I-799/79V Coil Components

Similar documents
I-731-D/W731-D. Suction Diffuser. Important Installation Information. series 731-D and W731-D

Installation Operation & Maintenance Instructions

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

I-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING

I-231.T2S1/CLAD. Victaulic Style 231 Non-Restrained, Flexible Expansion Coupling with Cladding on Expansion Side of Pipe WARNING IMPORTANT INFORMATION

PRO-BALANCE 1 1/4 IN. BRASS MANIFOLD. Product Instructions

I-VIC300MS. Vic -300 MasterSeal Butterfly Valves WARNING SERIES 761

I-BFV.KIT Butterfly Valve Gear Operator Replacement

I-VICFLEX.AB5. Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile (60 mm) Channel Ceiling Systems WARNING

I-795/906. Series 795 and 906 Installation-Ready Knife Gate Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS

HKV 1 1/4 in. Brass Manifold Product instructions. Construction Automotive Industry

I-VICFLEX.AB11. Victaulic VicFlex Style AB11 Low-Profile Sprinkler Fitting for Suspended Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

Hose Length Custom Length Supply Line Options Ball Valve w/ PT UBY Strainer w/ PT and BDV

Innovation + Quality. Valves, controls + systems Balancing and Control Valves

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

GBV-G Balancing Valves

I-VIC300MS. Series 761 Vic-300 MasterSeal Carbon Steel Butterfly Valve Series 461 Vic-300 MasterSeal Stainless Steel Butterfly Valve WARNING

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

B21 Series BASOTROL Gas Valve

METERING VALVE 2" STEM GUIDED

I-VICFLEX.AB1/AB2/AB10

I-NXT.RBKIT 5-Year Rebuild Kit Instructions for FireLock NXT Valves

Escape Cylinder and Valve

Installation, Operation and Maintenance Manual

Manifold Isolation Valves

Signet 2517 Brass Paddlewheel Flow Sensor * *

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

IMPORTANT NOTE! Please take the time to read this instruction sheet. Disregarding these guidelines may adversely affect your piping components

I-234. Victaulic Styles 234/234S Restrained, Flexible Single-Gasket Couplings WARNING IMPORTANT INFORMATION ITEMS PROVIDED WITH SHIPMENT:

Sentinel 250 Fire Hydrant

I-232.T3S2 Victaulic Style 232 Restrained, Flexible High-Pressure Coupling

ZONE CONTROLE / 2-WAY

Victaulic Discharge CBV Vibration Isolation Pump Drop Series 383/383G

Dual Remote Filtration System Installation and Servicing Instructions

Firehawk Second Stage Regulator Fire Service

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Vic-Strainer WARNING. System No. Submitted By Spec Sect Para Location Date Approved Date IPS CARBON STEEL PIPE - GROOVED ACCESSORIES SERIES 730

PIPING PACKAGES TABLE OF CONTENTS

Installation Instructions

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

TECHNICAL INSTRUCTIONS #11 REGULATOR Single Seat - Bronze Trim - Composition Disc

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

Water Meter & Flow Sensor

BMK-18 U.S. Patent #5,298,158

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

GRINNELL MODEL CB800 CIRCUIT BALANCING VALVE INSTALLATION & SETTING HANDBOOK

Easy Riser swing check valve Models E-1 & F-1

Paint/Solvent/Dump Valve and Flow-Through Valve

USER MANUAL. LP Unit 5000 PSI. HP Unit 7500 ALL - IN - ONE ALL - IN - ONE ALL - IN - ONE. 4" Drive Handles. LP Units Available in 12" Insertion Length

ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

I-VICFLEX.AB7 VicFlex Sprinkler Fittings for Ceiling Suspension Systems STYLE AB7

Bypass / Filter Feeders Operations & Maintenance Manual

PV4 - Compact Shut Off Style Pig Valve IOM - Installation, Operation & Maintenance

Full Flow Drinking Water System Model: 3MFF100

4410 TwinHydrostatic Gas Seal

DP Series Diaphragm Valve Installation and Maintenance Instructions

CV Control Valves Installation and Operation Manual

OWNER S MANUAL D.E. CARTRIDGE. Installation Operation Parts. Models PCDE-30 PCDE-40

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS

TECHNICAL INSTRUCTIONS Heavy Duty Bronze Series

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1-1/2-2 )

Powers Controls Powertop Two-Way Valves Normally Open

1 1/4 NPT FILTER 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS. Hole Size Designation 150 Mesh 1M150

