PowerSTAR PS-2024-D. Maximum Power Point Tracking Solar Regulator. w w w. r o c s o l i d. c o m. a u. Contents

Similar documents
User Manual Solar Charge Controller 3KW

KIT-STCS60D KIT-STCS100D Solar Suitcase 60W and 100W Owner s Manual

User Manual. Solar Charge Controller 3KW

D2020N. Negative Ground 20A Max. Charge 20A Max. Load. Advanced Solar Charge Controller. DINGO User Guide. Read this before installing. Ver 1.

Online Capacity Tester MK70 User and PC-Software Manual

Issue 2.0 December EPAS Midi User Manual EPAS35

PV Charge Controller SBC-7108 / 7112 / 7120

User s Manual CC-MPPT-HV-50

ML Maximum Power Point Tracking (MPPT) Series ML2420-ML2430-ML2440 Solar Charge and Discharge Controller

Advanced Hybrid Wind / Solar Charge Controller. User Manual

MoistureMatch A next generation grain tester

SC-Max 48V series. User Manual. Solar Charge Controller 30A

Using Apollo Solar Remote Monitoring Software

MPPT SOLAR CONTROLLER FOR MODELS: 20A baterai 12V 24V

Maximum Power Point Tracking (MPPT) KA1224MPPT20A KA1224MPPT40A. Solar Charge Controller. User Manual 20A

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

EPAS Desktop Pro Software User Manual

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Support. EMROL Your power partner

Rover Series. Rover 20A 40A Maximum Power Point Tracking Solar Charge Controller

SP PRO KACO Managed AC Coupling

SC SERIES SOLAR CONTROLLER USER MANUAL Ver 1.0

PWM-High Voltage Charge controller. User s Manual. Models available: 72V to 240V in 20A or 40A

SMT. Installation and Operation Manual. Model:SMT WITH MPPT TECHNOLOGY

NEC Energy Solutions ALM 12V35 Batteries with

Sól Dual Voltage Buck Boost Solar Charge Controller Connection & Operation V1.00

Manual Installation & Operation

BRAKE TESTER DECELEROMETER

MAXIMIZER-II Progressive Nitrous Controller INSTALLATION AND USER MANUAL. MAXIMIZER-II rev A

High-Tech Solar System

2.1.Steca Solsum. Solsum 8.0c. Solar Charge Controller. Solsum 5.0c. Solsum 6.6c. Solsum 10.10c. 8.8c

INSTRUCTION MANUAL EPSOLAR. Tracer-3215RN. Maximum Power Point Tracking Solar Charge Controller

AeroVironment Universal Solar Pump Controllers

MPPT75HV MAXIMUM POWER POINT TRACKING SOLAR BATTERY CHARGE CONTROLLER

INSTALLATION & OPERATION MANUAL

Instruction of Solar Charge Controller. User s Manual

Harness the Power of the Sun

Quick Start Instructions For

PV Charge Controller SBC-6108 / 6112 / 6120 / 6130

Rev. U8e PL80e. Advanced PWM Solar Charge Controller. User Guide. Read this before installing. Solar Charge Controller

INSTRUCTION MANUAL EPSOLAR. Tracer-4215RN. Maximum Power Point Tracking Solar Charge Controller

KEMKRAFT ENGINEERING, INC. MODEL KEI-234 STEERING WHEEL TORQUE/INCLINOMETER TESTER

IMEON 9.12 USER MANUAL

DANGER. The Conext products below can utilize Load Shedding and Load Shifting:

Automatic Genset Controller, AGC-4 Display readings Push-button functions Alarm handling Log list

Operating Manual MP-3739

Dual Voltage Solar Power Charge Controller Board Connection & Operation V2.xx

The Traveler Series: Wanderer

Advanced User Manual

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

The Traveler Series: Adventurer

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

WITH TRAKSTAR TM MPPT TECHNOLOGY. Installation and Operation Manual. Model: SS-MPPT-15L

