kw. Tetris W FC/NG Water cooled freecooling chiller. General. Bullet points. Configurations

Similar documents
kw. Kappa Rev. Air cooled modular screw chiller & heat pump. Bullet points. General. Configurations

kw. Kappa Rev. Air cooled modular screw chiller & heat pump. Bullet points. General. Configurations

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

TEAL FC. Chiller with integrated Free Cooling system kw

CGAM. Air-cooled scroll chiller. Accessories. Customer benefits. Tracer CH530 Control. Main features. Energy saving options.

Kawasaki turbo chiller using water as a refrigerant. Feb. 4 th 2015 Kawasaki Heavy Industries, Ltd. Machinery Division Hayato Sakamoto

Advanced efficiency, precision cooling Design an HVAC system like no other

Advanced efficiency, precision cooling Design an HVAC system like no other

ZETA ECHOS. Chillers and heat pumps Air/water kw. General Air/Water chillers and heat pumps with axial fans and hermetic scroll compressors.

Advanced efficiency, precision cooling Design an HVAC system like no other

Blue e+ chillers with the principle

CXAM. Options. Accessories

NSM. R134a HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

eurammon Symposium 2017 Energy Efficiency and Life Cycle Costs of a NH 3 Evaporative Condenser System Georges Hoeterickx Evapco Europe BVBA

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

HFC R407C HEAT PUMP COOL DIGITAL COMPRESSOR. HFC R134a R407C HEAT DIGITAL PUMP HFC R407C HEAT PUMP DIGITAL. HFC R134a R407C HEAT DIGITAL PUMP HFC

VHA. Air cooled chiller with

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

AZURA. Air/water multifunctional chiller&heat pump, kw

Bitzer Friga Pack Catalogue

technical catalogue tetris KW Chiller and heat pumps air/water

NSM. R134a NEW HIGH EFFICIENCY ALSO AT PARTIAL LOADS ENERGY SAVING MICRO-CHANNEL COIL QUICK AND EASY INSTALLATION NIGHT MODE.

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Air-Cooled Screw Chillers RTAF kw. The best bundled in one. Our best.

Chinese Solar Cooling Conference Large Scale Solar AC System Project

Power conversion systems for energy storage. Engineering that stores

CATÁLOGO TÉCNICO COMERCIAL

HWT 1402/9603. free cooling

Air-Cooled Screw Chillers RTAF kw. The best bundled in one. Our best.

McQuay International WMC New Water Cooled Chiller with oil free centrifugal compressors

ENERGY & UTILITIES. Electricity Metering & Sub-Metering Concepts and Applications. BuildingsOne April 30, 2018

Progress all along the line

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

30HXC. Water-Cooled Screw-Compressor Liquid Chillers. Nominal cooling capacity kw. Features

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Product Catalog TSE Series Scroll Central Chillers

ARW DRY COOLERS AXIAL FANS VERSION, MEDIUM AND HIGH CAPACITY. CAPACITY FROM 20 TO 775 kw ARW DRY COOLERS

PLEXUS. Marine HVAC Components for Boats and Yachts CATALOGUE

AIR COOLED CHILLERS WATER COOLED CHILLERS

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Y-Flow TCHEY-THHEY

DC INVERTER VRF SYSTEMS C-VRF

01 Overview 02 ecoo. 03 HybridChiller. 04 Re-cooler. 05 Circuit Separation. 06 Services. Contents 04/2018. Overview. 02 Cooling innovation

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

APPENDIX A. Mechanical Equipment Sheets: York Chiller Marley Cooling Towers Calmac IceBank Storage Tanks Low Temp Air Cooling Coils

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

PROGRAMME OVERVIEW PRODUCTS FOR HYBRID VEHICLES

OMICRON V EVO. Multifunctional unit

Air conditioning. Residential and Light Commercial

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw. Features and advantages

Immersion chillers E 01

LOW AIR / DUAL THROW UNIT COOLER. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

30-450kW. Now Available. Ultima Compact Chiller Range kW. > Ultima Compact Chiller Range. Free-Cooling models up to 450kW.

