NYCA LOLE Violations (Methods D and E )

Similar documents
TRANSMISSION PLANNING CRITERIA

Falcon-Midway 115 kv Line Uprate Project Report

ECE 740. Optimal Power Flow

Final Draft Report. Assessment Summary. Hydro One Networks Inc. Longlac TS: Refurbish 115/44 kv, 25/33/ General Description

Feasibility Study Report

System Impact Study Report

Feasibility Study Report

Emerald Reactive Support Alternative Solution Expressions of interest

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

Alternator as a voltage Generating source and its response to the leading power factor loads

Georgia Transmission Corporation Georgia Systems Operations Corporation

Ancillary Services. Horace Horton Senior Market Trainer, Market Training, NYISO. New York Market Orientation Course (NYMOC)

The Long-Range Transmission Plan

Power Consump-on Management and Control for Peak Load Reduc-on in Smart Grids Using UPFC

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

Introduction to PowerWorld Tutorial Created by the University of Illinois at Urbana-Champaign TCIPG PMU Research Group 1

Interconnection Feasibility Study Report Request # GI Draft Report 600 MW Wind Generating Facility Missile Site 230 kv Substation, Colorado

100 MW Wind Generation Project

DETOUR GOLD CORPORATION SYSTEM IMPACT ASSESSMENT FOR DETOUR LAKE PROJECT

Reactive Power Compensation for Solar Power Plants. Andy Leon IEEE PES Chicago Chapter December 12 th, 2018

Concepts And Application Of Flexible Alternating Current Transmission System (FACTS) In Electric Power Network

ATTACHMENT Y STUDY REPORT

Local Transmission Plan. October 11, 2013 Revised August 25, 2014

New 115 kv Disconnect Switches at Bloomsburg MTS

Power Systems Fundamentals

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

Interconnection System Impact Study Report Request # GI

ABB POWER SYSTEMS CONSULTING

DISTRIBUTED GENERATION FROM SMALL HYDRO PLANTS. A CASE STUDY OF THE IMPACTS ON THE POWER DISTRIBUTION NETWORK.

Updated Transmission Expansion Plan for the Puget Sound Area to Support Winter South-to-North Transfers

THE NECESSITY OF THE 500 KV SYSTEM IN NWE S TRANSMISSION SYSTEM TO MAINTAIN RELIABLE SERVICE TO MONTANA CUSTOMERS

Islanding of 24-bus IEEE Reliability Test System

PJM Generator Interconnection R81 Emilie (Fords Mill) MW Impact Study Re-Study

IJRASET 2013: All Rights are Reserved

15 Nelson-Marlborough Regional Plan

AMERICAN ELECTRIC POWER 2017 FILING FERC FORM 715 ANNUAL TRANSMISSION PLANNING AND EVALUATION REPORT PART 4 TRANSMISSION PLANNING RELIABILITY CRITERIA

EXCEPTIONS TO NYSRC RELIABILITY RULES

TRANSMISSION LOSS MINIMIZATION USING ADVANCED UNIFIED POWER FLOW CONTROLLER (UPFC)

Overview of Flexible AC Transmission Systems

Southern Company Interconnection Process. Dexter Lewis Research Engineer Research and Technology Management

Introduction to PowerWorld Simulator: Interface and Common Tools

TECHNICAL TERMS AND ABBREVIATIONS

Targeted Application of STATCOM Technology in the Distribution Zone

The Status of Energy Storage Renewable Energy Depends on It. Pedro C. Elizondo Flex Energy Orlando, FL July 21, 2016

Generation Interconnection Feasibility Study For XXXXXXXXXXXXXXXXXXXXXX MW generator at new Western Refinary Substation

EXCEPTIONS TO RELIABILITY RULES Revision 11 February 9, 2018

EXCEPTIONS TO RELIABILITY RULES REVISION 4 MAY 8, 2015

DUKE ENERGY PROGRESS TRANSMISSION SYSTEM PLANNING SUMMARY

Interconnection Feasibility Study Report GIP-226-FEAS-R3

EL PASO ELECTRIC COMPANY (EPE) FACILITIES STUDY FOR PROPOSED HVDC TERMINAL INTERCONNECTION AT NEW ARTESIA 345 KV BUS

kvah Billing - Frequently Asked Questions (FAQs)

