IECEx Certificate of Conformity

Endress+Hauser Wetzer GmbH+Co. KG Obere Wank Nesselwang Germany. Field Temperature Transmitter itemp, Types TMT82, TMT84 and TMT85

IECEx Certificate of Conformity

IECEx Certificate of Conformity

The filling level sensors are designed in accordance to the following standards

Attachment to Certificate IECEx PTB X

TB range of empty sheet metal enclosures. R S Sindair K~'

Safety instructions VEGAVIB VB6*.GI**C/R/T/Z/N*** IECEx BVS Ex ta, ta/tb, tb IIIC T Da, Da/Db, Db IP66

TECHNICAL BULLETIN. Sandvik MB670 Bolter Miners

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

MFH MOFH JMFH JMFDH NVF3 MUFH VOFD VOFC VSNC VUVS

IECEx Certificate of Conformity

CERTIFICATE OF COMPLIANCE

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Magnetic Switches for WEKA Visual Level Indicators Australian Version

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Annex 1 to Certificate of Conformity IECEx KEM X, issue 4 Annex 1 to IECEx Test report NL/KEM/ExTR /04 Annex 1 to KEMA 02ATEX1090 X, issu

Operating Instructions for Paddle Flow Monitor. Model: PSR-..., PSE-...

Certificate of Conformity

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Operating Instructions in accordance with IECEx Scheme rules, IECEx 02 polykom

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Operating Instructions

Certificate of Compliance

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Capacitive level sensors CLS 23

ExBin-P Pressure switches 5 Pa Pa

Solenoid Valves Type 3963

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Type 4746 Electric or Pneumatic Limit Switch

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Leading the way in hazardous areas Features EATON

Compact temperature switch Model TCS

EXAMINATION CERTIFICATE

Mini temperature switch Stainless steel switch enclosure Model TXS

Solenoid Operator 0516 / 1216

PHOENIX CONTACT - 01/2008

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

Capacitive Sensors. Series 80 - PNP

Solenoid Valve Island Type 3965

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Safety Instructions Proline Promass 300

T 3965 EN Type 3965 Solenoid Valve Island To control pneumatic actuators

Certificate of Conformity

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Surface thermocouple Model TC50

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Certificate of Compliance

Mini pressure switch Stainless steel switch enclosure Model PXS

Compact differential pressure switch Models DC, DCC

Ex m Solenoid Operator Type 0519

Certificate of Conformity

Limit Switch Type 4747

Operating Instructions for Viscosity Compensated Flow Meter / Monitor. Model: VKM

ATEX LABELLING FOR MOTORS AND GEAR UNITS

Compact pressure switch Model PCS

Explosion protection. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion


Temperature sensor TE2

Load cells. Data sheet. Special features. Cable assignment (six wire configuration)

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

SERIES 54 Inductive Proximity Sensor

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

Solenoid coils VACF Type codes

Magnetic-inductive flow meter for hazardous areas

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Certificate of Compliance

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

INSTRUCTION MANUAL (ATEX / IECEx)

Cable resistance thermometer Model TR40

Floodlight Series 6121

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Product specification

OPERATING INSTRUCTIONS

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Series 3730 Electropneumatic Positioner Type

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

IQL Helios Area-/Streetlight. User Manual

RedCos-P Pressure sensor 20 Pa Pa

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Assembly. Trunk IN + - S U, I U, I. Spur 1

Product specification

INSTRUCTION MANUAL (ATEX / IECEx)

ADVANTAGES. Air + combustible gas + ignition source = explosion. Air + combustible dust + ignition source = explosion

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

I Ex-control stations I

Product specification

Wolflite XT Rechargeable LED Handlamp

RedBin-P Pressure switches 5 Pa Pa

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Transcription:

IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Status: IECEx BVS 06.0003 Current Issue No: 7 Certificate history: Issue No. 7 (2017-11-24) Issue No. 6 (2016-10-13) Date of Issue: 2017-11-24 Page 1 of 4 Issue No. 5 (2016-01-29) Issue No. 4 (2013-11-05) Applicant: ifm electronic gmbh Friedrichstrasse 1 45128 Essen Germany Issue No. 3 (2010-11-08) Issue No. 2 (2009-03-04) Issue No. 1 (2007-10-16) Issue No. 0 (2006-04-06) Equipment: Optional accessory: Inductive proximity switches types NE5001, NE5012, NF5001, NF5002, NF5003, NF5004, NF5008, NF5010, NF5012, NF5023, NF5030, NT5001, NT5005, NG5001, NG5002, NG5011, NG5019, NG5003, NG5004, NG5010, NG5016, NG5021, NI5001, NI5002, NI5012, NI5003, NI5004, NI5011, NN5001, NN5002, NN5020, NS5002, NS5003, NS501A, NS503A, N95001, NN5008, NN5009, NN5011, NN5013, NN5017, NN5018, NM500A, NM501A, NF500A, NF501A, NG500A, NG501A, NI500A, NI501A, Capacitive proximity switches KI5030, KI5031 Type of Protection: Equipment protection by intrinsic safety "i" Marking: See Approved for issue on behalf of the IECEx Certification Body: Jörg Koch Position: Head of Certification Body Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: DEKRA EXAM GmbH Dinnendahlstrasse 9 44809 Bochum Germany

IECEx Certificate of Conformity Certificate No: IECEx BVS 06.0003 Issue No: 7 Date of Issue: 2017-11-24 Page 2 of 4 Manufacturer: ifm efector gmbh Ifm Strasse 1 88069 Tettnang Germany Additional Manufacturing location(s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition:6.0 IEC 60079-11 : 2011 Edition:6.0 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: DE/BVS/ExTR06.0032/05 DE/BVS/ExTR06.0033/03 DE/BVS/ExTR06.0034/05 Quality Assessment Report: DE/BVS/QAR06.0010/06

IECEx Certificate of Conformity Certificate No: IECEx BVS 06.0003 Issue No: 7 Date of Issue: 2017-11-24 Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: Subject and Type See Description See Parameters See SPECIFIC CONDITIONS OF USE: NO

IECEx Certificate of Conformity Certificate No: IECEx BVS 06.0003 Issue No: 7 Date of Issue: 2017-11-24 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): See : BVS_06_0003_ifm_issue_7.pdf

Page 1 of 11 DE/BVS/ExTR06.0032/05 Marking Order code Gas Dust NE5001, NE5012 Ex ia IIC T6/T5 Ga Ex ia IIIC T90 C/T100 C Da NF5001, NF5002, NF5003, NF5004, NF5008, NF5010, Ex ia IIC T6/T5 Ga Ex ia IIIC T90 C/T100 C Da NF5012, NF5023, NF5030 NG5001, NG5002, NG5003, NG5004, NG5010, NG5011, NG5016, NG5019, NG5021 Ex ia IIC T6/T5 Gb Ex ia IIB T6/T5 Ga Ex ia IIIC T90 C/T100 C Da NI5001, NI5002, NI5003, Ex ia IIC T6/T5 Gb NI5004, NI5011, NI5012 Ex ia IIB T6/T5 Ga Ex ia IIIC T90 C/T100 C Da NT5001, NT5005 Ex ia IIC T6/T5 Ga Ex ia IIIC T90 C/T100 C Da NN5001, NN5002, NN5020 Ex ia IIC T6/T5 Gb Ex ia IIB T6/T5 Ga Ex ia IIIC T90 C/T100 C Da NS5002, NS5003, NS501A Ex ia IIC T6/T5 Gb Ex ia IIB T6/T5 Ga Ex ia IIIC T90 C/T100 C Da NS503A Ex ia IIC T6 Ga Ex ia IIIC T90 C Da General product information: Subject and Type Inductive proximity switches type N*50** In the complete marking, the asterisks are replaced by letters and numbers to indicate the different versions of the switches: Order code Housing Thread Sensor cap Cable length (m) Picture NE5001 M8 round Metal Plastic 2 NE5012 M8 round Metal Plastic 20 NF5001 Plastic Plastic 2 NF5002 Metal Plastic 2 NF5003 Plastic Plastic 2

Page 2 of 11 NF5004 Metal Plastic 2 NF5008 Metal Plastic 6 NF5010 Plastic Plastic 6 NF5012 NF5023 Metal Plastic 6 Metal Plastic 20 NF5030 Metal V2A Plastic 6 NG5001 Plastic Plastic 2 NG5002 Metal Plastic 2 NG5003 Plastic Plastic 2 NG5004 Metal Plastic 2 NG5010 Metal Plastic 10 NG5011 Metal Plastic 10 NG5016 Plastic Plastic 15

NG5019 Page 3 of 11 Plastic Plastic 6 NG5021 Metal Plastic 6 NI5001 Plastic Plastic 2 NI5002 Metal Plastic 2 NI5003 Plastic Plastic 2 NI5004 Metal Plastic 2 NI5011 Plastic Plastic 10 NI5012 Metal Plastic 10 NT5001 6.5 mm diameter, round Metal (no thread) Plastic 2 NT5005 6.5 mm diameter, round Metal (no thread) Plastic 6

