MX2040, DYNAMIC SIGNAL CHECKER Instruction Manual

Similar documents
362 Clamp Meter. Users Manual

INTRODUCTION. Specifications. Operating voltage range:

MX Cable Connector Kit Manual Manual for Trimming the Cable and Connecting the Connector to an MX8031 Extension Cable

All specifications and figures are subject to change without notice. Printed in China Instruction Manual

Instruction Manual. Vibration Calibrators VC10 VC11 VC12 VC13

EV Power - A-Series 8 Cell, 16 Cell and 24Cell Chargers Installation & Usage Instructions.

UP100AC INSTRUCTION MANUAL

PPT 802, Proximity Probe Transducer System

Specifications. Operating voltage range:

Intelligent Digital Balance Charger

Product specification

Product specification

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

FIREFIGHTING EQUIPMENT

FIREFIGHTING EQUIPMENT

USER MANUAL MOMENTS COLLECTION

User manual ma Loop Calibrator Jofra macal

User Manual IQ338. We thank you that you have decided to purchase our intelligent charger.

5550 & 5550G MECHANICAL VIBRATION SWITCHES Hazardous Area Installation Manual

XeVision XeRay XV-LX50 HID Searchlight

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

TCM & MAT Data Logger Battery Replacement Instructions

INSTRUCTION MANUAL C SkyRC Technology Co., Ltd Version 1.0

Bioenno 400 Power Pack BPP-M400

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Power Station. by Lithium USER MANUAL

Super Brain 989 The Pinnacle of Performance with Power to Spare User s Manual Model Rectifier Corporation

Product specification

Eddy Current Displacement Transducer Specifications

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Installation & Operation Manual

X2 Ultima Multi-Chemistry, High-Output, Dual-Charger System

Li-ion Button Rechargeable Battery Specification

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

The Efficient Solution for Pipetting up to 100 ml at once! USER'S GUIDE

I. SIM card preparation 3 II. Installation into a vehicle 3. III. Most common issues and their solutions 9 III. Attachments 10

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

Uninterruptible Power System

Lithium Power Supply

UP120AC INSTRUCTION MANUAL

B-RAD Select USER MANUAL TABLE OF CONTENTS

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

M2TECH PALMER POWER STATION LOW NOISE BATTERY POWER SUPPLY/CHARGER USER MANUAL

Elmdene International Ltd

ML DA 1206 DE 3993 (I) ML DA 1206 DE 3993 (II) -16P027_ML_DA_1206_DE_3993-ML_DA_2407_DE_3993_ _DinA6_ indd

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Polymer-Lithium-Ion Cell Charger

Owner skit. Manuale per l installatore Installer s guide Installations- Anweisungen Notice installateur SL2380

1700W Solar Battery Charger Maximum Power Point Tracker

INSTRUCTION MANUAL CAUTION

GENERALITIES TECHNICAL FEATURES

TRICKLE CHARGER MODEL NO: ATC12VB OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS LS0618 ISS 2

WATERFLUX 3070 Quick Start

Eddy Current Displacement Transducer Specifications

Inductive conductivity meter

User Manual.

Visit us at

HST-BL-2830MS & HST-BL-2830MS-USA

MANUAL. Single charger

GEWAS 181 A. Alarm- and protection device Leak-water detector

This user manual prvides the operation, regular maintenance and safety information. Read this user manual carefully before you use

LTX RF LEVEL SENSOR. Instruction Manual

190M. Medical ScopeMeter. Safety Information

Powerterm L120C Single Output PSU/Battery Chargers Model C2199A-1 (12V/8A) or Model C2199A-2 (24V/6A)

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1061A LINEAR LI-ION BATTERY CHARGER WITH DUAL SYNCHRONOUS BUCK REGULATOR

Compliance with API Standard 670 the PRO Product Standard for Proximity Probes

LIGHT AND POWER SOURCES POWER SOURCES

An Impedance-Based BMS to Identify Bad Cells Rengaswamy Srini Srinivasan Bliss G. Carkhuff

Intelligent NiMH/NiCd/Li-ion Charger TN456

Emergency lighting units EM LED Light Engines

4 - SETTING UP THE MACROMAN CHARGING POSITION 4 Wall mounted 4 Workbench set-up 4

Inductive conductivity meter

SEPTIC FLUID SUCTION PUMP MEDAP-VENTA MC 16 / MC 26 / CC 16 / CC 26

Sectional and Tilting Door Opener Installation Instructions and User Guide

MODEL AP/W HIGH VOLTAGE HOLIDAY DETECTOR (NEW PRODUCT RELEASE 2015)

Rotary Inclinometer III

OutdoorXUPS-600AHV-8364

Experimental Question 1: Levitation of Conductors in an Oscillating Magnetic Field

Mini-Roto TM Paddle Wheel Installation & Operation Manual

FOR YOUR PERMANENT FILE

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

BASIC ELECTRICAL MEASUREMENTS By David Navone

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

METEOROLOGICAL INSTRUMENTS

Caution Wear protective glasses and turn your face away when connecting or disconnecting from the battery.