SIEMENS POWER SYSTEM SIMULATION FOR ENGINEERS (PSS/E) LAB1 INTRODUCTION TO SAVE CASE (*.sav) FILES

Gateway South Transmission Project

15 Nelson-Marlborough Regional Plan

Enhancing the Voltage Profile in Distribution System with 40GW of Solar PV rooftop in Indian grid by 2022: A review

Electrical Power Electric power electrical electric power Electric power electric electric

2015 Preliminary Weather Normalized MW and 2016 ICAP Forecast (V3)

Power System Economics and Market Modeling

Electrical Transmission System Analysis EE 456 project. Team Members Abdulaziz Almarzouqi Hamzah Abeer

Islanding of 24-bus IEEE Reliability Test System

Facilities Study for Alberta to US Available Transfer Capability

White Paper. Application of Resistive/Reactive Load Banks for kva Testing

Ancillary Services. Horace Horton. Market Overview Course. Senior Market Trainer, Market Training, NYISO. March 8, Rensselaer, NY 12144

Flexible Distributed Generation. FDG-F Burwell (EPN) May 2017

Relative Power Factor Correction costs

Rogers Road to Clubhouse 230kV New Transmission Line April 1, 2016

ORDINANCE NO. -'- THE PEOPLE OF THE CITY OF LOS ANGELES DO ORDAIN AS FOLLOWS:

APPENDIX E: Project Need and Description

APPENDIX E: Project Need and Description

EE 456 Design Project

CHAPTER I INTRODUCTION

2018 Final ICAP Forecast

Interconnection Feasibility Study Report GIP-IR373-FEAS-R1

Transmission Planning using Production Cost Simulation & Power Flow Analysis

NETSSWorks Software: An Extended AC Optimal Power Flow (AC XOPF) For Managing Available System Resources

Feasibility Study Report

Case 13-M Edic to New Scotland 345 kv Transmission Line and Hurley Avenue PARs Project (ED-NS/HA) Article VII Filing ED-NS/HA

Supplemental Report on the NCTPC Collaborative Transmission Plan

The Power Potential Project A guide to participating

Appendix D Black Hills Project Summary

Transmission Coordination and Planning Committee 2016 Q4 Stakeholder Meeting

Interconnection System Impact Study Final Report February 19, 2018

SSF Section Location of Change SSF Issue Change(s) Comments Chapter Part B All Multiple Formatting, spelling and minor Changes applied -

Generator Interconnection Facilities Study For SCE&G Two Combustion Turbine Generators at Hagood

El PASO ELECTRIC COMPANY 2014 BULK ELECTRIC SYSTEM TRANSMISSION ASSESSMENT FOR YEARS

Connection Engineering Study Report for AUC Application: AESO Project # 1674

CUSTOMER/ TWIN ARROWS PROJECT

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Evaluating Losses in Electrical Equipment Focus on Transmission Utilities. CNY Engineering Expo 2016 Syracuse, New York Arthur C. Depoian P.E.

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 Lihue, Kauai, Hawaii Original Sheet 5 RULE NO. 2 CHARACTER OF SERVICE

Group 3: Pricing from 1 April 2018 and load management

Power Potential Guide to Participating : A technical 0 guide to the services for synchronous and non-synchronous DER participants 04/10/2017

Q217 Generator Interconnection Project

2017 Interim Area Transmission Review of the New York State Bulk Power Transmission System

2019 Preliminary ICAP Forecast

Stability Study for the Mt. Olive Hartburg 500 kv Line

Generator Efficiency Optimization at Remote Sites

DRAFT. Guidelines on Power quality & safety issues in usage of roof-top solar pv system CENTRAL ELECTRICITY AUTHORITY

Large General Service Time-of-Use Storage Program

Ancillary Services & Essential Reliability Services

Transcription:

Proposals for Cost Allocation of Regulated Reliability Solutions Associated with NYCA LOLE Violations (Methods D and E ) Presented by Jerry Ancona National Grid For Discussion by NYISO Electric System Planning Working Group (ESPWG) Albany, NY January 17, 2006 Rev.: 17-Jan-2006 (Supersedes 9-Jan-2006 Handout)

Power Systems 101 2

Power Systems 101 Real and Reactive Power Power Factor Generation Load Losses Thermal Limits Voltage Drop Bus Voltage Limits Capacitors 3