Page 4 of 11 Order code Housing Main housing Cable length (m) Switching LED Picture NN5001 Plastic 2 None NN5002 Plastic 2 None NN5020 Plastic 10 None NS5002 16 x 27,8 mm Plastic 2 None NS5003 16 x 27,8 mm Plastic 2 Red NS501A 16 x 27,8 mm Plastic 12 Red NS503A 16 x 27.8 mm Plastic 0.13 None Description The inductive proximity switches are used for the detection of metallic or non-metallic objects. The switches are supplied via a permanently connected cable. The different versions of the switch differ in their internal electronics, their housing and connection cable. The sensors are permissible for use in areas with Ga or Gb resp. Da requirements. Parameters Connection wires L+ (brown) and L- (blue) Maximum input voltage U i DC 15 V Maximum input current I i 50 ma Maximum input power P i 120 mw Effective internal capacitance C i and Effective internal inductance L i in accordance with the following table: order code C i [nf] L i [µh] NE5001 80 70 NE5012 83 87 NF5001 140 340 NF5002 140 340 NF5003 140 130

Page 5 of 11 NF5004 140 130 NF5008 141 134 NF5010 141 134 NF5012 141 344 NF5023 143 147 NF5030 141 134 NG5001 145 45 NG5002 145 45 NG5003 155 50 NG5004 155 50 NG5010 157 58 NG5011 147 53 NG5016 157 62 NG5019 146 49 NG5021 156 54 NI5001 145 140 NI5002 145 140 NI5003 145 110 NI5004 145 110 NI5011 147 118 NI5012 147 148 NT5001 80 70 NT5005 81 74 NN5001 110 135 NN5002 110 135 NN5020 112 143 NS5002 80 110 NS5003 80 110 NS501A 85 120 NS503A 80 110 Ambient temperature range T a -20 C up to +70 C -20 C up to +80 C For ambient temperatures up to 70 C, the sensors are classified as T6 resp. T90 C. For ambient temperatures up to 80 C, the sensors are classified as T5 resp. T100 C (except NS503A). Additional remarks For sensors with metallic s, the s have to be included into local potential equalisation. This condition is included in the manual. For areas with Ga-requirements, the enclosure and cables have to be protected from electrostatic charging. The manual includes a respective installation instruction that cables and non-metallic enclosures have to be protected from electrostatic charging.

Page 6 of 11 Details of change Subject of this supplement are the modifications of the sensor types NF5001, NF5002, NF5003, NF5004, NF5008, NF5010, NF5012, NF5023, NF5030, NG5001, NG5002, NG5011, NG5019, NG5003, NG5004, NG5010, NG5016, NG5021, NI5001, NI5002, NI5012, NI5003, NI5004, NI5011, NN5001, NN5002 and NN5020. Changes: Several components New circuit diagram and layout Potting material Copper thickness

Page 7 of 11 DE/BVS/ExTR06.0033/03 Marking Order code Gas Dust KI5030 Ex ia IIB T6 Ga Ex ia IIIC T90 C Da KI5031 Ex ia IIB T6 Ga Ex ia IIIC T90 C Da Capacitive proximity switches type KI5030 and KI5031 Order code Housing Main housing Cable length (m) Switching LED Picture KI5030 Plastic 2 m yellow KI5031 Plastic 6 m yellow Description The capacitive proximity switches type KI5030 and KI5031 have a plastic housing with permanently connected cable. Type KI5031 differs from type KI5030 in the length of the permanently connected cable only. Type KI5030 has a cable length of 2 m, KI5031 has a cable length of 6 m. The sensors are permissible for use in areas with Ga- resp. Da-requirements. Parameters Maximum input voltage U i DC 15 V Maximum input current I i 50 ma Maximum input power P i 120 mw Effective internal capacitance C i for type KI5030 375 nf for type KI5031 375.64 nf Effective internal inductance for type KI5030 1 µh for type KI5031 3 µh Ambient temperature range T a -20 C up to +60 C L i Additional remarks The proximity switches shall be installed in such a way, that intensive electrical charging of the cables is excluded. A respective text is part of the manual. Details of change: There are no changes for the capacitive proximity switch type KI5030 and KI5031.Type KI5031 differs from type KI5030 in the length of the permanently connected cable only.

