VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Similar documents
VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

NEW! Mounting clamp Guard grille Back draft shutter Circular duct silencer

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

VSA. Roof fans. Dachventilatoren. Roof fans

VKA VKAS VKA VKAS. Mounting clamp Guard grille Back draft shutter Circular duct silencer

KF T120. Kitchen fans. Wentylatory kuchenne KITCHEN FANS

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

CENTRIFUGAL IN-LINE FANS VENT Series

Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

ErP METAL TUBE FANS - ROPERA EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE INSTALLATION

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Wall mounted fan

KV sileo 100 M. Circular duct fans. Circular duct fans

Single-inlet centrifugal fans

In-Line Fans. Roof Fans. Fans ATEX. Centrifugal Fans. Chip Extractors. Domestic Fans. Accessories. Electric Diagrams. General Information.

CYLINDRICAL CASED AXIAL FLOW FANS

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

NEW Acoustic In-Line Fans (ACQ)

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

CMRT Series BACKWARD CURVED CENTRIFUGAL FANS. Backward curved centrifugal fans CMRT 80 C

Series VENTS KSK. Centrifugal kitchen fan in sound-insulated casing with air flow up to 8138 m 3 /h

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

CA V0 E RANGE In-line centrifugal fans in self-extinguishing plastic

ACCESSORIES FOR DUCT FANS

KUB T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Extractor de cocina KITCHEN FANS

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig CENTRIFUGAL FANS HV VAC &

Short casing. Long casing (L version) Commercial premises

NEW Slimpak EC Box Fan (SLPT EC)

Axial-flow Fan AFC. Model numbering system AF C / T. Accessories Three phase. Power rate 1.

VSA. Roof fans. Tourelles. Dachventilatoren. Крышные вентиляторы. Roof fans

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

Short casing. Long casing (L version) Highly versatile range due to different number of available blades and adjustable pitch angles

ACOUSTIC CABINET FANS CVAB / CVAT Series

CYLINDRICAL CASED AXIAL FLOW FANS TGT Series - ADJUSTABLE PITCH FANS

VORTICENT C E RANGE Centrifugal fans

Square Mixed Flow Fans (MFQ)

Inside Front cover White

Plate mounted axial flow fans HXBR / HXTR Series

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

ErP PLASTIC TUBE FANS - ESPADA FEATURES. ELECTRICAL SUPPLY V/50Hz/1f SIZES TEMPERATURE RANGE FEATURES AND CONSTRUCTION PRODUCT CODE

ACOUSTIC CABINET FANS CVB / CVT Series

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Roof Extract Fans DV Ventilation Hoods DLH Smoke Extract Fans ER

Circular Duct Fan prioair

AC axial fan. sickled blades (S series) Wall ring with guard grille

NCF fans 50 Hz. Protection class IP 55

TKC, TKS, TKV/TKH Roof fans

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

Sentinel D-Box Single Fan

Performance. Sound Levels. Impellers. Motors. Accessories

ErP POWERBOX EC FANS - ESTOC EC FEATURES ELECTRICAL SUPPLY TEMPERATURE RANGE SIZES FEATURES AND CONSTRUCTION PRODUCT CODE IMPELLER MOTOR

Unobox units with backward curved centrifugal impellers

CJBX CJBX/AL. Options. Order code CJBX 15/15 4. Technical characteristics

IN-LINE CENTRIFUGAL FANS FOR INDUSTRIAL / COMMERCIAL USE

Sentinel D-Box Twin Fan

TGT Series Adjustable Pitch Fans

AC Commercial Fans Edition. ErP ready

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

CK, LPK, LPKB. Duct fans with circular connection.

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Sabre Plate Mounted Sickle Fans (VSP)

Circular Box Fans - DAISHO EC Range DAISHO EC 125. Features. Electrical Supply. Product Code. Sizes 125, 150, 200, 250, 315, 450, 630 and 1000.

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Multifunctional 400ºC/2h and 300ºC/2h roof fans

In-line rectangular fans. Technical Catalogue

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

CSXRT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJSXR: Ventilation units with a backward-curved impeller

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

AC axial fan. sickled blades (S series) with guard grille for full nozzle

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

TGT Series Adjustable Pitch Fans

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

VKS VKSA. Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

Mixed Flow Roof Fans (RMH)

KF T120. Kitchen fans. Caisson de ventilation. Küchenabluftboxen. Boksventilator KITCHEN FANS

Duct Fans - ESTOC EC Range. Estoc EC Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630. Product Code

Mixed Flow Roof Fans (RMH)

CGT Series Adjustable Pitch Fans

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

MegaBox Product-specific information

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

BATHROOM EXTRACT FANS DECOR-100 Series

Transcription:

VKAP 3. Features Power supply Temperature range Diameter - 1 mm to 315 mm; Airflow up to 137 m 3 /h; Easily mounted in any position; Backward-curved impeller; Low ambient temperatures; Cost-effective. /5Hz/1f. -4 O C to 55 O C. Sizes 1, 125, 15, 16, 2, 25, 315. Construction Installation Speed control options Casing: galvanized sheet steel; Fan: centrifugal impeller and external rotor motor; Motor protection with built-in thermal-contact; Motor protection class: IP44; Terminal box protection class: IP55. Mounting with ducts: Spiro, flexible aluminium or plastic. Mounting bracket LAV is included. Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Electronic voltage controller (phase cut); Voltage controlled speed controller. VKAP 1 MD/LD 3. Product version Motor power level (M higher power level, L lower power level) Diameter Product name Accessories Single phase speed controller Single phase speed controller Mounting clamp Guard grille Back draft shutter Circular duct silencer TGRV p. 127 ETY p. 128 AP p. 189 AGO p. 181 RSK p. 177 AKS p. 174 2 The company reserves the right to make changes of technical data without prior notice

VKAP 3. Type Dimensions [mm] B C ød ød E VKAP 1 MD/LD 3. 189 152 244 1 287 VKAP 125 MD/LD 3. 182 143 243 125 286 VKAP 15 LD 3. 217 ± 2 166 ± 2 344 15 387 VKAP 16 MD 3. 189 143 244 16 287 VKAP 16 LD 3. 217 166 344 16 387 VKAP 2 MD 3. 219 167 344 2 387 VKAP 2 LD 3. 231 179 344 2 387 VKAP 25 MD 3. 223 16 344 25 387 VKAP 25 LD 3. 23 167 344 25 387 VKAP 315 MD 3. 243 175 42 315 444 VKAP 315 LD 3. 256 188 42 315 444 Type Accessories TGRV ETY AP AGO RSK AKS FD FDI EKA AVS AVA VKAP 1 MD/LD 3. 1,5 1,5 1 1 1 1 1 1 1 1 1 VKAP 125 MD/LD 3. 1,5 1,5 125 125 125 125 125 125 125 125 125 VKAP 15 LD 3. 1,5 1,5 15 15 15 15 - - - - - VKAP 16 MD 3. 1,5 1,5 16 16 16 16 16 16 16 16 16 VKAP 16 LD 3. 1,5 1,5 16 16 16 16 16 16 16 16 16 VKAP 2 MD 3. 1,5 1,5 2 2 2 2 2 2 2 2 2 VKAP 2 LD 3. 1,5 1,5 2 2 2 2 2 2 2 2 2 VKAP 25 MD 3. 1,5 1,5 25 25 25 25 25 25 25 25 25 VKAP 25 LD 3. 1,5 1,5 25 25 25 25 25 25 25 25 25 VKAP 315 MD 3. 1,5 1,5 315 315 315 315 315 315 315 315 315 VKAP 315 LD 3. 1,5 1,5 315 315 315 315 315 315 315 315 315 Filter cassette Filter cassette Electric duct heater Heating coil Duct water cooler FD p. 169 FDI p. 167 EKA p. 139 AVS p. 148 AVA p. 156 The company reserves the right to make changes of technical data without prior notice 21

VKAP 3. VKAP 1 MD 3. VKAP 1 LD 3. 7 6 5 4 3 2 1 14 12 1 1 MD 3. Lwa total, Inlet 61 45 57 52 56 51 4 31 Outlet 61 44 58 52 55 5 39 3 Surrounding 46 26 27 36 44 41 3 23 Measured at 2 m 3 /h, 62 Pa 8 6 4 1 LD 3. Lwa total, 2 Inlet 7 53 58 6 66 65 58 47 Outlet 71 54 6 61 67 66 58 48 Surrounding 61 34 58 44 55 54 47 37 Measured at 257 m 3 /h, 14 Pa VKAP 125 MD 3. 6 5 4 3 2 1 125 MD 3. Lwa total, Inlet 59 43 52 53 54 51 41 33 Outlet 6 42 53 54 54 52 42 34 Surrounding 45 21 3 36 42 4 29 18 Measured at 191 m 3 /h, 83 Pa 22 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice

VKAP 3. VKAP 125 LD 3. VKAP 15 LD 3. 14 12 1 8 6 4 2 18 16 14 12 1 125 LD 3. Lwa total, Inlet 69 5 54 63 65 64 56 47 Outlet 68 49 53 61 64 63 55 45 Surrounding 56 28 29 45 53 52 44 35 Measured at 28 m 3 /h, 14 Pa 8 6 4 2 15 LD 3. Lwa total, Inlet 74 51 66 67 71 62 61 53 Outlet 75 52 67 68 72 64 63 5 Surrounding 62 3 49 51 6 52 5 36 Measured at 595 m 3 /h, 112 Pa 1 MD 3. 1 LD 3. 125 MD 3. 125 LD 3. 15 LD 3. Voltage/Frequency [V/Hz] 23/5 23/5 23/5 23/5 23/5 [kw],48,74,5,77,15 Current [A],2,31,21,32,44 Speed [min -1 ] 275 28 275 28 28 Capacitor [µf] 4, 2, 4, 2, 2, Max. airflow [m 3 /h] 281 379 37 421 773 Max. air temperature [ C] -4/55-4/55-4/55-4/55-4/55 Weight [kg] 3 3 3 3 3 Wiring diagram No.2 No.1 No. 2 No.1 No.1 Protection class: motor IP-44 IP-44 IP-44 IP-44 IP-44 terminal box IP-55 IP-55 IP-55 IP-55 IP-55 Comply with ERP 216 216 216 216 216 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice 23

