Temperature Programming Quick Reference Guide

Similar documents
SPEK PRO MONITOR AND CONTROL

NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK.

Flow Chart Programming Instructions for : VOLTMETER 2 1/16

Programming Instructions for : Pressure 2 1/16 + DOWN MODE UP. Spek Pro Fuel Rail Pressure Gauge

FEATURES: SPEK PERFORMANCE GAUGE FEATURES:

Flow Chart Programming Instructions for : Transmission Temperature 2 1/16 START HERE PROGRAM MAIN MENU

FEATURES: SPEK PERFORMANCE GAUGE TACHOMETER FEATURES:

NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK.

Wiring Installation Instructions for : Pressure. Wiring Installation Instructions for : Temperature. 2 1/16 Spek Pro Professional Racing Gauge

NEXUS. Introduction SENSOR MODULE &

Optional: Wiring a Relay for Gauge Controlled Output

INSTALLATION INSTRUCTIONS MECHANICAL GAUGES

UNIVERSAL GAUGE WIRE HARNESS

Replace light bulb with the same number bulb as the one removed. White Wire: Connect to +12 Volt Lighting

Replace light bulb with the same number bulb as the one removed. White Wire: Connect to +12 Volt Lighting

INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH

General Information. Installation Tips. Connections

INSTALLATION INSTRUCTIONS THERMOCOUPLE EXPANSION MODULE

PRO-COMP/PHANTOM TACH

Oil Pressure Display Gauges Part numbers: Analog Oil/Fuel SAE Pressure Gauge psi Analog Oil SAE Pressure Gauge.

FOR SERVICE SEND TO: AUTO METER PRODUCTS, INC. 413 W. Elm St., Sycamore, IL USA (815) us at

10 Ch Peak & Hold Injector Driver PN

Part Number Analog EGT Gauge

Part Number Analog Style 15 PSI Fuel/Boost Pressure Gauge. NOTE: Faceplate Configuration Instructions Included on Separate Sheet

P/N X-SERIES GAUGE VOLTAGE 8 TO 18V

Installation Instructions for AEM Tru Boost Boost Controller Gauge

1955 & 1956 CHEVROLET CAR INSTALLATION INSTRUCTIONS

Part Number cc/min Water/Methanol Injection Flow Gauge

INSTALLATION INSTRUCTIONS PRO PLUS WIDE BAND AIR/FUEL RATIO

E9X/E8X/E6X CHASIS VEHICLES (With N54 Motors)

Multi-Input Water/Methanol Injection Harness

Installation Instructions for AEM Serial Gauge

FULL SWEEP STEPPER MOTOR INSTRUMENT KIT INSTRUCTION MANUAL 1969,REDLINE, 2020 SERIES

Tach-Force Chevy Truck

3RD GEN CHALLENGER INSTALLATION INSTRUCTIONS

Classic Instruments Camaro. Installation Manual. Revised: January 6, 2015 Page 1

HI-FLOW FUEL RAIL. Installation Instructions for Scion tc & xb AEM Fuel Rail AN Hose adaptor

Classic Instruments Cluster. Installation Manual

VW/AUDI MK7 VEHICLES

Classic Instruments Chevelle. Installation Manual

Classic Instruments. Six Pack. Installation Manual

Classic Instruments Ford F100. Installation Manual

Chevy Truck

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

Classic Instruments Chevy. Installation Manual

Installation Instructions for: Channel Thermocouple Amplifier

Internal MAP Water/Methanol Injection Controller ,

AUTO-BLiP. User Manual Porsche INTELLIGENT DOWNSHIFTS. Version 1.2

Classic Instruments & 1956 Chevy. Installation Manual

NEW VINTAGE INSTRUMENT AND GAUGE KIT INSTALLATION INSTRUCTIONS

ODY-19-1 AIR PRESSURE GAUGE

Classic Instruments Ford. Installation Manual

6 November Ford Powerstroke 6.0/7.3L X-Monitor 1 BD X-MONITOR Ford 6.0/7.3L Powerstroke

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.7

Classic Instruments. Ultimate Speedometer & Speed-Tachular. Installation Manual

AUTO-BLiP. User Manual Chevrolet Corvette. Version 1.2

Chevy Truck

AUTO-BLiP. User Manual Lotus INTELLIGENT DOWNSHIFTS. Version 1.0

INSTALLATION GUIDE Six Gauge Universal Digital Dash Panel Part Number: DP10002

Chevy Truck

ODY-01-1 or ODY-01-2 SPEEDOMETER

Ford Mustang. Installation Manual

HLY-1111 HEAD TEMPERATURE GAUGE

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6002 YEAR SERIES:

