Limousin II User Manual

Similar documents
Uninterruptible Power Supply

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

BRAVER UPS. (Uninterruptible Power System) User s Manual

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Eclipse Plus VA UPS and Surge Suppressor User s Manual

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

USER MANUAL. Uninterruptible power supply MODEL: 53965,

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Uninterruptible Power System

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

MM-AVR UPS Series User s Manual

Uninterruptible Power System

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

Liebert PSA VA. Installer/User Guide

CP900EPFCLCD User s Manual K

Uninterruptible Power System

Installation and Operation Back-UPS BX550CI-CN

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

661-SK [1]I:\USV_TEAM\USV_MANUAL\Roline\LineSecureII\661-SK [1].d oc U P S. Uninterruptible Power System

02/15/01. Powerware User s Guide VA.

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Back-UPS CS Back-UPS CS 350

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

UTILITY INPUT MAINS OUTLET

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

POWERWARE User s Guide VA.

BULL POWER Line Conditioner Regulating Power Bar

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

1. INTRODUCTION. Features:

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Installation and Operation Manual Back-UPS BR800/1100CI-IN

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

PR1000ELCD / PR1500ELCD User s Manual

Powerware Vdc Extended Battery Cabinet User s Guide.

Installation and Operation Manual Back-UPS BX1100CI-CN

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

GES-202TLP Traffic Light System Installation Manual

Uninterruptible Power Supply ERA LCD 0.65 ERA LCD 0.85 ERA LCD 1.1. User s manual

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Informer Compact Series

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

User Manual Rittal PMC UPS 6kVA

Uninterruptible Power Systems. SDU DC Series

Uninterruptible Power System

Sola/Hevi-Duty S3K Series Mini-Tower UPS

Aurora Single Phase Emergency Lighting Inverters

General Precautions. Personnel Precautions

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

3000VA 120/208/230VAC

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

User s Manual Legend SB825 UPS K

Installation and Operation Manual Back-UPS BR1000-CH

User s Manual Lineage LI3000 UPS K

SmartPro Medical-Grade UPS, Line Interactive, Lithium Battery, 6 Outlets - 230V, 1kVA, 750W, Full Isolation

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

Liebert PowerSure PSI

USER MANUAL. Line Interactive UPS. Uninterruptible Power System

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

USER MANUAL MPS 1-5KW SERIES

CERTIFIED CATEGORY III-3 PROTECTION

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

Line Interactive UPS 1000/1400/2000VA Uninterruptible Power System

SCC-MPPT Solar Charge Controller

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Installation and Operations Manual

ALLIANCE SERIES OWNER'S MANUAL

SCC-MPPT Solar Charge Controller

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

USER MANUAL ONLINE UPS

OWNER S MANUAL. Please read installation and operation instruction before using this Power inverter.

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

OPERATING INSTRUCTION UPS PROTECT A. PROTECT A PROTECT A. 1400

Solar Charge Controller

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

Sola 3000 Guide Specifications

PowerSure POWER PROTECTION USER S MANUAL. Uninterruptible Power System 250 VA 600 VA 115 V PS250-60S 250 VA PS400-60S 400 VA PS600-60S 600 VA.

Foreword

Transcription:

Limousin II User Manual 600VA Uninterruptible Power Supply Single Phase Input, Single Phase Output M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc

