences, Director, Research Institute of Energy Efficient Technologies, KNRTU-KAI

Advanced Cooling Technologies, Inc. Low-Cost Radiator for Fission Power Thermal Control NETS Conference

Joint Unmanned Aircraft System Mission Environment (JUAS-ME)

LOW SHOCK RELEASE UNIT EASY RESETTABLE AND 100 % REUSABLE. Jens Müller 1, Christoph Zauner 2

Reliability of LoPak with SPT

Transcription:

Coaxial Pulse Tube Microcryocooler J. R. Olson 1, P. Champagne 1, E. W. Roth 1, G. B. Kaldas 1, T. Nast 1, E. Saito 2, V. Loung 2, B. S. McCay 2, A.C. Kenton 3, C.L. Dobbins 4 1 Lockheed Martin Space Systems, Palo Alto, CA 94304, USA 2 Lockheed Martin Missiles & Fire Control, Goleta, CA 93117, USA 3 DCS Corporation, Shalimar, FL 32579, USA 4 U.S. Army, Redstone Arsenal, AL 35898, USA ABSTRACT We report the successful completion and initial testing of the Lockheed Martin first-article, single-stage, compact, coaxial pulse tube microcryocooler. This cryocooler supports cooling requirements for emerging high operating temperature (125-150K) infrared focal plane array sensors with nominal cooling loads of ~500mW@125K. We present new coaxial pulse tube cooling performance test measurements with comparisons to the design predictions and the in-line pulse tube measurements. The microcryocooler exhibits small size, volume, weight, power and cost features that warrant further component enhancements and manufacturing process maturation for a variety of space and tactical applications. INTRODUCTION A low SWaP (size, weight, and power) prototype single-stage, coaxial pulse tube microcryocooler (PTM) was successfully completed, tested, and integrated by Lockheed Martin into a new High Operating Temperature (HOT) nbn mid-wave infrared (MWIR) camera system. This effort follows the development of the initial high-performance microcompressor component reported at the 2013 Cryogenic Engineering Conference in Anchorage, AK 1. The new first-article PTM includes an optimized compact cold head and dewar assembly developed and tested in 2013. The referenced paper provides the motivation and plan for development of this scale microcryocooler device that is intended for both tactical and space cooling applications 1. This paper provides updated specifications, initial performance measurements, and modeling results on the completed coaxial PTM. Additional in-line measurements are also presented for better understanding and developing near-term coaxial PTM enhancements. COAXIAL PULSE TUBE MICROCRYOCOOLER Figure 1 shows the split configuration PTM comprised of the microcompressor, cold head assembly, and transfer tube. The cold head shown at the top consists (from right to left) of the cold tip, pulse tube, warm flange, and reservoir volume that contains the inertance tube. The dimensions of the first-article microcryocooler are shown in Figure 2. The micro- compressor size is 90mm x 32mm diameter and consists of two moving magnet motor modules with Cryocoolers 18, edited by S.D. Miller and R.G. Ross, Jr. International Cryocooler Conference, Inc., Boulder, CO, 2014 51

54 52 MICRO & MINIATURE Micro & 50-200K Miniature SINGLE-STAGE 50-200K Single-Stage CRYOCOOLERS Cryocoolers 49 Figure 1. First Article Coaxial Pulse Tube Microcryocooler. Figure 2. Microcompressor and Cold Head Assemblies (dimensions in mm). dual-opposed pistons and a central hub. The pulse tube cold head assembly is 111 mm long and 42 mm diameter. The cold finger is 61 mm long with a 9.7 mm diameter. The first-article microcryocooler weighs 328 grams. This includes the 118 grams cold head assembly and the 210 grams microcompressor. This does not include the mass of the dewar, sensor, or cooler drive electronics. The cold head mass can be reduced to 65 grams by replacing the copper warm flange with aluminum. This is one change being considered in a subsequent fabrication. The Lockheed Martin microcompressor design includes long-life flexure bearings and several key fabrication methods and procedures that minimize assembly labor. These features translate to increased device reliability and lower projected costs for the tactical cooler applications (assuming a reasonable production volume).