DLKEK3HN INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Table of Contents

INSTALLATION GUIDE Chevrolet Monte Carlo Dash Panel Part Number: DP9002 Year Series:

INSTALLATION INSTRUCTIONS 5" DUAL CHANNEL ULTIMATE TACH MODEL 6881, 6883, 6884, Dual Channel 1 CH 2

Mustang. Installation Manual

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6003 Year Series:

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

Chevy Truck

AUTO-BLiP. User Manual Ford Mustang INTELLIGENT DOWNSHIFTS. Version 1.2

advanced FLOW engineering Instruction Manual P/N:

NEW VINTAGE INSTRUMENT AND GAUGE KIT INSTALLATION INSTRUCTIONS 3-1 INSTRUMENT KIT REV

Part Number AEM 4-CH WIDEBAND UEGO CONTROLLER

UTV-1200 Multi Gauge for 2008 Yamaha Rhino

31 January / Universal Dash-Top X-Monitor 1 BD X-MONITOR. Universal Top Button Dash-Mount Gauge System

BusPro Series Instruction Manual

Components. Options Accessory Harness USB Charger. Quick Connector. Hook & Loop / Cable-ties. RFID Antenna. Module. Main Harness.

CLEAN POWER TM CPS Series Operator s Manual

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

TRU-TIME ADJUSTABLE CAM GEAR Part Number: BK & BK

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6004 Year Series:

WARNING: DO NOT USE HAND-HELD 2-WAY TRANSCEIVERS INSIDE YOUR VEHICLE WHILE DRIVING.

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

Part Number DP6003 Chevy Truck Digital Dash YEARS 67-72

There are two types of installations depending on how the current nitrous oxide system is installed.

SCHNITZ MOTORSPORTS PNC-202, 2-STAGE PROGRESSIVE NITROUS CONTROLLER USER MANUAL AND INSTALLATION GUIDE NOS PULSE FREQUENCY

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

MCL-30K-TCH. Remove nuts/screws and clamp to remove factory gauges 1 MAN#650336

Water/Methanol Failsafe

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

Part# Accessory Power Distribution Module

INSTALLATION GUIDE Ford Mustang Digital Dash Panel Part Number: DP7009 Year Series:

WARNING: DO NOT USE HAND-HELD 2-WAY TRANSCEIVERS INSIDE YOUR VEHICLE WHILE DRIVING.

GM Throttle Body Adapter Harness User Manual

Classic Instruments. Belera. Installation Manual

INSTALLATION GUIDE Chevrolet Impala/Caprice Digital Dash Panel Part Number: DP1208 Year Series: 1968

Transcription:

Temperature Programming Quick Reference Guide Normal Mode Dial Brightness (press one at a time) Peak Mode Factory Default Reset (Hold for 5 seconds) High Alert Setting Mode Use LEFT or RIGHT buttons to select high alert warning signal. Low Alert Setting Mode Use LEFT or RIGHT buttons to select low alert warning signal Choose from one of seven colors. Red, Blue, Green, Purple, Yellow, Orange, White. Color Select Mode Use LEFT or RIGHT buttons to select Background color. Use LEFT or RIGHT buttons to adjust pointer brightness Pointer Brightness Mode (Hold for 5 seconds) Dial Brightness Mode Use LEFT or RIGHT buttons to select Background Brightness. Return to Normal Mode Save changes and advance to next menu Depressed Buttton When pressed together exit menu without changes FOR SERVICE SEND TO: SPEK-PRO SERVICE 413 West Elm Street Sycamore, Illinois 60178 USA www.spekpro.com sevice@autometer.com (866) 248-6357 1 2650-1687--00 7/24/13