SAVE THESE SAFETY INSTRUCTIONS 1. This manual contains important instructions for the Limousin and should be followed during installation and maintenance of the UPS and batteries. 2. The UPS contains voltages that are potentially hazardous. Please contact our dealers or qualified personnel for service. 3. Only personnel whom are knowledgeable with batteries and the required precautions should perform any servicing on the batteries. Keep unauthorized personnel away from batteries. 4. Replace the batteries with the same model number, type and rating. 5. CAUTION: Do not dispose of batteries in a fire. The batteries may explode. 6. CAUTION: Do not open or mutilate the batteries. Contents of the batteries are toxic and especially harmful to the skin and eyes. 7. CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on or with the batteries. Remove watches, rings, or other metal objects. Use tools with insulated handles. Wear rubber gloves and boots. Do not lay tools or metal parts on top of batteries. Disconnect charging sources prior to connecting or disconnecting battery terminals. Make sure batteries are not inadvertently grounded. If inadvertently grounded, remove source of ground. Contact with any part of a grounded battery can result in electric shock. The likelihood of a shock will be reduced if ground faults are removed during installation and maintenance (applicable to a UPS and a remote battery supply not having a grounded supply circuit). 8. CAUTION: To ensure the safety and performance of the UPS, never load the UPS with a hair dryer, heater, laser printer or other types of inductive loads. 9. The UPS has its own internal energy source (battery), therefore the output receptacles may have electricity present even though the UPS is disconnected from the utility power. 10. The DC voltage provided from the internal battery is 12VDC. 11. Isolated Ground Wire refers to the wire connecting electrical equipment to ground. The isolated ground wire (green or green with yellow stripe) must meet national wire requirements. 12. The utility plug (wall plug) for the UPS must be equipped with a ground prong. 13. To avoid explosions, keep open flame and other heat emitting sources away from batteries. 14. The battery has the potential to generate high voltages and currents that are dangerous. To maintain secure operation and performance of the UPS, the user must exercise regular basic maintenance. Please follow the precautions below: 1. Do not remove the UPS cover unless authorized by the factory. Removing the cover will void the warranty. 2. The UPS can only be connected to a 2-pole/3 wire plug. 3. Do not install the UPS in an environment with excessive humidity. 4. Do not allow liquids or foreign objects to penetrate inside the UPS. 5. Allow for air circulation through the UPS. A minimum clearance of 10cm is required on all sides. 6. Do not overload the UPS with appliances such as a hair dryer, heater, vacuum, kettle, etc. 7. Keep the UPS away from direct sunlight and heat-emitting sources. 8. Install the UPS as close as possible to the load for maximum protection. 10. Storage Requirements 1. Recharge the UPS batteries every 6 months for no less than 8 hours at a time. 2. In a high ambient temperature environment, recharge the UPS batteries every 3 months for no less than 8 hours at a time M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc i

Table of Contents 1. INTRODUCTION...1 2. PRESENTATION...2 2.1. Front Panel...2 2.2. Rear Panel...2 3. INSTALLATION...3 3.1. Unpacking and Inspection...3 3.2. Placement...3 3.3. Connect to Utility...3 3.4. Charging the Battery...3 3.5. Connecting the Load...3 3.6. Storage Conditions...3 3.7. Extended Storage...3 4. OPERATION...4 4.1. Switching On the UPS...4 4.2. Switching Off the UPS...4 4.3. Self-Test...4 4.4. Silence the Alarm...4 4.5. Cold Start...4 4.6. Green Function...4 5. AUDIBLE ALARM...5 5.1. Back-Up (Slow Alarm)...5 5.2. Low Battery (Rapid Alarm)...5 5.3. Overload (Continuous Alarm)...5 5.4. Replace Battery (Continuous Alarm)...5 6. SOFTWARE OPTIONS...5 6.1. UPSMON Software...5 6.2. Interface Kits...5 6.3. Computer Interface Port...6 7. BATTERY REPLACEMENT...7 8. TROUBLESHOOTING...8 8.1. General Problems...8 9. SPECIFICATIONS...9 10. CONTACT INFORMATION...11 10.1. Additional Purchases or Upgrades...11 10.2. QA / Warranty Questions...11 10.3. Software Questions...11 M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc ii

1. INTRODUCTION The Limousin is an economical UPS solution that provides ultimate protection for your home and office equipment from destructive problems that plague the utility. With the Limousin, you can expect brownout and surge protection with the AVR function using on-line voltage boost-up & buck-down. This allows for a wide input voltage range of 90 to 150VAC. After the UPS has been turned On it will protect the load from transients, spikes and other power aberrations. In the event of a blackout (or severe brownout) the UPS will automatically switch to back-up mode. It will maintain power to the load until the battery reaches an exhausted state. Also included, with our UPS systems, is a cyclic self-testing function to verify both the operation of the UPS and the condition of the battery. The Limousin provides two single-phase 120VAC outlets for ease of connection to you equipment. Overload protection is also a feature of this unit. The Limousin utilizes state-of-the-art microprocessor technologies to incorporate all these features into such a compact and convenient package. Interference to Radio/TV The Limousin may cause interference to radios and TVs in close proximity. If you notice interference to radio or television reception, try turning the UPS off and on to see if the interference goes away. If so, the user is encouraged to try to correct the interference by one or more of following measures: 1. Move the Limousin and connected equipment to a different outlet. Check to make sure the new outlet is on a different power circuit than that of the radio/tv receiver. 2. Increase the separation distance between the Limousin and connected equipment, and the radio/tv receiver. 3. Re-orientate the receiving antenna. M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 1