MPPT Solar Charge Controller INSTRUCTION MANUAL

EV Display User Guide

TRACER 1206/1210/1215

Orica Seismic Electronic Initiation System OSEIS TESTER. Manual

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

The Traveler Series TM : Adventurer

Duo Battery Charge Controller

LS0512R Solar Light Controller

PHOTO VOLTAIC CHARGE MODULE MULTI POINT TRACKING

SP PRO ABB Managed AC Coupling

PL User Guide. PL User Guide. Advanced Solar Charge Controller. Simple, easy to read. User Guide. Read this before installing BOOST

PV Generation System. Solar Charge Controller SPECIFICATION

SOLAR CHARGE CONTROLLERS

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

User Manual. 3kW Hybrid PV Inverter HX-3000

Installation and Operating Instructions. Solar System Controller ISC3030

User s Manual Wind/Solar Hybrid Controller

SNMP dedicated to ORVALDI Solar Infini

NSTHAI. Solar Light Controller

SMPPT. Solar Charge Controller with Maximum Power Point Tracking. Installation & Operation Manual

Reference: Photovoltaic Systems, p References: Photovoltaic Systems, Chap. 7 National Electrical Code (NEC), Articles 110,

Service Manual BLACK DIAMOND SERVICE MANUAL. V.160 November

The Traveler Series: Wanderer

SCC-MPPT Solar Charge Controller

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

Lester Electrical ChargerConnect App User s Guide

400W Solar Charger Maximum Power Point Tracker

SCC-MPPT Solar Charge Controller

Eclipse Solar Suitcase

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

200W Solar Charger Maximum Power Point Tracker

CP Data Sheet I-CAM Introduction: I-CAM, Integrated Calibration And Automated Mapping CP Engineering Systems Ltd.

Installation and Operation Manual. Dual Battery Charging Solar Controller. for RVs, Caravans, and Boats. Ratings. Rated Solar Current 25 Amps

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

Rutland Remote Display -Model Installation and Operation

LS1024R / LS1524R / LS2024R. Solar Light Controller INSTRUCTION MANUAL

BigStuff3 - GEN3. 1st Gear Spark Retard with Spark Retard Traction Control System (SR 2 ) Rev

LS0512 Solar Charge Controller

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Solar System Controller

Super Brain 992 Palm Charger

Solar Power For Your RV

Hi-Z USB Wireless. Introduction/Welcome

SolarPower. User Manual. Suitable Products: Three-phase grid-tie inverter with energy storage. Three-phase off-grid inverter

Whizbang Jr. Installation Instructions

Solar Charge Controller

Baintech PowerTop. User Operation Manual. This manual must be read in its entirety before operating the PowerTop and retained for future reference.

Transcription:

w w w. r o c s o l i d. c o m. a u PowerSTAR PS-2024-D Maximum Power Point Tracking Solar Regulator Contents 1 Quick Start Guide... 2 2 Specifications... 3 2.1 General Operation... 3 2.2 Absolute Maximum Ratings... 3 2.3 Metering Accuracy... 3 2.4 Metering Range... 3 3 The Regulator... 4 3.1 Regulator Parts... 4 3.2 System Features... 5 4 PowerSTAR Settings Manager... 6 4.1 Battery Settings... 7 4.2 Photovoltaic Settings... 8 4.3 Load Settings... 8 4.4 Temperature Compensation... 10 4.5 Data Logging... 10 5 On board display module... 10 5.1 Initialisation... 10 5.2 Menu System... 11 5.3 Settings... 12 5.3.1 Setting Voltages... 13 5.3.2 Setting Times and Days... 14 5.3.3 Enable/Disable Settings... 14 5.4 Data Logging... 15 1