Flow Chart Programming Instructions for : Temperature Program Main Menu (Press one button at a time) START HERE Main Menu ONE AT A TIME DOWN UP - + NORMAL LIGHTING NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK. NORMAL LIGHTING NORMAL/DIAL BRIGHTNESS: ON POWER UP THE GAUGE READS THE TEMPERATURE SENSOR. Press the center button to advance to PEAK PLAYBACK. PEAK PEAK PLAYBACK: Reads the highest value displayed on the Gauge since the last time the PEAK value was displayed. PEAK value will be held in memory until erased by pressing the RIGHT or LEFT button while in the PEAK level Press the center button to advance to HIGH RED-LINE SETTING. PEAK PEAK PLAYBACK: Press the center button to advance to HIGH RED-LINE SETTING. OR OPTION:RESTORE FACTORY DEFAULT ONE AT A TIME DOWN UP - + HI HIGH RED-LINE SETTING: Press the down or up button to move dial pointer to the high threshold. Press the center button to save and advance to THRESHOLD SETTING. HI HIGH RED-LINE SETTING: Press the center button to advance to THRESHOLD SETTING. ONE AT A TIME DOWN UP - + THRESHOLD SETTING: Press the down or up button to move pointer to low threshold. Press the center button to save and advance to COLOR SCHEME. THRESHOLD SETTING: Press the center button to advance to COLOR SCHEME. ONE AT A TIME DOWN UP - + PEAK,,HI COLOR SCHEME: Press down and up buttons to select a color scheme. (OFF-VIOLET-BLUE-GREEN-YEL- ORANGE-RED-WHITE). Press the center button to save and advance to DIAL BRIGHTNESS. PEAK,,HI COLOR SCHEME: Press the center button to advance to DIAL BRIGHTNESS. OR OPTION :DEMO MODE ONE AT A TIME DOWN UP - + PEAK,,HI DIAL BRIGHTNESS: Press the RIGHT or LEFT command buttons to Control the brightness of the faceplate illumination. Press the center button to save and advance to NORMAL OPERATION. PEAK,,HI DIAL BRIGHTNESS: Press the center button to advance to NORMAL OPERATION OPTION:ADJUST POINTER BRIGHTNESS 2

Flow Chart Programming Instructions for : Temperature Submenu (enter from main menu) (Press two(2) buttons simultaneously for 5 seconds) PEAK OPTION:RESTORE FACTORY DEFAULT: While in PEAK PLAYBACK, press and hold the center and right buttons for five seconds. Dial pointer will step five times and return to zero. This will erase all user-programmed calibrations and settings, and return to NORMAL/DIAL BRIGHTNESS. Factory Default Settings Water Temperature..250 F Oil Temperature 270 F HI BOTH OPTION A:DEMO MODE: WHILE IN COLOR SCHEME, press and hold the center and right buttons for five seconds. Dial will scroll through the seven color schemes. The HI, and PEAK will light, and the dial pointer will move. Press the center button to return to NORMAL/DIAL BRIGHTNESS. Down Button Mode Button Up Button BOTH OPTION A:POINTER BRIGHTNESS: Press CENTER and LEFT buttons for five (5) seconds to enter pointer brightness mode. The dial pointer will start to flash and point to the upper right. ONE AT A TIME DOWN UP - + OPTION:POINTER BRIGHTNESS: Press LEFT or RIGHT buttons to adjust pointer brightness. Press the CENTER burron to save and return to NORMAL/DIAL BRIGHTNESS. B 3

Programming Instructions for : Temperature SPEK PRO MONITOR AND CONTROL Refer to the Flow Chart Programming Instructions while reviewing this guide. Gauge is field programmable by the operator while installed in the vehicle. This programming is accessed by pressing the control buttons located on the face or the meter dial, ONE AT A TIME. The Down and Up buttons move the pointer to a desired setting or controls the faceplate illumination. + DOWN MODE UP MAIN MENU NORMAL/DIAL BRIGHTNESS SUBMENU MODE BUTTON TO PROGRAM LEVEL. THEN BOTH CENTER AND LEFT OR CENTER AND RIGHT BUTTONS FOR FIVE SECONDS TO ENTER SUBMENU PEAK PLAYBACK OPTION:RESTORE FACTORY DEFAULT HIGH RED-LINE SETTING THRESHOLD SETTING COLOR SCHEME OPTION A:DEMO MODE DIAL BRIGHTNESS OPTION : ADJUST POINTER BRIGHTNESS 4