2. PRESENTATION 2.1. Front Panel 1. Multi Purpose LED This LED will be solid green when the UPS is under normal conditions. It will flash every 2 seconds when the UPS is supplying battery power to the loads, and will flash rapidly when the battery needs replacement. 2. "ON/OFF/TEST/SILENCE" button Press and hold the button for more than 3 seconds to turn the UPS ON or OFF, press and hold the button less than 1 second to activate a self-test, or silence the back up alarm. 1 2 3 4 5 6 Figure 2.1 Limousin Front & Rear Panel 2.2. Rear Panel 3. Computer Interface RS-232 Interface is supplied to support Windows Novell, UNIX, DOS, and other operating systems. 4. Telephone/Modem/Ethernet Surge Protection Surge protection for telephone line, modem line, and 10BaseT line to maintain a completely safe connection for Internet/Intranet service. 5. AC Input Power Receptacle 6. Output Power Receptacles M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 2

3. INSTALLATION 3.1. Unpacking and Inspection Examine the Limousin UPS packaging for damage. Inform the carrier immediately if and/or when damage is noticed. Retain the packaging for future use. 3.2. Placement Install the Limousin UPS in a protected area with adequate airflow, free of excessive dust and other airborne particles. Allow for air circulation through the Limousin UPS. A minimum clearance of 10cm is required on all sides. Do not operate the Limousin UPS where the temperature and humidity is outside the specified limits. 3.3. Connect to Utility Connect the included AC input power connector to utility power and the UPS system. 3.4. Charging the Battery The UPS charges its battery whenever the UPS is in LINE mode. NOTE: For best results, initially charge the battery for 4 hours before connecting a load. 3.5. Connecting the Load Plug the load into the power outlets on the rear of the Limousin UPS. To use the UPS as a master on/off switch, make sure all of the loads connected to the UPS are switched on. CAUTION: Never connect a laser printer or plotter to the UPS with other computer equipment. A laser printer or plotter draws significantly more power when starting up than when idling. The laser printer or plotter will overload the UPS on start up. Thus, the UPS needs to be increased in size to accommodate the inrush of power if a laser printer or plotter requires protection against blackouts, brownouts and over-voltage. 3.6. Storage Conditions Store the UPS upright, covered and in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least eight (8) hours. 3.7. Extended Storage To store the Limousin UPS for extended periods, these instructions should be followed: 1. In environments where the ambient temperature is -15 to +30 C (+5 to +86 F), charge the UPS battery every 6 months. 2. In environments where the ambient temperature is +30 to +45 C (+86 to +113 F), charge the UPS battery every 3 months. M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 3

4. OPERATION 4.1. Switching On the UPS Make sure the Limousin UPS is plugged in and the utility power is present. Press and hold the On/Off/Test/Silence Button for more than 3 seconds or until the LED is lit. This switches the Limousin UPS On. The UPS will perform self-testing each time it is switched On. 4.2. Switching Off the UPS Press and hold the On/Off/Test/Silence Button for more than 3 seconds, or until the Line Normal or Back-Up LED turns off. 4.3. Self-Test Use the self-test to verify both the operation of the UPS and the condition of the battery. When normal utility power is present, push the On/Off/Test/Silence Button for less than 1 second and the UPS will perform a self-test function. During the self-test, the UPS operates in back-up mode. During the self-test, the UPS briefly provides power to the load from the batteries. The LED shall flash every 2 seconds during this test. If the UPS passes the self-test, it returns to on-line operation. NOTE: On completion of the test, the LED stops flashing and remains on. If the UPS fails the self-test, it immediately returns to on-line operation. If a failure occurred, recharge the battery overnight and perform the self-test again. If the UPS still fails the self-test, ask our nearest dealer to replace the battery. The loads are unaffected when performing a self-test. 4.4. Silence the Alarm In Back Up mode, push the On/Off/Test/Silence Button for less than 1 second to silence the audible alarm. Note that, this function is void when under condition of "LOW BATTERY" or "OVERLOAD" 4.5. Cold Start When the UPS is off and there is no utility power, use the cold start feature to apply power to the loads from the UPS battery. Press the On/Off/Test/Silence button until the UPS beeps. Please refer to Front Panel section for location of the indicator. 4.6. Green Function In order to conserve battery power, the UPS will automatically shutdown when in back-up mode, after 5 minutes, if the connected loads are operating at less than 20 watts. To disable GREEN FUNCTION press and hold the On button during initial start-up for at least 3 seconds, until a beep-beep sound is heard. M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 4

