Medium Voltage Fuses

Similar documents
A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

A240R/A480R/A072F/A072B MED. VOLTAGE FUSES / R-RATED

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

CS-3 SERIES E-RATED/MEDIUM VOLTAGE FUSES

E-RATED/MEDIUM VOLTAGE FUSES

CL-14 SERIES E-RATED / MEDIUM VOLTAGE FUSES

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

Medium Voltage. Section Contents. Page. Introduction...100

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

IEC Standard Back-Up Fuse-Links

Low-Peak 600V Class RK1

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

Medium voltage fuses Medium voltage fuses

Product Selection Guide

3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

General Purpose US Fuses

Medium Voltage Metal-Enclosed Switches

Section Contents. Page. Introduction... 72

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Industrial Control Transformers

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

FX Full-Range Current-Limiting Fuse

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

SIEMENS. Current-Limiting Fuses. DESCRIPTION ceo '1 I. 2.4 and 4.8 Kv for Motor Starting Application. Type FM. Page 1 EFFECTIVE FEB..

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

High Speed Fuses. Section Contents Page

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

TA Ta VA CTRL-XFRMR

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Recommended Procedures

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

NX indoor current-limiting fuses

Protective Link Expulsion Fuse Type Prolink, Oil Immersed, PTAP-APR925 IZUA Technical Guide 15 kv, 23 kv, & 35 kv

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

26.3. Power Breakers, Contactors and Fuses. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents.



Each of these factors, as they apply to the selection of Types CLE and CLS current limiting fuses, is briefly outlined on the following pages.

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

Industry s most comprehensive medium voltage circuit protection

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Medium Voltage Metal-Enclosed Switches

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Specifications. S&C Type XS Fuse Cutouts. Outdoor Distribution (4.16 kv through 25 kv)

Midget & Electronic Fuses

6,3* 1,6 No Printed circuitboard Brass, Nickel plated MR 5-6 Y Yes Yes 5x20 &6x32

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

SECTION MOTOR CONTROL

Ampgard medium voltage motor control renewal parts

WIRING DESIGN & PROTECTION REQUIREMENTS CHECKLIST

Low Voltage Fuses For Motor Protection

www. ElectricalPartManuals. com

PT Medium voltage fuses for potential and small power transformers

S&C Recloser Bypass Disconnects

Bolted contact switches. Pringle switches

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

MAGNETIC MOTOR STARTERS

Elastimold. Cable Accessories. Underground Distribution Switchgear. Molded Vacuum Switches and Fault Interrupters

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1

Specialty. Product Guide

Application Information Need to know how? You ve turned to the right place...literally.

Gears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Bussmann series NH catalogue. Leadership in circuit protection

PROTECTION AND CONTROL

3.2. Current Limiting Fuses. Contents

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

DO-III Fuse Holder TPL , May 2000, Page 1 of 4. General Information on the DO-III Draw Out Load Break Expulsion Fuse Holder. ABB Inc.

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Padmount Solid Dielectric Switchgear Catalog

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Molded Current-Limiting Fuse

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Sapling 2-Wire Digital Communication System Line Drawing

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

Figure 1. Two and Three-phase MagneX.

Product Catalog Medium Voltage Fuses. Circuit Protection

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Fuses Special Purpose

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

TEMPERATURE RISE TESTS

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

Fuseology. Dual-Element, Time-Delay Fuse Operation

SWITCHGEAR DIVISION PRODUCT PROFILES

Power Break II Switchboard

Three-Phase Pole Mounted Recloser

Outdoor Distribution (15 kv through 25 kv) S&C Fault Tamer Fuse Limiter

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Disconnect & ByPass Switches

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Transcription:

2,400-38,000 VAC General Information Current-limiting E and rated fuses are equipped with a mechanical indicator or striker pin that protrudes through the fuse cap upon operation of the fuse. This provides visual identification of a blown fuse and can be used as a trigger for external devices. Note: Extension distance 1 /2 min; extension force 2lb. min The terms Medium Voltage and High Voltage have been used interchangeably by many people to describe fuses operating above 600 volts. Technically speaking, medium voltage fuses are those intended for the voltage range from 2,400 to 38,000 VAC. High voltage fuses are for circuits carrying voltages greater than 38,000 VAC. E rated fuses are considered to be general purpose fuses and can be used to protect against low and high values of fault current. rated fuses are designed for back-up protection. They must be used in series with other devices such as motor overload relays in order to achieve both overload and short-circuit protection. Littelfuse now offers a complete selection of E and rated medium voltage fuses for the protection of transformers, potential transformers, feeders, and motor circuits. Single, double, and triple barrel designs are available to cover a wide range of current, voltage, and interrupting ratings. Conventional ferrule type, clip lock, and bolt-in mounting configurations are now available for virtually any application. Hermetically sealed fuses for use in hazardous environments are also offered. Contact the factory or your local Littelfuse representative for additional fuse ratings or custom mounting configurations. Medium voltage fuses are not intended to provide overload protection in the same sense as fuses rated 600 volts or less. Medium voltage fuse current ratings do not have the same meanings as the ampere ratings of low voltage fuses. All medium voltage fuses are limited in their ability to interrupt low value overcurrents, especially those between 100% and 200% of the fuse s continuous current rating. They are designed to carry their rated current without exceeding the temperature rise permitted by NEMA and ANSI standards. Additional application data can be found in the Fuse Application section of this catalog. 24 Hour Emergency Service is available. Call 847 824 1188. Applications Power Transformer Protection Potential Transformer Protection Motor Controller Back-up Protection Fused Switches Feeder Circuits Bolt-in Mount Fuses 64 w w w. l i t t e l f u s e. c o m 2005 Littelfuse POW-GAD Products