Real and Reactive Power Heating loads and incandescent lighting loads consume only Real Power (MW) Motors and transformers (and appliances and equipment including motors and transformers) consume both Real Power (MW) and Reactive Power (MVAr) The composite of both Real and Reactive Power is Apparent Power (MVA) MVA = (MW) + (MVAr) 2 2 4

Power Factor Power Factor is the ratio of Real Power to Apparent Power PF =(MW)/(MVA) Unity Power Factor PF = 1.0 MW = MVA Thus MVAr = 0 Leading versus Lagging Power Factors Leading Lagging Load Producing VArs Consuming VArs Generator Absorbing VArs Producing VArs 5

Power Factor Example Compute the Apparent Power and Power Factor associated with a Load of 100 MW and 33 MVAr Apparent Power MVA MVA = (100) = 105.3 Power Factor PF PF = = Cos T 95.0% = 2 + (33) (100)/(105.3) 2 C T 105.3 MVA 100 MW 33 MVAr 6

Generation Gen X MW MVAr Generator produces both Real (MW) and Reactive (MVAr) Power Generator may absorb Reactive Power instead of producing it if needed to reduce high voltage problems 7

Loads Load Y Load consumes both Real (MW) and Reactive (MVAr) Power MW MVAr Real and Reactive Power flow on transmission facilities from generators to serve loads results in losses and voltage drop on those transmission facilities 8

Losses on Transmission Facilities Gen X Load Y Line A MW MVAr Transmission Facilities consume both Real (MW) and Reactive (MVAr) Power in the form of losses as a result of power flowing from Generators to Loads Real and Reactive Power Line losses vary exponentially with line flow MW Line Losses result from both Real and Reactive Power flowing across Line Resistance MVAr Line Losses result from both Real and Reactive Power flowing across Line Reactance Generator serves Real and Reactive Load and Losses 9

Transmission Thermal Rating Thermal ratings are invoked on transmission facilities to prevent Equipment damage due to over-heating Excessive sag in overhead lines Thermal Rating Categories Summer vs. Winter Normal (Continuous) LTE (Long Term Emergency = 4 hrs per day) STE (Short Term Emergency = 15 minutes) 10

Transmission Thermal Overloads Thermal facilities can be overloaded by both Real (MW) and Reactive (MVAr) Power flow Strictly speaking, Thermal Ratings are based upon Current Ratings (Amperes) For simplicity Current ratings are converted to MVA ratings using a presumed system voltage Then MVA ratings are converted to MW ratings using a presumed Power Factor MW Ratings may be overly optimistic if either actual system voltages or power factors are lower than the presumed values 11

Bus Voltage Limits Bus X Bus Y Bus is a termination or connection point for generators, loads and transmission facilities Each Bus has high and low voltage limits (as a % of the nominal voltage) for both pre-contingency and postcontingency conditions. For example Voltage Limits High Low Pre 105% 100% Post 105% 95% Note: Adhering to high voltage limit at one Bus may impinge on ability to adhere to low voltage limit at another Bus 12

Voltage Drop on Transmission Facilities Gen X Bus X Bus X Voltage Drop: 3% Load Y Voltage @105% MW MVAr Voltage @102% Voltage drop occurs from Generators to Loads (Sources to Sinks) due to Real and Reactive Power flowing through the Resistance and Reactance of Transmission Facilities Voltage Drop varies proportionately with both Real (MW) and Reactive (MVAr) Power flow 13

Load Power Factors Typically Load Factors during peak times are in the 90% to 95% range. For example Load Power Factor (PF) Real Load (MW) Reactive Power (MVAr) Total Apparent Power (MVA) 90% 1,000 484.3 1,111.1 95% 1,000 328.7 1,052.6 14

Capacitors CCapacitor MVAr Capacitors produce reactive power (MVAr) thereby compensating for reactive power consumed by loads When installed locally, capacitors reduce reactive power flows over transmission facilities from more remote sources which Reduces line losses Reduces voltage drop In the extreme: can produce voltage rise Underground cable and lightly loaded overhead transmission lines act as capacitors 15

