IMPROVED BOTTOM LINE & PV ASSET MANAGEMENT

Similar documents
Improved Bottom Line. SolarEdge Commercial Offering. for Installers & EPCs

IMPROVED BOTTOM LINE & PV ASSET MANAGEMENT. SolarEdge Commercial Offering for Installers & EPCs

IMPROVED BOTTOM LINE & PV ASSET MANAGEMENT

3 Phase Power Systems - Designed for Canada

POWER OPTIMIZERS. SolarEdge Power Optimizer. Module Embedded Solution OPJ300-LV. PV power optimization at the module-level.

SOLAREDGE S STOREDGE SOLUTION

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Sunny Tripower CORE1.

Segen offer the SE2200, SE3000, SE3500, SE3680, SE4000, SE5000 and SE6000 single-phase inverters at great value prices.

MAKING SOLAR SYSTEMS SMARTER

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

SolarEdge Single Phase StorEdge Inverter for Europe, APAC & South Africa

A flexible and efficient residential solar solution. Conext RL single-phase grid-tie inverter

The StorEdge Solution

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Your home and business energy independance. Energy Bundle CA5000TPV-3D

SolarEdge. Distributed Solar Power Harvesting Systems. Company Presentation SolarEdge

MAY 2018 Improving CAPEX and OPEX of PV power plants with high power string inverters Gianluca Pieralli (Regional Sales Manager Lat Am) / Gianluca

MAKING PV SYSTEMS SMARTER. SolarEdge Residential Offering for Installers

MAKING SOLAR SYSTEMS SMARTER

SolarEdge System Overview

MAKING PV SYSTEMS SMARTER

SolarEdge. Distributed Solar Power Harvesting Systems. Company Introduction SolarEdge

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

MAKING PV SYSTEMS SMARTER

SolarEdge. Distributed Solar Power Harvesting Systems SolarEdge

There s a new power in Solar 1500V ultra-high power string inverters for utility-scale PV applications

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops

POWER OPTIMIZIER. (+34) Skype

MAKING PV SYSTEMS SMARTER

MAKING SOLAR SYSTEMS SMARTER PANEL TO GRID SOLUTIONS FROM A GLOBAL LEADER IN SOLAR TECHNOLOGY

SUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN

RE10 tenksolar System Overview

Greater reliability and flexibility for large solar installations. Conext Core XC-NA series central inverters

ABB central inverters PVS to 1000 kw

SolarEdge Solution - Making PV Panels Smarter GGS. Greener Gas Scotland Renewables & Heating

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

The StorEdge Solution. Enabling Energy Independence

The microinverter The latest in solar technology

ABB central inverters PVS to 1000 kw

MAKING PV SYSTEMS SMARTER

Microgrid solutions Delivering resilient power anywhere at any time

PLUG-AND-PLAY ENERGY STORAGE SOLUTION

MAKING PV SYSTEMS SMARTER

OPTIMIZING COMMERCIAL SOLAR

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

StorEdge Solar and Energy Storage System Review

SolarMax MT A series A reliable solution for commercial PV applications

SAMPLE PERMIT APPLICATION PACKAGE

/ The personal storage solution for 24H sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Trinasmart SEUK Oct Daniel E. Mamat Product Management

SolarMax MT series The all-rounder for trade and industry

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE. / Perfect Welding / Solar Energy / Perfect Charging

SolarMax MT series. The power pack for maximum yields.

MAX310 BEESMART SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY Apparent Power Control (APC)

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Power Conversion System The Best Technology for your photovoltaic and storage system

FusionSolar Smart PV Solution. Exceed your profit targets through Digitalization Networking Higher Yields. FusionSolar

Pre-announcement. Transformerless Solar Inverters

Creating technology to keep the sky blue... MAVI SOLAR PHOTOVOLTAIC ENERGY STORAGE SYSTEM

Catch Eco Range : Technical Specification Sheet

ABB central inverters ULTRA-750/1100/ kW to 1560kW

THREE-PHASE. FRONIUS ENERGY PACKAGE / The personal storage solution for 24 hours of sun. EFFICIENT FLEXIBLE REVOLUTIONARY

TerraSAS High-Performance 600V PV simulator

ABB central inverters PVS to 2000 kva

OUR PARTNERS. More: Please note: All product illustrations in this brochure may differ from the original.

