Model 20 DPS.2005 Doc: J2-20DPS2005/01 Nov 2006

Similar documents
J3C-H Nm Smart Electric Valve Actuator

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

Model J Doc: J3/3740/01 Jan 2008

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ANSI/ASME 150 lb 2 to 6 inch Pipe

J3C-L Nm Smart Electric Valve Actuator Failsafe Function Type: J3C Model: L140-BSR

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

J3C-H20 25Nm Smart Electric Valve Actuator

Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview. 11 or 14mm drive output (Option)

SERIES EBVF / TEBVF MULTI-VOLTAGE ACTUATOR WITH FAIL-SAFE AND 4-20mA DIGITAL POSITIONER OPTIONS

Electric Flanged PN16 Cast Iron Ball Valve

Electric Actuated Ball Valves 3-piece Stainless Steel, Full Port 1/4 to 3 NPT

Electric Actuated Ball Valves 150# Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe

ELECTRIC ACTUATOR S20 - S35 - S55 - S85

Electric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe with EPS Positioner

Electric Actuated 3-Way Ball Valves L-Port, PVC Body, Teflon/EPDM Seals 1/2 to 2 inch Pipe

Multi-colour LED Status Light - using it as a diagnostic tool:

ECON ELECTRIC ACTUATOR Fig ELA60 Ex

Quarter Master Series 94 Actuator

Electrically Actuated Ball Valves

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Electric FIP Type TKD ABS 3 Way Ball Valve

Installation, Operation and Maintenance Manual

Technical Specification. RCS Electric Actuators with a ProfiBus Field Control and Communication Module

Quarter Master Chief Series 92 Actuator

Electric Actuated 3-Way Ball Valves T-Port Diverter, Stainless Steel, Full Port 1/4 to 2 NPT

ECP3, ECP5, ECP8 Series Actuators

Actuated Valves. Product Information

EL5600 Series Electric Actuators for DN15 to DN100 Valves

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

E J3-Series. Electric quarterturn / partturn actuators. ASC Armaturen GmbH - D Popelau

Electric Actuated Butterfly Valves Ductile Iron Wafer Body ASME 150# 2 to 6 Pipe

Motorized Butterfly Valve

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

Minimum 18 in-lb Torque

Motorized Butterfly Valve Actuated Wafer type butterfly valves

Motorized Butterfly Valve

KEYSTONE F777/778 ELECTRIC ACTUATORS

Motorized Butterfly Valve

Electric Actuated Butterfly Valves Ductile Iron Lug Body ASME 150# 2 to 6 Pipe

Electric quarter turn actuator CENTORK 480 Series

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

Installation, Maintenance and Operation Manual

Electric Actuator Options & Accessories

Bray Series 70 Electric Actuator. Basic Product/Sales School

Surepowr Series 100 Installation Manual

Field IT Actuators & Positioners Rotary Actuators - Rated Torque 100 Nm (80 ft-lbs) PME 120-AI/AN. Rotary Actuators Rated Torque 100 NM (80 ft-lbs)

Compact electric actuators for 90 operation of 1/4 turn valves providing a range of torque outputs up to 1645 Nm.

Quarter turn actuators Index

USER S MANUAL. Installation, Operation, & Maintenance

Compact Electric Actuated 3-Way Ball Valves T-Port, 316 Stainless Steel, Full Port 1/4 to 3/4 NPT

Q Range Watertight Single-Phase Electric Quarter-turn Actuators for part-turn valves and dampers

P3 3-STOP POSITIONER IOM

V4(V7)-ABFW-EPN16 Actuated Wafer type butterfly valves

Gearbox Instruction Manual

RE Generation II Troubleshooting Guide Section I Preliminary Information and Evaluation

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Electric Actuator J3C ELECTRIC ACTUATOR. Actuators

Motorized CEPEX EXTREME Ball Valve

Electric Actuators Maximum in-lbs

HQ Series ¼ Turn Electric Actuator

Radius, LLC Electric quarter turn actuator EW series Installation, Maintenance and Operating Manual

