TOSVERT VF-AS1/PS1. PROFIBUS-DP Option Instruction Manual PDP002Z

Similar documents
VF-S11 RS485 built-in board option RS4003Z Instruction Manual

I. Safety precautions

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

Extended Panel Operation Manual RKP001Z-0

Braking unit Option Instruction Manual PB7-4132K

Lumitester PD-20 Control Kit

1. Inspection and Maintenance

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

TOD-BCU-PNUS2. User's Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System)

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

INSTRUCTION MANUAL. Braking Resistor

Uninterruptible Power System

OPERATION MANUAL, POWER MODULE-CHARGER SYSTEM. Man Occup. Machine Occup. Cycle Time Setup Time Batch Qty. Equipment Manufacturer Qty

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

DIGITAL TORQUE GAUGE MODEL BTGE-G

PowerOhm Installation Manual for LG ATV Series Braking Modules

c-go 24V/6A 24V/8A 24V/12A

CX-SERIES ADVANCED BATTERY CHARGER

Industrial Inverter (For 3-phase motors)

Uninterruptible Power System

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Wind Power Inverter WINDY BOY 5000A/6000A

Service instructions. MAGNA Series 2000

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

UE-MINI HYDRO BOOSTER SYSTEM

B297SB-01-1K40. AnyWireASLINK System Product Guide. ASLINKSENSOR [Photo Interrupter type] -B297SB011K40 1/7- [Function] [Notes on Safety]

Cat. No. I159E-EN-01. SCARA Robots ZX-T XG Series. R6Y - XGC/XGP series MAINTENANCE MANUAL

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

VM-5 SERIES MONITOR MODEL VM-5Z3 POWER SUPPLY UNIT INSTRUCTION MANUAL

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Installation Instructions

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

PowerOhm Installation Manual for BM R Series Braking Modules

Freedom egen System End-of- Line Functional Checklist

Battery Unit BHM60PC/BHM100PC Instruction Manual

User Manual Solar Charge Controller 3KW

OPERATOR S MANUAL SINGLE PORT UNIVERSAL CAR CHARGER

XeVision XeRay XV-LX50 HID Searchlight

Installation and Operation Back-UPS BX550CI-CN

Power Meter INSTRUCTION MANUAL. Model Number: AESPP AUS

Lithium-Ion Phosphate Battery US2000(Version B) Product Manual

Uninterruptible Power System

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

KeContact P20. User manual

This section is specifically about safety matters

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Safety Precaution. Notation. Meaning of symbols WARNING CAUTION

EVS RP6020. Instruction Manual

SERVO-TOP II ELECTRONIC ACTUATOR

VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY

Air Conditioner. Installation manual. Wired remote controller MWR-WE11N

Filterpack FR-BFP2-(H)0.4K to (H)15K

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Differential Pressure Transmitter

PV Generation System. Solar Charge Controller SPECIFICATION

Propane torch. Model Assembly And Operation Instructions

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

(R86049) WARNING: To reduce the risk of injury, the user must read and understand the operator s manual before using this product.

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

SERVICE MANUAL AIR CONDITIONER (SPLIT TYPE) RAS-M10PKVP-E RAS-M13PKVP-E RAS-M16PKVP-E RAS-M18PKVP-E RAS-3M26UAV-E. FILE No. A

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

POWER REGULATOR LD -40PSU

Instruction Manual for Safety and Comfort

Installation and Operation Manual Back-UPS BX1100CI-CN

V1.0. Showven Technologies Co.,Ltd.

TOSHIBA Thermal Printer B-852-R SERIES. Maintenance Manual. Document No. EO Original Mar., 2006 (Revised ) PRINTED IN JAPAN

3.3kWh Battery Pack Specification 3.3

Installation and Operating Instructions. Solar System Controller ISC3020

GAN Electronic 600W/750W SE US

Series 905-IV16(E) CAN/CANopen Input Modules Installation and Operating Manual

HIB Enclosed Inverter User Guide

AUTOMOTIVE EMISSON ANALYZER QRO OPERATING MANUAL QROTECH CO., LTD.