Contributors to Reliability Violations Gen X Bus X Bus Y Line A Load Y Inability to serve Load Y (i.e., having a detrimental impact on LOLE) can be contributed to by Real and Reactive Power flowing to serve Load Y exceeding available capability of Generator X Real and Reactive Power flowing to serve Load Y exceeding thermal rating of Line A Real and Reactive Power flowing to serve Load Y results in excessive voltage drop from Bus X to Bus Y Both Real and Reactive Power flowing to serve loads contribute to reliability violations 16

Solutions to Reliability Violations Depending upon circumstances, solutions to the inability to serve Load Y could include Increase capability of transmission system to Increase X to Y thermal rating Improve voltage at Bus Y Bus Y Add Generator at Bus Y Gen X Bus X Line A Load Y Reduce Real and/or Reactive Load at Load Y through DSM, etc. Increase available capability of Generator X Other? Compensate reactive power consumption at Bus Y with capacitor, etc. to Improve voltage at Bus Y Reduce loading on Line A 17

Observations Gen MW MVAr Load Reliability Violations are contributed to by both Real and Reactive Power consumption (not necessarily on an equal impact basis) A Reliability Violation may be alleviated by Reducing Real Power (MW) consumption Reducing Reactive Power (MVAr) consumption Increasing Real Power (MW) Production and/or Delivery Increasing Reactive Power (MVAr) Production and/or Delivery 18

Cost Allocation 19

Cost Allocation Principles 1. Load Decrements Can Determine Contribution Decrementing loads at various locations is a legitimate way to ascertain which and to what degree individual loads contribute to a reliability violation. 2. Loads Should be Decremented in MVA at Prevailing PF Loads should be decremented simultaneously as both Real (MW) and Reactive (MVAr) Power using the applicable peak load Power Factors. 3. Decrementing Only Real or Reactive Loads May Produce Misleading Results Decrementing only one load component (i.e., either Real or Reactive loads, but not both simultaneously) to determine contribution to a reliability violation invokes an artificial and disproportional importance to the impact of that one component when in fact both Real and Reactive Power components contribute to the reliability violation. 20

Principles (cont.) 4. Non-Contributors to a Violation Should Not be Allocated Costs A decremented load that does not help alleviate a reliability violation should not be assigned an allocation of costs for a solution because this shows it does not contribute to the violation. 5. All Loads Contributing to a Violation Should Be Allocated Costs All loads that contribute to a reliability violation should be allocated a portion of the cost of the solution even if one load can be decremented such that it can fully eliminate the violation, it should not be allocated 100% of the cost of a solution unless no other decremented load can help alleviate the violation. 6. The Cost Allocation Method Should Not be Dependent Upon the Specific Solution Various types of regulated solutions that meet a specific need (either fully or partially) should be cost allocated in the same way. 21

Principles (cont.) 7. Loads that Contribute Proportionally More to a Violation (per MVA) Should Be Allocated Proportionately More Cost A decremented load that is twice as effective (per MVA of load drop) as another decremented load in alleviating a violation should be allocated costs for the solution at a rate twice as high. 8. A Larger Load that Contributes to a Violation Equally as a Smaller Load (per MVA) Should be Allocated Proportionately More Cost If two decremented loads are equally effective (per MVA of load drop) in alleviating a violation, and one load is twice as large as the other, the larger load should be cost allocated twice as much. 9. Cost Allocation Methods Should Be Similar for Various Violations To the extend possible, cost allocation methods should be the same regardless of the type of violation that occurs. 22

Cost Allocation Example Diagram Gen X 610 MW 268 MVAr UCAP = 700 MW Bus X Load X 100 MW 33 MVAr 510 MW 235 MVAr Line X-Y Bus Y V @ 105% V @ 98% Thermal limit = 600 MW Load Y 200 MW 85 MVAr 310 MW 150 MVAr Line Y-Z Thermal limit = 300 MW Bus Z V @ 94% Load Z 400 MW Gen Z 90 MW 44 MVAr UCAP = 90 MW - Low Voltage Limits for all Buses = 95% (or higher) 194 MVAr - Flows shown are those required to meet LOLE criteria of 0.1 or less - Required flows result in Thermal Overload of Line Y-Z - Required flows result in More Restrictive Low Voltage Violation at Bus Z - Line Y-Z needs to be limited to 270 MW to maintain 95% voltage at Bus Z - - Resulting LOLE (honoring transmission and UCAP constraints) = 0.3 23

