Operation and Maintenance Instructions for Bettis GVO-C Series GVO-CLP-SR Pneumatic Actuators

Similar documents
LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

METERING VALVE 2" STEM GUIDED

Baumann Mikroseal Control Valve

Disassembly / Reassembly Procedure

Pneumatic actuator Assembly & maintenance procedures

Baumann Sanitary Diaphragm Angle and Inline Control Valve

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

THD-SERIES S11DA280 THRU S27DA1020 & S11SR280 THRU S27SR1020 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER INJECTION PUMP

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

Disassembly and Reassembly for CBB (Double Acting) Series Pneumatic Actuators

Disassembly and Reassembly for CBB-SR (Spring Return) Series Pneumatic Actuators

Spring Brake Application

Installation, Operation, and Maintenance Instructions for Bettis RGS F-Series Spring-Return (SR) Actuators

Baumann Sanitary Angle Control Valve

PNEUMATIC ACTUATORS ASSEMBLY & MAINTENANCE PROCEDURES. Ref. Doc. MMMACTREGDRE English Rev.2 January 2012 ADA & ASR SERIES DOUBLE ACTING ACTUATOR ADA

Installation, Operation and Maintenance Manual RGS Rev. 0 November Bettis RGS F-Series Spring-Return Actuators

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

SERVICE INSTRUCTIONS FOR SEAL REPLACEMENT OF POWER GEAR HYDRAULIC LEVELING LEGS

STAINLESS STEEL SERIES LSSW HIGH PRESSURE HYDRAULIC CYLINDERS INSTALLATION & OPERATING INSTRUCTIONS

Fisher 685 Piston Actuator

Installation, Operation, and Maintenance Manual

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

Baumann Way Control Valve

1/2" AIR DRIVEN DIAPHRAGM PUMP

Maintenance Instructions & Parts List

SY-SERIES S04DA75 THRU S06DA180 & S04SR75 THRU S06SR180 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

Baumann Series Flexsleev Control Valve Instructions

OPERATION AND PARTS MANUAL

SERVICE INSTRUCTIONS ASSEMBLY & DISASSEMBLY T50X DOUBLE ACTING HYDRAULIC SERIES ACTUATORS

Fisher RSS Lined Globe Valve

Bettis M11 Manual Hydraulic Override System Operating Instructions for HD, T, and G Series Pneumatic and Hydraulic Actuators

Fisher RSS Lined Globe Valve

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

MANUAL - PNEUMATIC ACTUATORS, SERIES DA & SR - 1 -

Full View Flow Indicator

Fisher TBX Hydro Plug Fixture

Fisher CVX Hydro Plug Fixture

GH-BETTIS SERVICE INSTRUCTIONS DISASSEMBLY & REASSEMBLY FOR MODELS HD521-M4, HD721-M4 AND HD731-M4 DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

OPERATION AND PARTS MANUAL

Actuator Maintenance Manual, E-Type size 8 to 150

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

Technical Manual MSI Hydraulic Adjustable Choke

RAP R10: Air Relay Valve Service and Adjustment ARV-69626/ /05/11. Air Relay Valve Service and Adjustment

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Baumann Sanitary Diaphragm Angle & In-Line Control Valve Instructions

Operation & Service Manual

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

Fisher ENVIRO SEAL Packing System for Rotary Valves

INSTALLATION & MAINTENANCE MANUAL

HIGH PRESSURE CONTROL VALVE R2L ACTUATOR

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

Service Manual. #19 Gearmatic Winch

INSTALLATION INSTRUCTIONS REPAIR SEAL KIT PowerSurvivor 160E

Series 820 AWWA Butterfly Valves

Torque-Hub Planetary Final Drive S12A1 & 2 Series Service Manual

Fisher 685SE and 685SR Piston Actuator

Anderson Greenwood Single Active SSV Installation and Maintenance Instructions

IOM Manual. IOM Manual. Series 20/21.