FX2N-2LC SPECIAL FUNCTION BLOCK

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

English. Instruction and operation manual S 212. Dew point sensor

MEDO LA BLOWER INSTRUCTION MANUAL INSTALLATION & MAINTENANCE LA-28B/ LA-45B LA-60B/ LA-80B LA-100/ LA-120

System 3 ZB1PS Device Chassis. Operator s Manual

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

SIZING OF SOLAR GENERATOR

Galaxy Receiving and Unpacking 09/

LIPOZET-Plus (MT-750S)

400 Watt Backup Power System Owner s Manual

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

Installation Manual. Remote Temperature Sensor KS9-BS1-A. Instructions for :- Remote Temperature Sensor

GATE VALVES. Type P (Standard: Plug) Type S (Soft Seal) Contents. (1) Be sure to read the following warranty clauses of our product 1

B-RAD Select USER MANUAL TABLE OF CONTENTS

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Installation, Maintenance and Warranty Flat Plate Battery

Combined Ventilation Controller RVWS-T-224HA

Installation Manual. Low Ambient Cooling Kit. ZLABKA01A Low Ambient Cooling Kit. ZLABKA02A Low Ambient Cooling Kit

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Read and understand this manual for safely usage.

Technical Information Manual

Transcription:

TOSVERT VF-AS1/PS1 PROFIBUS-DP Option Instruction Manual PDP002Z Notice 1. Make sure that this instruction manual is delivered to the end user of the PROFIBUS option for the VF-AS1/PS1. 2. Read this manual before installing or operating the PROFIBUS option for the VF-AS1/PS1. And keep it in a safe place for reference. * The data given in this manual are subject to change without notice. Toshiba Schneider Inverter Corporation 2005 All rights reserved.

Safety precautions E65812796 On the inverter and in its instruction manual, important information is contained for preventing injuries to users and damages to assets and for proper use of the device. Read the instruction manual attached to VF-AS1/PS1 along with this instruction manual for completely understanding the safety precautions and adhere to the contents of these manuals. Explanation of markings Marking Meaning of marking Warning Indicates that errors in operation may lead to death or serious injury. Indicates that errors in operation may lead to injury (*1) to people or that these errors Caution may cause damage to physical property. (*2) (*1) Such things as injury, burns or shock that will not require hospitalization or long periods of outpatient treatment. (*2) Physical property damage refers to wide-ranging damage to assets and materials. Meanings of symbols Marking Meaning of marking Indicates prohibition (Don't do it). What is prohibited will be described in or near the symbol in either text or picture form. Indicates something mandatory (must be done). What is mandatory will be described in or near the symbol in either text or picture form. Indicates warning. What is warned will be described in or near the symbol in either text or picture form. Indicates caution. What the caution should be applied to will be described in or near the symbol in either text or picture form. - 1 -

General Operation Disassembly prohibited Prohibited Mandatory Warning Never disassemble, modify or repair. Doing so could result in electric shock, fire and injury. For repairs, call your sales agency. Do not attach this option to any inverter other than the VF-AS1/PS1. Doing so could result in electric shock or fire. When the inverter is energized, never detach the this option from the VF-AS1/PS1. Doing so could result in electric shock. Don't place or insert any kind of object into the PDP002Z (electrical wire cuttings, rods, wires). Doing so could result in electric shock or fire. Do not allow water or any other fluid to come in contact with the PDP002Z. Doing so could result in electric shock or fire. Turn off the VF-AS1/PS1 when installing and wiring the terminal block. If the inverter begins to emit smoke or an unusual odor, or unusual sounds, immediately turn power off. If the equipment is continued in operation in such a state, the result may be fire. Call your local sales agency for repairs. Transportation & installation Prohibited Mandatory Warning Do not operate the inverter if it is damaged or any component is missing. Doing so could result in electric shock or fire. Call your local sales agency for repairs. Do not place any inflammable substances near the VF-AS1/PS1 Inverter. If an accident occurs in which flame is emitted, this could lead to fire. Do not install in any location where the inverter could come into contact with water or other fluids. Doing so could result in electric shock or fire. When installing this option, be careful not to touch the leads from parts on the reverse side of its circuit board. Doing so could result in injury. Operate under the environmental conditions prescribed in the instruction manual. Operations under any other conditions may result in malfunction. - 2 -