Methods D and E Method D Decrement MVA loads individually in each sub-zone and then on a uniform basis for all sub-zones whose load decrement can improve LOLE Method E Decrement MVAr loads individually in each sub-zone and then on a uniform basis for all sub-zones whose load decrement can alleviate Voltage Limits Then decrement MW loads individually in each sub-zone and then on a uniform basis for all sub-zones whose load decrement can improve LOLE Both Methods intended to Accommodate the 9 aforementioned Cost Allocation Principles Apply to NYCA LOLE violations (whether partially exacerbated by inter-zonal transfer limits or not) 24

Method D Cost Allocation Summary Decrement load in each sub-zone (uniformly across that sub-zone) on an MVA basis at that sub-zone s prevailing power factor Determine sub-zone s relative contribution based upon the degree to which its decremented load alleviates a violation (taking into account that load decrements may impact transfer limits) Allocate cost to each contributing sub-zone proportionally to the sub-zone s relative load size and associated impact on the violation (similar to using a Generator Shift Factor) 25

Method D Example - Cost Allocation Computation Method D LOLE Violation Cost Allocation Example Loads at Buses X, Y and Z pay on a proportional basis based upon their individual Real and Reactive Power (at prevailing Power Factors) impacts on LOLE Representative Values for Illustrative Purposes - Not Necessarily Actual 26 Bus X Bus Y Bus Z Total Area Coincident Peak Apparent Power Load (MVA) 105 217 445 767 Coincident Peak Real Load (MW) 100 200 400 700 Coincident Peak Reactive Load (MVAr) 33 85 194 312 As Found LOLE 0.30 As Found Line Y-Z Limits (MW) 270 MW Voltage; 300 MW Thermal % Load Reduction in MVA Needed Alone No Impact 32.0% 8.0% -- MVA Load Reduction Needed on One Bus No Impact 70 36 -- MW Load Reduction Needed on One Bus No Impact 64 32 -- MVAr Load Reduction Needed on One Bus No Impact 27 16 -- Resulting Line Y-Z Voltage Limit (MW) after Single Bus (Sub-Area) Load Reduction No Impact 300 278 -- MVA Load Reduction Equivalent to the Impact of 1 MVA Reduction at Bus Z No Impact 1.96 1.00 -- % Load Reduction Needed if Shared No Impact 6.40% 6.40% -- MVA Load Reduction Needed if Shared No Impact 14 28 42 Resulting Line Y-Z Limits (MW) after Equally Shared MVA Load Reductions 310 MW Voltage; 300 MW Thermal MVA Load Reduction on an Equivalent Bus Z Load Reduction Impact Basis - 7 28 36 Cost Allocation by Bus (Sub-Area) for a Regulated Solution 0.0% 20.0% 80.0% 100.0% "% Load Reduction Needed Alone" is uniform load decrease solely at Bus X, Y or Z (at their own Power Factors) that is sufficient to reduce NYCA LOLE to less than 0.1. Based on above results, in terms of decreasing LOLE, a 1.96 MVA reduction at Bus Y equals a 1.0 MVA reduction at Bus Z (36 MVA needs to be reduced at Buz Z, or an equivalent amount at both Bus Y and Z) Total % Load Reduction needed if shared unifirmly is determined by solving for R where: (217 x R/1.96) + (445 x R) = 36; thus R = (36) / ((217 / 1.96) + 445) = 6.40%

Method D Example - Results Buses are proxies for Sub-zones Decrementing MVA Load at Bus X has no impact on improving LOLE therefore Bus X does not contribute to violation and is allocated no cost Each of the following load decrements improves LOLE to below 0.1 (in the process, they improve voltages at both Bus Y and Bus Z, and raise the X-Y voltage transfer limit): 70 MVA at Bus Y (32.0% of its load) 36 MVA at Bus Z (8.0% of its load) 14 MVA at Bus Y and 28 MVA at Bus Z (6.40% of each) Bus Z is allocated 80.0% of the cost of the solution versus 20.0% for Bus Y because it contributes proportionately more to the violation in two ways: A 1.0 MVA load drop on Bus Z is equivalent to a 1.96 MVA load drop on Bus Y (i.e., Bus Z load drops are more effective in alleviating the violation consequently, Bus Z load contributes proportionately more to the violation) Bus Z load is more than twice the level (205%) of Bus Y load, and therefore also contributes proportionately more to the violation 27

