Throttle valve and shut-off valve type CAV

Similar documents
Throttle valve and throttle check valve type CQ, CQR and CQV

Shut-off valve type AVT and AVM

Throttle valve type ED, throttle restrictor check valve type RD and RDF

Flow control valve type SJ

Check valve type ER and EK

Releasable check valve type RH

Releasable check valve type HRP

Flow divider, type TQ

Check valve type ER and EK

Releasable twin check valve type DRH

Valve bank type BNG. Product documentation. Manifold mounting Operating pressure p max : Flow rate Q max : 400 bar 60 lpm D 7788 BNG

Pressure controlled the 2-way directional valve type CNE

Check valves type CRK, CRB and CRH to screw-in into simple to manufacture tapped holes

Pump element type MPE and PE for radial piston pumps

Check valve type ER and EK

Valve bank (directional seated valve) type BVH

Releasable twin check valve type DRH

Connection blocks type AX, ASX, AVX and APX

Variable displacement axial piston pump type V80M

Direct current compact hydraulic power pack type NPC

Directional spool valves type SWPN

Variable displacement axial piston pump type V80M

Variable displacement axial piston pump type V60N

Valve bank (nominal size 6) type BA

Proportional directional spool valve type EDL

Proportional pressure reducing valve type KFB 01 (hydraulic joystick)

Variable displacement axial piston pump type V30E

Hydraulically pilot operated cartridge check valves Type RHC and RHCE without and with hydraulic pre-relief

Proportional, solenoid actuated flow control valves type SE and SEH

Intermediate plate type NZP hole pattern conforming NG 6 (DIN A6)

4/3- and 3/3-way directional seated valves type VH (R) and VHP

Discontinued type. 4/3-way proportional pressure reducing valve type FB and KFB (pilot valves)

Variable displacement axial piston pump type V60N

Prop. directional seated valve type EM 21 DE and EM 21 DSE intended as pilot valve

Directional spool valve type SG and SP

Proportional pressure limiting valve Type PMV and PMVP Type PMVS and PMVPS (with external control oil inlet)

Connection blocks type HMP with integrated lifting and lowering function for proportional spool valves type PSL and PSV, size 2 and 3

Lifting / Lowering valve type HSV and HZV

Proportional directional spool valve type EDL

Load-holding valves type LHDV

Variable displacement axial piston pump type V30E

Lifting / Lowering valve type HSV

These 2/2-way directional cone seated valves show zero leakage while in blocked shifting position. The following versions are available:

Operating manual. General operating instructions: Assembly, commissioning and maintenance B

Double throttle check valve Type Z2FS 10

Clamping modules type SMD 2 and NSMD 2 for actuating hydraulic clamping devices

Throttle and throttle check valve

Directional spool valve type SG and SP

Axial piston variable displacement pump type V60N, Serie 03

Pressure Relief Valve DB12 CE

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Pressure reducing valve, pilot operated

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Toothed belt axis ELGC-TB-KF. Operating instruction [ ]

Internal Gear Pumps Installation Manual

Installation and operating manual

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

2-way flow control valve

Spare Parts List Return Line Filter RFM with 4-hole attachment

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Workholding. Machining center clamping Clamping fixtures Welding fixtures Fully integrated systems. Product information

Check valve cartridge Type M-SR

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure reducing valve, direct operated

Check valve, pilot operated

Axial piston variable displacement pump type V60N

Spare parts list Return line filter RFM with 2-hole attachment

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Type 400LDN0040 to 1000; 400LD0130, 0150

Twin throttle check valve

Ball valve for pipeline systems

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Block mounting filter, for sandwich plate mounting

Pipe burst safety valve

Vane Air Motors - P1V-B

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Spare Parts List Return line filter RF

Flow Control Valves and Flow Control Valves with reverse flow check DV/DRV

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Pressure relief valve, pilot operated

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

Safety Shock Absorbers SCS33 to SCS64

Pressure relief valve, pilot operated

Exchange of rollers from the XTS-Mover

LHW-3P Load Holding Valve Winch

Mini slide EGSC-BS-KF. Operating instructions b [ ]

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

FLOW CONTROL VALVES F CONTROL VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.] Maximum flow rate L/min. Page

1/2" AIR DRIVEN DIAPHRAGM PUMP

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Line filter with filter element according to DIN 24550

Spindle axis ELGC-BS-KF. Operating instructions [ ]

Variable displacement axial piston pump type V30D

Pressure Compensated Flow Control Valves SRVR/SRVRP

Proportional pressure relief valve, directly operated, rising characteristic curve