Wiring Mandatory Warning Shut off power when installing and wiring this option. Wait at least 15 minutes and check to make sure that the charge lamp (VF-AS1/PS1) is no longer lit. Electrical construction work must be done by a qualified expert. Installation or connection of input power by someone who does not have that expert knowledge may result in fire or electric shock. Operations Prohibited Warning Do not touch switches when the hands are wet and do not try to clean the inverter with a damp cloth. Doing so could result in electric shock. Do not pull on any cable itself. Doing so could result in damage or malfunction. Disposal Mandatory Caution For safety's sake, do not dispose of the disused inverter yourself but ask an industrial waste disposal agent (*). If the collection, transport and disposal of industrial waste is done by someone who is not licensed for that job, it is a punishable violation of the law. (Laws in regard to cleaning and processing of waste materials) (*) Persons who specialize in the processing of waste and known as industrial waste product collectors and transporters or industrial waste disposal persons. Notes on use Notes Do not install the inverter where the temperature or the humidity will change rapidly. Keep a distance of 20cm or more between the inverter's power cable and the data transmission cable. Or the inverter might malfunction because of noise. Insert a magnetic contactor or similar device between the inverter and the power supply to ensure that power is turned off if an emergency stop command is entered through the network. - 3 -

Introduction E65812796 Thank you for purchasing a VF-AS1/PS1 PROFIBUS Option (PDP002Z), for TOSVERT VF-AS1/PS1 inverter. Installing this option in the VF-AS1/PS1 and using it together, data communication can be made with a host computer or other device via PROFIBUS DP (DP-V0). Please read the entire manual carefully before attempting to control your inverter via PROFIBUS connection. Besides this instruction manual, the PDP002Z Function Manual is required to develop the software of communication with VF-AS1/PS1. In such a case, please get in touch with our branch offices or sales offices. ( PDP002Z Function Manual : E6581343). This manual is also aimed at the operator using "VF-AS1/PS1 PROFIBUS option", so please use it for future maintenance and inspection. Explanation of model number of PROFIBUS option PDP 002 Z -0 Revision No. Cable length (cable between inverter and unit), Z: No cable PROFIBUS model number PROFIBUS Check of accessories PROFIBUS option is shipped together with the following items in the package. Contact your sales agency if any of these is missing. VF-AS1/PS1 PROFIBUS option... 1 board (PDP002Z) Instruction manual for the VF-AS1/PS1 PROFIBUS option (this manual)... 1 copy (E6581279) Manual LED name label... 1 pcs. - 4 -

Contents 1. OVERVIEW...6 2. EXTERIOR FEATURES...7 2.1. PROFIBUS connector...8 2.2. Status indicator...8 3. INSTALLING THE PDP002Z...9 4. CONNECTING TO THE NETWORK...10 4.1. Installation method...10 4.2. Setting a station address...11 5. COMMUNICATIONS-RELATED PARAMETERS...13 5.1. f851: Communication Loss Action Setting (Network breaks)...14 5.2. f852: Preset speed operation selection...14 5.3. f830: PPO TYPE Setting...15 6. PROFIBUS LOCAL/REMOTE OPERATION...16 7. SPECIFICATIONS...17 8. WARRANTY...17-5 -