Method E Cost Allocation Summary If a Voltage Limit contributes to an LOLE > 0.1, decrement load in each sub-zone (uniformly across that sub-zone) on an MVAr basis Determine sub-zone s relative contribution based upon the degree to which its decremented load alleviates a voltage violation (towards making a Thermal Limit the more restrictive) Allocate cost to each contributing sub-zone proportionally to the sub-zone s relative load size and associated impact on the voltage violation (similar to using a Generator Shift Factor) If LOLE is still > 0.1 after Voltage Limit is eliminated, decrement loads in each sub-zone on a MW basis in a method parallel to above 28

Method E Example - Cost Allocation Computation Method E - Part 1 LOLE Violation Cost Allocation Example Loads at Buses X, Y and Z pay on a proportional basis based upon their individual Reactive Power impacts on LOLE Representative Values for Illustrative Purposes - Not Necessarily Actual Bus X Bus Y Bus Z Total Area Coincident Peak Apparent Power Load (MVA) 105 217 445 767 Coincident Peak Real Load (MW) 100 200 400 700 Coincident Peak Reactive Load (MVAr) 33 85 194 312 As Found LOLE As Found Volatge at Buz Z 0.30 94.1% As Found Line Y-Z Limits (MW) 270 MW Voltage; 300 MW Thermal % Load Reduction in MVAr on One Bus 100.0% 100.0% 20.0% -- MVAr Load Reduction on One Bus 33 85 39 -- Resulting Bus Z Voltage Unchanged 94.5% 94.5% -- MVAr Load Reduction Equivalent to the Impact of 1 MVAr Reduction at Bus Z No Impact 2.19 1.00 -- % Load Reduction in MVAr to Attain 95% Not No Impact Voltage at Bus Z Attainable 70.0% MVAr Load Reduction to Attain 95% at Bus Z No Impact " " " 136 -- % Load Redution in MVAr if Shared No Impact 58.3% 58.3% MVAr Load Reduction Needed if Shared No Impact 50 113 163 Resulting Line Y-Z Limits (MW) after Equally Shared MVAr Load Reductions 310 MW Voltage; 300 MW Thermal MVAr Load Reduction on an Equivalent Bus Z Load Reduction Impact Basis - 23 113 136 Cost Allocation by Bus (Sub-Area) for a Regulated Solution 0.0% 16.7% 83.3% 100.0% Resulting LOLE w New Limits 0.08 "% Load Reduction Needed Alone" is uniform load decrease solely at Bus X, Y or Z (at their own Power Factors) Based on above results, in terms of improving voltage at Bus Z, a 2.19 MVAr reduction at Bus Y equals a 1.0 MVAr reduction at Bus Z Total % MVAr Load Reduction needed if shared unifirmly is determined by solving for R where: (85 x R/2.19) + (194 x R) = 136; thus R = (136) / ((85 / 2.19) + 194) = 58.3% 29

Method E Example - Results Buses are proxies for Sub-zones Decrementing MVAr Load at Bus X has no impact on improving Bus Z Voltage therefore Bus X does not contribute to violation and is allocated no cost Decrementing 100% of MVAr Load at Bus Y improves voltage at Bus Z from 94.1% to 94.5%. A 20% MVAr Load decrement at Bus Z has the same impact. Decrementing 70% of MVAr Load at Bus Z improves voltage at Bus Z to 95.0% Decrementing 58.3% of MVAr Load at both Bus Y and Bus Z also improves voltage at Bus Z to 95.0% Eliminating the Line Y-Z Voltage Limit improves the LOLE to less than 0.1 Bus Z is allocated 83.3% of the cost of the solution versus 16.7% for Bus Y because it contributes proportionately more to the violation in two ways: A 1.0 MVAr load drop on Bus Z is equivalent to a 2.19 MVAr load drop on Bus Y (i.e., Bus Z Reactive Power load drops are more effective in alleviating the violation consequently, Bus Z load contributes proportionately more to the violation) Bus Z MVAr load is more than twice the level of Bus Y MVAr load, and therefore also contributes proportionately more to the violation 30