RAP H10: Accumulator Seal Replacement Instructions HPU/ASRI (Parts & Service: Accum Seal) 05/09/11. Accumulator Seal Replacement Instructions

MAINTENANCE MANUAL DS3 DOUBLE SHEAR LOCKOUT UNIT

Baumann 24000F Wafer Control Valve

INSTALLATION MANUAL. MB-180, MB-210 and MB-210L Motor Brake INSTALLATION. Force Control Industries, Inc. DESCRIPTION OPERATION

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

Connectors for Diagnostic Testing with the FlowScanner Valve Diagnostic System

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR SPRING RETURN SERIES PNEUMATIC ACTUATORS

Operating & Maintenance Manual For Steam Conditioning Valve

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).

DelTorq Series 21 ACTUATOR

ONYX VALVE CO MODEL CER with JORDAN ACTUATOR Installation & Maintenance

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB DOUBLE ACTING SERIES PNEUMATIC ACTUATORS

Installation, Operation and Maintenance Manual HP/DHV Rev. 1 November Shafer Hand Pump-Double Holding Valve

INSTALLATION INSTRUCTIONS REPAIR SEAL KIT PowerSurvivor 40E

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

Keystone Butterfly valves ParaSeal Installation and maintenance instructions

Val-Matic 3-72 Cam-Centric Plug Valve

OPERATION AND MAINTENANCE INSTRUCTIONS

EC4 SERIES CRYOGENIC VALVES 1/4 2 Sizes

Sampling Valves - Yarway Model 56 / Narvik Model 36 Installation and Maintenance Instructions

Mounting and Operating Instructions EB 8222 EN. Type 3310/AT and Type 3310/3278 Pneumatic Control Valves. Type 3310 Segmented Ball Valve

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

ACTO 400 to MAINTENANCE

Yarway 7100 Series ARC Valve non-filtered design Installation and maintenance instructions

DelTech Controls L.L.C.

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS

Baumann Little Scotty Bronze Control Valve

Model DF233 Control Valve

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

SAFETY RELATED MANDATORY OUTRIGGER CYLINDER INSPECTION AND REPAIR

Cylinder Maintenance & Repair Instructions

Model DF269 Control Valve

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators

ONYX VALVE CO MODEL CER and CEP Installation & Maintenance

Purging Air From Divider Block Lubrication Systems

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

Transcription:

Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 Release: March 2016 Operation and Maintenance Instructions for Bettis GVO-C Series GVO-CLP-SR Pneumatic Actuators

Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 Table of Contents March 2016 Table of Contents Section 1: Introduction... 1 Section 2: Operation... 2 Section 3: Maintenance... 3 3.1 Inspection of Gland and Barrel Seals... 3 3.2 Inspection of Piston Seals... 3 Section 4: Seal Replacement... 4 4.1 Fail-Close Actuators... 4 4.2 Fail-Open Actuators... 5 4.3 Reassembling the Actuator... 6 Section 5: Seal-Kit Selection... 8 Section 6: Storage Condition... 9 Table of Contents I

Section 1: Introduction Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 March 2016 Section 1: Introduction Bettis GVO-C Linear valve actuator has been designed to meet a wide variety of applications. It has been manufactured to close tolerances and specifications and has been factory inspected and tested prior to shipment. Each actuator is identified with a unique serial number for reference when ordering replacement parts. The actuators have a special feature: they are single-acting, spring-return, to provide Fail-Close or Fail-Open action in case of loss of air pressure or electrical power. The springs are located in a factory sealed canister, easy to remove and provide high safety standards during the operation and maintenance. Each actuator was engineered to meet and exceed your specific application requirements. The following guidelines are designed to help you with your maintenance procedures. Introduction 1