1. Overview The PDP002Z option allows the VF-AS1/PS1 inverter to be connected as a slave (DP-V0) into a PROFIBUS network. Up to 126 stations* can be connected to the network (* including a master. If no repeater is provided, up to 32 stations can be connected to each segment). Master (PLC, etc.) PROFIBUS VF-AS1/PS1 PDP002Z VF-AS1/PS1 PDP002Z Repeater Maximum connectable units: 126 (In a case like the one above, PLC is included in the count.) VF-AS1/PS1 PDP002Z - 6 -

2. Exterior features The external view of this option and the name of each part are shown below. Status indicator (Refer to Section 2.2) Panel mounting tabs (Refer to Section 3) Address switch (Refer to Section 4.2) PROFIBUS connector (Refer to Section 2.1) Prohibited Warning Do not change the switch setting when the power is on. It could lead to electric shocks, or the option might breaks down or get damaged. - 7 -

2.1. PROFIBUS connector Used to connect PROFIBUS network cables. The connector is a D-Sub connector with 9 pin female and the connector pin allocation described below follows the PROFIBUS standard. 5 4 3 2 9 8 7 6 1 Pin number Symbol Signal type 1 NC Reserved 2 NC Reserved 3 RxD/TxD-P Send/receive data (+) 4 CNTR-P Control signal 5 DGND 0V (Insulated from the inside) 6 VP +5V power 7 NC Reserved 8 RxD/TxD-N Send/receive data (-) 9 NC Reserved The PDP002Z has no termination resistor. Therefore, termination resistors need to be connected to the station on each side of the PROFIBUS network or the master, as shown in the figure below. (The PROFIBUS connector with termination resistor are recommended.) VP(6 pin) 390 ohm * RxD/TxD-P(3 pin) 220 ohm * RxD/TxD-N(8 pin) 390 ohm * DGND(5 pin) * 1/4W or more is recommended. 2.2. Status indicator The PDP002Z has two LEDs, ST (status) and DX (data exchange) to indicate the statuses of PROFIBUS-DP and the PDP002Z itself. ST (Status): Red LED LED Off Flashes Lights Meanings No diagnostics present Waiting for parameterisation or configuration DP status error * For example, a station address is not set correctly. DX (Data exchange): Green LED. Indicates the status of the PROFIBUS network. It lights when the PDP002Z is on-line and data exchange is possible. - 8 -

3. Installing the PDP002Z Install the PROFIBUS option to VF-AS1/PS1 as follows: * When this option is used together with the IO card option, attach this option to the front panel side. (1) Turn off input power of VF-AS1/PS1 and wait for at least 15 minutes and then check that the CHARGE lamp on VF-AS1/PS1 is no longer lit. (2) Securing the option to the inverter a) Insert a flat-blade screwdriver in each of the two holes at the upper part of the front panel, release the panel mounting tab by pushing the screwdriver down, and remove the front panel cover. b) Install the option in the inverter by fitting the tabs on the lower side of the option into the slots at the lower part of the inverter front panel. c) Make sure the option is securely attached to the inverter. Then, check whether the plastic bosses on the inverter case have fitted in the holes at the upper and lower parts of the option. d) Insert the tabs at the lower part of the front cover into the slots at the lower part of the inverter to attach the front cover to the inverter. e) Stuck the enclosed "LED name label" on the option LED display part of a front cover. a) * When installing this option to below capacities, remove the Add-on type option case. VFAS1: 200V 55, 75kW 400V 90-500kW VFPS1: 200V 55-90kW 400V 90-630kW c) b) d) LED name label e) ST DX MNS MNS MNS - 9 -

4. Connecting to the network 4.1. Installation method (1) Using the DIP switchon the PROFIBUS option, seta station address. (Refer to Section 4.2.) (2) Connect a PROFIBUS connector to the PDP002Z. (Refer to Section 2.1.) * If the PDP002Z is located at an end of the bus, connect a terminal resistor to it. (When using a connector with termination resistor, set it ON.) (3) Once all the parameters are set, the power must be cycled to the VF-AS1/PS1 for these changes to take effect. (Refer to Section 5.) - 10 -