Programming Instructions for : Temperature PROGRAMMING STARTS IN MAIN MENU PROGRAM BUTTON ONE (1) AT A TIME IN THE MAIN MENU MODE. 1 NORMAL/DIAL BRIGHTNESS: On power up, the meter usually starts operation in NORMAL/DIAL BRIGHTNESS. Gauge reads the sensor value as temperature, pressure, etc. The Down and Up buttons will control the brightness of the dial lighting. Press the center Mode button to save the setting and advance you to PEAK PLAYBACK 2 PEAK PLAYBACK: Reads the highest value displayed on the gauge since the last time the PEAK value was displayed. PEAK value will be held in memory until erased by pressing the RIGHT or LEFT buttons while in the PEAK level. Press the center Mode button to advance to HIGH RED-LINE SETTING 3 HIGH RED-LINE SETTING: Water, Oil, Transmission, and Differential gauges have a programmable thermostat control to activate the existing cooling fan. Sets the point at which HIGH warning threshold is reached for that specific gauge. The Down and Up buttons will move the dial pointer to select HIGH RED-LINE SETTING. During normal operation the gauge constantly monitors the sensor value and compares it to the HIGH threshold. If the threshold is exceeded, the red HI indicator and fan are turned on. Press the center Mode button to save the setting and advance to THRESHOLD SET- TING 4 THRESHOLD SETTING: Set the Minimum Threshold: Sets the point at which warning threshold is reached for that specific gauge. The Down and Up buttons will move the dial pointer to select the THRESHOLD SETTING. During normal operation the gauge constantly monitors the sensor value and compares it to the threshold. If the sensor value drops below the threshold, the yellow indicator is turned on fan is turned off. Press the center Mode button save the setting and advance to 5 COLOR SCHEME 5 COLOR SCHEME: Set Faceplate Color Scheme: Operator can select the color of the gauge dial illumination. Each time you press the Down control button you scroll through dial color selection until the dial light goes off. Then press the Up button to reverse the scroll. Select your dial color illumination by pressing the center Mode button to save the setting and advance to NORMAL/DIAL BRIGHTNESS 6 DIAL BRIGHTNESS: Adjust the dial brightness for day or evening driving conditions The RIGHT and LEFT command buttons will dim or brighten the faceplate illumination. Press the center Mode button to save the setting and advance you to NORMAL OPERATION 2 5

Programming Instructions for : Temperature SUBMENU SUBMENU IS ACCESSED THROUGH THE MAIN MENU. FIRST GO TO THE APPROPRIATE LEVEL OF THE MAIN MENU AND THEN FOL THE INSTRUCTIONS IN THE PROGRAMMING F DIAGRAM TO ENTER THE SUBMENU. THE MODE AND UP OR MODE AND DOWN BUTTONS SIMULTANEOUSLY FOR 5 SECONDS TO ENTER THE SUBMENU AND ONE BUTTON AT A TIME WHILE IN THAT SUBMENU. OPTION:RESTORE FACTORY DEFAULT: While in PEAK PLAYBACK, Main Menu, Press and hold bot the CENTER and RIGHT buttons for 5 seconds. The dial pointer will step 5 times and return to zero (0). All user programmed settings will be erased and the gauge will return to NORMAL OPERA- TION. OPTION A:DEMO MODE: Displays the features of the meter. The pointer goes up and down the scale, the dial colors change and the HI, and PEAK warning indicators light. The DEMO MODE does not time out. If the gauge is turned off in the DEMO MODE, it will start up in the DEMO MODE. Press the Mode button to return the gauge to NORMAL operation. OPTION :POINTER BRIGHTNESS MODE: The Down and UP buttons adjust the dial pointer brightness to blend in with the original manufacturer s gauges and the owner s requirements. Press the Mode button to return the gauge to NORMAL/DIAL BRIGHTNESS. 6