1 Quick Start Guide Ensure that the correct polarity is observed when making the connection to the battery or solar panel, or the fuse will blow. Connect your PowerSTAR to a 12V battery, it is normal for the connection to the 12V battery to spark as the large capacitors charge up. Ensure that the regulator is not in an explosive environment when installing. Plug in the RS-232 connection to your PowerSTAR with the other end into a PC serial port. If a serial port is not available then a RS-232 to USB converter can be used. Start the program PowerSTAR.exe and connect to the regulator, if you have any problems see section 4. Click the Get All Settings button in the PowerSTAR settings manager window to see all of the settings on the PowerSTAR. Change all of the settings you require by entering in the respective values. Once you have entered in all of your desired settings, click on the Send All Settings button, once all of your settings have been successfully saved on the regulator you will be informed with a message box. Your regulator is now set up and ready for use. You can save these settings for use again in the future by pressing the Save File button in the PowerSTAR settings manager. These saved settings can be used again in the future to program many regulators with the same settings by pressing the Open File button and then pressing the Send All Settings button. Connect the battery, photovoltaic array and load as shown in Figure 1 PS-2024 B+ S+ L+ L- S- B- PV array Load of up to 20A Figure 1 2

2 Specifications 2.1 General Operation Battery Voltages... 12V or 24V PV Voltages... 12V, 18V or 24V 1 2.2 Absolute Maximum Ratings These values must never be exceeded Maximum voltage across battery terminals... 60V Minimum voltage across battery terminals 2... 0V Maximum voltage across photovoltaic terminals... 65V Minimum voltage across photovoltaic terminals... -65V Maximum continuous input current from PV array... 20A Maximum continuous input power from PV array ( 24Vin, 24Vout ) 3... 500W Maximum continuous input power from PV array ( 24Vin, 12Vout )... 250W Maximum continuous input power from PV array ( 12Vin, 12Vout )... 250W Maximum continuous output current to battery 4... 20A Maximum continuous load output current... 20A Maximum continuous load output power... 240W Maximum ambient operating temperature... 60 C Minimum ambient operating temperature... -30 C Maximum lightning induced current spike per terminal pair 5... 400A Maximum lightning induced spike energy across all terminals... 5.4J 2.3 Metering Accuracy 6 Battery voltage... +/- 2% Solar voltage... +/- 5% Battery current... +/- 2% and +/- 0.1A Amp hours 7... +/- 2% and +/- 1.5Ah Time to float 4... +/- 5mins 2.4 Metering Range Maximum battery voltage... 34V Minimum battery voltage... 9V Maximum solar voltage... 50V Minimum solar voltage... 0V Maximum battery current input... 20A Minimum battery current input... 0A Maximum battery current output... 10A Minimum battery current output... 0A Maximum battery temperature with sensing lug... 60 C Minimum battery temperature with sensing lug... -30 C 1 12V and 18V solar input will only work with a 12V battery. 24V solar input will work with 12V or 24V battery. 2 The reverse polarity protection will blow the fuse if this condition is violated. 3 24Vin implies 72 silicon photovoltaic cells in series, commonly referred to as a 24V panel. 24Vout implies 12 lead acid cells in series, commonly referred to as a 24V battery. 4 Current limiting will be implemented by the regulator if this condition is exceeded. 5 Maximum current for 0.4 s. 6 Voltage reading accuracy at regulator terminals, quoted tolerance is worst case over full operating temperature range. 7 This value will be less accurate if the unit is disconnected or the value is read before that particular day has completed. 3

3 The Regulator 3.1 Regulator Parts Figure 2 shows the various parts of the PS-2024 solar regulator 1. LEDs 2. Communications port 3. Temperature compensation port 4. Screw terminal block 5. Fuse holder 6. Display 7. Enter Button 8. Cancel Button 9. Up Button 10. Down Button 7 9 8 6 10 1 5 4 3 2 Figure 2 The RS-232 translation unit connects to the auxiliary port as shown in Figure 3. Figure 3 4