X-SERIES SOLAR PANELS

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

TripleLynx Inverter Range MAKING MODERN LIVING POSSIBLE. The benchmark solar inverter from Danfoss 3 phase Transformerless 8, 10, 12.

SPEEDFAX TM 2011 Renewable Energy Products Contents

Enphase M215 PRODUCTIVE SIMPLE RELIABLE. Enphase Microinverters

The intelligent, reliable cloud-connected inverter for utility-scale renewable power

ABB central inverters PVS to 2091 kva

HYBRID POWER FOR TELECOM SITES

Pika Energy Island Made in America

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

off-grid Solutions Security of supply Basics: Off-grid energy supply

/ The personal storage solution for 24H Sun. / Dynamic Peak Manager. / Smart Grid Ready THREE-PHASE

Re-defining the utility-scale inverter

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

Micro-Inverter. Corporate and Product Presentation. AEconversion GmbH & Co. KG. Micro vs. String. Product Details. USPs. Market Overview.

MORNINGSTAR PRODUCT TRAINING

MAX310 BEESMART SOLAR MICRO INVERTER TYPE 260. Apparent Power Control (APC) SOLAR PV MODULES UP TO 310 W peak

ABB - DMPC PG Solar, Nov 2016 ABB: a leading company in solar The most comprehensive value proposition

FRONIUS SNAPINVERTERS SMARTER, LIGHTER, MORE FLEXIBLE

BROCHURE. End-to-end microgrid solutions From consulting and advisory services to design and implementation

Residential Energy Storage System SH5K PV ESS

Ginlong Solis US 4G PV Single-Phase String Inverters; 6 kw through 10 kw. Terence Parker Ginlong Technologies


Module-Integrated Power Electronics for Solar Photovoltaics. Robert Pilawa-Podgurski Power Affiliates Program 33rd Annual Review Friday, May 4th 2012

AMS ValveLink SNAP-ON Applications

SolarMax P series The power package for residential solar plants

Transcription:

IMPROVED BOTTOM LINE & PV ASSET MANAGEMENT SolarEdge Commercial Offering for Installers & EPCs

Content 04 SolarEdge Fact Sheet 06 Moving Forward to DC Optimised Inverters 08 PV Asset Management with Panel-Level Monitoring 14 Maximum Energy Yield in Commercial Installations 16 Future Compatibility & Warranty 18 A Higher Lifetime Value 20 Commercial System Diagram 22 300kWp Rooftop System Comparison 24 300kWp Electrical Diagram Comparison 26 1MWp Ground Mount System Comparison 28 1MWp Electrical Diagram Comparison 30 Product Datasheets 30 SE10K-27.6K Three Phase Inverter 32 SolarEdge Power Optimiser P600-800 Panel Add-on Solution 34 SolarEdge Control & Communication Gateway 36 Environmental Sensors 38 Analog Sensor Connections 40 Comprehensive Service Suite 1.63MW SolarEdge system, The Netherlands Installed by AliusEnergy 2 SolarEdge Commercial Offering www.solaredge.com 3

SolarEdge Fact Sheet About Us In 2006, SolarEdge invented an intelligent inverter solution that has changed the way power is harvested and managed in PV systems. SolarEdge provides panel-level electronics for solar power harvesting and monitoring for residential, commercial, and utility-scale solar PV installations. The SolarEdge DC optimised inverter system maximises power generation at the PV panel level while lowering the cost of energy produced by the solar PV system. Vision > As a leading provider of intelligent inverter solutions for the PV industry, our vision is to enable every solar panel to be individually managed by DC-DC panel-level electronics > Our goal is to accelerate the pace toward grid parity and make clean, renewable solar energy affordable and widespread Bankability > SolarEdge has been audited and approved by major banks and financial institutions for projects and funds worldwide > Publicly traded on the NASDAQ under the SEDG symbol Global Outreach > Systems installed in 120 countries > Sales via leading integrators and distributors > Follow the sun call centers > Local teams of sales, service, marketing, and training experts > Global manufacturing with tier 1 electronic manufacturing service companies > Received nearly 30 awards, from prestigious organisations ranging from Red Herring to Frost & Sullivan Business Figures > 22,700,000 power optimisers and 950,000 inverters shipped worldwide > Monitoring platform continuously tracks over 560,000 PV installations Units Shipped (M) 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Power Optimisers Shipped (Cumulative) 2013 2014 2015 2016 2017 (Calendar Years) Corporate Social Responsibility > As a global leader in renewable energy solutions, SolarEdge is deeply committed to promoting a greener world > SolarEdge is in full compliance with international standards on quality and control, ethical conduct and environmental protection 117 awarded patents and 150 additional patent applications Product Reliability > Long product warranties: 25-year power optimiser warranty and 12-year inverter warranty, extendable to 20 or 25 years > SolarEdge products and components undergo rigorous testing, and have been evaluated in accelerated life chambers > Reliability strategy includes proprietary application specific ICs (ASIC) 4 SolarEdge Commercial Offering www.solaredge.com 5