4.2. Setting a station address The DIP switch on the circuit board of the option is used to set a station address. Each DIP switch is ON when it is flipped to the lower position. By default, it is factory-configured to 2. The station address must be unique and not match any other device on the network. 1 2 3 4 5 6 7 8 DIP ON SW ID 1 2 3 4 5 6 7 8 SW ID 1 2 3 4 5 6 7 8 0 OFF OFF OFF OFF OFF OFF OFF OFF 32 OFF OFF ON OFF OFF OFF OFF OFF 1 OFF OFF OFF OFF OFF OFF OFF ON 33 OFF OFF ON OFF OFF OFF OFF ON 2 OFF OFF OFF OFF OFF OFF ON OFF 34 OFF OFF ON OFF OFF OFF ON OFF 3 OFF OFF OFF OFF OFF OFF ON ON 35 OFF OFF ON OFF OFF OFF ON ON 4 OFF OFF OFF OFF OFF ON OFF OFF 36 OFF OFF ON OFF OFF ON OFF OFF 5 OFF OFF OFF OFF OFF ON OFF ON 37 OFF OFF ON OFF OFF ON OFF ON 6 OFF OFF OFF OFF OFF ON ON OFF 38 OFF OFF ON OFF OFF ON ON OFF 7 OFF OFF OFF OFF OFF ON ON ON 39 OFF OFF ON OFF OFF ON ON ON 8 OFF OFF OFF OFF ON OFF OFF OFF 40 OFF OFF ON OFF ON OFF OFF OFF 9 OFF OFF OFF OFF ON OFF OFF ON 41 OFF OFF ON OFF ON OFF OFF ON 10 OFF OFF OFF OFF ON OFF ON OFF 42 OFF OFF ON OFF ON OFF ON OFF 11 OFF OFF OFF OFF ON OFF ON ON 43 OFF OFF ON OFF ON OFF ON ON 12 OFF OFF OFF OFF ON ON OFF OFF 44 OFF OFF ON OFF ON ON OFF OFF 13 OFF OFF OFF OFF ON ON OFF ON 45 OFF OFF ON OFF ON ON OFF ON 14 OFF OFF OFF OFF ON ON ON OFF 46 OFF OFF ON OFF ON ON ON OFF 15 OFF OFF OFF OFF ON ON ON ON 47 OFF OFF ON OFF ON ON ON ON 16 OFF OFF OFF ON OFF OFF OFF OFF 48 OFF OFF ON ON OFF OFF OFF OFF 17 OFF OFF OFF ON OFF OFF OFF ON 49 OFF OFF ON ON OFF OFF OFF ON 18 OFF OFF OFF ON OFF OFF ON OFF 50 OFF OFF ON ON OFF OFF ON OFF 19 OFF OFF OFF ON OFF OFF ON ON 51 OFF OFF ON ON OFF OFF ON ON 20 OFF OFF OFF ON OFF ON OFF OFF 52 OFF OFF ON ON OFF ON OFF OFF 21 OFF OFF OFF ON OFF ON OFF ON 53 OFF OFF ON ON OFF ON OFF ON 22 OFF OFF OFF ON OFF ON ON OFF 54 OFF OFF ON ON OFF ON ON OFF 23 OFF OFF OFF ON OFF ON ON ON 55 OFF OFF ON ON OFF ON ON ON 24 OFF OFF OFF ON ON OFF OFF OFF 56 OFF OFF ON ON ON OFF OFF OFF 25 OFF OFF OFF ON ON OFF OFF ON 57 OFF OFF ON ON ON OFF OFF ON 26 OFF OFF OFF ON ON OFF ON OFF 58 OFF OFF ON ON ON OFF ON OFF 27 OFF OFF OFF ON ON OFF ON ON 59 OFF OFF ON ON ON OFF ON ON 28 OFF OFF OFF ON ON ON OFF OFF 60 OFF OFF ON ON ON ON OFF OFF 29 OFF OFF OFF ON ON ON OFF ON 61 OFF OFF ON ON ON ON OFF ON 30 OFF OFF OFF ON ON ON ON OFF 62 OFF OFF ON ON ON ON ON OFF 31 OFF OFF OFF ON ON ON ON ON 63 OFF OFF ON ON ON ON ON ON - 11 -