PIPING PACKAGES For Chilled and Hot Water Fan Coil Units

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

FOR TECHNICAL ASSISTANCE

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

I & M Mark 78 Series. Ideal Installation. Start-Up. Installation & Maintenance Instructions for Mark 78 Control Valves (1/2-1 )

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

New Fan Coil Piping Packages

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

1/2" AIR DRIVEN DIAPHRAGM PUMP

Model Ton Hand Carry Axle Jack P/N: CJ67D0250-1

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 7: TUBING AND PIPING

Type N550 Snappy Joe Emergency Shutoff Valves

Powers Controls 656 Powermite Valve with 3-inch Top Rebuilding

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

INSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website

SECTION VALVES

599 Series Zone Valve Bodies:

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

MrPEX 1 ½ " Brass Manifold Installation Guide

ROOTS Meters Series B3 Meter Models 8C175-56M175

Temperature Sensor Series

INSTALLATION INSTRUCTIONS

Transcription:

WARNING Read and understand all instructions before attempting to install any Victaulic products. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic products. Wear safety glasses, hardhat, and foot protection during installation. Failure to follow these instructions could result in serious personal injury and property damage. RECEIVING THE SHIPMENT Victaulic are a pre-packaged and labeled system designed to improve efficiency of hooking up HVAC coils. Upon receipt of the shipment, ensure that the kit is the correct one for the coil being installed. If any components are damaged or missing, contact Victaulic at -800-PICK VIC. Union Port Fitting with Air Bleed The Series 78U Union Port Fitting with Air Bleed can accommodate up to a three-size reduction using adapters. The connections can be configured, as listed below: Female Thread x Male Thread Union Sweat x Male Thread Union PermaLynx x Male Thread Union Y Strainer/Ball Valve Combination or T Ball Valve The Series 78Y Strainer/Ball Valve Combination or Series 78T Ball Valve can accommodate up to a two-size reduction from inlet to outlet. The connections can be configured, as listed below: Female Thread x Female Thread Female Thread x Sweat Sweat x Sweat Sweat x Female Thread PermaLynx x PermaLynx Balancing Valve The Series 78K Balancing Valve contains a male threaded union inlet or female threaded union inlet and can expand up to three sizes to a female threaded outlet, PermaLynx outlet, or sweat outlet. As an option to the Series 78K Balancing Valve, a Series 787 Tour and Andersson Balancing Valve with female threaded ends or a Series 786 Tour and Andersson Balancing Valve with sweat ends can be incorporated into the coil hookup. Coil Hoses Coil Hoses are available in -foot/0.-meter, -foot/0.6-meter, or -foot/0.9-meter lengths for hooking up to the inlet and outlet of the coil. The hoses are available with the following union ends: male threaded x female threaded swivel or male threaded x male threaded swivel. NOTICE When the PermaLynx option is chosen (up to /-inch/.- mm in size), the Style 60 Male Thread x PermaLynx Adapter is factory-assembled to the Series 78K Balancing Valve. Always refer to the I-PermaLynx instructions for complete installation requirements. The maximum pressure rating for PermaLynx products is 00 psi/ Bar. EXAMPLE COIL COMPONENT ASSEMBLY DRAWING ATC TA Series 786/787 OR Series 78K RETURN Coil Hose Series 78U COIL Coil Hose Series 78Y OR Series 78T SUPPLY VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 00 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.