Moving Forward to DC Optimised Inverters Significance of Inverter Selection Inverter selection is key for the lifetime planning and performance of commercial PV systems. While inverters may only account for ~10% of the system cost, they: 1. Influence ~30% of system cost (EBoS, inverter, labor) 2. Manage 100% of system production 3. Control O&M expenses by enabling PV asset management Reduced BoS Costs Up to 15kW per string allows for more panels per string. This leads to fewer strings per inverter and therefore less wiring, combiner boxes, and fuses. This reduces BoS costs by up to 50%. Traditional Inverter SolarEdge DC Optimised Inverter Lifetime Revenue More Panels With panel-level power optimisation and maximum design flexibility, more panels can be installed on the roof, enabling a shorter project payback period. Traditional inverter 149.5 kw DC SolarEdge 200 kw DC 34% added power More Energy The panel-level MPPT eliminates losses to maximise power from each individual panel, offering more energy production from the PV system. This technology future proofs the system against potential risks that could cause decreased lifetime energy production. System Lifetime O&M Costs Future Compatibility & Warranty Low-cost inverter replacement (~40% less than traditional inverters), long inverter warranty, free lifetime monitoring, and the ability to install different panel power classes/brands in the same string, decrease future costs. Cost-Saving Maintenance & Higher System Uptime Free panel-level performance monitoring & remote maintenance for system lifetime lead to more effective and efficient O&M by decreasing trips to sites, reducing the amount of time spent on site, and increasing system uptime. 1MW SolarEdge system, Hoffenheim, Germany Installed by Wircon Enhanced Safety The DC disconnect is designed to automatically drop DC voltage, as well as current from all DC string cables, whenever inverter or grid power is shut down. The voltage of each panel is reduced to 1V. SolarEdge inverters comply with the UL1699B arc detection standard designed to mitigate the effects of some arc faults that may pose a risk of fire. 6 SolarEdge Commercial Offering www.solaredge.com 7

PV Asset Management with Panel-Level Monitoring As a strategic O&M tool for optimum plant operation and PV asset management, the SolarEdge cloud-based monitoring platform increases system uptime. As equipment prices drop and system sizes trend upward, PV projects are increasingly seen as secure long-term investment opportunities. Like any financial asset, PV systems must be monitored and managed to realise their full potential. Traditional inverters offer limited information, such as string-level or system-level monitoring that can indicate underperformance of the array, but little else. It then becomes costly and time consuming to send skilled technicians to perform on site troubleshooting on inverters operating under load and on DC lines at nearly 1000V. They must connect expensive equipment to the arrays in an effort to sift through the tea leaves of complex IV trace curves to detect issues. The SolarEdge DC optimised inverter solution offers advanced PV monitoring and asset management through its cloud-based monitoring platform. Power optimisers constantly track MPP and report high-resolution data on panel performance. SolarEdge Saving 15%-25% O&M Cost Overhead Monitoring & Reporting The SolarEdge monitoring platform transforms O&M from a manual, resource-intensive process to an automated, at-a-glance service. The solution delivers panel-level insights and ensures that a plant is performing to the best of its ability at all times. Corrective Maintenance * Exclusive of panel cleaning Preventive Maintenance 1MW SolarEdge system, Florida, United States Developed and installed by Region Solar & Sol Integrators 8 SolarEdge Commercial Offering www.solaredge.com 9