3.2 System Features The PowerSTAR-2024 regulator has the following features: Maximum Power Point Tracking On board user interface User settings for: o Boost voltage o Equalisation voltage o Equalisation hold time o Equalisation frequency o Equalisation attempts before returning to normal operation o Absorption voltage o Absorption hold time o Float voltage o Boost return voltage o Load disconnect voltage o Special load disconnect voltage 5 o Instantaneous load disconnect o Load reconnect voltage o Solar open-circuit connect voltage o Solar sunset voltage o Solar sunset time o Solar sunrise voltage o Solar sunrise time o Load always on option o Load on time o Load on conditions Sunset Before sunrise External button press o Load off conditions Timeout Sunrise External button press Moisture resistant PCB conformal coating Connection via a PC RS-232 serial port Easy to use Graphical User Interface for the PC Ability to save configuration settings on PC Rapid and simple regulator upload of saved configuration settings Storage for 400 days datalogging Datalogging for: o Amp hours input o Amp hours output o Maximum battery voltage o Minimum battery voltage o Time to float o Days to next equalisation Export of datalogging information to universal spreadsheet format for further analysis Battery regulation modes: o Boost o Equalisation o Absorption o Float Lightning induced transient protection 6 Solar reverse polarity protection Battery reverse polarity protection Advanced MPPT control algorithm Temperature compensation 8 Optional, used if equalisation will be performed the next day to ensure that the battery can receive a good charge state at least once in the period of equalisation. 9 This regulator has been designed and tested to survive induced voltage spikes due to nearby lightning striking. It would not survive a direct lightning strike. 5

4 PowerSTAR Settings Manager The PowerSTAR settings manager is used to configure and download information from your PowerSTAR maximum power point tracking regulator. The PowerSTAR settings manager setup file is labelled PowerSTARsetup.exe. Run this file to install the program. Once installed, run the PowerSTAR settings manager, the window in Figure 4 should be seen. Figure 4 Choose which COM port on your PC you wish to connect via by altering the value in the pulldown box in the top left of the window. Connect the RS-232 cable between the PC and the PowerSTAR. Apply 12V to the battery terminals of the regulator if power is not already applied. Click the Connect button. The tick box in the connect button will be enabled if a successful connection has been established. If the tick is not seen, check that the COM port is not being used by another application, also check that the correct port has been selected and that power is applied to the unit. Click the Get All Settings button to display all of the current settings. Enter in all of the settings you wish to modify. Placing the mouse cursor over a label will bring up a tip explaining the setting. Click the Send All Settings button. A message box will appear verifying the settings were correctly recorded on the regulator. Once all settings have been determined, you can save your settings for later use by pressing the Save file button. 6

If you wish to use these settings again at a later date, just click the Open file button and then the Send All Settings button. By doing this, setting up multiple units is a quick and simple process. Click on the Continuous Update tick box to see the current operation of the regulator. The computer will poll the regulator frequently and display that information. 4.1 Battery Settings Boost Maximum power is transferred to the battery until this voltage is reached Equalisation A 12V lead acid battery consists of 6 cells in series. As the battery is charged and discharged, the state of charge between individual cells may vary. An equalisation process is routinely performed to ensure that one cell does not become significantly more discharged than the other cells, usually once every 20-40 days (Equalisation Frequency). Batteries are equalised by routinely increasing the voltage of the battery beyond normal levels. Any cell that is already fully charged will turn this excess energy into heat, but any cell undercharged will get a chance to reach a fully charged state. The equalisation attempts setting is there to prevent damage to the battery if there is not enough solar input to successfully complete equalisation. A normal setting would result in the regulator returning to normal operation after attempting to reach equalisation for 3 days. Absorption The battery is held at the absorption voltage for the absorption hold time (usually 90-180mins) to put the last 10%-30% of charge in to the battery. Float Also known as trickle charge. This keeps the battery topped up and only a small amount of current is transferred unless a load is placed on the battery. Boost Return Once the battery voltage drops below the boost return value, the battery charging cycle starts again. Load Disconnect Once the battery is completely discharged, the load is disconnected. The battery voltage must be below the load disconnect voltage for 5 minutes. This prevents any short term loads or high inrush startup currents from disconnecting the load Special Load Disconnect Set this value to the same voltage as load disconnect if this setting is not required. This is an option to increase the chance of reaching equalisation during low light periods. The load disconnect voltage is internally changed to the special load disconnect voltage the day before attempting equalisation. By setting this value to a higher voltage, the battery will not be as deeply discharged, increasing the chance of equalisation. Instantaneous Load Disconnect The load is instantly disconnected if the battery voltage drops below this value. For the PS-2024, we recommend this value is greater than 9V. Load Reconnect The load will be reconnected if the voltage increases above the set level unless in night light mode. As a night light controller if the load is disconnected due to low voltage, the load will not come on again until the next day. 7