Page 8 of 11 DE/BVS/ExTR06.0034/05 Marking N95001 Order code Gas Dust Ambient temperature range NF500A, NF501A, NG500A, NG501A NI500A, NI501A, NN5008, NN5009, NN5011, NN5013, NN5017, NN5018 Ex ia IIC T6 Gb Ex ia IIIB T90 C Da -20 C up to +70 C Ex ia IIC T6 Ga Ex ia IIIC T90 C Da -20 C up to +70 C Ex ia IIC T6 Gb Ex ia IIB T6 Ga Ex ia IIIC T90 C Da -20 C up to +70 C NM500A, NM501A Ex ia IIB T6 Gb Ex ia IIIC T90 C Da -20 C up to +70 C General product information: Subject and Type Order code Housing Main housing Cable length (m) Switching LED Picture N95001 55 x 78 mm Plastic RD24x1/8 connector 2 x yellow NN5008 Plastic M12 connector 2 x yellow NN5009 Plastic 2 m 2 x yellow NN5011 Plastic 10 m 2 x yellow NN5013 Plastic M18 connector 2 x yellow NN5017 NN5018 Plastic M18 connector 2 x yellow Customer speciifc Plastic 5 m 2 x yellow Customer speciifc NM500A 40 x 40 mm Plastic M12 connector Yellow

Page 9 of 11 NM501A 40 x 40 mm Plastic M12 connector Yellow Order code Housing Thread Sensor cap Connection Switching LED Picture NF500A M12 round Metal Plastic M12 yellow NF501A M12 round Metal Plastic M12 yellow NG500A M18 round Metal Plastic M12 yellow NG501A M18 round Metal Plastic M12 yellow NI500A M30 round Metal Plastic M12 yellow NI501A M130 round Metal Plastic M12 yellow Description The inductive proximity switches are used for the detection of metallic or non-metallic objects. Types N*50*A, NN5008, NN5013 and NN5017 are supplied via a plug connector. The inductive proximity switches type NF500A, NF501A, NG500A, NG501A, NI500A and NI501A consist of coated brass with plastic active area. All types are supplied via a M12-plug. Types NN5008, NN5009, NN5011, NN5013, NN5017 and NN5018 consist of a plastic housing with 2 separate inductive sensor circuits. The sensors differ in their connection facilities only: NN5008 is supplied via a M12-plug, NN5013 and NN5017 via a M18-plug. The types NN5009, NN5011and NN5018 have a permanently connected cable with 2 m cable length (NN5009) resp. 5 m cable length (NN5018) resp. 10 m cable length (NN5011).

Page 10 of 11 Electrical parameters (not changed) 1 Types N*50*A and NN5008, NN5009, NN5011, NN5013, NN5017, NN5018 Voltage U i DC 15 V Current I i 50 ma Power P i 120 mw Effective internal capacitance C i and Effective internal inductance L i In accordance with the following table: order code C i [nf] L i [µh] NF500A 210 145 NF501A 210 115 NG500A 200 85 NG501A 200 190 NI500A 250 120 NI501A 230 210 NN5008 140 130 NN5009 140 130 NN5011 140 140 NN5013 140 130 NN5017 140 130 NN5018 140 135 NM500A 250 450 NM501A 220 710 Ambient temperature range T a -20 C up to +70 C For ambient temperatures up to 70 C, the sensors are classified as T6 resp. T90 C. 2 Type N95001 2.1 Connector field connection Rd 24x1/8 2.1.1 Circuit sensor 1 (pin 1 (+) and pin 4 (-)) circuit sensor 2 (pin 3 (+) and pin 2 (-)) values for each circuit Voltage U i DC 15 V Current I i 50 ma Power P i 120 mw Effective internal capacitance C i 150 nf Effective internal inductance L i 150 µh 2.1.2 Circuit valve (pin 5 (+) and pin 6 (-)) direct connected to connector valve 1112 (pin 1 (+) and pin 2 (-)) Voltage U i DC 28 V Power P i 2 W 2.2 Connector valve 1112 output values according to connection at connector valve Rd 24x1/8 (pin 5 (+) and pin 6 (-)) Ambient temperature range T a -20 C up to +70 C Additional remarks For use in areas with Ga-requirements, intensive charging has to be excluded. For types NN5009, NN5011 and NN5017 the permanently connected cables shall be installed fixed and protected. These conditions are included in the manual.

Page 11 of 11 Details of change Subject of this supplement are the modifications of the sensor types N95001, NN5017, NN5018, NM500A. Changes: Several components New circuit diagram and layout Potting material Copper thickness