PV Asset Management with Panel-Level Monitoring (cont.) SolarEdge's Monitoring Platform Features: 1. Real-time remote monitoring at the panel, string, and system levels 3. Pinpointed and automatic alerts for immediate fault detection, accurate maintenance, and rapid response. The alerts show the specific fault location, fault description, and fault status. Energy threshold alerts can be set to detect underperforming panels. Custom settings available for time of day and offset from sunrise and sunset. The logical layout displays the electrical connectivity between panels, strings and inverter The hierarchy layout displays grouping of components per inverter 2. Comprehensive analytics tracking and reports of energy yield, system uptime, performance ratio, and financial performance 4. The time-of-use feature allows system owners to define peak and off-peak rates in order to track expected PV revenue. This may be used as an indication of the systems ROI. Dashboard - Energy production is displayed with a weekly, monthly and yearly resolution Performance Ratio - Analyse and track the system's performance ratio 10 SolarEdge Commercial Offering www.solaredge.com 11

PV Asset Management with Panel-Level Monitoring (cont.) 5. Accurate and remote troubleshooting for fast and efficient resolution with minimal and shortened onsite visits. Examples of identifying underperforming panels: Bypass Diode Failure Soiling Before cleaning After cleaning It is easy to identify the bypass diode failure with the panel-level voltage graphs. The faulty panel outputs at only 2/3 of the voltage (5/6 in this case of power optimiser connected to two panels). 6. The consumption monitoring feature shows data about electricity consumption, PV production, and self-consumption. This feature is integrated into all SolarEdge inverters and requires only a connection of a SolarEdge Modbus Meter. Potential Induced Degradation (PID) Looking at the panels within one string, it is possible to see the power degradation increasing towards the negative pole. No need to send technicians to the roof panel voltage is measured remotely 12 SolarEdge Commercial Offering www.solaredge.com 13

Maximum Energy Yield in Commercial Installations Unavoidable in commercial installations, panel-level mismatch occurs when panels in a string have different Maximum Power Points (MPPs). Arising from a variety of sources, the mismatch decreases the energy yield of the entire string. Impp Traditional String Inverter 247W 250W 242W 248W Impp Impp Impp Impp SolarEdge DC Optimised Inverter Solution 247W 250W 242W 248W Impp Impp Impp Examples of power mismatch in commercial installations: Manufacturing Tolerance Mismatch The panel manufacturer-warranted output power range may vary greatly. A standard deviation of 3% is sufficient to result in ~2% energy loss. Guaranteed power output from panel manufacturers 0~+3% Vmpp Vmpp Vmpp Vmpp Vmpp Vmpp Vmpp Vmpp Soiling & Shading Panel soiling, from dirt or bird droppings, contributes to mismatch between panels and strings. While there may be no obstructions during site installation, throughout a system s lifetime, a tree may grow or a structure may be erected that creates uneven shading. > MPPT per string - all panels operate at same current, regardless of their individual MPP > Weak panels reduce the performance of all panels in the string or are bypassed > Power losses due to panel mismatch > MPPT per panel - current & voltage adjusted per panel > Maximum power produced and tracked from each panel individually > 2%-10% more energy from the PV system The SolarEdge DC optimised inverter solution mitigates power losses caused by panel mismatch for maximum power generation from each panel. With SolarEdge, strong panels are not affected by the weaker ones. Soiling Bird droppings Leaves Uneven Panel Ageing Panel performance can degrade up to 20% over 20 years, however, each panel ages at a different rate, which causes ageing mismatch. Worst panel Average Best panel Batch Source: A. Skoczek et. al., The results of performance measurements of field-aged c-si photovoltaic modules, Prog. Photovolt: Res. Appl. 2009; 17:227 240 14 SolarEdge Commercial Offering www.solaredge.com 15

Future Compatibility & Warranty As part of PV asset management planning, it is important to account for future costs that can impact the return on investment of a PV system. The SolarEdge DC optimised inverter solution effectively minimises these potential costs. Forward compatibility eliminates expensive stock of spare panel inventory. > Replacement: SolarEdge allows panels of different power classes and brands in the same string. > Expansion: New power optimisers can be utilised in the same string with older models. SolarEdge offers 25-year power optimiser warranty, 12-year inverter warranty, and free monitoring for 25 years. SolarEdge offers extended warranties at attractive prices. Power Optimisers 600W - 800W Commercial Inverters 10kVA - 100kVA Cloud-based Monitoring Platform SolarEdge provides low-cost inverter replacement out of warranty > ~40% less than traditional inverters Products are certified for ammonia resistance - suitable for agricultural areas AMMONIA RESISTANT 2.02MW SolarEdge system, Denmark 16 SolarEdge Commercial Offering www.solaredge.com 17