IMPORTANT SAFETY NOTICE

Transcription:

Throttle valve and shut-off valve type CAV Product documentation Screw-in valve Operating pressure pmax: Flow rate Qmax: 500 bar 50 lpm D 7711 07-2016-1.1

by HAWE Hydraulik SE. The forwarding and reproduction of this document, as well as the use and communication of its contents, are forbidden unless expressely permitted. Any breach or infringement will result in liability for damages. All rights reserved concerning patent or utility model application. 2/14 D 7711 - CAV - 07-2016-1.1 HAWE Hydraulik SE

Contents 1 Throttle valve and shut-off valve type CAV overview...4 2 Available versions, main data... 5 2.1 Screw-in valve... 5 2.2 Version for pipe connection... 6 3 Parameters... 7 4 Dimensions... 9 4.1 Screw-in valve... 9 4.2 Version for pipe connection...10 5 Assembly, operation and maintenance recommendations...11 5.1 Intended application... 11 5.2 Assembly information... 11 5.2.1 Screwing in and locking...12 5.2.2 Adjusting version CAV..K... 12 5.2.3 Tapped plugs... 13 5.2.4 Creating the mounting hole...13 5.3 Operating instructions...14 5.4 Maintenance information...14 HAWE Hydraulik SE D 7711 - CAV - 07-2016-1.1 3/14

1 Throttle valve and shut-off valve type CAV overview Throttle and shut-off valves are a type of metering valve. With the aid of these valves a pressure drop can be established between the inlet and outlet side. In this way the velocity of cylinders in accumulator circuits and the ow rate in control circuits can be regulated or a consumer line completely shut-off (e.g. to protect a pressure gauge). The throttle and shut-off valve type CAV, as a slotted throttle, is insensitive to micro contamination. It can be screwed-in and can be integrated into control blocks. The necessary mounting holes are straightforward to make. Features and bene ts: Various configurations Sensitive adjustment and complete shut off possible Intended applications: General hydraulic systems Turn knob Manually adjustable version Fixed (locked) version 4/14 D 7711 - CAV - 07-2016-1.1 HAWE Hydraulik SE

2 Available versions, main data Circuit symbol: CAV..(K) CAV..R(K) CAV..V(K) 2.1 Screw-in valve Order coding example: CAV 2R CAV 1V K Adjustment Basic type and size Table 2 Adjustment Table 1 Basic type and size Table 1 Basic type and size Basic type and size Description Pressure range p max (bar) Flow rate Q max approx. (lpm) CAV 1 Throttle and locking direction A d B and 30 M16x1.5 CAV 2 B d A 50 M20x1.5 CAV 1R Throttle and locking direction B d A, free 15 M16x1.5 500 CAV 2R A d B 25 M20x1.5 CAV 1V Throttle and locking direction A d B, free 15 M16x1.5 CAV 2V B d A 25 M20x1.5 Spigot screw thread, metric ISO ne thread DIN 13 T6 Table 2 Adjustment Marking None K D Description Standard, with wing nut Fixed, (locked version) tool adjustable, see Chapter 5.2.2, "Adjusting version CAV..K" Turn knob HAWE Hydraulik SE D 7711 - CAV - 07-2016-1.1 5/14

2.2 Version for pipe connection Order coding example: CAV 1V K - 1/4 Connection block Table 3 Connection block Type Type according to Chapter 2.1, "Screw-in valve" Note Only for type CAV 1 Table 3 Connection block Marking - 1/4 G 1/4-3/8 G 3/8 Connections A, B (BSPP) 6/14 D 7711 - CAV - 07-2016-1.1 HAWE Hydraulik SE

3 Parameters General information Description Design Model Material Tightening torques Installation position Flow direction Closed position Throttle valve and shut-off valve for screwing in Slotted throttle, with and without bypass check valve depending on type Screw-in valve, pipe connection Steel; nitrided valve housing, electrogalvanised sealing nuts and connection block, hardened and ground functional inner parts For screwing into a basic body made of steel, spheroidal casting or other materials (e.g. aluminium) See Chapter 4, "Dimensions" As desired As desired; locked, throttled or free, see circuit symbol, table 1 Chapter 2, "Available versions, main data" CAV.. zero-leakage when throttle completely closed B d A (CAV..R..) and A d B (CAV..V..) not zero-leakage when throttle completely closed Hydraulic uid Hydraulic oil: according to Part 1 to 3; ISO VG 10 to 68 according to DIN ISO 3448 Viscosity limits: min. approx. 4, max. approx. 1500 mm 2 /s opt. operation approx. 10... 500 mm 2 /s. Also suitable for biologically degradable hydraulic uids type HEPG (polyalkylene glycol) and HEES (synthetic ester) at operating temperatures up to approx. +70 C. Cleanliness level ISO 4406 21/18/15...19/17/13 Temperatures Ambient: approx. -40... +80 C, Fluid: -25... +80 C, Note the viscosity range! Permissible temperature during start: -40 C (observe start-viscosity!), as long as the service temperature is at least 20K higher for the following operation. Biologically degradable pressure uids: Observe manufacturer's specifications. By consideration of the compatibility with seal material not over +70 C. HAWE Hydraulik SE D 7711 - CAV - 07-2016-1.1 7/14

