The UL Type 3R Package is specifically designed for Adjustable Frequency Drives, such as Yaskawa's E7, F7, G7, P7, and iqpump models.

Similar documents
Dual ground lug - one lug for earth ground, one lug for utility ground.

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

14x12x7 Inch 48 VDC (PoE) Power-Over-Ethernet Powered, Weatherproof & Insulated with Heating System - Model: NB H0N

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

Specification Number: Product Name: GROUP MOUNTED MAIN FUSIBLE SWITCH, GROUP MOUNTED BRANCH FUSIBLE SWITCH (LONG) SECTION

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

Westell Boxer BXM HE Outdoor Cabinet with 48VDC 1,800 Watt Heat Exchanger

M-2900A Tapchanger Control Cabinet

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

TECHNICAL SPECIFICATIONS for. Telecommunication Battery Backup Systems (TBS)

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES

SECTION ENCLOSED CONTROLLERS

Type 4 Panel Enclosures

GRANITE ENCLOSURES MODEL NO. NPS Standard Features

Switchgear Skid, C1192

Temperature Transmitters

SUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

The TeleControl Series Technical Drawings

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

Contents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Contents. Burner Components. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Steel Enclosures Contents

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

MP Meter-Pak Meter Centers

The Ex-Cell-I series is made for instrumentation with easy access central locking system and hinged cover.

RSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English

EQUIPMENT PROTECTION

Phone: Fax: Web: -

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Digital High Volume Ambient Air Monitoring Systems 110 Volt

Westell Boxer BXM1019 NHE3 & BXM1019 NHE3G Outdoor Cabinets with 24VDC/ 48VDC Heat Exchanger

BAC Custom Engineered Controls

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

ACCESSORIES Electric Heater Compact Cooling Fans Floor Stand Kit PANELITE Enclosure Lights BULLETIN: A28SX

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

GE 8000-Line Motor Control Centers

Commercial Boxes and Enclosures COM-24 COM-66

OUR VISION STAINLESS STEEL MILD STEEL MODULAR FLOOR STANDING NON METALLIC P F BLACKBURN SOUTH VIC 3130

PROJ. NO SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

CABINET OPTIONS AND DESIGNATORS CODE LETTERS

Wallmount EnclosurEs smart DEsign superior protection

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators


Generator Fire Safety: Generator assemblies should be located outside the building.

SAV Electronic Valve Actuator

Boxer BXM05V19 NMT Sealed Outdoor Cabinet with Vertical 5 RU Rack

Standard Product. Wall-Mount Cabinets ULTRX Fiberglass Type 4X WiFi Cabinet and Accessories

RMR Floor-Mount Enclosures

Industrial Generator Set Accessories

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)

C13 / C15 / C18 SOUND ATTENUATED ENCLOSURES

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

Product Data For FARNELL

C13/C15/C18 Sound Attenuated Enclosures. Features. Enclosures. U.S. Sourced Diesel Generator Set kw 60 Hz

IP44 - IP66 Rated RCD, Power & Cable Management

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

SECTION METAL LOCKERS. A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

483 mm (19 ) Wall Mounting Cabinets IP55 (Outdoor), 600 mm width mm, 600 mm depth

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

Options. Meter base. Cooling Up fan to 22 kaic rated breakers SERVICE

Features/Specifications FRONT VIEW (COVERS REMOVED)

A. Submit manufacturer's literature and technical data before starting work.

10. METERING General Requirements

AMENDMENT ELECTRIC SERVICE MANUAL 2014

High Performance Vector Control Drive Manual Supplement

User s Manual. ACS550-PC/PD Packaged Drive with Disconnect Supplement to ACS550-01/U1 User s Manual

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

2904 Power Supply Installation Instructions I-EA00041

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

SECTION MOTOR CONTROL

Specialty Products SHELVES CPU SOLUTIONS. CPU SideRack. Anthro04_pricelist_standard_specialty.qxd 5/22/ :32 AM Page 36 ADJUSTABLE LAPTOP CART

New Plexo 3, all the space you need

Technical Manual. DLM Module. This manual should remain with the unit.

