Multi-layer pumps Flow capacity 55 l/h... 100 l/h 410.-...ML in survey Multi-layer technology High dosing accuracy Safe to run dry High quality materials Leakage-free Low maintenance User-friendly Integrable into automatic processes Manual stroke length Robust metallic stroke mechanism housing Infobox Order information Page.97 Options/accessories Page.97 fittings-allocation Page.100 connecting pieces Chapter 4 resistance chart Chapter 5 installation examples Chapter 5 Technical data Nominal capacity l/h Nominal stroke frequency 1/min Admiss. counterpressure Admiss. pressure at pump inlet Max. suction height Inlet/ Outlet nominal width Max. stroke length 50 Hz 60 Hz 50 Hz 60 Hz bar bar mwc DN mm kw R410.-55ML 0-55 0-66 76 9 16-0,3 / 0 3 10 8 0,75 R410.-70ML 0-70 0-84 97 116 16-0,3 / 0 3 15 8 0,75 R410.-105ML 0-105 0-16 76 9 15-0,3 / 0 3 15 10 0,75 R410.-135ML 0-135 0-16 97 116 15-0,3 / 0 3 15 10 0,75 R410.-400ML 0-400 0-480 76 9 10-0,3 / 0 3 15 13 0,75 0-500 0-600 97 116 10-0,3 / 0 3 15 13 0,75 R410.-940ML 0-950 0-118 76 9 5-0,3 / 0 3 0 0 1,5 0-100 - 97-5 -0,3 / 0 3 0 0 1,5 Note: The admissible counterpressure is 10 bar or lower when plastic pump bodies are used. rated motor power Dimensional drawing 115 S D H G L B Dimensional chart All indications in mm G S D L B H Weight (kg) R410.-55ML G 3/4 113 113 408 317 490 9 R410.-70ML G 3/4 113 113 408 317 490 9 R410.-105ML G 1 1/4 17 17 45 331 490 3 R410.-135ML G 1 1/4 17 17 45 331 490 3 R410.-400ML G 1 1/4 138 138 413 339 490 34 G 1 1/4 138 138 413 339 490 34 R410.-940ML G 1 1/4 16 16 457 355 55 38,5 G 1 1/4 16 16 457 355 55 38,5 Indication of weight for basic design acc. to order information.96
Order information Single valve PP-FRP optical -rupture indication 0-40/380-40 V +/- 5% threephase, Multi-layer pumps Flow capacity 55 l/h... 100 l/h R410.-55ML 16013364 R410.-70ML 16013365 R410.-105ML 16013366 R410.-135ML 16013367 R410.-400ML 16013368 16013369 R410.-940ML 16013370 16013371 Pump body and valves R410.-55ML R410.-70ML R410.-105ML R410.-135ML R410.-400ML R410.-940ML PP Single valve PP-FRP l l l l PVC-U Single valve PVC-U Single valve -GFK 1.4571 Single valve 1.4571/1.4581 s s s Double valve 1.4571/1.4581 Valve balls Glass Single valve l l l l Single valve PVC-U m s s s 1.4401 Single valve m s s s Double valve m s s s PTFE Single valve Double valve Valve seals FPM Single valve l l l l EPDM Single valve m m m m Double valve m m m m Diaphragm rupture monitoring FEP-umm. Single valve Double valve optical rupture indicator l l l l Pressure switch IP 65 Pressure switch IIG EExd IIC T5 or T6 acc. to ATEX95 Stroke length with position indicator Stroke frequency monitoring Inductive-contact 10-60 V DC, three-wire, PNP Namur execution, IIG EExia IICT6 acc. to ATEX95.97
Multi-layer pumps Flow capacity 55 l/h... 100 l/h Order information Single valve PP-FRP optical -rupture indication 0-40/380-40 V +/- 5% threephase, R410.-55ML 16013364 R410.-70ML 16013365 R410.-105ML 16013366 R410.-135ML 16013367 R410.-400ML 16013368 16013369 R410.-940ML 16013370 16013371 R410.-55ML R410.-70ML R410.-105ML R410.-135ML R410.-400ML R410.-940ML Drive motor Special voltage Enclosure IP 65 Protective roof for the fan of the drive integrated posistor (3 pcs.) insul. cl. F VIK-design IIG EExe IIT4 (acc. to ATEX95) IIG EExde IICT4 (acc. to ATEX95) Single phase AC 30V with capacitor Stroke length Driver for converter operation incl. integrated posistor, 5-50/60Hz Driver for converter operation IIG EExde IICT4, 5-50/60 Hz acc. ATEX 95, incl. integrated posistor Actuator N C1-BA 30 V, +/- 10%, 50/60 Hz, 18s/10 U, 1,5 Nm incl. mounting plate for actuator Electronic positioning controller PMR3 input signal 0/4-0 ma incl. feedback signal 0/4-0 ma (only in N C1-BA integrated) Actuator D30D-10-Ex (IIG EExde IICT4) acc. to ATEX 95, 400 V, 50 Hz, 10 U/min, incl. mounting-kit for actuator and base plate Stroke frequency Frequency converter series 800 Motec mounted-on, input 4-0mA Single-phase 30 V, 50/60 Hz Three-phase 30-550 V, +/- 0%, 50/60 Hz Switch-potentiometer for manuell stroke frequency and to switch on the pump motor (External control of the frequency converter with mounted switch potentiometer unit is not possible) Service module hand terminal and keypad incl.,5m connection cable 0,37 kw s s s 0,37 kw s.98