Pressure and ow rate Operating pressure Static overload capacity p max = 500 bar approx. 2 x p max when tightened and locked with a sealing nut Opening pressure Type CAV 1(2) R approx. 0.2... 0.4 bar A - B Type CAV 1(2) V 0 bar B - A (unloaded valve plate) Weight Type CAV 1.. CAV 2.. = 50 g = 70 g Connection blocks - 1/4-3/8 = +260 g = +260 g Characteristic curves Oil viscosity approx. 60 mm 2 /s Δp-Q characteristics Throttle characteristics Reference values per revolution of the adjusting spindle counted from the lock-out circuit Free ow direction Q ow rate (lpm); Sp ow resistance (bar) 1 1 revolution 2 2 revolution 3 3 revolution 8/14 D 7711 - CAV - 07-2016-1.1 HAWE Hydraulik SE

4 Dimensions All dimensions in mm, subject to change. 4.1 Screw-in valve CAV 1... CAV 2... CAV 1...K CAV 2...K CAV 1...D CAV 2...D 1 O-ring 2 Fitting seal 3 Sealing edge 4 Sealing nut 5 Stopper 6 Valve housing Mounting hole Type #D #D 1 a #d #d 1 l l 1 l 2 l 3 t t 1 t 2 G CAV 1.. 22 8 35 2 4.5 37 18 24 17 13 11 18 M16x1.5 CAV 2.. 24 10 45 3 6 43 22 29 21 14 13 20 M20x1.5 Fitting seal O-ring AU 90 Sh Type SW1 SW2 SW3 Tightening torque (Nm) Counterbore Housing Sealing nut #B max CAV 1.. 17 22 10 40 35 16 +0.2 KANTSEAL DKAR00016-N90 14x1.78 CAV 2.. 22 24 11 50 40 20 +0.2 KANTSEAL DKAR00018-N90 17.17x1.78 HAWE Hydraulik SE D 7711 - CAV - 07-2016-1.1 9/14

4.2 Version for pipe connection CAV 1... -1/4 CAV 1... -3/8 Connections A, B (BSPP) - 1/4 = G 1/4-3/8 = G 3/8 10/14 D 7711 - CAV - 07-2016-1.1 HAWE Hydraulik SE

5 Assembly, operation and maintenance recommendations 5.1 Intended application This valve is intended exclusively for hydraulic applications ( uid engineering). The valve meets high technical safety standards and regulations for uid. The user must observe the safety measures and warnings in this documentation. Essential requirements for the product to function correctly and safely: All information in this documentation must be observed. This applies in particular to all safety measures and warnings. The product must only be assembled and put into operation by quali ed personnel. The product must only be operated within the speci ed technical parameters. The technical parameters are described in detail in this documentation. The operating and maintenance manual of the speci c complete system must also always be observed. If the product can no longer be operated safely: Remove the product from operation and mark it accordingly. It is then not permitted to continue using or operating the product. 5.2 Assembly information The product must only be installed in the complete system with standard connection components that comply with market requirements (screw ttings, hoses, pipes, etc.). The hydraulic system must be shut down correctly prior to dismounting; this applies in particular to hydraulic systems with hydraulic accumulators. Danger Risk to life caused by sudden movement of the hydraulic drives when dismantled incorrectly! Risk of serious injury or death. Depressurise the hydraulic system. Perform safety measures in preparation for maintenance. HAWE Hydraulik SE D 7711 - CAV - 07-2016-1.1 11/14