ated Features rated fuses provide required short-circuit protection for medium voltage motors, motor controllers and associated circuitry. These components have limited ability to absorb the energy of large shortcircuit currents. Medium voltage motor controllers contain overload relays which provide both overload protection and locked rotor protection to the motor. The controllers are also intended to interrupt low value short-circuits within the capability of the motor controller. This protects the medium voltage fuse from sustained overcurrents which are less than their minimum interrupting rating. Characteristics Voltage ating: Current ange: Options 2,400 volts 8,250 volts 2 36 Hermitically sealed for use in hazardous locations (add S suffix to part number) Bolt-in mounting configurations NEMA Standards for rated medium voltage power fuses require they operate within 15-35 seconds when subjected to an rms current 100 times the rating. For example, a fuse with a 2 rating will open within 15 to 35 seconds on an applied current of 2 x 100 = 200 amperes. Part System 130-4-1C-5.5 Max Voltage (KV) Style (C-Cartridge) No. of Barrels ating (size) Hookeye Feature* * For hookeye attachment; add W suffix to part number 3"DIA 6.38" 9.75" Clip Center D DD DDD 1 2 3 ated 2.75 KV @ 40 deg C. Min. Interrupting ating MS Amps Max Interrupting ating MS Asym 70-2-1C-2.75 LCK 2 2 70 7" 10.875" 170 80,000 1 100-3-1C-2.75 LCK 3 3 100 7" 10.875" 250 80,000 1 130-4-1C-2.75 LCK 4 4 130 7" 10.875" 340 80,000 1 150-5-1C-2.75 LCK 5 5 150 7" 10.875" 390 80,000 1 170-6-1C-2.75 LCK 6 6 170 7" 10.875" 500 80,000 1 200-9-1C-2.75 LCK 9 9 200 7" 10.875" 760 80,000 1 230-12-1C-2.75 LCK 12 12 230 7" 10.875" 1000 80,000 1 390-18-2C-2.75 LCK 18 18 390 7" 10.875" 1500 80,000 2 450-24-2C-2.75 LCK 24 24 450 7" 10.875" 1950 80,000 2 Add w suffix to part number for hookeye attachment. 2005 Littelfuse POW-GAD Products w w w. l i t t e l f u s e. c o m 65