IMPORTANT INFORMATION - SWEAT CONNECTIONS Sweat connections must be soft soldered with 9/ (9% tin, % antimony) type solder. When soldering, the valve body must be heat sinked with a wet cloth or putty at the closest solder connection to protect internal components, and the flame must be directed away from the center of the valve body. DO NOT exceed the temperature rating of the valve (0 F/ C). Make sure all valves are installed in the correct direction of flow (refer to flow direction arrow on the valve body). Ball valves must be in the fully closed position before attempting to solder the ends. Balancing valves must be in the fully open (.0) position before attempting to solder the ends. All valves must be allowed to cool down to room temperature before attempting operation. When sweating/soldering near PermaLynx products, use a wet towel to cover the fitting plus inches/76 mm of the tube closest to the sweat/ solder point. The flame MUST be kept a minimum of 6 inches/ mm away from the product. Heat damage to the rubber seals in PermaLynx products will cause leaks. Refer to the I-PermaLynx installation instructions for complete information. IMPORTANT INFORMATION - THREADED CONNECTIONS Make sure all threaded connections are clean and free of any burrs. Apply a small amount of pipe joint compound or Teflon* tape to the external threads of all threaded pipe connections. DO NOT use a combination of tape and pipe joint compound. DO NOT get any tape, pipe joint compound, or other foreign material into the flow path. IMPORTANT INFORMATION - PERMALYNX CONNECTIONS Reference must be made to the I-PermaLynx installation instructions to ensure proper tube preparation and insertion depth requirements are achieved. The I-PermaLynx ships with PermaLynx products and can be downloaded from the website. IMPORTANT INFORMATION - UNION-TYPE ADAPTERS/CONNECTIONS The o-rings in union-type adapters/connections must be lubricated with Victaulic Lubricant or silicone to prevent the o-ring from pinching or tearing during installation. Tighten union-type adapters/connections hand-tight, then apply an additional quarter turn. DO NOT over-tighten the connection. COIL COMPONENT INSTALLATION. Connect the supply side of the Series 78Y Strainer/Ball Valve Combination or Series 78T Ball Valve to the feed pipe via standard threading, sweating, or PermaLynx practices. Refer to the prior sections for important information. Make sure the flow direction arrow on the valve body is facing the direction of flow and that the valve body is rotated to the desired position. NOTE: It is not recommended to have the pressure/temperature ports facing straight downward.. If using Coil Hoses, make the connection to the coil first. Connect the Coil Hose to the Series 78Y or Series 78T outlet union joint. Ensure the o-ring is in place on the Series 78Y or Series 78T body. Apply a thin coat of Victaulic Lubricate or silicone to the o-ring. Refer to the Coil Hose Installation section for details on bend radius specifications and other installation requirements. D D D 0 D D, D, or 0D =,, or 0 pipe diameters Pump. Connect the outlet of the balancing valve to the return pipe via standard threading, sweating, or PermaLynx practices. NOTE: In order to obtain accurate differential pressure measurements, turbulence must be minimized. Refer to the drawings above for examples of piping configurations.. Connect the Coil Hose (if applicable) to the inlet of the Series 78U Union Port Fitting with Air Bleed. NOTE: Between the male union outlet of the Series 78U and the inlet of the balancing valve, there is a customer-specified Automatic Temperature Control (ATC) valve. Ensure the ATC valve contains the correct inlet and outlet sizes. Cutout lengths, etc. will need to be determined on a caseby-case basis, depending on the type of ATC valve being installed. Refer to the instructions supplied with the ATC valve for complete installation and maintenance requirements. * Teflon is a registered trademark of the DuPont Company VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 00 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. _

COIL HOSE INSTALLATION CAUTION The following table contains the minimum distance requirement from each ferrule to the start of the bend. This table must be referenced to prevent the hose from being bent too close to the ferrules. DO NOT introduce chemicals into the system without verifying compatibility with the Coil Hose materials. Failure to follow this instruction could cause damage to the hose, resulting in property damage. Straight Pipe NPSM Female Swivel End Fiber Gasket Ferrule Stainless Steel Braided Hose Ferrule NPT Male End Nominal ID inches / / / / Minimum Distance from Each Ferrule to Start of Bend inches/mm / 8 / 6 76 0 Nominal ID inches Inlet Options inches Male End Thread / x / NPT / / x / NPT / x NPT Bend Radius Maximum Working Pressure NPSM MNPT Swivel Union inches/mm psi/bar /8 7 67 6 / 00 / 00 0 / x / NPT / 6/ 7 6 / x / NPT / 8/8 0 0 x NPT / 0 86 0 The minimum temperature rating for Coil Hoses is F/ C. The maximum temperature rating for Coil Hoses is 0 F/0 C. Coil Hoses are intended for water applications only. DO NOT attempt to use these hoses in gas applications. INCORRECT INCORRECT INCORRECT INCORRECT To prevent damage to the connections, torque during assembly must not exceed 0 ft-lbs/ N m. The wrench must engage only the hex portion of the hose ends. After the system is pressurized, check the Coil Hoses for leaks or discoloration on the stainless steel braided section or connections. If leaks are present, replace the affected Coil Hose(s). DO NOT attempt to repair hoses. MAINTENANCE WARNING Depressurize and drain the piping system before attempting to perform any maintenance on Victaulic products. Failure to follow this instruction could result in serious personal injury and/or property damage. Pressure/ Hex Washer-Head Screw Hex Socket Tight Union Nut O-Ring Handle FLOW CORRECT +% Minimum CORRECT CORRECT Drain Valve Adapter 0-Mesh Stainless Steel Strainer Basket O-Ring Coil Hoses can change in length approximately % when pressurized. Allowance must be given to accommodate for this change in length; therefore, Coil Hoses must not be stretched tightly between the coil and mating component. Refer to the drawing above for examples of correct and incorrect bend configurations. If the bend radius, listed in the table above, falls below the dimension listed for the applicable hose size, an angle adapter must be used to avoid sharp bends. NOTE: Exceeding the bend radius can cause reduction in flow and damage to the hose. If Coil Hoses are stored or installed at temperatures of 0 F/ C or lower, the bend radius should be increased by 0%. Use caution to prevent the hose from collapsing. Hose-End Drain Assembly The only maintenance required is for the Series 78Y. A 0-mesh stainless steel strainer basket is included in the valve body and must be inspected and cleaned after system startup and a minimum of every six months thereafter. To access the strainer, remove the drain valve adapter from the valve body. Clean out the strainer basket and replace it into the valve body in the same orientation. If any damage to the strainer basket or o-ring of the drain valve adapter is present, replace them with new, Victaulic-supplied components. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 00 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. _