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

Electric Actuators Maximum in-lbs

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

MAQ Series Electric Actuator

Minimum 27 in-lb torque

SAX Electronic Valve Actuator

NFB24, NFB24-S, NFX24, NFX24-S On/Off, Spring Return, 24 V

Series A Electric Linear Actuators

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

PNEUMATIC ACTUATORS. Linear acting

Series 10 Actuator. Installation, Operation and Maintenance Manual

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

MME/MOE Intelligent Electric Actuators About Ontrac

Versatile and Powerful

AE Installation Operation & Maintenance Instructions

HQ Series ¼ Turn Electric Actuator

Minimum 27 in-lb Torque

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

Installation and Operating Manual

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

Electric Actuator Instructions

SatchwellTM ALMS, ALXS, ALES SPRING RETURN LINEAR ACTUATORS. Satchwell FEATURES

Q Range electric direct-drive quarter turn valve actuators. Instruction manual

RCEL005 / RCEL

Gearbox Installation Manual

RP-4000 Reserve Power Control

Established leaders in Actuation Technology. ROM & RBM Range 1/4 turn direct drive electric actuators. Publication E611E issue 10/02

Mount directly to 1.05 jackshafts. AF230 US (p. 02) AF230-S US (p. 20) AF24-S US (p. 18)

ROMpak Series. Keeping the World Flowing. Installation Manual. Valve Actuators

Installation, Operating & Maintenance Instructions. Norbro J-Switch FM 00707

Sentry Battery Charger. Installation and Operations Manual Section 75

Electric Actuator EQ Series

Transcription:

Model 20 DPS.2005 Doc: J2-20DPS2005/01 J2-20 IP65 Modulating Electric Actuator Main Features: The maintenance free J2 electric actuator is very user friendly. It offers more standard features than any rivals in its class, and was first to the market with both multi-voltage capability with automatic voltage sensing, and an electronic torque limiter with auto-gearbox relaxing which frees the manual override when a valve is jammed. The manual override facility, with a safety power cut-out switch when operated, allows safe hand operation. Time saving external DIN plugs allow installations to be pre-wired and eliminates the need to remove the cover to connect the actuator, which helps to reduce installation costs. With a soft start system eliminating high motor start loads and a thermostatic anti-condensation heater that does not require a separate connection, the J2 offers low power consumption. The IP65 weatherproof plastic housing with stainless steel cover screws offers excellent corrosion resistance. Local visual position indication and remote volt free end of travel confirmation are provided as standard. The J2 is quick and easy to install: a) ISO:5211 multi-flange F03/F04 or F05 mounting with a 14mm female double square (star) drive. b) Factory set open and closed positions at 0 and 90 (or as specified on your order). c) External electrical connections and external wiring diagram- no need to remove the cover to connect. Note: Always read the supplied installation & operating instructions (IOM s) before use. Multi-voltage capable with auto-voltage sensing: J2-L20 12-48V AC/DC J2-H20 80-240V AC/DC Torque output:: 25Nm Break 20Nm Reseat Electronic torque limiter ~ protects against valve jams Anti-condensation heater Manual override All connections via external DIN plugs ~ no need to remove the cover to connect Volt free end of travel confirmation switches IP65 weatherproof housing J2 -Model 20 DPS ~ Digital Positioning System Digital Positioning System 2005 (DPS.2005) This version uses a factory fitted internal digital positioner to control the movement of the actuator relative to a control signal, either 4-20mA or 0-10VDC, and provides an output signal as standard. The DPS.2005 is a self calibrating and auto-adjusting unit. On first power-up, the positioner sets the span based on the motor open and closed positions. Should the actuator be over-rotated whilst in manual operation, when it is placed back in automatic function the positioner will automatically self adjust back to the original settings based on the motor open and closed positions. The DPS.2005 arrives at the desired position and stops, eliminating hunting. CE marked Traceable sequential serial numbering system Modulating function by our DPS self calibrating and autoadjusting digital positioning system with feedback. 4-20mA control with 4-20mA output or 0-10VDC control with 0-10VDC output.

