Product Data Sheet 8412 NHU-519

Similar documents
Product Data Sheet 3214 JH3-195

Product Data Sheet 632 NU-006

Product Data Sheet DV5214 NU

Product Data Sheet 8412 N/ The engineer's choice

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 8414 NGH

Product Data Sheet 4184 NXHH

Product Data Sheet 4184 N/17X. The engineer's choice

Product Data Sheet 4184 NXHH

Product Data Sheet 4414/2H

Product Data Sheet 4184 NGX

product specification

Product Data Sheet DV4118 N

Product Data Sheet 8314 HR-197

Product Data Sheet ACi 4420 MLR

4314/17T. Product Data Sheet INDEX

Product Data Sheet ACi 4420 HHR

Product Data Sheet 3214 J/2H3F-191

AC centrifugal fan. backward curved

AC axial fan. blades with special design (K series) with guard grille for full nozzle

AC centrifugal fan. backward curved

Immersion Pumps PS and PSL ( Slurp Pump ) sealless

AC axial fan. sickled blades (S series) with full square nozzle

AC centrifugal fan. forward curved, dual inlet with housing (flange)

AC centrifugal fan. forward curved, dual inlet with housing (flange)

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

PART NO: FD2460-C0151E2AL CUSTOMER APPROVAL

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

General_technical_data Series

AC axial fan. sickled blades (S series)

AC axial fan. sickled blades (S series)

AC centrifugal fan - RadiCal

AC centrifugal module - RadiCal

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

AC axial fan. sickled blades (S series) with guard grille for full nozzle

Immersion Pumps PMS and PMS-T sealless

Energy-saving motors (ESM)

PART NO: FD1212-A2251G2AL. DATE : June 9, 2010 CUSTOMER APPROVAL

AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

Power consumption In operation At rest For wire sizing. Functional data Torque Motor Spring return. Rated impulse voltage Control pollution degree 3

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

CUSTOMER: ARCERA EU MODEL NO: 5115 (CeraDyna Fan) PART NO: FW2451-A1051C2AL DATE: CUSTOMER APPROVAL. Taiwan

AC centrifugal fan with housing (small flange)

AC axial fan. straight blades (A series) with full round nozzle

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

AC axial fan. sickled blades (S series) Wall ring with guard grille

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

Actuators for air dampers and control valves of oil burners

Immersion Pumps PRG sealless

A22NK. Key-type Selector Switches

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Model Number Structure

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

Information. DC axial fans. DC axial fans. DC axial fan overview 27 DC axial fan / DC diagonal fan

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Standard cylinders DDPC, with measured-value transducer DADE

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

General_technical_data Series

Table of contents. Three-phase asynchronous motors DA

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

FBA08A (80 X 25.5 L )

SITESTAR ELECTRONICS CABINET DESCRIPTION

DC/DC converters - MINI-PS DC/ 5-15DC/

Model Number Structure

3 Phase Power Systems - Designed for Canada

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

General_technical_data Series

Unobox units with backward curved centrifugal impellers

Application Mini Contactors for Motors and Resistive Loads

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

MB Series AC Centrifugal Blowers

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

BPF. Centrifugal Plug Fans

M Series 010.D Data Sheet. Analog Meters with Moving-Coil Movement, 90 Dial PSQ 48 PQ 72 RS PQ 96 RS PQ 144 RS

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

Centrifugal pumps. Main catalogue.

400ºC/2h and 300ºC/2h roof-mounted helical extractor fans with vertical air outlet

Actuators for Air and Gas Dampers

Electric Immersion Pumps PRT and PRA, sealless

Safety Interlock Switches

SM 1231 ANALOGINPUT MODULE

Overview of types. Technical data

For air dampers and control valves of oil or gas burners

Solenoid Valves Type 3963

Multifunctional 400ºC/2h and 300ºC/2h roof fans

Model Number Structure

Transcription:

The engineer's choice

8412 NHU-519 INDEX 1 General... 3 2 Mechanics... 3 2.1 General... 3 2.2 Connections... 3 3 Operating Data... 4 3.1 Operating Data - Electrical Interface - Input... 4 3.2 Electrical Operating Data... 5 3.3 Operating Data - Electrical Interface -Output... 5 3.4 Electrical Features... 5 3.5 Aerodynamic... 7 3.6 Sound Data... 8 4 Environment... 8 4.1 General... 8 4.2 Climatic requirements*)... 8 5 Safety... 9 5.1 Electrical Safety... 9 5.2 Approval Tests... 9 6 Reliability... 9 6.1 General... 9 12/19/2014 page 2 of 10