PERFECTLY EVEN COOLING CIRCULAR DESIGN 360 CASSETTE. The World s First Circular Cassette. Circular LED Display Window. 360 Air Flow Blade-less

Product Catalog TSE Series Scroll Central Chillers

PREMIUM INVERTER DUCTED AIR CONDITIONING

VRF. For Commercial and Light Commercial

INVERTER FOR HYDRAULIC LIFTS

SOL-ARK 8K We guarantee it s the most effcient & affordable Multi-Mode Inverter in its class

Cool with the sun and save 60% of your power

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

6,3 108 kw R410A UP FLOW DOWN FLOW !"#$% "&'("!%)*(% "&+*'*"&$(#%,*'-%($."'$%)*(% ""!$+% "&+$&#$(%"(%/0*!'1*&%,)'$(% ""!$+% "&+$&#$( RCGROUP SpA

EVALUATION OF DEMONSTRATION PROJECT FOR ICE BEAR THERMAL ICE STORAGE SYSTEM FOR DEMAND SHIFTING. Final Report November 2006

30HXC. Water-Cooled Screw-Compressor Liquid Chillers PRO-DIALOG PRODUCT SELECTION DATA MAINTENANCE INSTRUCTIONS. Quality design and construction

AQWL/AQWH/AQWR 1404 to 2406

Specifications & Submittal

SyScroll Air EVO NEW

Midea VRFs/ Midea V5X. Timothy Huang Senior Engineer

Would you like to be free and enjoy electrical comforts just like at home?

SOL-ARK 8K. More Affordable: 5-15% less solar panels & 5-20% less batteries than others! World s Most Efficient Battery Inverter

30XW- 30XWH. Water-Cooled Liquid Chillers. Nominal cooling capacity kw Nominal heating capacity kw

kW. Ultima Screw Chiller Range kW. > Ultima Screw Chiller Range. Includes Ultima FreeCool Chiller Range

Pepco & Delmarva Power. Commercial & Industrial Energy Savings Program Grocery and Convenience Stores October 11, 2012

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

available in battery up to 4 units for a total of 560 kw

Air cooled chillers With axial fans and power ratings from 238 to 1600 kw with two-screw compressor

Well-to-Wheel Analysis of Electrified Drivetrains under Realistic Boundary Conditions and User Behaviour

Unit Report For CH-1 Replacement Project: Marlboro County High School Chiller Replacement 10/22/2018

Conditioning your ambient, maximising your comfort.

FOCS. Climaveneta Technical Bulletin. Air-cooled water chiller with helical fans kw

Key Differences Raising The Bar! with Perlick

DIMENSION AND SELECTION GUIDE

50% Raise your efficiency to a higher level. Equipped for silence and top performance. Optyma Plus TM New Generation

Inverter air to water heat pumps

P R O V I D I N G S O L U T I O N S, N O T J U S T E Q U I P M E N T

24% higher part-load efficiency saves running costs.

HYDROVAR IncReAseD flexibility AnD control with new generation

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

Safe, reliable, long lasting Lithium Iron Phosphate battery. Next generation capture and release technology. Increased efficiency for greater savings

RANGE. STD Version (Standard): HEE Version (High Energy Efficiency): OPERATION LIMITS. Series LP 46ºC 12ºC 18ºC 5ºC

Bosch BOVA Split System Heat Pump

Bosch BOVA Split System Heat Pump

Transcription:

Tetris W FC/NG Water cooled freecooling chiller 39 634 kw General Tetris W FC/NG is a freecooling chiller for indoor installation that integrates decoupling exchanger, 3-way modulating valve, inverter pump on source side and advanced software to manage the system and remote air cooled exchanger. Configurations Base: unit with a Total Freecooling Temperaure of -2 C HE: unit with a Total Freecooling Temperaure of +1 C Pump and integrated buffer tank available as option Bullet points Plug and play indoor freecooling unit Hybrid freecooling: capability, in the mid seasons, to operate in mixed mode freecoling/chiller Full completely integrated control for managing chiller, freecooling system and remote air cooled exchanger High efficiency in summer mode Two levels of freecooling efficiency and payback time Designed for easy indoor installation Glycol free on user side Wide capacity range

Supplied with dedicated dry cooler optimized for the unit. Indoor freecooling The ultimate freecooling experience

HYBRID FREE COOLING Tetris W FC / NG combines all the advantages of high efficiency water-cooled chiller (Tetris W range) with the hybrid freecooling integrated system STD TFT (100% FC) STD version Nominal cooling capacity [kw] external +1 C 100% FC temperature TFT (100% FC) HE version T STD: 8 C* A Hybrid free Cooling Unit performs full nominal capacity with compressors operating at part load with reduced power consumption. 100% Free Cooling (Winter) Unit performs full nominal capacity only using Dry Cooler fans and with compressors OFF. HE Nominal cooling capacity [kw] Freecooling mode Chiller mode Partial Freecooling -2 C HYBRID FREECOOLING HYBRID FREECOOLING +1 C T ext air T HE: 9 C* A T ext air High partial hybrid freecooling mode NOT ONLY FREECOOLING High efficiency in summer mode Nominal cooling capacity [kw] Thanks to high performance of the chiller side, Tetris W FC/NG ensures high efficiency of the plant during all the year. The product adapts and optimises itself to the seasons, providing a high return all year round. winter Freecooling mode ON summer Partial Freecooling mode spring summer autumn average EER 4,7 * Freecooling mode OFF winter year TETRIS W FC/NG HE 26.4 Example for Stockholm Energy saving=41% Low bills Low carbon emission Total energy consumption [kwh] 25000 20000 15000 10000 5000 Chiller + Freecooling mode Chiller mode only 0-25 -22-19 -16-13 -10-7 -4-1 2 5 8 11 14 17 20 23 26 29 32 External air temperature [C ] Here are a number illustrating the energy savings for Stockholm, in terms of energy consumption, achieved using TETRIS W FC/NG HE, in comparison to a water cooled standard unit, assuming that the cooling need is constant throughout the year. * Evaporator inlet-outlet water temperature 15-10 C; condenser inlet-outlet water temperature 30-35 C (e.g. 30%)