5. AUDIBLE ALARM 5.1. Back-Up (Slow Alarm) When in back-up mode, the LED flashes every 2 seconds and the UPS sounds an audible alarm. The alarm stops when the UPS returns to line normal operation. Press the On/Off/Test/Silence Button during back-up mode to silence the beeping. 5.2. Low Battery (Rapid Alarm) In back-up mode, when the battery energy runs low, the UPS beeps rapidly, twice every second, until the UPS shuts down from battery exhaustion or returns to line normal operation. This alarm cannot be muted. 5.3. Overload (Continuous Alarm) The UPS is overloaded when the connected load exceeds the maximum rated capacity of the UPS. The UPS sounds a continuous alarm to warn of an overload condition. Disconnect non-essential loads until the UPS stops the alarm, this will eliminate the overload. 5.4. Replace Battery (Continuous Alarm) The UPS emits a continuous beep if the battery fails the self-test. See replace battery section for battery replacement or call your dealer for services. 6. SOFTWARE OPTIONS 6.1. UPSMON Software The UPSMON software uses the standard RS-232 interface to perform monitoring functions, and then provides an orderly shutdown of a computer in the event of power failure. Moreover, UPSMON displays all the diagnostic symptoms through a graphical display, such as Voltage, Frequency, Battery Level, etc. The software is available for DOS, Windows 3.1x, Windows 95/98/00/XP & Windows NT V3.5 or later. 6.2. Interface Kits A series of interface kits are available for various operating systems that provide UPS monitoring. Each interface kit includes the special interface cable required to convert status signals from the UPS into signals that the individual operating system will recognize. The interface cable at the UPS side must be connected to the REMOTE PORT, at the computer side it can be connected to either COM1 or COM2. For other installation instructions and powerful features please refer to READ ME file included within the software. Caution: Use only factory supplied or authorized UPS monitoring kits! M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 5

6.3. Computer Interface Port The computer interface port has the following characteristics: The communication port on the back of the UPS may be connected to a host computer. This port allows the computer to monitor the status of the UPS and control the operation of the UPS. Its major functions include the following: 1. The ability to broadcast a warning when the power fails. 2. The ability to close any open files before the battery reserves are exhausted. 3. The ability to turn off the UPS. 4. The ability to make the UPS perform a self-test. Some computers are equipped with a serial connector to link with the communication port, in some cases a special plug-in card may be needed. RS-232 Communication 1. Pin 3 is the RS-232 data input from computer (RX) 2. Pin 2 is the RS-232 data output to computer (TX). 3. Pin 4 is the RS-232 (DTR) 4. Pin 7 is the RS-232 (RTS) 5. Pin 5 is the common or computer ground DB-9 Pin Configuration for the Limousin II 1 2 3 4 5 6 7 8 9 5 3 2 7 4 RS-232 RD (PIN 3) RS-232 TX (PIN 2) RS-232 RTS (PIN 7) RS-232 DTR (PIN 4) Ground (PIN 5) M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 6