A Higher Lifetime Value The SolarEdge DC optimised inverter solution offers a better LCOE for a system s lifetime by maximising yield and reducing costs. The SolarEdge DC optimised inverter solution maximises power generation at the individual panel level, which leads to a higher lifetime revenue from PV systems. While the initial cost of the SolarEdge solution is generally slightly higher than the equivalent traditional inverter system, the total installation cost as well as the lifetime maintenance cost, is lower. This makes the SolarEdge solution more economically attractive. Lifetime PV System Cost and Revenue $ Lifetime revenue BoS cost Inverter replacement cost Lifetime O&M cost System lifetime Value Traditional inverter SolarEdge solution 1.3MW SolarEdge system, Arizona, USA 18 SolarEdge Commercial Offering www.solaredge.com 19

Commercial System Diagram The SolarEdge solution consists of inverters, power optimisers, and a cloud-based monitoring platform. The technology provides superior power harvesting and panel management by connecting power optimisers at the panel level. The ability to connect two panels to one optimiser, combined with DC to AC conversion and grid interaction being centralised at a simplified PV inverter maintains a competitive cost structure. Cloud-based Monitoring Platform Full visibility of system performance Remote troubleshooting Access via browser or any Android, ios smart phone or tablet Communication with the power optimisers over existing DC power lines (PLC) Control & Communication Gateway Connection of multiple environmental sensors to analyse system performance Environmental Sensors Connection of environmental sensors to calculate site performance ratio and measure environmental conditions P600 P800 2-to-1 Power Optimiser Configuration 10kVA-100kVA Inverter Panel-level MPPT - no mismatch power losses Strings of uneven lengths, panels on multiple azimuths & tilts SafeDC - designed for automatic panel-level safety shutdown Specifically designed to work with power optimisers Superior efficiency Easy installation, including 2-person install for large capacity models Mobile configuration of up to 3.2MW in one go Built-in communication hardware, with optional GSM cellular modem Integrated DC Safety Unit Embedded feed-in limitation * Inverters >27.6kVA are expected to be available in Q3 2018 Grid Interaction Supports power control, e.g. zero export limitation, local and remote active/reactive power control, inverter AC relay control for secondary grid protection; low voltage and frequency ride through. 20 SolarEdge Commercial Offering www.solaredge.com 21

300kW Rooftop System Comparison Comparison of a 300kWp SolarEdge system to an identical system with a traditional string inverter The system, in Amsterdam, The Netherlands, comprises 1,000 300Wp panels. One system was designed with 9 SE27.6K SolarEdge inverters and power optimisers. The second system was designed with 9 27.6kW traditional string inverters. Energy Comparison PVsyst was used to simulate the yield of both systems in year 1 and year 20. The SolarEdge advantage is growing with time due to uneven panel aging which increases mismatch between panels. Traditional String Inverter SolarEdge System SolarEdge Advantage PVsyst year 1 yield (MWh) 272.3 279.1 2.5% PVsyst year 20 yield (MWh) 242.9 257.2 5.9% BoS comparison Traditional String Inverter SolarEdge DC Optimised Inverter DC power (kw) 300 300 AC power (kw) 248.4 248.4 Panels (300W, 72-cell) 1,000 1,000 Inverters 9 9 No. of strings 54 27 Panels per string 18/19 36/38 DC cable CU 1 6mm 2 (m) 6,542 2,317 MC4 connectors (1 pair) 108 54 Datalogger 1 - BoS cost 100% 31% BoS cost saving* 1.15 c/w * Estimated saving on BoS components based on typical market prices in Cabling Comparison Traditional Inverter Cabling Diagram Total of 54 strings SolarEdge Cabling Diagram Total of 27 strings Included DC cables Additional DC cables 22 SolarEdge Commercial Offering www.solaredge.com 23

300kWp Rooftop System Electrical Diagram Comparison Traditional String Inverter System SolarEdge DC Optimised Inverter Solution 24 SolarEdge Commercial Offering www.solaredge.com 25