EASY INSTALLATION FULL INTEGRATED CONTROL SYSTEM Advanced built-in control to manage the 3-way modulating valve, inverter driven pump on the source side and the fan speed adjuster of the dry cooler. No need additional cost for controls integration. INVERTER DRIVEN PUMP ON SOURCE SIDE Inverter driven pump on source side as standard: Reduced energy consumption Greater control of condensing temperature in partial freecooling. Tetris W FC / NG provides a lot pof options and pumping configurations to suit every requirements. The footprint is designed for indoor installation (max width below 900 mm). The structure provides also the division in two section for sizes long over 5 meters to allow an easy movement in interior spaces. This means: Less design time Quicker and less cost for installation team Few connections GLYCOL FREE Thanks to the built-in decoupling heat exchanger Tetris W FC/NG is Glycol free on user side. This means: more efficiency on user side with only water the plant doesn t need to be monitored (ethylene glycol is poisonous for humans) Glycol OUT source IN user No Glycol Unit Size 3.2 4.2 5.2 6.2 7.2 8.2 9.2 10.2 12.2 13.2 15.2 17.2 19.2 20.2 24.2 27.2 Cooling Nominal cooling capacity (1),(6) kw 39 45 52 57 66 74 85 103 117 135 150 166 188 206 229 258 EER (1) 4,69 4,66 4,74 4,77 4,72 4,73 4,78 4,79 4,78 4,79 4,82 4,79 4,76 4,67 4,66 4,69 EER (EN 14511-3:2011) (1),(6) 4,10 4,01 4,14 4,18 4,20 4,09 4,17 4,23 4,31 4,26 4,29 4,23 4,24 4,17 4,26 4,23 Basic unit size and weights Lenght mm 1633 1633 1633 1633 1633 1633 1633 1633 3300 3300 3300 3300 3300 3300 3300 3300 Width mm 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 800 Height mm 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 Unit Size 30.3 34.3 40.3 18.4 20.4 24.4 26.4 30.4 34.4 38.4 40.4 48.4 54.4 56.6 60.6 Cooling Nominal cooling capacity (1),(6) kw 328 370 414 169 204 233 263 297 331 377 423 468 527 563 634 EER (1) 4,81 4,84 4,86 4,74 4,72 4,77 4,77 4,78 4,75 4,72 4,73 4,62 4,70 4,73 4,73 EER (EN 14511-3:2011) (1),(6) 4,37 4,35 4,36 4,22 4,33 4,34 4,23 4,39 4,23 4,29 4,23 4,28 4,29 4,28 4,28 Basic unit size and weights Lenght mm 4505 4505 4505 3685 3685 4502 4502 4502 4502 2820 + 2930 3320 + 2930 Width mm 880 880 880 880 880 880 880 880 880 880 880 880 880 880 880 Height mm 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 1880 (1) Evaporator inlet-outlet water temperature 15-10 C; Condenser inlet-outlet water temperature 30-35 C (e.g.30%) (6) Values conform to EN 14511-3:2011 This board reports the feature data of the base and standard versions; for details, refer to the specific documentation.

Hotel Sail City Bremerhaven - Germany Indoor freecooling system -> 2 water cooled chiller + 2 water cooled freecooling chiller Supply -> 1 MW

Blue Box technological product range find out the complete product range on our web site and catalogues Zeta Echos FC > 44 143 kw High efficiency air cooled freecooling chillers. Patented system. Tetris FC series > 97 518 kw High efficiency air cooled modular freecooling chillers. Kappa V Evo FC > 325 1178 kw High efficiency air cooled freecooling chillers. Kappa Rev HEi & XEi > 286 1451 kw Air cooled chillers and heat pumps with Inverter compressor. INVERTER Tetris W FC/NG > 39 634 kw High efficiency water cooled freecooling chillers with integrated hydronic module. Blue Box Group S.r.l. Via Valletta, 5-30010 Cantarana di Cona, (VE) Italy www.bluebox.it - info@bluebox.it Phone +39 0426 921111 - Fax +39 0426 302222