7. BATTERY REPLACEMENT 1. Your battery should run anywhere from 3-5 years before it needs to be replaced. 2. Please follow the instructions below for easy, trouble free, battery replacement. 3. Turn the UPS off. Follow procedure previously mentioned. 4. Unplug the UPS from utility power source and disconnect all connected loads. 5. Disconnect AC power cord from unit. 6. Turn unit upside down. Using a Philips screwdriver, unscrew the four (4) screws holding the top of the unit to the bottom. Put screws in a safe place for reassembly. 7. Holding the top together firmly with the bottom, turn the entire unit right side up. 8. Carefully lift top cover off and place it to the side. The connecting wires and electronics will be exposed. CAUTION: Be careful not to touch any inner components of the Limousin UPS when changing the battery. Electrical shock hazards may be present. 9. Remove the two (2) connecting wires from the battery. 10. You can now easily remove the battery from the unit CAUTION: Do not dispose of battery in a fire. Do not attempt to open the battery. CAUTION: When replacing the battery, only use tools with insulated handles and remove metal jewelry like watches, rings, etc., to avoid risk of electrical shock and burns. 11. Place your new battery in the same position, direction and reconnect the wires. The red wire to the positive (+) pole and black wire to the negative (-) pole. 12. Reverse steps 5, 4 and 3 (in that order) to reassemble the unit. 13. Follow start-up instructions in order to properly reconnect your equipment. M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 7

8. TROUBLESHOOTING Please follow the guidelines below for common problems: Check UPS input plug and wiring. Check UPS input voltage. Please prepare the information as follows for service personnel: UPS model number and serial number Description of problem(s) in detail. 8.1. General Problems Problems Possible causes Solution UPS has no reaction while AC power from utility is connected UPS has no reaction while AC power is connected, yet starts after pushing power on/off switch UPS goes into back-up mode while connected to AC power Battery can not provide normal back-up power in the event of a blackout After AC connected to UPS, alarm sounds short and fast beeps and UPS shuts down Fuse at back panel open No AC input UPS fault Battery failure Fuse at back panel burnt No AC input UPS AC detecting circuit fail Check power cord Utility voltage or frequency abnormal UPS AC detecting circuit failure Battery deteriorated Batteries not fully charged Battery charger damaged Abnormal utility power Replace Fuse Check Utility AC power Call for service Call service center to replace batteries Replace fuse Check Utility AC power Call for service Check AC power Call for service Charge batteries and reset If that doesn t work call for service Check input power M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 8

9. SPECIFICATIONS GENERAL INPUT MODEL LIMOUSIN II Capacity 600VA UPC Order Code 825433 00111 Voltage 120V nominal (220V option), +/-25% Frequency 50 or 60Hz +/- 5% (auto sensing) Input socket (1) IEC 320 Voltage (on battery) 120VAC nominal +/-5% Simulated sine wave Frequency (on battery) 50 or 60Hz +/- 0.5% OUTPUT Auto Voltage Regulation +/-10% of nominal Waveform (on battery) Pulse Width Modulated (PWM) Transfer Time 4 milliseconds, including detection Receptacles (3) NEMA 5-15R (120V) Spike Protection 480 joules, 2ms PROTECTION Overload Protection and FILTERING 110% for 60 seconds and 130% for 3 seconds Short Circuit Fuse protection or immediate shutdown M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 9

Type Sealed, maintenance-free lead acid BATTERY Typical Recharge Time 6 hours (to 90% of full capacity) Back up Time 10-30 minutes Communications RS-232 INTERFACE LED Display Normal / Backup / Overload Audible Alarms On Battery, Low Battery, Overload Temperature range 0-40 o C ENVIRONMENT Humidity 0-95% non-condensing Audible Noise <40dBA (1 meter from surface) Safety cul, UL1778, CSA C22.2 SAFETY APPROVAL EMI / RFI FCC CLASS B Surge / Transient IEEE C62.41 CAT.A Net weight kg(lbs) 6.2(13.6) PHYSICAL DATA Shipping weight kg(lbs) 6.7(14.9) Dimension(mm)WxDxH 97x320x135 M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 10

10. CONTACT INFORMATION 10.1. Additional Purchases or Upgrades Always On UPS Systems Inc. 100 150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext 451 Fax: (250) 491-9775 Email: sales@alwaysonups.com Website: www.alwaysonups.com 10.2. QA / Warranty Questions Always On UPS Systems Inc. 100 150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext 209 Fax: (250) 491-9775 Email: qa@alwaysonups.com Website: www.alwaysonups.com 10.3. Software Questions Always On UPS Systems Inc. 100 150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext 204 Fax: (250) 491-9775 Email: webmaster@alwaysonups.com Website: www.alwaysonups.com M0601_Limo_II_Series_Manual V1.6 2012-06-12.doc 11