Order information Single valves PP-FRP optical -rupture indication 0-40/380-40 V +/- 5% threephase, Multi-layer pumps Flow capacity 55 l/h... 100 l/h R410.-55ML 16013364 R410.-70ML 16013365 R410.-105ML 16013366 R410.-135ML 16013367 R410.-400ML 16013368 16013369 R410.-940ML 16013370 16013371 Stroke frequency Frequency converter series 800 Motec mounted-on, input 4-0mA Single-phase 30 V, 50/60 Hz R410.-55ML R410.-70ML R410.-105ML R410.-135ML R410.-400ML R410.-940ML 0,75 kw 9001754 9001754 9001754 1,5 kw 90018865 Three-phase 30-550 V, +/- 0%, 50/60 Hz 0,75 kw 9001757 9001757 9001757 1,5 kw 9001758 Console 1.4301 9003876 9003876 9003876 9003876 for wall mounting incl. fixing screws PP 9003849 9003849 9003849 9003849.99
Multi-layer pump Flow capacity 55 l/h... 100 l/h Admissible counterpressure up to 16 bar R410.-55ML R410.-75ML R410.-105ML R410.-135ML R410.-400ML R410.-940ML P. P. P. P. P. P. Pulsation damper without separating Suction lance Priming aid / Siphon vessel PVC-U / PP 70.1 3.14 70.1 3.14 70.1 3.14 70.1 3.14 70.1 3.14 70.1 3.14 1.4571 & & & & & & with level switch 1-stage without level switch PVC-U transparent SL-0 3.36 SL-0 3.36 SLP- 151.1 3.4 S-03 3.38 S-03 3.38 S-01 3.46 S-01 3.46 S-01 3.46 S-01 3.46 S-01 3.46 S-01 3.46 770. 3.78 770. 3.76 770. 3.76 770. 3.76 770. 3.76 770. 3.76 Calibration pot PVC-U 79.1 3.78 79.1 3.78 79.1 3.78 794.1 3.78 795.1 3.78 795.1 3.78 PVC-U 731 3.8 731 3.8 73. 3.80 73. 3.80 73. 3.80 73. 3.80 PP / 73 3.8 73 3.8 73 3.8 73 3.8 Foot valve 1.4571 731 3.8 731 3.8 73 3.8 73 3.8 73 3.8 73 3.8 -FRP 781.1 3.86 781.1 3.86 783.1 3.86 783.1 3.86 783.1 3.86 783.1 3.86 75.1 3.88 75.1 3.88 75.1 3.88 75.1 3.88 75.1 3.88 75.1 3.88 Line strainer 1.4408 75 3.90 75 3.90 75 3.90 75 3.90 75 3.90 75 3.90 PVC-U 751.1 3.88 751.1 3.88 Float valve PVC-U 871 3.9 871 3.9 87 3.9 87 3.9 87 3.9 87 3.9 Fittings for the pressure side of dosing pumps R410.-55ML R410. -75ML R410.-105ML R410.-135ML R410.-400ML R410.-940ML P. P. P. P. P. P. Diaphragm-type relief valve 60.10 3.4 60.10 3.4 6.10 3.4 6.10 3.4 6.10 3.4 63.10 3.4 Diaphragm-type pressure keeping valve 60.D 3.8 60.D 3.8 6.D 3.8 6.D 3.8 6.D 3.8 6.D 3.8 Pulsation damper PVC-U / PP 70.1 3.14 70.1 3.14 70.1 3.14 70.1 3.14 70.1 3.14 703.1 3.14 without separating 1.4571 & & & & & & Diaphragm-pulsation damper with PTFE/PTFE-faced Check valve Dosing valve 71. 3.4 7.1 3.4 7.1 3.4 7.1 3.4 1.4571 71.1 3.6 7.1 3.6 7.1 3.6 7.1 3.6 1.4571 713.1 3.18 713.1 3.18 Diaphragm-pulsation damper with Elastomer 810.1-0,16/180 3.8 810.1-0,3/160 3.8 810.1-0,3/160 3.8 810.1-0,3/160 3.8 810.1-,0/100 3.8 810.1-,0/100 -FRP 661. 3.50 661. 3.50 663. 3.50 663. 3.50 663. 3.50 663. 3.50 1.4571 661. 3.50 661. 3.50 66. 3.50 66. 3.50 66. 3.50 663. 3.50 PVC-U 661. 3.50 661. 3.50 -FRP 691.1 3.54 691.1 3.54 693.1 3.54 693.1 3.54 693.1 3.54 693.1 3.54 1.4571 691.1 3.54 691.1 3.54 69.1 3.54 69.1 3.54 69.1 3.54 693.1 3.54 681.1 3.58 681.1 3.58 68.1 3.58 68.1 3.58 68.1 3.58 683.1 3.58 PVC-U 691.1 3.54 691.1 3.54 3.8 & = on request = not available The above allocation considers the fittings which have to be used at least regarding their nominal width in order to ensure the safe and troublefree operation of the respective pumps when feeding liquids which are similar to water. Absolutely note the max. admissible operating pressure of the fittings. The use of fittings of a bigger nominal width is unproblematically possible in most cases. When choosing the fittings note the installation instructions for dosing pumps or confer with sera..100