50COAXIAL PULSE TUBE MICROCRYOCOOLER 53 55 Figure 3 shows the first-article PTM assembled with the dewar. The dewar houses the camera window, an IR cold filter, a cold shield to limit stray radiation, the IR focal plane array (FPA), a getter, and the readout integrated circuit (ROIC) cold-side electronics required for camera functional interfacing. The FPA is attached to the end of the cold finger and is surrounded by a cold shield inside the evacuated dewar. Figure 4 shows the integrated dewar detector microcryocooler assembly (IDDMA) installed into the camera chassis. The overall size of the prototype camera (excluding the IR lens) is: 7.2" x 4.6" x 3.9" (18.3 x 11.7 x 9.9 cm). It has not yet been optimized for size in order to minimize risk and focus on the PTM development. The cooler and camera electronics used were developed for another system. Even with these non-optimized subsystems, the layout shown is smaller than typical high performance IR cameras. There are several paths that can be pursued to repackage the subsystems in order to modify or minimize size, weight, and/or volume of the prototype. COAXIAL PULSE TUBE MICROCRYOCOOLER PERFORMANCE Coaxial Pulse Tube Microcooler Cooling Load Lines and Cool Down Time The measured first-article coaxial PTM load lines are shown in Figure 5. The left graph shows the net cooling power as a function of cold tip temperature (K) for compressor electrical input powers spanning 5 to 20W at a heat rejection temperature of 300K. The graph to the right shows the specific power (electrical power / cooling power) also as a function of the cold tip temperature and compressor electrical input power. The design was optimized for the temperature range of 125-150K specifically for use with Hot IR nbn FPAs but provides cooling capability at other temperatures as Figure 3. Integrated Dewar Detector Microcryocooler Assembly (IDDMA). Figure 4. HOT nbn MWIR camera with installed microcryocooler.

56 54 MICRO & MINIATURE Micro & 50-200K Miniature SINGLE-STAGE 50-200K Single-Stage CRYOCOOLERS Cryocoolers 51 Figure 5. Coaxial Pulse Tube Microcryocooler Cooling Power and Specific Power Measurements. well. The highlighted 150K design point shows a net cooling power of 690 mw with a specific power of 14.5 W/W. The PTM can also provide 400 mw of cooling power and 25 W/W specific power at a cold tip temperature of 125K. These values meet initial microcryocooler project goals and meet the cooling needs for HOT IR FPAs. The measured load lines show that the first-article PTM is capable of higher input power and cooling. This provides adequate margin for many cooling applications. The PTM can operate with a heat rejection temperature as high as 71 C and as low as cryogenic temperatures 2. The ability to operate over a wide range of ambient temperatures typical of ground tactical requirements and military specifications is an important feature of the PTM. Excess cooling capacity is not exhibited in most other low SWaP camera systems emerging commercially. Their cooling capacity, specifically at the higher ambient temperatures, may prove to be insufficient for ruggedized tactical needs. Table 1 presents a performance summary of the first-article compact coaxial pulse tube microcryocooler. This table lists key cooler parameter measurements at the two temperature design points and weights of the two cooler subassemblies. The microcryocooler was also subjected to thermal and vibration environmental testing required for space-qualified use. The unit admirably passed these tests qualifying it at a Technology Readiness Level (TRL) of 6, an important step toward space readiness. These test results and associated space applications are reported in a companion paper at this conference 2. Table 1. First Article Coaxial Pulse Tube Microcryocooler Performance.

52COAXIAL PULSE TUBE MICROCRYOCOOLER 55 57 The initial cool down time measurements are plotted in Figure 6 and listed in Table 1. The microcryocooler was not optimized to minimize cool down time, but reducing cool down time for the tactical ground applications is part of ongoing 2014 performance enhancements, with a goal of 2-3 minutes between turning on the cooler and the onset of IR imaging. Coaxial and In-Line Pulse Tube Microcooler Performance Comparison Figure 7 compares the measured cooling power for the coaxial pulse tube with the previous inline pulse tube microcooler measurements presented in 2013 1. The measurements show that the coaxial cold head performs slightly better than the in-line cold head despite having a hotter ambient environment. The in-line cold head is still an important optimization tool, since it is easier to test the effects of design changes using the in-line test cooler prior to committing to the fabrication of a coaxial cold head. In-Line Pulse Tube Microcooler Orientation Dependence Pulse tube coolers usually have some sensitivity to orientation with respect to gravity. Performance is best when the pulse tube is oriented with its cold end down; degraded performance is usually observed as the tube is tilted away from vertical. Figure 8 shows measured data from the inline pulse tube cooler as a function of the tube s orientation (0 is the cold end down). For a ground- Figure 6. Coaxial Pulse Tube Microcryocooler Cool Down Time Measurements. Figure 7. Comparison of Coaxial (blue) and In-Line (green) Pulse Tube Microcryocooler Measurements.