BALANCING VALVE ASSEMBLY DRAWINGS Newer Design with Plastic Sleeve (Series 787 Shown Below) FLOW PRE-SETTING THE BALANCING VALVE 0 0 Short Pressure/ Long Pressure/ Plastic Sleeve Valve Body Bonnet Assembly Red Holder Cover Blue Holder Plastic Handwheel Previous Design with Sleeve and Nut (Series 787 Shown Below) FLOW. To pre-set the balancing valve to a certain pressure drop, turn the plastic handwheel of the bonnet assembly clockwise until the fully closed (0.0) position is reached, as shown above. For this example the pre-setting position of. will be used. Short Pressure/ Long Pressure/ Gasket Sleeve Red Holder Nut Cover Cover Blue Holder Gasket Valve Body Bonnet Assembly Plastic Handwheel. Turn the plastic handwheel of the bonnet assembly counterclockwise. turns, as shown above. INSTALLING THE BALANCING VALVE DRAIN KIT The drain kit (part number K-000-786-CBV) for Series 786, 787, and 78K Balancing Valves is sold separately through Victaulic and comes with two new gaskets, a drainage nipple, and a nut. Contact Victaulic at -800-PICK VIC with any order requests or questions regarding this kit. FLOW Inner Spindle for Pre-Setting Drainage Nipple Gasket* Gasket* Nut Cover *NOTE: New gaskets must be used.. Remove the components from the long pressure/temperature port, shown in the assembly drawings above. NOTE: The cover with red holder will be re-used when the drain kit is installed.. Install the drain kit components, as shown in the drawing above. The new gaskets (provided in the kit) must be installed to prevent leakage from the port. Re-install the cover with red holder onto the nut.. Locate the recess under the cover. Insert a -mm allen key, and apply 8 - turns to drain from the pressure/temperature port.. Using the -mm allen key (supplied with the balancing valve), turn the inner spindle clockwise until it stops. The balancing valve is now pre-set to the. position. NOTE: Refer to the graph on this page, which shows the pressure drop curves for various settings and flows for each valve size. BALANCING AND MEASURING The Series 77 CBI-II Computerized Balancing Instrument or the Series 7M CMI Pressure Differential Meter should be used to obtain direct readings for temperature, flow, and differential pressures through the balancing valve. Always refer to the operating manual, provided with the measuring instrument, for detailed information. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 00 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. _

PRESSURE DROP GRAPH FOR SERIES 786, 787, AND 78K BALANCING VALVES This graph shows the pressure drop across the pressure test ports of the balancing valve. A straight line connecting the bars for flow rate, C V, and pressure drop shows the relationship between these variables. The position for each valve size is arrived at by drawing a horizontal line from the C V value obtained. EXAMPLE: To pre-set a -inch/.7-mm valve at a desired flow rate of 6.7 GPM and a pressure drop of feet: Draw a straight line joining 6.7 GPM and feet. The C V =.9. Draw a horizontal line from C V.9. This intersects the bar for a -inch/.7-mm valve at the desired pre-setting of. turns. NOTE: If the flow rate falls outside of the scale in the diagram, the reading can be made as follows: Starting with the example above ( feet, C V.9, flow rate 6.7 GPM): At feet and a CV of.9, the flow rate =.67 GPM. That is, for a given pressure drop, it is possible to read 0 times or 0. times the flow and C V values.. 0 00 00 0. 0. 0. 0. 0.0. 0 0 70 0 0 0 0 0 7.. 0.7 0. 0. 70 0 0 0 0 0 7.. 0.7 0. 0. 0. 0.7 0. 0. Setting, number of turns 0.7 0. 0............. 0 0 0 0*) 0 0 **) 0. 0. * db (A) ** db (A) 0 00 0. l/s GPM Cv Kv ½" ¾" ½" ¾" " ¼" ½" " ft. kpa Series 78 Series 786/787 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 00 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. _