Programming Instructions for : Temperature GAUGE CRITICAL CONDITION ALERT/OUTPUT GUIDE GAUGE TYPE TEMPERATURE ALERT FLASHES RED HIGH URE TACHOMETER HIGH PYROMETER HIGH NITROUS OXIDE URE BOOST URE HIGH AIR/FUEL VOLTMETER PROGRAMMING INFORMATION: TO RESET THE PROGRAM TO NORMAL OPERATION FROM ANY MODE THE UP AND DOWN BUTTONS SIMULTANEOUSLY. THIS SOFT RESET CANCELS THE INFORMATION YOU PROGRAMMED IN THAT MODE ONLY AND RETURN YOU TO NORMAL OPERATION. THE FACEPLATE WILL FLASH WHEN BUTTONS ARE DEED TO ACKNOWLEDGE COMMANDS. PROGRAMMING ERRORS WILL BE SIGNALLED BY FLASHING THE FACEPLATE LIGHTING PURPLE, BLUE, GREEN THEN ORANGE. IF PROGRAMMING IS INACTIVE FOR 120 SECONDS THE MODE WILL TIME OUT AND THE GAUGE WILL RETURN TO NORMAL OPERATION, EXCEPT FOR IN THE DEMONSTRATION MODE. THE DEMO MODE WILL NOT TIME OUT UNTIL THE CENTER MODE BUTTON IS ED. IF THE GAUGE IS TURNED OFF IN THE DEMO MODE, IT WILL START-UP IN THE DEMO MODE. TO RESTORE FACTORY DEFAULTS, THE MODE BUTTON ONCE TO ENTER THE PEAK PLAYBACK. THEN AND HOLD THE MODE AND UP BUTTONS FOR FIVE SECONDS. YOUR PROGRAMMING WILL BE ERASED BUT FACTORY PROGRAM WILL NOT BE AFFECTED. Factory Default Settings Water Temperature..250 F Oil Temperature 270 F 7

Wiring Installation Instructions for : Temperature SPEK PRO TEMPERATURE GAUGE PACKAGE CONTAINS: Temperature Gauge 1/8 eletric sender Wiring Harness Mounting Cup FEATURES: SPEK PERFORMANCE GAUGE FEATURES: INTELLIGENT ELECTRICAL GAUGES. GAUGES ARE PROGRAMMED THROUGH COMMAND KEYS ON FACEPLATE. STEPPER MOTOR DRIVES THE GAUGE POINTER OVER A 280 DEGREE SWEEP. WIDE-ANGLE-DIAL HAS A 15% LARGER VIEWING AREA ON A 2 1/16 GAUGE. PROGRAMMABLE 7 COLOR DIAL AND RED POINTER ILLUMINATION. OPTIONAL OUTPUT CONTROL MODULE. INSTALLATION INSTRUCTIONS: 1 DISCONNECT NEGATIVE (-) BATTERY TERMINAL. 2 VARIOUS MOUNTING SOLUTIONS ARE PRESENTED BY PROPARTS, LLC ON THEIR WEBSITE AT www.propartsllc.com DASH INSTALLATION: SELECT LOCATION IN THE DASH TO MOUNT GAUGE AND CUT A 2 1/16 HOLE. USE A FILE TO INCREASE THE HOLE SIZE IF REQUIRED. BE SURE THERE IS SUFFICIENT ROOM BEHIND THE HOLE FOR THE METER CASE AND THE CONNECTORS YOU WILL USE. 3 IF A SUITABLE HOLE IN THE FIRE WALL IS NOT AVAILABLE, CUT AN 11/16 HOLE. 4 Grommet MUST BE CUT TO PERMIT INSTALLATION OF WIRING HARNESS. (SEE DIAGRAM 1) 5 INSTALL THE GROMMET AND MOUNTING CUP ON THE WIRING HARNESS AS SHOWN IN DIAGRAM 1. GROMMET IS FOR THE HOLE IN THE FIREWALL. 6 DO NOT CONNECT WIRING HARNESS TO THE GAUGE UNTIL THE OTHER CONNECTIONS HAVE BEEN MADE AND TESTED 8