1MWp Ground Mount System Comparison Comparison of a 1MWp SolarEdge solution to an identical system with a traditional string inverter The system, in Munich, Germany, comprises 4,050 260Wp panels. One system was designed with 33 SE27.6K SolarEdge inverters and power optimisers. The second system was designed with 18 50kW traditional string inverters. Energy Comparison PVsyst was used to simulate the yield of both systems in year 1 and year 20. The SolarEdge advantage is growing with time due to uneven panel aging which increases mismatch between panels. Traditional String Inverter SolarEdge System SolarEdge Advantage PVsyst year 1 yield (MWh) 1,159 1,182 2% PVsyst year 20 yield (MWh) 1,036 1,090 5.2% BoS comparison Traditional String Inverter SolarEdge DC Optimised Inverter DC power (kw) 1,053 1,053 AC power (kw) 900 910.8 Panels (300W, 72-cell) 4,050 4,050 Inverters 18 33 No. of strings 180 99 Panels per string 22/23 40/42 DC cable CU 1 6mm 2 (m) 7,347 2,561 MC4 connectors (1 pair) 360 198 AC cable NA2XY 4 35mm 2 (m) - 2,459 AC cable NA2XY 4 70mm 2 (m) 1,349 - Datalogger 1 - BoS cost 100% 62% BoS cost saving* 0.4 c/w * Estimated saving on BoS components based on typical market prices in Cabling Comparison Traditional Inverter Cabling Diagram Total of 180 strings SolarEdge Cabling Diagram Total of 99 strings Included DC cables Additional DC cables 26 SolarEdge Commercial Offering www.solaredge.com 27

1MWp Ground Mount System Electrical Diagram Comparison Traditional String Inverter System SolarEdge DC Optimised Inverter Solution 28 SolarEdge Commercial Offering www.solaredge.com 29

SE10K-27.6K Three Phase Inverter Datasheet Specifically designed to work with power optimisers Superior efficiency (98%) Small, lightest in its class, and easy to install Internet connection through Ethernet or Wireless (Wi-Fi, ZigBee Gateway, Cellular) IP65 Outdoor and indoor installation Fixed voltage inverter Integrated DC Safety Unit - 2-pole Mechanical DC disconnect - Optional DC fuses (for SE25K & SE27.6K models only) Mobile configuration of up to 3.2MW in one go for easy and fast commissioning. Expected availability Q2 2018. SE10K (2) SE12.5K SE15K SE16K SE17K SE25K SE27.6K OUTPUT Rated AC Power Output 10000 12500 15000 16000 17000 24950 27600 VA Maximum AC Power Output 10000 12500 15000 16000 17000 24950 27600 VA AC Output Voltage - Line to Line / Line to Neutral (Nominal) 400 / 230 Vac AC Output Voltage - Line to Neutral Range 184-264.5 Vac AC Frequency 50/60 ± 5 Hz Maximum Continuous Output Current (per Phase) 16 20 23 25.5 26 38 40 A Grids Supported - Three Phase 3 / N / PE (WYE with Neutral); 230 / 400 V Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds Yes SE10K (2) SE12.5K SE15K SE16K SE17K SE25K SE27.6K INPUT Maximum DC Power (Panel STC) 13500 16850 20250 21600 22950 33750 37250 W Transformer-less, Ungrounded Yes Nominal DC Input Voltage DC to Gnd 375 Maximum Input Voltage DC to Gnd 415 Nominal DC Input Voltage DC+ to DC- 750 Vdc Maximum Input Voltage DC+ to DC- 830 Vdc Maximum Input Current 16.5 21 22 23 23 37 40 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 700kΩ Sensitivity 350kΩ Sensitivity (3) Maximum Inverter Efficiency 98 98.3 % European Weighted Efficiency 97.6 97.7 97.6 97.7 97.7 98 98 % Nighttime Power Consumption < 2.5 < 4 W ADDITIONAL FEATURES Supported Communication Interfaces (4) RS485, Ethernet, ZigBee (optional), Wi-Fi (optional), Cellular (optional) DC SAFETY UNIT 2-pole Disconnection 1000V / 23A 1000V / 40A STANDARD COMPLIANCE Safety IEC62109, AS/NZS3100 Grid Connection Standards AS/NZS4777:2015 Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 RoHS Yes INSTALLATION SPECIFICATIONS AC output conduit size / Wire 19mm minimum / 3-13 mm 2 cross section DC input conduit size / Wire cross section Dimensions with Safety Unit (HxWxD) 775 x 315 x 191 19mm minimum / 3-13 mm 2 775 x 315 x 260 mm Weight 24.9 36.2 48 kg Operating Temperature Range -20 - +60 (5) C Cooling Internal Fan Fan (user replaceable) Noise < 40 < 50 < 55 dba Protection Rating IP65 - Outdoor and Indoor Bracket Mounted (Bracket Provided) (1) These specifications apply only to inverters with part numbers SExxK-AU000NNU2 (2) These specifications apply only to inverters with part number SE10K-AU002NNU2 (3) Where permitted by local regulations (4) Refer to Datasheets -> Communications category in Downloads page for specifications of optional communication options: http://www.solaredge.com/groups/support/downloads (5) For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf 30 SolarEdge Commercial Offering www.solaredge.com 31