Section 2: Operation March 2016 Service Instructions Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 Section 2: Operation 1. Use only filtered, pressure regulated and lubricated air to operate the actuator. The air must be filtered to remove all contaminants in excess of 30 microns particle size. Lubrication is recommended to reduce component friction and maximize seal life. Use ESSO-NUTO H-32 oil (or equivalent, compatible with seal materials). 2. Care must be exercised to ensure that operating pressure does not exceed the maximum rating of 150 psi. 3. Unless equipped with optional metallic rod-scraper and rod boot, the cylinder should be operated in an environment free of excessive dust and abrasive particles. 4. Standard operating temperature is between 30 C and +120 C ( 25 F and +250 F) unless specially equipped with high or low temperature seals. 5. For cylinders used in environments where the ambient temperature can drop below freezing point, only instrumental air, with Dew point 50 C ( 58 F) must be used. Lubrication is not recommended for such application. 2 Operation

Section 3: Maintenance Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 March 2016 Section 3: Maintenance Bettis GVO-C Linear actuator has been designed to give you trouble free performance with a minimum of maintenance. Periodic inspection and replacement of seals, when required, is recommended in order to ensure continued product safety and reliability. Inspection and seal replacement intervals depend on your specific operating conditions. The AS-Series actuators are specifically design for single action. 3.1 Inspection of Gland and Barrel Seals 1. Identify if the cylinder is a Fail-Close or Fail-Open type. The Fail-Close actuator has the pressure port at the rod end cap; the Fail-Open actuator has the pressure port located on the canister end cap. 2. Connect pressure line at the pressure port of the cylinder. 3. Apply Leak-Tek or similar soapy solution to the gland bushing end caps barrel juncture and inspect for signs of leakage. 3.2 Inspection of Piston Seals 1. Connect pressure line at the pressure port to allow actuator rod to fully extend or retract. 2. Install a pressure gauge at the opposite port and monitor reading for approximately 30 seconds. If the pressure reading remains at zero, piston seals performed properly. If a pressure rise is observed, seals should be replaced immediately. Maintenance 3

Section 4: Seal Replacement March 2016 Service Instructions Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 Section 4: Seal Replacement 1. Make sure line pressure is shut off before disconnecting actuator from the valve. 2. Remove the actuator to a clean working area. Remove all accessories installed on the cylinder (solenoid valves, filter-regulators, manual override jacks, and others). 3. Before proceeding at the seals replacement, the canister must first be removed from the cylinder. 4.1 Fail-Close Actuators 1. Unscrew the mounting bolts attaching the canister to the cylinder. This operation can be done in all safety, without any special precaution. The spring is contained in a factory sealed canister. 2. Remove the canister from the cylinder. 3. Unscrew the tie rod nuts and remove the tie rods. 4. Remove the cylinder rod end cap. 5. Pull the piston and piston rod assembly from barrel. Take care not to damage the rod and the barrel. Do not disassemble the rod from the piston replacement parts. 6. Unscrew the gland bushing from rod end cap. 7. Remove seals from piston and gland bushing, noting orientation of seal edges. The U-cups lips must face the pressure direction. Remove barrel O-rings from end caps grooves. 8. Verify barrel bore, gland bushing and rod surface for scratches or scoring, damage or excessive wear. 9. Replace piston rod assembly and/or gland bushing if damaged. Contact factory for replacement parts. 4 Seal Replacement

Section 4: Seal Replacement Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 March 2016 4.2 Fail-Open Actuators 1. Remove the protective cover located on the canister top end. 2. Unscrew the nut attaching the shaft to the top spring guiding piston. 3. Unscrew the mounting bolts attaching the canister to the cylinder. This operation can be done in all safety, without any special precaution. The spring is contained in a factory sealed canister. 4. Remove the canister from the cylinder. 5. Unscrew the tie rod nuts and remove the tie rods. 6. Remove the cylinder head (rod end cap). 7. Pull the piston and piston rod assembly from barrel. Take care not to damage the rod and the barrel. Do not disassemble the rod from the piston. 8. Unscrew the gland bushing from rod end cap. 9. Remove seals from piston and gland bushing, noting orientation of seal edges. The U-cups lips must face the pressure direction. Remove barrel O-rings from end caps grooves. 10. Verify barrel bore, gland bushing and rod surface for scratches or scoring, damage or excessive wear. 11. Replace piston rod assembly and/or gland bushing if damaged. Contact factory for replacement parts. Seal Replacement 5