Battery Voltage Figure 5 shows the battery charge voltage over time. The black line shows the charge regime over a normal cycle and the grey shows the change when going into equalisation mode. Boost Equalise Absorption Float Boost Absorption Float 4.2 Photovoltaic Settings Figure 5 Solar O/C Connect The regulator connects the panel to extract power when the solar voltage increases above the set level, and disconnects when below. Solar Sunset When the solar voltage stays below the set voltage for the set time (eg 6V for 5 minutes) the regulator goes into night mode. If the load option is set to turn on at sunset, the regulator will connect the load to the battery. The sunset voltage must be at least 1V less than sunrise and should be timed for at least 5 minutes. Solar Sunrise When the solar voltage stays above the set voltage for the set time (eg 7V for 5 minutes) the regulator finishes the datalogging for the day and initiates the next days datalogging. If the solar voltage increases above the Solar O/C Connect voltage, the regulator instantly connects the solar panel and increments the datalogging day. This is done so that when the regulator is first connected it does not take 5 minutes before generating power. 4.3 Load Settings Normal load control For this operation, the only Load On Condition is Always on. The load will be connected to the battery whenever the battery voltage is greater than the load reconnect voltage. The load will be disconnected if the battery voltage drops below the load disconnect voltage as described above. 8

Night light control, on at sunset, off after timeout For this operation, the only Load On Condition is Sunset, and the only Load Off Condition is Timeout. The Load On Time is set to the number of minutes that the load should be connected. The load will be disconnected early if the battery voltage drops below the Load Disconnect voltage as described earlier. Night light control, on at sunset, off at sunrise For this operation, the only Load On Condition is Sunset, and the only Load Off Condition is Sunrise. The load will be disconnected early if the battery voltage drops below the Load Disconnect voltage. Night light control, on at sunset, off after timeout, on before sunrise, off at sunrise This operation is used if the light is not needed all night long, only for a set time after sunset and before sunrise. The Load On Conditions are Sunset and Before Sunrise, and the Load Off Conditions are Timeout and Sunrise. The Load On Time is set to the number of minutes that the load should be connected for the first period of the night. The load will be disconnected early if the battery voltage drops below the Load Disconnect voltage as described earlier, if this occurs the load will not be connected again until more power is transferred to the battery (i.e. not until the next night). The On Time Before Sunrise is set to the number of minutes before sunrise that the load should be connected. This regulator calculates the time to turn the load on based on the last sunrise. The first time the regulator is connected, it will not know when sunrise actually occurs. Therefore the first time it is connected, the load on before sunrise will either be late, or will not come on at all. But subsequent times it will turn on unless the battery voltage has dropped below the load disconnect voltage during the night. Settings examples The solar sunset voltage should always be at least 1V less than the solar sunrise voltage. The solar sunset and sunrise times should always be more than 5 minutes, this decreases the change of the light turning on and off multiple times when intermittent cloud is present at sunrise or sunset. To run a light from sunset to sunrise. o Load on time = 960 minutes o Load on before sunrise = 0 minutes o Load on conditions enabled Sunset o Load off conditions enabled Timeout Sunrise To run a light for 7 hours after sunset and 2 hours before sunrise. 10 o Load on time = 420 minutes o o o Load on before sunrise = 120 minutes Load on conditions enabled Sunset Before Sunrise Load off conditions enabled Timeout Sunrise 10 As the seasons change, the time between the light turning off and on again will vary. The light will run continuously all night if the time between turn off after sunrise and turn on before sunset is less then 5 minutes. This prevents rapid power cycling of the light which can damage certain lights. 9