SW ID 1 2 3 4 5 6 7 8 SW ID 1 2 3 4 5 6 7 8 64 OFF ON OFF OFF OFF OFF OFF OFF 96 OFF ON ON OFF OFF OFF OFF OFF 65 OFF ON OFF OFF OFF OFF OFF ON 97 OFF ON ON OFF OFF OFF OFF ON 66 OFF ON OFF OFF OFF OFF ON OFF 98 OFF ON ON OFF OFF OFF ON OFF 67 OFF ON OFF OFF OFF OFF ON ON 99 OFF ON ON OFF OFF OFF ON ON 68 OFF ON OFF OFF OFF ON OFF OFF 100 OFF ON ON OFF OFF ON OFF OFF 69 OFF ON OFF OFF OFF ON OFF ON 101 OFF ON ON OFF OFF ON OFF ON 70 OFF ON OFF OFF OFF ON ON OFF 102 OFF ON ON OFF OFF ON ON OFF 71 OFF ON OFF OFF OFF ON ON ON 103 OFF ON ON OFF OFF ON ON ON 72 OFF ON OFF OFF ON OFF OFF OFF 104 OFF ON ON OFF ON OFF OFF OFF 73 OFF ON OFF OFF ON OFF OFF ON 105 OFF ON ON OFF ON OFF OFF ON 74 OFF ON OFF OFF ON OFF ON OFF 106 OFF ON ON OFF ON OFF ON OFF 75 OFF ON OFF OFF ON OFF ON ON 107 OFF ON ON OFF ON OFF ON ON 76 OFF ON OFF OFF ON ON OFF OFF 108 OFF ON ON OFF ON ON OFF OFF 77 OFF ON OFF OFF ON ON OFF ON 109 OFF ON ON OFF ON ON OFF ON 78 OFF ON OFF OFF ON ON ON OFF 110 OFF ON ON OFF ON ON ON OFF 79 OFF ON OFF OFF ON ON ON ON 111 OFF ON ON OFF ON ON ON ON 80 OFF ON OFF ON OFF OFF OFF OFF 112 OFF ON ON ON OFF OFF OFF OFF 81 OFF ON OFF ON OFF OFF OFF ON 113 OFF ON ON ON OFF OFF OFF ON 82 OFF ON OFF ON OFF OFF ON OFF 114 OFF ON ON ON OFF OFF ON OFF 83 OFF ON OFF ON OFF OFF ON ON 115 OFF ON ON ON OFF OFF ON ON 84 OFF ON OFF ON OFF ON OFF OFF 116 OFF ON ON ON OFF ON OFF OFF 85 OFF ON OFF ON OFF ON OFF ON 117 OFF ON ON ON OFF ON OFF ON 86 OFF ON OFF ON OFF ON ON OFF 118 OFF ON ON ON OFF ON ON OFF 87 OFF ON OFF ON OFF ON ON ON 119 OFF ON ON ON OFF ON ON ON 88 OFF ON OFF ON ON OFF OFF OFF 120 OFF ON ON ON ON OFF OFF OFF 89 OFF ON OFF ON ON OFF OFF ON 121 OFF ON ON ON ON OFF OFF ON 90 OFF ON OFF ON ON OFF ON OFF 122 OFF ON ON ON ON OFF ON OFF 91 OFF ON OFF ON ON OFF ON ON 123 OFF ON ON ON ON OFF ON ON 92 OFF ON OFF ON ON ON OFF OFF 124 OFF ON ON ON ON ON OFF OFF 93 OFF ON OFF ON ON ON OFF ON 125 OFF ON ON ON ON ON OFF ON 94 OFF ON OFF ON ON ON ON OFF 126 OFF ON ON ON ON ON ON OFF 95 OFF ON OFF ON ON ON ON ON - 12 -