Wiring Installation Instructions for : Temperature 7 SELECT A LOCATION FOR MOUNTING THE SENDER. SENSOR MUST BE IMMERSED IN FLUID 3-6 MM FOR AN ACCURATE READING. 8 OIL, DIFFERENTIAL AND TRANSMISSION SENDERS MAY REQUIRE A MOUNTING HOLE BE DRILLED AND A 1/4 NPTF ADAPTER WELDED IN PAN.. 9 CLEAN THREADS IN MOUNTING FITTING AND SCREW SENDER UNIT IN HAND TIGHT. 10 USE TEFLON SEALING COMPOUND. TAPE IS NOT RECOMMENDED. 11 WITH WRENCH, TIGHTEN SENDER INTO BLOCK UNTIL SECURE. DO NOT OVER TIGHTEN. TEST ALL FITTINGS FOR LEAKS. 12 CONNECT THE RED (+12 VOLT SUPPLY) WIRE TO ON CIRCUIT THAT GETS POWER WHEN THE IGNITION IS TURNED ON. THIS CIRCUIT MUST BE FUSED BEFORE THE IGNITION SWITCH (5 AMP, FAST ACTING FUSE). 13 CONNECT THE BLACK WIRE TO A GOOD GROUNDING POINT ON THE CAR S CHASSIS. 14 CONNECT THE WHITE WIRE TO THE DIMMER VOLTAGE GOING TO THE DASH LIGHTS. THIS WILL CAUSE THE METER BRIGHTNESS TO TRACK THE BRIGHTNESS OF THE REST OF THE INDICA- TORS. 15 PLUG THE SENDER WIRING HARNESS INTO THE PACKARD FITTING ON THE SENSOR. 16 PLUG THE WIRING HARNESS INTO THE GAUGE AND MOUNT IN POD OR DASH. USE CARE WHEN CONNECTING OR DISCONNECTING THE WIRING HARNESS. PULL OUT EACH PACKARD FITTING CONNECTOR WHILE ING THE LOCK OF THE CONNECTOR FIRMLY. 17 FOR DASH MOUNTING, ATTACH MOUNTING CUP OVER THE BACK OF THE GAUGE AND HAND TIGHTEN. DO NOT OVER-TIGHTEN. MOUNT CUP BEFORE INSTALLING GROMMET. FAILURE TO DO SO WILL TWIST WIRES CAUSING A SHORT CIRCUIT. 18 POWER UP THE GAUGE AND INSPECT ALL CONNECTIONS. IF GAUGE IS OPERATING NORMAL, PROCEED TO PROGRAMMING MANUAL. TROUBLESHOOTING: 1 IF THE SENSOR PROBE IS DISCONNECTED FROM THE WIRING HARNESS, THE DIAL WILL FLASH RED FOR SIXTY SECONDS. THE DIAL WILL THEN RETURN TO NORMAL BUT THE HI AND LED S WILL REMAIN LIT UNTIL THE CONDITION IS CORRECTED. 2 DO NOT USE ANY SENDER ADAPTER THAT WOULD REDUCE THE SENSORS IMMERSION IN FLUID. FOR ACCURACY, SENSOR SHOULD BE 3-6MM IMMERSED IN THE FLUID IT IS MONITORING. 3 SENSOR CAN BE TESTED WITH AN OHM METER. CONNECT POSITIVE LEADS TO THE SENDER TERMINAL AND TO THE NEGATIVE GROUND. READING SHOULD BE AS FOLS: TEMPERATURE SENDER COLD (65ºF)...4 KΩ (OHM) TEMPERATURE SENDER HOT (250ºF)...240 KΩ (OHM) 2 9