5.2.1 Screwing in and locking 1. in the valve, loosen the lock nut and sealing nut until the travel stop. 2. Screw in the valve and tighten to the speci ed torque. The metallic sealing of the inlet to the outlet is formed between the facial sealing edge of the valve and the shoulder of the stepped hole in the basic body. 3. counter/sealing nut to the speci ed torque. 1 Valve housing 2 Locking 3 Sealing edge 4 Basic body 5 Lock nuts and sealing nuts 6 Stopper Basic type and size Valve housing Width across ats SW1 Tightening torque (Nm) Lock nuts and sealing nuts Width across ats SW2 Tightening torque (Nm) CAV 1.. 17 40 22 35 CAV 2.. 22 50 24 40 SW = a/f 5.2.2 Adjusting version CAV..K 1. Loosen the lock nut 2. Using the pin tool, turn the threaded spindle into drill hole #d Clockwise = throttling cross-section is reduced (Sp increases) Anti-clockwise = throttling cross-section (Sp decreases) 3. Tighten the lock nut after adjustment 1 Threaded spindle Basic type and size L Lock nut Width across ats SW3 Tightening torque (Nm) Threaded spindle Thread #d #d 1 max. CAV 1.. 17 10 15 M6 2 1.8 CAV 2.. 21 13 30 M8 3 2.8 SW = a/f 12/14 D 7711 - CAV - 07-2016-1.1 HAWE Hydraulik SE

5.2.3 Tapped plugs The mounting holes can be sealed with tapped plugs if necessary; for example, if the assembly of standardised basic bodies is to be carried out with or without screw-in valves as required. Passage open Passage blocked 1 Tapped plug 2 Sealing ring 1 Lock nuts and sealing nuts 2 Screw part 3 Tapped plug and locking tapped plug complete Type and size Passage open Tapped plug Sealing ring Passage blocked Tapped plug and locking tapped plug complete DIN 910 SW4 Tightening torque (Nm) Screw part DIN 7603-Cu Drawing no. SW5 Tightening torque (Nm) Lock nuts and sealing nuts SW6 Tightening torque (Nm) CAV 1.. M16x1.5 17 40 A16x22x1.5 Z 7712 003 8 40 22 35 CAV 2.. M20x1.5 19 50 A20x24x1.5 Z 7712 013 10 50 24 40 SW = a/f 5.2.4 Creating the mounting hole See description in Chapter 4, "Dimensions". HAWE Hydraulik SE D 7711 - CAV - 07-2016-1.1 13/14

5.3 Operating instructions Product configuration and setting the pressure and ow rate The statements and technical parameters in this documentation must be strictly observed. The instructions for the complete technical system must also always be followed. Note Read the documentation carefully before usage. The documentation must be accessible to the operating and maintenance staff at all times. Keep documentation up to date after every addition or update. Caution Risk of injury due to unexpected movement processes in the machine due to incorrect ow setting! Risk of minor injury Be prepared for unexpected, fast movements. On changing the ow settings, consumers will move more slowly or more quickly. Always monitor the pressure gauge when setting or changing the ow. Purity and ltering of the hydraulic uid Fine contamination can significantly impair the function of a hydraulic power pack. Contamination can cause irreparable damage. Examples of ne contamination include: Metal chips Rubber particles from hoses and seals Dirt due to assembly and maintenance Mechanical debris Chemical ageing of the hydraulic uid Note Fresh hydraulic uid from the drum does not always have the highest degree of purity. Under some circumstances the fresh hydraulic uid must be ltered before use. Pay attention to the cleanliness level of the hydraulic uid in order to maintain faultless operation. (Also see cleanliness level in Chapter 3, "Parameters".) 5.4 Maintenance information This product is largely maintenance-free. Check that the product is securely fastened in the mounting hole at regular intervals, but at least once per year. Conduct a visual inspection at regular intervals, but at least once per year, to check if the hydraulic connections are damaged. If external leakages are found, shut down and repair the system. Clean the device surface of dust deposits and dirt at regular intervals, but at least once per year. 14/14 D 7711 - CAV - 07-2016-1.1 HAWE Hydraulik SE

Further information Additional versions Pressure valve type CMV, CMVZ, CSV and CSVZ: D 7710 MV Pressure-controlled shut-off valve type CNE: D 7710 NE Check valve type CRK, CRB and CRH: D 7712 Throttle valve and throttle check valve type CQ, CQR and CQV: D 7713 Flow control valve type CSJ: D 7736 Pressure-reducing valve type CDK: D 7745 Pressure-dependent shut-off valve type CDSV: D 7876 Shut-off valve type AVT and AVM: D 7690 Throttle valve and shut-off valve type AV: D 4583 D 7711 - CAV - 07-2016-1.1 HAWE Hydraulik SE Streitfeldstraße 25 81673 München Postfach 80 08 04 81608 München Germany Tel +49 89 379100-1000 Fax +49 89 379100-91000 info@hawe.de www.hawe.com