5. Communications-related parameters E65812796 On the network, the VF-AS1/PS1 (including the PDP002Z) serves as a slave device. Using the parameters listed below, set the slave device on the network and its mode of operation. The GSD files used to configure the PDP002Z can be downloaded from the following web site. VF-AS1 http://www.inverter.co.jp/product/inv/vfas1/pdp/ VF-PS1 http://www.inverter.co.jp/product/inv/vfps1/pdp/ Parameter Function Adjustment range Default setting f830* Communication 0: None 0 option setting 1 (PPO TYPE) 1: PPO TYPE 1 2: PPO TYPE 2 3: PPO TYPE 3 4: PPO TYPE 4 f851 Inverter operation at the communications loss action (Network wire breaks) 0: Stop and break of connection 1: None 2: Deceleration stop 3: Coast stop 4: Emergency stop 5: Preset speed operation command (Operating at the preset speed operation frequency set with f852) 0 f852 Preset speed operation 0: None 0 selection 1 to 15: Preset speed f853 Monitoring of Displays the station address assigned with the 1 communication device station address DIP switch. 0 to 125 f854** Monitoring of communications Displays the network communication speed set with the DIP switch. 0 device s baud rate 0: 12 Mbit/s 1: 6 Mbit/s 2: 3 Mbit/s 3: 1.5 Mbit/s 4: 500 kbit/s 5: 187.5 kbit/s 6: 93.75 kbit/s 7: 45.45 kbit/s 8: 19.2 kbit/s 9: 9.6 kbit/s 255: Disabled * When the parameters are changed, the power must be cycled to the VF-AS1/PS1 for the changes to take effect. ** The baud rate of the PDP002Z is automatically set by configuration a baud rate for the master. *** The version described on the nameplate and the version of PDP002Z displayed by the status monitor is different. Ex.) When the version describe on the nameplate is V10 1, it displays 16.01 in the status monitor.(in the hexadecimal number, it becomes 10.1.) - 13 -

5.1. f851: Communication Loss Action Setting (Network breaks) This parameter sets up the VF-AS1/PS1 response to a loss of communications with the PROFIBUS network. (On some occasions, the master side will need to be configured.) 0: Stop and break of connection The inverter decelerates the motor to a stop and gives the alarm. Commands entered through the network are canceled, and the commands set with parameters cmod and fmod become effective. When communications are restored, the alarm is turned off. 1: None The inverter remains in the state where it was when the problem arose, and it gives the alarm. 2: Deceleration stop The inverter decelerates the motor to a stop and gives the alarm. Commands entered through the network are not canceled. 3: Coast stop The inverter issues a command for a frequency of 0Hz and gives the alarm. Commands entered through the network are not canceled. 4: Emergency stop The error message err8 is displayed. Commands entered through the network are not canceled. When communications are restored, the inverter is not restored to working order and the error message err8 does not disappear until the inverter is reset. 5: Preset speed operation command Refer to Section 5.2 5.2. f852: Preset speed operation selection If the communication loss action (parameter f851) is set to 5 (preset speed command), the VF-AS1/PS1 will run at a preset speed as set up by this parameter in the case of a communication loss (with alarm). Commands entered through the network are not canceled. For example, If the inverter is set as described below, f851 = 5 (preset speed operation command) f852 = 8 (preset speed operation frequency 8) f287 (preset speed operation frequency 8) = 10 (10Hz) Operation is carried out as follows. Network Operation of the VF-AS1/PS1 Normal conditions...operates according to commands entered through the network. communications loss...operates at 10Hz. Restoration...Operates according to commands entered through the network. - 14 -