BONNET ASSEMBLY REPAIR KIT FOR SERIES 786, 787, AND 78K BALANCING VALVES WARNING Depressurize and drain the piping system before attempting to perform any maintenance or install any kits on Victaulic products. Failure to follow this instruction could result in serious personal injury and/or property damage. The bonnet assembly repair kit is sold separately through Victaulic. Contact Victaulic at -800-PICK VIC with any order requests or questions regarding this kit.. Turn the plastic handwheel of the replacement bonnet assembly counterclockwise until the fully open position (.0) is reached, as shown above. 0 The bonnet assembly repair kit consists of a new bonnet assembly and o-ring for the Series 786, 787, and 78K Balancing Valves in / - -inch/6.9-60.-mm sizes. Contact Victaulic for details.. Turn the plastic hand wheel of the bonnet assembly counterclockwise until the fully open position (.0) is reached, as shown above. 0. Apply a very thin layer of Victaulic Lubricant or silicone to the new o-ring. a. Install the new o-ring over the threads of the bonnet assembly, as shown above. DO NOT use tape or dope on the threads.. Tighten the new bonnet assembly into the balancing valve body until metal-to-metal contact is achieved. 6. To pre-set the balancing valve, refer to the Pre-Setting the Balancing Valve section.. Remove the bonnet assembly from the balancing valve body. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 00 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. _6

ADDITIONAL KIT INFORMATION WARNING Depressurize and drain the piping system before attempting to perform any maintenance or install any kits on Victaulic products. Failure to follow this instruction could result in serious personal injury and/or property damage. Port Extender for Series 78Y Strainer/Ball Valve Combination, Series 78T Ball Valve, or Series 78U Union Port Fitting with Air Bleed (Part Number P-000-78Y-XT to Clear inches/-mm of Insulation or P-000-78Y-XT to Clear inches/0-mm of Insulation) The following kits are sold separately through Victaulic for Coil Components. Contact Victaulic at -800-PICK VIC with any order requests or questions regarding these kits. Hose-End Drain Assembly for Series 78Y Strainer/Ball Valve Combination or Series 78T Ball Valve (Part Number P-00-78Y-DRN for /-inch NPT or P-00-78Y-DRN for /-inch NPT) In applications where the will be insulated, the port extender is available to extend the pressure/temperature ports of the Series 78Y or the air vent of the Series 78U to clear inches/ -mm or inches/0-mm of insulation. Thread the port extender into the existing pressure/temperature ports or the existing air vent. DO NOT use tape or dope on the threads. Handle Extension for Series 78Y Strainer/Ball Valve Combination or Series 78T Ball Valve (Refer to Table Below for Part Numbers) The hose-end drain assembly is field replaceable for the Series 78Y or Series 78T. Remove the existing hose-end drain assembly from the drain valve adapter, and thread the new assembly into the adapter. DO NOT use tape or dope on the threads. Replacement Pressure/s for Series 78Y Strainer/ Ball Valve Combination, Series 78T Ball Valve, Series 78U Union Port Fitting with Air Bleed, or Series 786/787/78K Balancing Valves (Part Number P-00-78Y-PTP for 78Y/78T/78U or K-000-70-00 for 786/787/78K) Handle Extension Nominal Diameter inches/mm / - / - 0 - / - / - 0-0 Part Code for -inch Handle Extension P-00-78Y-HL P-00-78Y-HL P-00-78Y-HL Part Code for -inch Handle Extension P-00-78Y-HL P-00-78Y-HL P-00-78Y-HL The pressure/temperature ports are field replaceable. Remove the existing pressure/temperature port(s), and thread the new port(s) into the valve body. DO NOT use tape or dope on the threads. Replacement Air Vent for Series 78Y Strainer/Ball Valve Combination and Series 78U Union Port Fitting with Air Bleed (Part Number P-00-78U-MAV) In applications where the will be insulated, the handle extension is available to extend the handle of the Series 78Y to clear inches/-mm of insulation. Remove the hex washer-head screw from the handle assembly. Remove the handle assembly and install the handle extension. Re-install the handle assembly onto the handle extension by using the hex washer-head screw. The air vents are field replaceable. Remove the existing air vent, and thread the new air vent into the valve body. DO NOT use tape or dope on the threads. VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 00 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA. _7

For complete contact information, visit 9 REV C UPDATED 06/00 Z0079900 VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY. 00 VICTAULIC COMPANY. ALL RIGHTS RESERVED. PRINTED IN THE USA.