METEOROLOGICAL INSTRUMENTS

AFTER SALES SUPPORT MODEL NUMBER: 45682

Introduction Charger Layout Special Features Warnings and Safety Information Default User Preferences Setup...

INSTRUCTION MANUAL SPECIFICATIONS:

HPP1 MK5 Owner s Manual

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

All specifications and figures are subject to change without notice.

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

CONTENTS DIVERSE. Preface SQUEEZE ANALYSER SQA2 RESISTANCE WELDING FORCE MONITOR. Resistance Welding. Squeeze Analyser OPERATING INSTRUCTIONS

BOOK LIGHT MUSIC STAND LIGHT USER S MANUAL

ATEX II 2G Ex ib IIC T4 Gb. ATEX II 2D Ex ib IIIC T150 C Db ATEXBEAM

EM DC Multi-Function DC Energy Meter

Ballistic Battery Management System: Professional Intelligent Digital Balance Charger Instruction Sheet

Transcription:

MX2040, DYNAMIC SIGNAL CHECKER Instruction Manual CONTENTS 1 Warnings 2 Scope of Delivery (ordering code KS04) 3 Technical Data 3.1 Handheld Control Unit 3.2 Vibration Simulator 4 Description of Test Procedure 4.1 General 4.2 Vibration Amplitudes 4.3 Test Setup 4.4 Test Procedure 4.5 Vibration Indication 5 Rechargeable Battery 6 Environmental Information 1. Warnings The instruction manual is an integral part of the product. Please read the instruction manual carefully before using the product, and keep it available for future reference. The measuring system should only be operated by qualified personnel who have read this instruction manual. In case of doubt, the prevailing conditions of the area of application and the resulting requirements have to be examined by an expert before operation can be commenced. Correct transportation, appropriate storage and professional assembly, operation and maintenance must be provided in order to ensure proper functioning. Safety instructions concerning the battery can be found under section 5 on page 5 of this manual. 2. Scope of Delivery (ordering code MX2040-001) Handheld control unit with battery Vibration simulator Battery charger with charging cable Instruction manual 3. Technical Data 3.1 Handheld Control Unit The device has to be fully charged before the first operation. In order to do this, connect the power adapter to the control unit with the aid of the charging cable. When the device is fully charged, the charge indicator lamp goes off. The battery should always be charged when storing the device over longer periods of time. When the battery is discharged, the simulation unit can be operated via the provided USB power adapter. Doc# 100911 REV B (May 2016)

3. Technical Data (cont.) Dimensions: 98 x 64 x 40 mm Weight: 150 g (5.2 oz) w/o battery Protective class: IP 54 Battery: 3.7 volt 1000 mah LiPoly battery Charging socket: USB Mini-B Socket for connection to vibration simulator Stored settings of vibration amplitudes UP STATUS DOWN NEXT STORE Charge indicator 3.2 Vibration Simulation Material: Weight: Cable: Dimensions: Probe mounting: stainless steel / aluminum approx 2 kg (4.4 lbs) Coaxial cab, PVC coating 94 mm x Ø 90 mm Prism holder for D = 8 22 mm, M6 locating screw USB charging socket Probe clamped in prism holder GAP adjusting ring M36 x 1 Lock ring M36 x 1 Housing upper part 4. DESCRIPTION OF TEST PROCEDURE Housing lower part 4.1 General Rotor or shaft vibrations are usually measured by means of non-contact eddy-current displacement probes. You measure the relative motion between rotor and the installed probe. With the Dynamic Signal Checker the functionality of such systems can be tested on the basis of realistic simulations of vibrations. The Dynamic Signal Checker consists of a compact housing which contains an electrically driven vibrator. After the probe to be tested is clamped in the prism holder, use the GAP adjustment ring to obtain the necessary voltage (typically 8 to 10 VDC). In combination with the compact, battery driven, handheld control unit the checker can be set into defined oscillations with 112 Hz and different amplitudes. With this, the Dynamic Signal Checker enables a function test of the entire loop (that is the probe, driver/transmitter function, wiring, indications and alarms) in one step. The battery-powered handheld control unit can be attached comfortably by means of the magnet on the back of the device. The rechargeable batteries enable operation up to several hours. Doc# 100911 REV B (May 2016) Page 2 of 8