1 General Fan type Rotational direction looking at rotor Airflow direction Bearing system Mounting position Fan counterclockwise Air outlet over struts Ball bearing any 2 Mechanics 2.1 General Width Height Depth Weight Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 80,0 mm 80,0 mm 25,4 mm 0,095 kg Plastic Plastic wire outlet corner: 50 Ncm remaining corners: 70 Ncm ISO 4762 - M4 degreased, without an additional brace and without washer 2.2 Connections Electrical connection Wires - Plug Length of lead wire L = 100 mm Tolerance Length of tube S = 75 mm Tolerance Wire gauge (AWG) 24 Insulation diameter 1,55 mm Conector + Contact see drawing +- 10,0 mm Colour Operation Wire 1 red + UB Wire 2 blue - GND 12/19/2014 page 3 of 10

3 Operating Data 3.1 Operating Data - Electrical Interface - Input Control input None 12/19/2014 page 4 of 10

3.2 Electrical Operating Data Measurement conditions: Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; Motor axis horizontal;warm-up time before measuring 5 minutes (unless otherwise specified).in the intake and outlet area should not be any solid obstruction within 0,5 m. p = 0: corresp. to free air flow (see section 3.5) I: corresp. to arithm. mean current value Features Condition Symbol Values Voltage range p = 0 U 8,0 V 13,2 V Nominal voltage p = 0 U N 12,0 V Power consumption p = 0 0,8 W 2,1 W 2,7 W P +- 17,5 % +- 12,5 % +- 15,0 % Tolerance 0001 Current consumption p = 0 97 ma 177 ma 204 ma I +- 17,5 % +- 12,5 % +- 15,0 % Tolerance 0001 Speed p = 0 2.350 1/min 3.600 1/min 3.900 1/min n +- 12,5 % +- 7,5 % +- 10,0 % Tolerance Starting current consumption 0001 3.3 Operating Data - Electrical Interface -Output 910 ma Tacho type None Alarm type None 3.4 Electrical Features Electronic function Reversed polarity protection Max. residual current at Un Locked rotor protection Locked rotor current at Un Clock signal t3/t4 at locked rotor None Rectifying diode IF <= 5 ua Auto restart approx. 910 ma Typical: 0,2 s / 1,1 s t3: 0,06 s... 0,77 s t4: 0,3 s... 3,6 s 12/19/2014 page 5 of 10

12/19/2014 page 6 of 10

3.5 Aerodynamic Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23 C +/- 3 C; In the intake and outlet area should not be any solid obstruction within 0,5 m. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions. a.) Operation condition: 3.600 1/min at free air flow Max. free-air flow ( p = 0 / = max.) 78,0 m3/h Max. static pressure ( p = max. / =0) 58 Pa 12/19/2014 page 7 of 10

3.6 Sound Data Measurement conditions: Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 db(a) For further measurement conditions see section 3.5 a.) Operation condition: 3.600 1/min at free air flow Optimal operating point Sound power level at the optimal operating point Sound pressure level at free air flow, measured in rubber bands 64,0 m3/h @ 14 Pa 5,0 bel(a) 37,0 db(a) 4 Environment 4.1 General Min. permitted ambient temperature TU min. -20 C Max. permitted ambient temperature TU max. 70 C Min. permitted storage temperature TL min. -40 C Max. permitted storage temperature TL max. 70 C 4.2 Climatic requirements*) IP-protection type (certified) IP 68 (for fan only, not for connector if applicable) **) Humidity requirements humid temperature, cyclic; according to DIN EN 60068-2-38, 10 cycle and condensation water check; according to DIN EN ISO 6270-2, 14 days Salt fog requirements None *) Permittet application area: The product is for the use in partial sheltered rooms or open, roofed areas. Direct exposure to water is allowed provided that this does not prevent the normal operation. Saline ambient conditions must be avoided. Pollution degree 3 (according DIN EN 60664-1) It occurs conductive pollution or dry non-conductive pollution which becomes conductive due to condensation. **) The specification of the IP protection refers to the conditions mentioned in certification of the fan. The above mentioned short description of the protection scope is not final. For detailed information of the respective protection scope and definitions, see certification as well as DIN EN 60529 (protection by housings) and ISO 20653 (for vehicles) with the letter K. 12/19/2014 page 8 of 10

5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25 C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H. and 25 C measured with U=500 VDC for 1 min. clearance / creepage distance Protection class Not applicable Not applicable RI > 10 MOhm 1,0 mm / 1,2 mm III 5.2 Approval Tests CE EC Declaration of Conformity Yes EAC Eurasian Conformity Yes UL Underwriters Laboratories Yes VDE Association for Electrical, Electronic and Information Technologies Yes CSA Canadian Standards Association Yes CCC China Compulsory Certification No The approval tests are observed to: U approval max.:13,2 V @ TU approval max.: 70,0 C 6 Reliability 6.1 General Life expectancy L10 at TU = 40 C Life expectancy L10 at TU max. 70.000 h 35.000 h 12/19/2014 page 9 of 10