Section 4: Seal Replacement March 2016 Service Instructions Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 4.3 Reassembling the Actuator 1. Carefully clean all components, grooves and surfaces prior to reassembly. Use compressed air to remove all solid particles. 2. Apply a light coat of grease (ESSO LIDOK EP2 or equivalent) to all packing and seal grooves. 3. Place O-rings in appropriate head and cap grooves. 4. Install piston seals. The U-cups must face pressure direction. 5. Install wear-band(s) on piston. 6. Slide piston and piston rod assembly into barrel. Take care not to damage seals. 7. Install gland seals, back-up rings and rod wiper in gland bushing. 8. Push gland bushing pilot diameter into actuator head. Tap with a rubber mallet, if necessary, to overcome resistance caused by O-ring. 9. Thread the bushing flange flush with actuator head. Tighten until snug. 10. Install cap on barrel. Ensure that barrel seal (O-ring) is properly seated in groove. 11. Slide actuator head over the piston rod and seat against barrel end. Make sure that bushing and barrel seals remain properly seated. 12. Install tie rods and hand tighten nuts. Make sure that head and cap are properly aligned. 13. Tighten tie rod nuts in cross sequence shown in Figure 1. Torque to values shown in Table 1. 14. Install the canister; secure it with mounting bolts. If the cylinder is Fail-Open, screw and tighten the nut connecting the shaft to the top spring guide piston. 15. Install the protective cover on top of the canister. 6 Seal Replacement

Section 4: Seal Replacement Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 March 2016 Figure 1 Tie Rod Nut Torquing Sequence Table 1. Torque Values Cylinder Bore (Inches) Number of Tie Rods Diameter of Tie Rods (Inches) Torque (lb-ft) (No Lubrication) 4 4 3/8 15 5 4 1/2 25 6 4 1/2 30 7 4 5/8 35 8 4 5/8 60 10 4 3/4 90 12 4 3/4 125 14 4 7/8 150 16 6 7/8 150 18 6 7/8 180 20 10 7/8 150 22 10 7/8 180 24 10 7/8 200 26 12 7/8 150 28 14 7/8 150 30 14 7/8 200 Seal Replacement 7

Section 5: Seal-Kit Selection March 2016 Service Instructions Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 Section 5: Seal-Kit Selection Use genuine parts only to ensure proper fit and function for continuous trouble free operation. In order to supply you with the appropriate seal-kit for your actuator, we require the part number and the serial number shown on the identification tag located on the barrel of the actuator. 8 Seal-Kit Selection

Section 6: Storage Condition Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 March 2016 Section 6: Storage Condition Bettis GVO-C Linear pneumatic valve actuators are shipped pre-lubricated, with exposed machined parts protected against corrosion. Piston rods and extended tie rods are protected against physical damage with polyurethane mesh sleeving. Air supply ports are protected with plastic cap plugs. All actuators are ready to use when they are shipped from factory. If the actuators must be stored before installation for a period of time, following storage conditions are required: 1. Actuators must be stored indoors. 2. Actuators must be stored in vertical position to prevent packing deformation. 3. Ambient storage temperature: 20 C to +40 C ( 4 F to +104 F). 4. Humidity: maximum 60%. 5. Do not remove protective cap plugs or protective covers. 6. Apply every 6 months a thin layer of metal protective coating on all machined exposed parts (threads). Before installation and start-up, following steps must be taken: 1. Remove all protective plastic plugs from air supply ports. 2. Spray a small amount (approximately 10 ml) of clean mineral petroleum based oil into the air supply ports. 3. Run the actuator for 8 to 10 dry cycles (piston rod free, without being connected to any device). Storage Condition 9

The contents of this publication are presented for information purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifications of our products at any time without notice.