4.2 Vibration Amplitudes After having determined the loop sensitivity (probe, cable, driver/transmitter) by means of a suitable static calibration unit (e.g. the 9060-001) and a calibrated voltmeter, the Dynamic Signal Checker vibration amplitudes can be simulated precisely. The accuracy of the simulation goes hand-in-hand with the accuracy of the used voltmeter. With this, the complete system (probe, driver/transmitter function, wiring, indications, alarms) gets tested. Basic description of the measuring principle: The Dynamic Signal Checker creates a clean sinusoidal signal with constant frequency (112 Hz) and variable amplitude, which is picked up by the proximity probe. At the buffered-out of the driver/ transmitter or monitor this vibration can be measured as RMS value by means of a common voltmeter set to AC. This RMS value can be converted accurately into a peak to peak value, using following formula: Example: Reading buffered-out: 0.2263 VAC = 226.3 mv AC Typical sensitivity: 7.87 mv/µm (200mV/mil) Vibration amplitude [µpp]: 226.3 * 2 * 1.414 / 7.87 = 81.3µm pp, 226.3 * 2 * 1.454/200 = 3.2 mils pp Simplified formula for the typical measuring loop sensitivity of 7.87 mv/µm (200mV/mil): Spp [µm] = 0.359 * RMS [mv] Spp [mils] = 0.0141 * RMS [mv] As alternative to this calculating procedure, correspondingly calculated values can be taken from the following table or diagram Vibration Vibration Vibration mv RMS µ - pp mils -pp 0 0 0.0 20 7 0.3 40 14 0.6 60 22 0.8 80 29 1.1 100 36 1.4 120 43 1.7 140 50 2.0 160 57 2.3 180 65 2.5 200 72 2.8 220 79 3.1 240 86 3.4 260 93 3.7 280 101 3.9 300 108 4.2 320 115 4.5 340 122 4.8 360 129 5.1 380 137 5.4 Conversion Table Valid for 7.87 mv/µm (200 mv/mil) Vibration Vibration Vibration mv RMS µ - pp mils -pp 400 144 5.6 420 151 5.9 440 158 6.2 460 165 6.5 480 172 6.8 500 180 7.1 520 187 7.3 540 194 7.6 560 201 7.9 580 208 8.2 600 216 8.5 620 223 8.7 640 230 9.0 660 237 9.3 680 244 9.6 700 252 9.9 720 259 10.2 Doc# 100911 REV B (May 2016) Page 3 of 8

Conversion mv AC peak to peak [µm or mils] 5.6 4.8 140 120 vibration (mils-pp) 4.0 100 3.2 2.4 1.6 vibration (µm-pp) 80 60 40 0.8 20 0 0 0 50 100 150 200 250 300 350 400 vibration [mv AC] 4 mv/µ 8 mv/ u10 mv/µ 10.4 260 Conversion mv AC peak to peak [µm or mils] 9.6 240 vibration (mils-pp) 8.8 220 8.0 7.2 6.4 vibration (µm-pp) 200 180 160 5.6 4.8 4.0 140 120 100 100 150 200 250 300 350 400 450 500 550 600 650 700 vibration [mv AC] 4 mv/µ 8 mv/u 10 mv/µ -100mV/mil 200 mv/mil 250 mv/mil Doc# 100911 REV B (May 2016) Page 4 of 8

LoopChecker µm-pp or mils pp ~ mv AC vibration monitor or PLC for threshold monitoring conversion table mv µm-pp or mils pp mils, pp µ-pp mv AC 0.8 20 57 1.6 40 114 - - - - - - 10.2 260 742 indication of measuring values in the control room Doc# 100911 REV B (May 2016) Page 5 of 8