4.4 Temperature Compensation Temperature compensation for battery charging can be performed by the PS-2024 by connecting a PS-TS, temperature sensing lug to the two pin header near the communications port. The solar regulator needs to be set up for temperature compensation in the PowerSTAR Settings Manager software. 4.5 Data Logging Press the Data Logging button to see the datalogging window. Enter the number of days of data to download. Click on Download, a dialog box will appear to save the file. The data is saved as.csv format and can be opened in any spreadsheet program for graphing or analysis. The data record period is from sunrise to sunrise. This way useful information can be obtained about when during the night a light was turned off due to low battery voltage by analysing the ampere hours out for the night. Datalogging from other regulators is frequently recorded from midnight to midnight, which can make data analysis extremely difficult. By logging sunrise to sunrise, the AH in figure shows the energy transferred to the battery during the day. The AH out shows the energy transferred to the lamp during the night. Maximum and minimum battery voltages for the day are recorded. The time to float is the amount of time in hours between the regulator first connecting the PV array and the battery reaching float mode. Days to next equalisation shows the number of days until next attempting equalisation. Run time shows the number of hours between sunrises, or the number of hours that the regulator had been connected. 5 On board display module The display module is provided for setup and interrogation of the regulator. This module can change settings, show current operating parameters and display logged information. Figure 6 shows the button configuration of the module. The menu structure of the module is navigated by pressing the buttons Up, Down, Enter and Cancel. Enter Cancel 5.1 Initialisation LCD Figure 6, button configuration Up Down The PS-DISP should be connected to the solar regulator after the battery terminals have been connected to the regulator. When the module first starts up, it shows the welcome screen of PowerSTAR for 2 seconds and then the current operation of the regulator it is connected to. Figure 7 shows the screen visible after the welcome screen. This Current Operation screen shows various operational parameters on the solar regulator. 10

Current Operation Batt Voltage = 12.8V Solar Voltage = 17.1V Batt Current = 12.1A Load Current = 1.3A Load state = On Charge mode = Absorption Figure 7, Displaying current operation Pressing any button during the Current Operation screen changes to the top-level menu screen. If a PC is connected to the display in this mode and the PC requests information then the display will temporarily show the text BUSY superimposed over the screen. The busy message will remain until all the requests from the PC have been met. 5.2 Menu System The top-level menu is broken down into the sections of: Current Operation Settings Data Logging From the top-level menu, the buttons Up and Down change the text that is highlighted, Enter selects the highlighted option and Cancel takes the screen back to Current Operation. Figure 8 shows the menu system under Settings, Battery Voltages, with the option Boost Voltage highlighted. Figure 9 shows the same menu after the Down button has been pressed once. When there are more options than can fit in a screen, the screen will scroll one line from the bottom as shown in Figure 10. Battery Voltages: Boost Voltage Equalisation Voltage Absorption Voltage Float Voltage Boost Return Voltage Load Disconnect Volt Figure 8, menu system highlighting 11

