Size and Configurations

Similar documents
Hison Axial Flow Fans

Hison Axial Flow Fans

CONTENTS. Page. Adjustable Axial Pitch Flow Fans 3. Dimensions 4. AP056 Performance Curves 5. AP056 Sound Performance 6. AP063 Performance Curves 7

Explanation of AR Series Ventilator Products. Fan type code D S AR AE

MAJAX-2 GENERAL SPECIFICATION

Duct mounted fans. axial flow. Pacific HVAC Engineering Tel. Australia NZ

Series TDA DIRECT DRIVEN MODEL: TDA- 450/9AA/8-8/ / Construction. Airflow Direction

AND AXIAL FLOW FANS ECOFIT

Section 4. Axial Fans - Section 4

S ACON SEACON SEACO QUIPMEN EQUIPMENTS SEACON EQUIPMENTS

NOVENCO FAN CATALOGUE

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

AXIAL FANS & VANEAXIAL FANS

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

NEW GENERATION SERIES

Short casing. Long casing (L version) Commercial premises

AXIAL FANS Catalogue CN0050C01 May 2008

BIFLOW SB CON Product Brochure

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

High voltage flameproof induction motors The simplest solution for hazardous environments

TGT Series Adjustable Pitch Fans

CYLINDRICAL CASED AXIAL FLOW FANS

DESIGN GUIDELINES FANS PAGE 1 of 7

JM Aerofoil Multi-Stage 50 Hz

Axial fans. What s more, non-stock models are normally available within two weeks.

supplied in Form (B) configuration. Airflow over Impeller- Motor.

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Model LIDA. DIRECT DRIVE TUBEAXIAL FANS Model LIDA DIRECT DRIVE TUBEAXIAL FANS SECTION 12. Application. Options/Accessories

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

Bifurcated Case Axial Fans (BIFA)

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

TGT Series Adjustable Pitch Fans

Unobox units with backward curved centrifugal impellers

CGT Series Adjustable Pitch Fans

WINDER. Impellers with higher efficiency and less sound level

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

CGT Series Adjustable Pitch Fans

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS

AIRONN is a specialized organization

The Industrial Choice. Vane Section For Model VTBD. Model TTABD TUBEAXIAL & VANEAXIAL FANS. Type "T" Belt Driven Model TTABD / VTBD

ROOFMASTER STEF-HT ROOF FAN

ExpressBuild STANDARD FAN RANGE

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

SECTION HVAC POWER VENTILATORS

Aerofoil Ventilation Fans. Fantek. Quality & Performance at Affordable Prices

SECTION AXIAL HVAC FANS

Novenco axial flow fans. ZerAx - Standard January 2010

High Performance Axial Fans

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

REVOLUTION SLCX Product Brochure

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

NEW WINDER. Impellers with higher efficiency and less sound level

JM Aerofoil Bifurcated Fans

FIXED PITCH PROPELLER FANS

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Inline and Roof Mounted Fans

Twin City Fan & Blower

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Sabre Plate Mounted Sickle Fans (VSP)

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

JM Aerofoil Bifurcated 50Hz

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Axial Fans

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

Powerful centrifugal fans for universal use: The product ranges TEM and REM

The Industrial Choice. Model VB Direct Drive. Model VBBD Belt Driven VANEAXIAL FANS. Direct Drive & Belt Driven Model VB / VBBD

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

Max. airflow m 3 /s Diam. min. Diam. max


Fixed Pitch Vane Axial Fan

Centrifugal performance characteristics with axial flow pattern: RADAX VAR

Ventilation Fans and Equipment

Cutting-edge technologies backed by a century of experience

ROOFMASTER STEF-HT ROOF FAN

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

Design specifications

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

CENTAXIAL TUBULAR CENTRIFUGAL FANS. BIA Airfoil Blade Design Direct Drive & Belt Driven Model CBD / CDD (Class I, II & III) Model CBD Belt Driven

"LCA"- long cased axial fan

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Cast Iron Frame Motors For Zone 21 Improved Efficiency EFF2

Powerful centrifugal fans for universal use: The product ranges TEM and REM

GMP-Type. Key Features: Integrated Motor-Pump Units

Low Silhouette Power Roof Ventilator Propeller

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

F a n t y p e s J K K - J K K

CM5-5 A-R-A-E-AVBE F-A-A-N

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Transcription:

!!"#!""!"$%!!" &'()&('&

AK Axial Flow Fans the high efficiency direct-driven fan with adjustable pitch impeller specially designed to operate with low noise emission and vibration that meets the stringent requirements. Single and multi stage units 50 or 60 Hz. Casing Size and Configurations AK Axial Flow Fans offer a range of diameter sizes from 315 to 2000mm. Maximum efficiencies are obtainable by varying the number of blades which enable the fans to work at the most efficient parts of its performance characteristic. Casings are constructed from mild steel, hot dip galvanized after manufacture to BS729 as an anti-corrosive measure for longer life. The integral rolled flanges at the edges of the fan casing improves rigidity and maintains its cylindrical form allows for uniform impeller clearance thus reduce turbulence. Terminal box is fitted outside the casing with inspection port or access door. Impeller The aerofoil design impeller ensures maximum aerodynamic efficiency. Impeller blades are constructed of high strength cast aluminium alloy. Adjusted pitch angle design allows full flexibility to match precisely with design requirements. Motors Axial Flow Fans are incorporate with squirrel cage induction motor, totally enclosed and airstream rated to provide maximium protection. Design to comply with electrical standards BS5000 and IEC publication 34-1 and to mechanical standards BS4999 and IEC publication 72 for long life and reliability. Standards motors with class F insulation, IP55 enclosure and sealedfor- life bearings. 50Hz or 60Hz for Industrial and Marine Applications. Hazardous Areas AK Axial Fans can be configured with special motor and anti-spark tracks for operation in hazardous environments. Explosion-proof, increased-safety and non-sparking motors are available as options to fans for operation in zone 1 and 2 hazardous locations where explosive gas-air mixture is likely occur. Anti-Spark Design Used in combination with special motor operating in hazardous environments. It consists of an aluminium tracks positioned along the surface traversed by the impeller blades tips. The track is isolated from the casing by non-conducting material thus preventing the possibility of static electric spark. Epoxy Coating AK Axial Fans can be painted with additional protective coasting in situations where they are exposed to chemicals, solvents, salt water and other corrosive atmospheric conditions.

Fan Selection AK Axial Flow Fans selection is by fully computerizes software to ensure the design of fan meets the best optimize flow, static pressure and efficiency. This software also comes with the detail sound power level at different frequency to meet system design requirement. Fan Performance All fans are tested to the internationally recognized standard as according to methods described in ANSI / AMCA 210-99 (ISO 5801, DIN 24163). Fan performance has been tested and rated by AMCA approved Laboratory. Smoke Spill Ventilation - Certified by TÜV SÜD PSB AK axial fans has been tested comply to worldwide standard BS EN 12101-3:2002 F400 witnessing and certification by TÜV SÜD PSB Pte Ltd. Test conducted at 400 deg C for 120 minutes plus two minute mandatory stop. Therefore the AK axial fans are suitable for use when operated at or below the dynamic and temperature conditions. Marine Certification: Optional by Bureau Veritas International Register. More Impeller Design The Axial Flow Fans selection also comes with different type of impeller and material to suit your design, engineering and application needs. Fan Curves: Fan selected at most efficient operating point.

Dimensions (mm) and Weights

Dimensions (mm) and Weights

Ancillary equipment dimensions (mm) Distributor: Publication:AK/1.4/Axial/Sales