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

PH (763) FX (763) hoffmanonline.com

NETXTEND FLEX SERIES Equipment Enclosures

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

Air Conditioning Disconnects

SUPPLEMENT MANUAL IM250. AQUAVAR CPC - FD Variable Speed Drive with Fused Disconnect SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

Weather Protective Devices

ALTIVAR FLEX58 Chassis Drive Controller Product Selection

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

SECTION PANELBOARDS

Rzr Heater System Part #

Ice Rink Renovation & New Clubhouse

Explosionproof enclosures XPCJ series Cast aluminum steel control/junction box

Two Seas Metalworks Shell Lane fax Rev

TRAFFIC AND PARKING SYSTEMS SPIKES, BARRIER GATES AND COMPONENTS

IP65/IP66 ABS/Polycarbonate Screw Lid Boxes

POWERPLEX PANELBOARD 1

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

Transcription:

The UL Type 3R Package is specifically designed for Adjustable Frequency Drives, such as Yaskawa's E7, F7, G7, P7, and iqpump models. A new benchmark for performance, benefits and quality, the UL Type 3R Package includes numerous built-in features to accommodate outdoor installations. Dual ground lug - one lug for earth ground, one lug for utility ground. Standard practice in the Yaskawa UL Type 3R Package is to provide filter media at enclosure exhaust ports. The filter media brackets include integral filter supports as highlighted in red below. The UL Type 3R Package is designed for applications such as Cooling Towers, Rooftop AHUs or Exhaust Fans, Irrigation Pumps and Water/Wastewater Pumps. Designed to operate in ambient temperatures up to 104 o F without air conditioning with space for several commonly used options, makes this the preferred outdoor duty package for adjustable frequency drives. Standard Features include: 12 Gauge Steel Construction Integral ¼ Turn Door Latches Padlock Hasp UV / Type 3R Keypad Membrane Powder Coat White Paint Whole Door Gasket Stainless Steel Hardware There are many standard features of the Yaskawa UL Type 3R Package. Inside Left View Meets UL50, File No. E143427, Type 3R for outdoor use to provide a degree of protection against falling rain; undamaged by the formation of ice on the enclosure The areas highlighted in red use the same filter media. This decreases the number of filter media part numbers which lowers cost of ownership. The filter media is easy to replace which lowers the overall maintenance cost of this outdoor duty package. Inside Right View Inside View

Protecting the cabinet cooling fans in an outdoor duty enclosure is a top priority. A screen is provided to go between the fan bracket and the enclosure bottom to prevent small items from damaging the filter media or blocking fan operation. The UL Type 3R Package is designed to operate in a 0 ο F to 104 ο F ambient temperature range. A standard option is a 0 ο F to 122 ο F (50 ο C) ambient temperature range. This UL Type 3R Package is designed to operate at either temperature range without air conditioning due to the thermostatically controlled cabinet cooling fans highlighted in green. Derating the adjustable frequency drive is not required. Inside Bottom View Inside Bottom View Enclosure top flange channels water away from the door gasket to prevent gasket saturation and possible water ingress to internal electrical components. The filter media can be inserted into the fan bracket to protect the UL Type 3R Package from dusty environments. Enclosure Top Flange Cut-a-Way Lift-off door hinges with brass pins provide improved security and weather protection as well as easier access than a traditional piano hinge. Outside Upper Left Corner

Bottom conduit entry is available without predetermined knockouts, to provide an added degree of protection from the weather elements for input power wiring, motor wiring, and control circuits. This configuration provides flexible installation options for the electrician. See recommended conduit entrance area highlighted with blue dashed line. A standard part of the UL Type 3R Package are the integral lifting tabs provided on the side of enclosure to facilitate the physical installation without blocking access to the mounting holes. The bottom mounting holes are slotted to "rest" the UL Type 3R Package on the bottom two bolts until the top two bolts can be aligned. Rain hoods with screens prevent falling rain and small items from entering the exhaust. Inside Bottom View Outside Left View Because of its flush back, the UL Type 3R Package can be mounted to many vertical surfaces, including, but not limited to, concrete or brick wall, cooling tower frame, or fieldconstructed bracket. Rear View

When vertical surfaces are limited, optional leg kits are available for the UL Type 3R Package to become a freestanding installation. An optional 12" Leg Kit or 30" Leg Kit is available as shown below. 12 Leg Kit The following are UL Type 3R package options: Service Entrance Rated Disconnect Space Heater with Thermostat - maintains the internal cabinet temperature to reduce condensation NEC branch circuit protection device for input power with flange-mounted operating handle (as shown below) Surge Suppressor - adds a degree of protection to the UL Type 3R Package from transient surges coming through the power line cables. Lightning strikes are the most common source of surges Custom Engraved Nameplates - white lettering on black lamicoid is available Drive Keypad Internal - the digital drive keypad will be mounted inside the UL Type 3R Package on the Adjustable Frequency Drive Drive Keypad Viewing Window - the digital drive keypad is mounted on the outside of the UL Type 3R Package door. This option provides a viewing window which is hinged and lockable 30 Leg Kit Service Entrance Rated Disconnect

Yaskawa Electric America, Inc. 2121 Norman Drive South Waukegan, IL 60085 800-YASKAWA (927-5292) Fax: 847-887-7310 DrivesHelpDesk@yaskawa.com Bulletin BL.N3R.01 2008 Yaskawa Electric America, Inc. 12/01/08