Wiring Installation Instructions for : Temperature GAUGE 12-Pin Wiring Harness & Plug Grommet Firewall Grommet DIAGRAM 1 Black-Chassis Ground CUP Coil excess tube with wire tie Fuse A To Output Control Module Thermister Sensor Water Resistant Connector Optional relay, may use Dedenbear HPR or equivalent. White-12V Dash Lighting Headlight Switch Fused +12V Scramble Boost (Option) +12VDC +12VDC 1/8 Inch NDP +12VDC 85 87 87A ATo Red Ignition Switch Red-12V Ignition Switch CAUTION: 12 VOLT DC POWER MUST BE CONNECTED TO THE IGNITION POWER AFTER THE 20 AMP FUSE. OEM Thermostat Switch B Override Temperature Controller Output 86 30 +12VDC B : ALL SPEK GAUGES HAVE A PROGRAMMABLE HIGH AND LIMIT SETTING DETERMINED BY THE USER. WHEN A SETTING IS TRIPPED, AN OUTPUT SIGNAL IS GENERATED. THIS CAN BE USED TO SWITCH ON A RUGGED 35 AMP RELAY TO ACTIUVATE A TRANSMISSIN OIL COOLING FAN, OIL ENGINE KILL, ALARMS, ETC. GROUND Transmission Oil Cooling Fan Gauge PIN 8 Output/Purple WARNING: OUTPUT CONTROL MODULE NOT TO EXCEED 1.5 AMPS AT 12 VOLTS DC. WARRANTY WILL BE VOID IF INCREASED OUTPUT VOLTAGE OR CURRENT IS APPLIED. CAUTION:DO NOT REMOVE EXISTING FACTORY PATENTED WIDE ANGLE DIAL FOR SUPERIOR VISIBILITY U.S PATENT #7,278,749 032010 10

Wiring Installation Instructions for : Temperature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

Wiring Installation Instructions for : Temperature SPEK GAUGES AND CONTROLLERS ARE DESIGNED FOR 12V DC ELECTRICAL SYSTEMS WITH A NEGATIVE GROUND. DO NOT ADJUST THE GAUGES OR GAUGE PROGRAM WHILE DRIVING OBEY ALL RULES AND REGULATIONS OF HIGHWAY AND STREET DRIVING. INSTALL SENSOR AND WIRE AWAY FROM HIGH HEAT AND / OR VIBRATION AREAS. USE CARE WHEN CONNECTING OR DISCONNECTING THE WIRING HARNESS. PULL OUT EACH CONNECTOR WHILE ING THE LOCK OF THE CONNECTOR FIRMLY. IF THE BATTERY TERMINAL IS DISCONNECTED, THE AUDIO, CLOCK AND OTHER MEMORY DATA MAY BE LOST. THE NECESSARY DATA WILL HAVE TO BE RESET AFTER INSTALLATION. 12 MONTH LIMITED WARRANTY Spek-Pro/Auto Meter Products, Inc. warrants to the consumer that all Auto Meter High Performance products will be free from defects in material and workmanship for a period of twelve (12) months from date of the original purchase. Products that fail within this 12 month warranty period will be repaired or replaced at Auto Meter s option to the consumer, when it is determined by Spek-Pro/Auto Meter Products, Inc. that the product failed due to defects in material or workmanship. This warranty is limited to the repair or replacement of parts in the Spek-Pro/Auto Meter Instruments. In no event shall this warranty exceed the original purchase price of the Auto Meter instruments nor shall Spek-Pro/Auto Meter Products, Inc. be responsible for special, incidental or consequential damages or costs incurred due to the failure of this product. Warranty claims to Spek-Pro/Auto Meter must be transportation prepaid and accompanied with dated proof of purchase. This warranty applies only to the original purchaser of product and is non-transferable. All implied warranties shall be limited in duration to the said 12 month warranty period. Breaking the instrument seal, improper use or installation, accident, water damage, abuse, unauthorized repairs or alterations voids this warranty. Spek-Pro/Auto Meter Products, Inc. disclaims any liability for consequential damages due to breach of any written or implied warranty on all products manufactured by Auto Meter. FOR SERVICE SEND TO: SPEK-PRO SERVICE 413 West Elm Street Sycamore, Illinois 60178 USA www.spekpro.com sevice@autometer.com (866) 248-6357 12 12 2650-1687-00 7/24/13