4.4 Test Procedure 1. Before the dynamic test with the Dynamic Signal Checker the measuring loop sensitivity has to be determined, since deviations from the specified sensitivity influence the accuracy and indication. Using a static calibrating unit like the METRIX 9600-001 and a calibrated voltmeter you can verify that probe, cable and driver match the specification (typically: 7.87 V/mm, 200mV/mil). 2. Place the Dynamic Signal Checker on a solid surface. 3. Screw the GAP adjusting ring + lock ring up to about 1 mm into the upper part of the housing. 4. Connect probe including extension cable with driver/transmitter. 5. Connect the voltmeter with the driver/transmitter. Set the voltmeter on DC in order to read out the GAP voltage. 6. Carefully insert the probe or the probe holder with reverse-mount probe, into the GAP adjustment ring and clamp it in the prism holder at a gap signal of about 10 VDC. Avoid contact with the vibrator in order to not damage vibrator or probe tip. Fine adjustment can be achieved by turning of the adjusting ring; then fix it with the lock ring. The prism holder is suitable for probe diameters of 8 22 mm. 7. Connect the simulation unit to the handheld control unit. 8. After pressing the ON/OFF ( ) button once, the device performs a self-test (flashing of all 5 LEDs). As soon as the ON status indicator lights up, the device is ready for operation. 9. By further pressing of the button one by one up to 4 stored default amplitude values (see 11. for adjustment) can be selected. The amplitude can be read from the voltmeter as RMS voltage signal [mv] and converted to [µm pp, mils pp] via calculation formula (p. 4), conversion table (p. 5) or diagram (p. 6). 10. If the vibration indicated in the control room doesn t correspond with the mv signal of the voltmeter, this may be due to one of the following causes: The wiring of the measuring loop is not correct or even broken. The vibration driver/transmitter is defective or calibrated with a wrong measuring range. The limit monitoring in the PLC downstream of the transmitter is calibrated with a wrong measuring range. The input card of the vibration monitor is defective or falsely adjusted, thus a wrong value is transferred to the monitor. The measuring range of the vibration indication is falsely adjusted. 11. In order to adjust individual default values (possible within the range of 0 250 µm, 0 to 10 mils) following steps are necessary: Connect a calibrated voltmeter to the buffered-out of the existing driver/transmitter or monitor and set it to VAC. Read the corresponding mv value of the desired vibration amplitude from the table (p. 4) or diagram (p. 5). Adjust the vibration amplitude according to the mv value by means of pushing the buttons resp.. You can choose between holding the buttons (fast change of values) or just tapping the buttons (slow change of values for rather sensitive adjustment). The adjusted value is to be compared with the operation indications. 4.4 Test Procedure In order to save the individually adjusted value, as shortcut level for future adjustments, select one of the 4 storage positions (green LEDs) with the button. By pressing of the button S the stored value will be replaced by the new selected value. Note that, depending on the battery status (14.) and the position (2.) of the Dynamic Signal Checker the actual amplitude corresponding to the stored values may slightly differ over time. The correct setting can be updated anytime. 12. In order to switch the device off manually, the ON/OFF ( ) button has to be pressed for > 2 seconds. If no operation is performed over a period > 30 minutes, the device switches off automatically. 13. If the ON indicator blinks, the device has to be charged. Before damaging exhaustive discharge starts, the device is automatically switched off; 5 seconds ahead all LEDs start blinking. 14. In case of low battery the device can be powered using the USB charging cable. Doc# 100911 REV B (May 2016) Page 6 of 8

5. RECHARGEABLE BATTERY In order to charge the device, connect the charging socket with the provided USB power adapter. As soon as the battery has reached its full capacity, the charge indicator lamp goes off. The battery should always be charged when storing the device for longer periods of time. SAFETY INSTRUCTIONS FOR LITHIUM ION POLYMER BATTERIES (LiPoly batteries) LiPoly batteries are rechargeable accumulators that feature an extremely high level of energy density. This type of battery has to be handled with particular care when in use and when charging/discharging. Mishandling can lead to a premature wear out or defect, or permanent damage. Self-Discharge: LiPoly cells have an extremely low self-discharge rate (approx. 0.2% per day), which is why they can be stored over longer periods of time without any problems. If the voltage drops below 2.5 volt/cell, it is imperative that the cell is recharged. An exhaustive discharge is to be avoided, otherwise the cell can suffer permanent damage in the form of capacity loss. Durability: The theoretical durability or lifespan of a cell with low levels of discharge currents lies at around approx. 500 charging/discharging cycles. A used battery has to be disposed of correctly! Battery Disposal: Never throw used batteries in the regular garbage. In order to help protect the environment, defective and used batteries have to be handed in at the appropriate collection points and in a discharged condition. Collection points can be found at the sales outlets for batteries or at municipal collection points for hazardous waste. Please mask the bare contacts with adhesive tape in order to avoid short circuiting. SAFETY INSTRUCTIONS FOR LITHIUM ION POLYMER BATTERIES (LiPoly batteries) (cont.) DISCLAIMER Due to the fact that Metrix cannot monitor the handling of the batteries, any liability and warranty is expressly disclaimed with regard to incorrect charging / discharging or handling. Doc# 100911 REV B (May 2016) Page 7 of 8

6. ENVIRONMENTAL INFORMATION This electronic equipment was manufactured according to high quality standards to ensure safe and reliable operation when used as intended. Due to its nature, this equipment may contain small quantities of substances known to be hazardous to the environment or to human health if released into the environment. For this reason, Waste Electrical and Electronic Equipment (commonly known as WEEE) should never be disposed of in the public waste stream. The Crossed-Out Waste Bin label affixed to this product is a reminder to dispose of this product in accordance with local WEEE regulations. If you have questions about the disposal process, please contact Metrix Customer Services. info@metrixvibration.com www.metrixvibration.com 8824 Fallbrook Dr. Houston, TX 77064, USA Tel: 1.281.940.1802 Fax: 1.713.559.9421 After Hours (CST) Technical Assistance: 1.713.452.9703 Doc# 100911 REV B (May 2016) Page 8 of 8