Model 20 DPS Electric Actuator Specifications: J2-20 DPS Electric actuator (Modulating) Models Housing J2-H20-D4 80-240V AC (1ph) or DC 4-20mA J2-L20 -D4 12-48V AC (1ph) or DC 4-20mA J2-H20-D0 80-240V AC (1ph) or DC 0-10VDC J2-L20 -D0 12-48V AC (1ph) or DC 0-10VDC IP65 Anti-corrosive Polyamide Duty Rating 100% Mounting Electrical Connection Torque Output Temp Range Working Time (0-90 ) IS05211 & DIN3337 External via DIN plugs 25Nm Break, 20Nm Run & re-seat -20ºC to +70ºC 8 Secs ± 10%, no load Current 220VAC/ 110VAC 85 ma 20.9W / 180 ma 19.8W Current 24VAC/ 24VDC 1900 ma 45.8W / 900 ma 21.6W Weight 1.5 kg Dimensions: On/off, stays put on power failure: A: Multi-flange: F03/04/05 ISO5211 B: 14mm double square (star) 1 Manual override & local position indicator 2 Power supply DIN plug 3 Manual override selector lever 4 Volt free limit switch DIN plug 5 Control signal DIN plug Wiring: A.C Live Neutral POWER 1 2 3 E 2 Power & Volt free: 2 = CLOSE 3 = OPEN Items below dotted line: Customer to supply 3 CONTROL 1 + Input + Output - Input 1 2 3 E VOLT FREE Wiring Diagram (AC or DC): 2 wire Notes: DIN plugs supplied with actuator. Control signal plug rotated by 180. For DC Wiring: +ve Power DIN plug Pin 2 -ve Power DIN plug Pin 3 We reserve the right to amend specifications. Uncontrolled copy not subject to automatic updates.