VKAP 3. VKAP 16 MD 3. VKAP 16 LD 3. 14 12 1 8 6 4 2 16 14 12 1 16 MD 3. Lwa total, Inlet 68 47 5 56 64 63 61 49 Outlet 69 48 52 57 65 64 63 51 Surrounding 56 26 27 4 53 51 5 35 Measured at 318 m 3 /h, 13 Pa 8 6 4 2 16 LD 3. Lwa total, Inlet 74 52 67 68 71 62 62 52 Outlet 75 52 68 68 72 64 63 51 Surrounding 61 31 49 52 59 52 51 36 Measured at 685 m 3 /h, 14 Pa VKAP 2 MD 3. 18 16 14 12 1 8 6 4 2 2 MD 3. Lwa total, Inlet 7 46 53 62 66 63 64 54 Outlet 71 45 54 61 68 64 65 53 Surrounding 55 22 24 41 49 53 43 4 Measured at 653 m 3 /h, 125 Pa 24 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice

VKAP 3. VKAP 2 LD 3. 2 18 16 14 12 1 8 6 4 2 2 LD 3. Lwa total, Inlet 73 53 6 66 69 66 65 63 Outlet 74 54 62 65 7 67 67 63 Surrounding 58 25 35 46 53 55 47 45 Measured at 846 m 3 /h, 123 Pa 16 MD 3. 16 LD 3. 2 MD 3. 2 LD 3. Voltage/Frequency [V/Hz] 23/5 23/5 23/5 23/5 [kw],75,16,17,135 Current [A],31,45,45,56 Speed [min -1 ] 28 28 26 266 Max. airflow [m 3 /h] 451 866 816 17 Capacitor [µf] 2, 2, 2, 4, Max. air temperature [ C] -4/55-4/55-4/55-4/55 Weight [kg] 3 4 4 4,7 Wiring diagram No.1 No.1 No.1 No.1 Protection class: motor IP-44 IP-44 IP-44 IP-44 terminal box IP-55 IP-55 IP-55 IP-55 Comply with ERP 216 216 218 218 VKAP 25 MD 3. 16 12 8 4 25 MD 3. Lwa total, Inlet 71 41 52 61 66 66 64 56 Outlet 72 43 53 6 68 67 65 57 Surrounding 52 24 3 38 48 47 45 4 Measured at 634 m 3 /h, 125 Pa The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice 25

VKAP 3. VKAP 25 LD 3. VKAP 315 MD 3. 2 18 16 14 12 1 8 6 4 2 35 3 25 25 LD 3. Lwa total, Inlet 74 54 62 67 69 67 67 65 Outlet 75 55 63 66 7 68 67 67 Surrounding 55 33 38 47 5 48 47 46 Measured at 81 m 3 /h, 123 Pa 2 15 1 315 MD 3. Lwa total, 5 Inlet 78 52 63 71 75 68 65 63 Outlet 79 53 64 71 76 69 68 66 Surrounding 57 35 43 51 53 48 46 43 Measured at 1195 m 3 /h, 152 Pa VKAP 315 LD 3. 35 3 25 2 15 1 5 315 LD 3. Lwa total, Inlet 73 5 59 67 68 66 65 64 Outlet 74 51 6 66 69 67 66 65 Surrounding 53 33 38 45 48 47 45 43 Measured at 18 m 3 /h, 149 Pa 26 The fan characteristic curves were determined in accordance with EN ISO 581. The sound levels were determined in accordance with DIN 45635 resp. ISO 3744 at a distance of 1 m from the fan. The company reserves the right to make changes of technical data without prior notice

VKAP 3. 25 MD 3. 25 LD 3. 315 MD 3. 315 LD 3. Voltage/Frequency [V/Hz] 23/5 23/5 23/5 23/5 [kw],16,132,22,238 Current [A],45,56,96 1,6 Speed [min -1 ] 26 246 2567 26 Capacitor [µf] 2, 4, 5, 5, Max. airflow [m 3 /h] 817 967 1372 1263 Max. air temperature [ C] -4/55-4/55-4/55-4/55 Weight [kg] 4 4,7 5,6 6, Wiring diagram No.1 No.1 No.1 No.1 Protection class: motor IP-44 IP-44 IP-44 IP-44 terminal box IP-55 IP-55 IP-55 IP-55 Comply with ERP 218 218 218 216 YE/GN PE Protective earth Wiring diagram No. 1 Wiring diagram No. 2 BK N N RD BN C RD L L PE, L1, N - line voltage C - capacitor TK TK TK - jumper BU YE/GN PE Protective earth BN N N RD BU C RD L L PE, L1, N - line voltage C - capacitor BK TK TK TK - jumper YE/GN - yellow/green BK - black RD - red BN - brown BU - blue The company reserves the right to make changes of technical data without prior notice 27