58 56 MICRO & MINIATURE Micro & 50-200K Miniature SINGLE-STAGE 50-200K Single-Stage CRYOCOOLERS Cryocoolers 53 based camera, the pulse tube is usually oriented horizontal (90 ). This horizontal position is annotated on the measured data shown in Figure 8. The data show that, at a constant electrical input power of 20W, 8% of the cooling power is lost when tilting from vertical to horizontal. Thus, this effect is significant. Modifying the cold head orientation within the camera package may be desired to minimize input power. Comparison of Measured and Predicted Cooling Power Figure 9 compares the measured coaxial PTM load line shown in Figure 5 to the predicted PTM model results. As observed, the agreement is very good, with differences only on the order of 10%, and with a closer agreement in the temperature range and power level of primary interest. Modeling confidence grows as more measurements reasonably correspond to model predictions. Consequently, modeling is being used to assess a variety of design changes to our baseline microcryocooler configuration. Coaxial Pulse Tube Microcryocooler Enhancements Threshold cooling power goals were met for the first-article coaxial PTM. Desirable objective goals include lower specific powers obtained by higher efficiencies (e.g., ~10-12 W/W @150K). An Enhanced Pulse Tube Microcryocooler study task began in 2014 using in-line pulse tube measurements (with the current microcompressor) to perform trade-offs of promising engineering improvement approaches. Lockheed Martin pulse tube model predictions were also used to guide and assess results. Topics of the 2014 experimental and modeling studies for an enhanced PTM include: Warm flange mass redesign with lighter materials and reduced size Cool down time reduction (required for tactical ground applications) o Higher electrical drive / higher cooling power o Lower heat capacity / lower thermal mass dewar o Pulse-tube redesign (reduced length, diameter, and wall thickness) Reservoir Volume Reduction Cold head / Inertance Tube Repackaging Regenerator / Heat Exchanger Improvements Motor modifications Improved Cooler Electrical Drive Control The experimental in-line pulse tube measurements, modeling predictions, and analyses of initial results were promising. The improvements are being prioritized. Some will be implemented Figure 8. In-Line Pulse Tube Microcryocooler Orientation Measurements. Figure 9. Comparison of Measured (blue) and Model Predicted (brown) Coaxial Pulse Tube Cooling Power.

54COAXIAL PULSE TUBE MICROCRYOCOOLER 57 59 and tested in the next enhanced coaxial pulse tube cold head and dewar development expected to be completed in 2014. Selected demonstrated results will be presented in 2015. SUMMARY This paper presents continuing progress of our microcryocooler project. We report completion and testing of the first article compact coaxial pulse tube microcryocooler as a sequel to the previous completion of the microcompressor and in-line tests presented in 2013 1. This new unit demonstrates adequate cooling power performance, especially for a first article unit. Additional effort is in progress to enhance performance in several critical areas. An area of interest for AMRDEC tactical applications is reducing the closed-cycle cool down time in order to meet rapid deployment needs while retaining benefits of the now-demonstrated or projected size, weight, power, and cost improvements of a coaxial microcryocooler. ACKNOWLEDGMENTS This work is supported by Lockheed Martin Space Systems Space Technology Advanced Research (STAR) Labs and Lockheed Martin Missiles & Fire Control Santa Barbara Focal plane collaborative Internal Research & Development (IR&D) projects. Additional support by the AMRDEC 6.2 Missile Systems R&D Program: Next Generation Tactical Cooled / Uncooled IR Sensors and Seekers Project is acknowledged. Appreciation is expressed to Sam B. Wood of AMRDEC s Weapons Development and Integration Directorate for his long-standing technical leadership of applied infrared technology RDT&E for the ground tactical U.S. Army warfighter. REFERENCES 1. Olson, J.R., Champagne, P., Roth, E., Nast, T., Saito, E., Loung, V., Kenton, A.C., Dobbins, C.L., Microcryocooler for Tactical and Space Applications, Adv. in Cryogenic Engineering, Vol. 59, Amer. Institute of Physics, Melville, NY (2014), pp. 357-364. 2. Nast, T.C., Roth, E., Olson, J.R., Champagne, P., Frank, D., Qualification of Lockheed Martin Micro Pulse Tube Cryocooler to TRL6, Cryocoolers 18, ICC Press, Boulder, CO (2015), (this proceedings).