Installation, Operation & Maintenance Instructions (IOM s) Model J2 DPS.2005 Doc: IOM.DPS.2005/02 FUNCTION The DPS.2005 is a self calibrating and auto-adjusting Digital Positioning System supplied as a factory fitted option to the J2 range of reversible electric actuators to produce modulating functionality. The self calibrating feature senses the motor stop positions (fully open and fully closed) and sets the span at these positions, and then calibrates the steps between open and closed for either 4-20mA or 0-10VDC control signals. Should the actuator be rotated by hand beyond these positions whilst being operated in MAN (manual operation mode) and then returned to AUTO (Automatic operation) whilst still outside the normal working quadrant as indicated by the open and closed logos moulded into the top of the actuator s cover, the DPS.2005 will auto adjust itself back into the normal working quadrant. Hunting has been eliminated in the DPS.2005 and as soon as the actuator arrives at the required position relative to the input signal, it stops. The DPS.2005 provides a feedback signal (in the same format as the input signal) as standard. INSTALLATION INSTRUCTIONS J2 actuators operate using live electricity and we strongly recommend that only qualified electricians/ electrical engineers be employed to make electrical connections as a matter of Health & Safety. They are quick and easy to connect without removing the cover, do not remove the cover without our authorisation or the warranty may be invalidated: Check that the voltage being applied matches the voltage shown on the actuator s identification label and connect the power supply, control signal and volt free end of travel confirmation switch cables to the DIN plug(s) as per the wiring diagram affixed to the side of the actuator. Ensure that polarity of the control signal cable is as per the wiring diagram. Removing any label will invalidate the warranty. Wiring is the same for AC or DC (2 wire). If in doubt, ASK BEFORE CONNECTING. Ensure that the rubber seal is refitted between the Din plug and base to maintain the IP65 seal, failure to fit the seals will invalidate the warranty. Do not over-tighten the plug securing screw. Do not connect a power supply voltage in excess of 48V to the low voltage (J2-L) series as irreparable damage will be caused and any warranty invalidated. If the volt free plug is not being used, blank off the cable entry to the DIN plug and leave the plug fitted to the actuator to maintain its IP65 weatherproof rating. Take care not to knock the DIN plugs as this may pull the DIN plug base away from the actuator which in turn will break the body seal and permit water to access the housing. Damage of this nature invalidates any warranty. All J2 actuators are supplied with volt free position confirmation switches (limit switches) that require a separate power supply to operate (rated 240V 5A) The suggested wiring as per the wiring diagram affixed to the side of the actuator shows the same voltage for the actuator being used as the power source for these switches this is a suggestion only and any standard control voltage can be used (eg: 24VDC). The volt free end of travel confirmation switches are set slightly ahead of the motor stop positions do not use the signal from these switches to cut the power to the motor. Whilst the J2 actuators can be fitted in any orientation we recommend installing the actuator vertically wherever possible. Be aware of applications where elevated temperatures could be present and allow for the possibility of heat rising in these cases use an extended mounting kit to help dissipate the heat, and mount the actuator horizontally. OPERATING INSTRUCTIONS Supply a continuous (not pulse) live signal to power the actuator. The in-built heater uses this mains supply and therefore the power supply voltage should remain on at all times. On receipt of a control input signal the actuator will move to the position relative to the input signal eg: using a 4-20mA signal, 4mA input signal closes the actuator, a 12mA signal sets the actuator at 45 and a 20mA signal opens the actuator. Each subsequent change of input signal will cause a corresponding change to the actuator position. An output signal in the same form as the input signal is supplied as standard. The rest positions are as per the moulded open and closed logos (see below), indicated by a local visual position indicator. NEVER move the set position of this indicator or a false position will be indicated. In the case of control signal failure, the actuator will move to the closed position. In the case of mains power failure, the actuator will stay in the position it saw at the moment of power interruption. Should the actuator need to be operated under these circumstances, use the manual override facility, but remember to reset the selector lever in the AUTO position when the movement is completed as selection of MAN cuts the power to the motor. All J2 actuators have an electronic torque limiter (ETL) which cuts the motor power if the applied torque exceeds the actuators rated output. To reset, cut the power, clear the cause of the excess torque (eg: valve blockage), turn the power back on and the limiter will reset allowing resumption of normal operation. Continued on page 2...

Installation, Operation & Maintenance Instructions (IOM s) Model J2 DPS.2005 Doc: IOM.DPS.2005/02 Page 2 MANUAL OVERRIDE All J2 actuators have a manual override facility, operated by a selector lever which disengages the motor drive when moved from AUTO (automatic operation) to MAN (manual operation). The gearbox contains planetary gears and it may be necessary to wiggle the selector lever whilst gently moving the manual override handle to ensure the gears disengage and re-engage. When resetting into AUTO a positive click will be felt when the gears have correctly re-engaged. A safety cut out switch, activated by the manual override selector lever, cuts the power to the motor when in the MAN position. When MAN is selected, the actuator will not operate electrically. NEVER remove the selector lever retaining screw as this will allow the operating mechanism to become free and will cause irreparable damage to the actuator s gearbox. Removing this screw will invalidate any warranty. When in AUTO mode, the manual override operating handle rotates on models 20 & 55 restricting this rotation may activate the ETL. In these circumstances, switch off the power, leave a few seconds and turn back on the ETL will automatically reset The open and closed logos: moulded into the top cover look like this: OPEN CLOSED MAINTENANCE J2 actuators are designed to be maintenance free, the gearbox is factory lubricated for life and there are no internal parts that require maintenance.

AC Wiring diagram - DPS.2005 Modulating Doc: J2WD.DPS.2005.AC/01

DC Wiring diagram - DPS.2005 Modulating Doc: J2WD.DPS.2005.DC/01