ated 3"DIA 6.38" 9.75" (Clip Center) D DD DDD 4 5 6 ated 14 Clip Centers @ 40 Degrees C Min. Interrupting ating MS Amps Max Interrupting ating MS (Asym) 70-2-1C-5.5 LCL 2 2 70 12" 15.875" 170 80,000 4 100-3-1C-5.5 LCL 3 3 100 12" 15.875" 250 80,000 4 130-4-1C-5.5 LCL 4 4 130 12" 15.875" 340 80,000 4 150-5-1C-5.5 LCL 5 5 150 12" 15.875" 390 80,000 4 170-6-1C-5.5 LCL 6 6 170 12" 15.875" 500 80,000 4 200-9-1C-5.5 LCL 9 9 200 12" 15.875" 760 80,000 4 230-12-1C-5.5 LCL 12 12 230 12" 15.875" 1000 80,000 4 390-18-2C-5.5 LCL 18 18 390 12" 15.875" 1500 80,000 5 450-24-2C-5.5 LCL 24 24 450 12" 15.875" 1950 80,000 5 480-26-2C-5.5 26 480 12" 15.875" 2100 80,000 5 550-30-2C-5.5 30 550 12" 15.875" 2400 80,000 5 600-32-2C-5.5 32 600 12" 15.875" 2600 80,000 5 650-36-2C-5.5 36 650 12" 15.875" 2900 80,000 5 550-30-3C-5.5 30 550 12" 15.875" 2400 80,000 6 600-32-3C-5.5 32 600 12" 15.875" 2600 80,000 6 650-36-3C-5.5 LCL 36 36 650 12" 15.875" 2900 80,000 6 70-2-1C-5.5X 2 70 14" 17.875" 170 80,000 4 100-3-1C-5.5X 3 100 14" 17.875" 250 80,000 4 130-4-1C-5.5X 4 130 14" 17.875" 340 80,000 4 150-5-1C-5.5X 5 150 14" 17.875" 390 80,000 4 170-6-1C-5.5X 6 170 14" 17.875" 500 80,000 4 200-9-1C-5.5X 9 200 14" 17.875" 760 80,000 4 230-12-1C-5.5X 12 230 14" 17.875" 1000 80,000 4 390-18-2C-5.5X 18 390 14" 17.875" 1500 80,000 5 450-24-2C-5.5X 24 450 14" 17.875" 1950 80,000 5 550-30-2C-5.5X 30 550 14 17.875 2400 80,000 5 ated 8.25 KV @ 40 Degrees C Min. Interrupting ating MS Amps Max Interrupting ating MS (Asym) 70-2-1C-8.25 2 70 12" 15.875" 190 80,000 4 100-3-1C-8.25 3 100 12" 15.875" 225 80,000 4 130-4-1C-8.25 4 130 12" 15.875" 330 80,000 4 150-5-1C-8.25 5 150 12" 15.875" 440 80,000 4 170-6-1C-8.25 6 170 12" 15.875" 500 80,000 4 200-9-1C-8.25 9 200 12" 15.875" 740 80,000 4 230-12-1C-8.25 12 230 12" 15.875" 955 80,000 4 390-18-2C-8.25 18 390 12" 15.875" 1440 80,000 5 450-24-2C-8.25 24 450 12" 15.875" 1910 80,000 5 Add w suffix to part number for hookeye attachment. 66 w w w. l i t t e l f u s e. c o m 2005 Littelfuse POW-GAD Products

ated Littelfuse POW-GAD medium voltage fuses are available in several bolt-in mounting configurations. Contact factory for custom configurations. B BI IB Bolt mount Bolt-In mount Inverted-Bolt mount efer to illustrations for mounting dimensions. (2).34" X.660 Slots 1.38" Apart 3" Dia. 3" Dia. (2).34" Holes 1.38" Apart 7 8 9 10 Bolt Mount B Inverted-Bolt IB ated 2.75 KV Bolt Mount B 2.75 KV Inverted Bolt IB @ Degrees C Min. Interrupting Max Interrupting ating MS Amps ating MS (Asym) 70-2-1B-2.75 2 70 4.6" 13" 170 80,000 7 00-3-1B-2.75 3 100 4.6" 13" 250 80,000 7 30-4-1B-2.75 4 130 4.6" 13" 240 80,000 7 150-5-1B-2.75 5 150 4.6" 13" 390 80,000 7 170-6-1B-2.75 6 170 4.6" 13" 500 80,000 7 200-9-1B-2.75 9 200 4.6" 13" 760 80,000 7 230-12-1B-2.75 12 230 4.6" 13" 1000 80,000 7 390-18-2B-2.75 18 390 7.4" 13" 1500 80,000 8 450-24-2B-2.75 24 450 7.4" 13" 1950 80,000 8 70-2-1IB-2.75 2 70 13" 170 80,000 9 100-3-1IB-2.75 3 100 13" 250 80,000 9 130-4-1IB-2.75 4 130 13" 340 80,000 9 150-5-1IB-2.75 5 150 13" 390 80,000 9 170-6-1IB-2.75 6 170 13" 500 80,000 9 200-9-1IB-2.75 9 200 13" 760 80,000 9 230-12-1IB-2.75 12 230 13" 1000 80,000 9 390-18-2IB-2.75 18 390 13" 1500 80,000 10 450-24-2IB-2.75 24 450 13" 1950 80,000 10 2005 Littelfuse POW-GAD Products w w w. l i t t e l f u s e. c o m 67