12 Battery Voltages: Boost Voltage Equalisation Voltage Absorption Voltage Float Voltage Boost Return Voltage Load Disconnect Volt Figure 9, menu system highlighting Battery Voltages: Equalisation Voltage Absorption Voltage Float Voltage Boost Return Voltage Load Disconnect Volt Spec Load Disconnect Figure 10, menu system scrolling Pressing the Enter button will either take the screen to the next level of menu, or display the current setting and allow the user to change this setting. Pressing the Cancel button takes the display back to the previous menu level. 5.3 Settings The settings menu hierarchy is defined below Settings Battery Voltage Boost Voltage Equalisation Voltage Absorption Voltage Float Voltage Boost Return Voltage Load Disconnect Voltage Special Load Disconnect Volt Instant Load Disconnect Volt Load Reconnect Voltage Battery Timing Equalisation Hold Time Absorption Hold Time Equalisation Frequency Equalisation Attempts Equalise after Low Volt Disc Solar Settings Open Circuit Connect Voltage Solar Sunset Voltage Solar Sunrise Voltage Sunset Time Sunrise Time

Load Settings Load Always On On at Sunset On Before Sunrise On External Button Off at Timeout Off at Sunrise Off External Button Load On Time On Before Sunrise Time Temperature Settings Temperature Compensation Maximum Battery Voltage Use Temperature Limits Low Temperature Limit High Temperature Limit LCD Settings Backlight Brightness LCD Viewing Angle 5.3.1 Setting Voltages When entering the voltage setting the display will be similar to Figure 11 (depending on the actual setting being modified). Upon entering this level of the menu, the PS-DISP displays the existing regulator setting. If the user presses Enter in this screen, the next display shown will be similar to Figure 12. The menu goes back to the previous page if the user presses Cancel. The user presses the Up and Down buttons to modify the value in each digit, pressing Enter to move to the next digit. The setting will not be saved if the user presses Cancel at any time during this process. Figure 13 shows the display when the last digit is modified. If the user presses Enter then this setting will be checked for validity (ie within specified ranges of the relevant regulator model). If valid then the value is sent to the regulator, if not valid then an error message is displayed. Battery Voltage Settings Boost Voltage 14.6V Press Enter to modify Press Cancel to exit Figure 11, Setting Voltages 13

Battery Voltage Settings Boost Voltage 14.6V Up/Down to change digit value Enter for next digit,cancel exits Figure 12, Setting Voltages Battery Voltage Settings Boost Voltage 14.6V Up/Down to change digit value Enter to save,cancel to discard Figure 13, Setting Voltages All communications with a PC is disabled while changing settings. For communications with a PC, the display needs to be within the menu structure and not modification of settings. 5.3.2 Setting Times and Days The setting of times (for charge and load control) and days (for equalisation) is similar to section 5.3.1, but with either minutes or days after the number and no decimal place. 5.3.3 Enable/Disable Settings The only options for Enable/Disable settings are for the option to be Enabled or Disabled. Figure 14 shows the setting before modification. Figure 15 shows the screen during modification of the setting. Pressing the Up or Down button on this screen will result in the highlighted value changing between Enabled and Disabled with each button press. Load Settings On at Sunset Enabled Press Enter to modify Press Cancel to exit Figure 14, Setting Voltages 14

Load Settings On at Sunset Enabled Up/Down to change value Enter for next digit,cancel exits Figure 15, Setting Voltages 5.4 Data Logging The user can look at information that has been logged by the solar regulator by selecting Data Logging at the lowest level menu. Information displayed includes: Day (number of days before today) Ah in (energy in) Ah out (energy out) Maximum battery voltage over the day Minimum battery voltage over the day Time to float The length of the day logged The number of days until next equalisation attempt Flags (see the document PowerSTAR datalogging flags for further explanation) Data from xxx days ago Ah IN xxx.xah V B(MAX) xx.xv Ah OUT xxx.xah V B(MIN) xx.xv Time to float xx.xh Logged day length xx.xh Days to next equalise xxx Flags xxx Figure 16, Viewing logged data Figure 16 shows the generic information displayed for data logging. The user changes the day viewed by pressing Up or Down button which increments/decrements the day counter respectively. Entech Electronics, trading as Ingenium Ruggedised Technologies 37 Belford Ave Devon Park, SA 5008 Ph (+61 8) 8245 6789 Fax (+61 8) 8245 6788 www.roc-solid.com.au sales@roc-solid.com.au 15