5.3. f830: PPO TYPE Setting The PPO type of PDP002Z is set up by this parameter. The PROFIBUS-DP protocol uses so-called PPOs (Parameter/Process Data Objects) in cyclic communication. The figures below show the PPO types and configurations that the PDP002Z supports. PKW PZD1 PKE IND PWE STW ZSW PZD PZD2 HSW PZD3 PZD4 PZD5 PZD6 HIW PPO TYPE 1: Octet-String 12 PPO TYPE 2: Octet-String 20 PPO TYPE 3: Octet-String 4 PPO TYPE 4: Octet-String 12 PKW: Parameter ID/value PZD: Process Data, cyclically transferred PKE: Parameter ID (1st and 2nd octet) IND: Sub-index (3rd octet), 4th octet is reserved PWE: Parameter value (5th until 8th octet) STW: Control word HSW: Main setpoint ZSW: Status word HIW: Main actual value * The response time of VF-AS1 to the command of PROFIBUS-DP needs about 10ms. - 15 -

6. PROFIBUS Local/Remote Operation E65812796 The example below shows how to configure the VF-AS1/PS1 for local / remote operation. <Terminal function> F terminal... RUN command R terminal... PROFIBUS/Local (Terminal in this example) switching RR/S4 terminal... Operation frequency command <Wiring> Variable resistor for adjustment 10k ohm PP VF-AS1/PS1 RR/S4 Operation command CCA F SW1 PROFIBUS/Local Switch R SOURCE SINK CC <Parameter setting> cmod (command mode selection) = 0 (terminal board) fmod (frequency setting mode selection 1) = 2 (RR/S4) f112 (input terminal selection 2 (R)) = 48 (PROFIBUS/Local control) <Operation> R-CC terminal open: VF-AS1/PS1 is controlled as slave device of PROFIBUS. R-CC terminal closed: F-CC terminal short to RUN F-CC terminal open to STOP Output frequency is set up by the RR/S4 signal input. - 16 -

7. Specifications Item Model number Technical data Use environments Ambient temperature Storage temperature Relative humidity Vibration Specifications PDP002Z PROFIBUS DP-V0 PPO TYPE: 1 to 4 by No.3.072 Profile for Variable Speed Drives Connector: D-Sub 9 pin female Station address setting: DIP switch Baud rate: 9.6 kbps up to 12Mbps Indoors, an altitude of 3,000m or less, where the product will not be exposed to direct sunlight, corrosive or explosive gases, vapor, coarse particulates including dust, and where there is no grinding fluid or grinding oil nearby -10 to +60 C -25 to +65 C 20 to 93% (no condensation and absence of vapor) 5.9m/s 2 {0.6G} or less (10-55Hz) 8. Warranty Any part of the inverter that proves defective will be repaired free of charge under the following conditions: 1. If and when a trouble occurs on the option unit properly installed and handled within one year of delivery, and if the trouble is clearly attributable to defects inherent in our design and manufacture, the product will be repaired free of charge. 2. This warranty applies only to the option unit. 3. For the following kinds of failure or damage, the repair cost shall be borne by the customer even within the warranty period. 1) Failure or damage caused by improper or incorrect use or handling, or unauthorized repair or modification of the option. 2) Failure or damage caused by the option falling or an accident during transportation after the purchase. 3) Failure or damage caused by fire, salty water or wind, corrosive gas, earthquake, storm or flood, lightning, abnormal voltage supply, or other natural disasters. 4) Damage sustained as a result of the fact that the product was used for any application other than that designated for the PROFIBUS option (circuit board) for the VF-AS1/PS1. 4. If terms and conditions of warranty are otherwise specified, priority is given to them. -- 17E --