ated.44" X.91" Slots (1.53" c.t.c.) 3"Dia. Bolt-In Mount BI ated Bolt In Mount BI Bolt Mount B Inverted Bolt IB 8.25 KV Bolt-In Mount BI Front View @ 40 C. Min. Interrupting Max Interrupting ating MS Amps ating MS (Asym) 70-2-1BI-5.5 2 70 3.6 18" 170 80,000 11 100-3-1BI-5.5 3 100 3.6 18" 250 80,000 11 130-4-1BI-5.5 4 130 3.6 18" 340 80,000 11 150-5-1BI-5.5 5 150 3.6 18" 390 80,000 11 170-6-1BI-5.5 6 170 3.6 18" 500 80,000 11 200-9-1BI-5.5 9 200 3.6 18" 760 80,000 11 230-12-1BI-5.5 12 230 3.6 18" 1000 80,000 11 390-18-2BI-5.5 18 390 7.6 18" 1500 80,000 12 450-24-2BI-5.5 24 450 7.6 18" 1950 80,000 12 480-26-2BI-5.5 26 480 7.6 18" 2200 80,000 12 550-30-2BI-5.5 30 550 7.6 18" 2400 80,000 12 600-32-2BI-5.5 32 600 7.6 18" 2650 80,000 12 650-36-2BI-5.5 36 650 7.6 18" 2900 80,000 12 550-30-3BI-5.5 30 550 18" 80,000 13 600-32-3BI-5.5 32 600 18" 80,000 13 650-36-3BI-5.5 36 650 18" 80,000 13 700-38-3BI-5.5 38 700 18" 80,000 13 70-2-1B-5.5 2 70 4.6 18" 170 80,000 7 100-3-1B-5.5 3 100 4.6 18" 250 80,000 7 130-4-1B-5.5 4 130 4.6 18" 340 80,000 7 150-5-1B-5.5 5 150 4.6 18" 390 80,000 7 170-6-1B-5.5 6 170 4.6 18" 500 80,000 7 200-9-1B-5.5 9 200 4.6 18" 760 80,000 7 230-12-1B-5.5 12 230 4.6 18" 1000 80,000 7 390-18-2B-5.5 18 390 7.4 18" 1500 80,000 8 450-24-2B-5.5 24 450 7.4 18" 1950 80,000 8 550-30-2B-5.5 30 550 8.4 18" 2400 80,000 8 600-32-2B-5.5 32 600 8.4 18" 2650 80,000 8 650-36-2B-5.5 36 650 8.4 18" 2900 80,000 8 70-2-1IB-5.5 2 70 18" 170 80,000 9 100-3-1IB-5.5 3 100 18" 250 80,000 9 130-4-1IB-5.5 4 130 18" 340 80,000 9 150-5-1IB-5.5 5 150 18" 390 80,000 9 170-6-1IB-5.5 6 170 18" 500 80,000 9 200-9-1IB-5.5 9 200 18" 760 80,000 9 230-12-1IB-5.5 12 230 18" 1000 80,000 9 390-18-2IB-5.5 18 390 18" 1500 80,000 10 450-24-2IB-5.5 24 450 18" 1950 80,000 10 550-30-2IB-5.5 30 550 18" 2400 80,000 10 600-32-2IB-5.5 32 600 18" 2650 80,000 10 650-36-2IB-5.5 36 650 18" 2900 80,000 10 70-2-1BI-8.25 2 70 3.6 18" 190 80,000 11 100-3-1BI-8.25 3 100 3.6 18" 225 80,000 11 130-4-1BI-8.25 4 130 3.6 18" 330 80,000 11 150-5-1BI-8.25 5 150 3.6 18" 400 80,000 11 170-6-1BI-8.25 6 170 3.6 18" 500 80,000 11 200-9-1BI-8.25 9 200 3.6 18" 740 80,000 11 230-12-1BI-8.25 12 230 3.6 18" 955 80,000 11 390-18-2BI-8.25 18 390 7.6 18" 1440 80,000 12 450-24-2BI-8.25 24 450 7.6 18" 1910 80,000 12 11 12 13 68 w w w. l i t t e l f u s e. c o m 2005 Littelfuse POW-GAD Products

Live Parts Live parts are available for mounting E,, and PT single, double, and triple barrel fuses. Mounting clips are available for ferrule type and clip lock style fuses. All clips are sold in pairs. Contact factory for additional live parts. Part : 700-156* System : 0700156.Z For use with 1-9 / 16" to 1-5 /8 (1.625 ) diameter PT fuses. Part : 700-300* System : 0700300.Z For use with 3" diameter fuses. 2.00 3.74 2.85 Part : 700-500* System : 0700500.Z For use with all 13 / 16" (.8125 ) diameter PT fuses..08 Part : 700-530* System : 0700530.Z For use with all 3" diameter fuses..31.78.71.30.08.038" HOLES 1.15.05 1.50 3.08 4.50 4.16.78.63 Part : 700-520-CL* System : 0700520.ZXCL Clip Lock Design (For CL-14) Mounting Details for Clip Lock 3.63 TIPLE BAEL 3.63 DOUBLE BAEL Bottom Lever In Closed Position * One Pair. Dimensions for reference only. Blown Fuse 2.00 4.9 TOP VIEW 4.85 3.75 2.00 Top Lever in Open Position SINGLE BAEL 1.00 A 2.00 1.75.56 Dia. (2) Holes For Mounting Cable/Bus.44 DIA. (2) HOLES 2005 Littelfuse POW-GAD Products w w w. l i t t e l f u s e. c o m 75