SolarEdge Power Optimiser P600-800 Panel Add-on Solution The most cost-effective solution for panel-level optimisation in commercial installations Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Balance of System costs reduction; 50% less cables, fuses and combiner boxes, over 2x longer string lengths possible Fast installation with a single bolt Next generation maintenance with panel-level monitoring Panel-level voltage shutdown for installer and firefighter safety Use with two PV panels connected in series or in parallel Optimiser model (typical panel compatibility) P600 (for 2 x 60-cell PV panels) P700 (for 2 x 72-cell PV panels) P800p (for parallel connection of 2x 96-cell 5 PV panels) P800s (for series connection of 2x high power or bi-facial panels) INPUT Rated Input DC Power (1) 600 730 800 W Absolute Maximum Input Voltage (Voc at lowest temperature) 96 125 83 120 Vdc MPPT Operating Range 12.5-80 12.5-105 12.5-83 12.5-105 Vdc Maximum Short Circuit Current (Isc) 10.25 14 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMISER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 18 Adc Maximum Output Voltage 85 Vdc Optimiser model (typical panel compatibility) (1) Rated STC power of the panel. Panel of up to +5% power tolerance allowed. (2) For other connector types please contact SolarEdge. (3) For ambient temperature above +70 C / +158 F power de-rating is applied. Refer to Power Optimisers Temperature De-Rating Application Note for more details. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER (4)(5) P600 (for 2 x 60-cell PV panels) P700 (for 2 x 72-cell PV panels) THREE PHASE SE15K AND LARGER P800p (for parallel connection of 2x 96-cell 5 PV panels) THREE PHASE SE16K AND LARGER P800s (for series connection of 2x high power or bi-facial panels) OUTPUT DURING STANDBY (POWER OPTIMISER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 ± 0.1 Vdc Optimiser STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety) RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Compatible SolarEdge Inverters Three phase Three phase inverters inverters SE16K & larger SE15K & larger Maximum Allowed System Voltage 1000 Vdc Dimensions (W x L x H) 128 x 152 x 43 128 x 152 x 50 128 x 158 x 59 128 x 152 x 59 mm Weight (including cables) 834 933 1019 1064 gr Input Connector (2) MC4 MC4 (5) MC4 Output Connector MC4 Output Wire Length 1.8 2.1 1.8 2.1 m Operating Temperature Range (3) -40 - +85 C Protection Rating IP68 / NEMA6P Relative Humidity 0-100 % Compatible Power Optimisers P600 P600, P700 P800 Minimum String Length Power Optimisers 13 12 PV Panel 26 24 Maximum String Length Power Optimisers 30 PV Panel 60 Maximum Power per String 11250 (6) 13500 W Parallel Strings of Different Lengths or Orientations Yes (4) P600 and P700 can be mixed in one string. It is not allowed to mix P600/P700/P800 with P300/P370/P500/P404/P405/P505 in one string. (5) In a case of odd number of PV panels in one string it is allowed to install one P600/P700/P800 power optimiser connected to one PV panel. When connecting a single panel to the P800p seal the unused input connectors with the supplied pair of seals. (6) For SE27.6K: It is allowed to install up to 13,500W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W; inverter max DC power: 37,250W. 32 SolarEdge Commercial Offering www.solaredge.com 33

SolarEdge Control & Communication Gateway All-in-one communication gateway Environmental sensors support Power reduction interface & MV grid control Modbus meter reader Easy installation - DIN rail and wall mount SE1000-CCG-G POWER Power Supply - Wall Mount Included, 100-240VAC, EU/UK/US/AU interchangeable, 2-pin plug Supply Voltage 9-14 VDC Connector Type Terminal block Power Consumption <2 W ANALOG SENSOR INPUT Number of Inputs 3 Range Accuracy Resolution Input 1 0-30mV or 0-2V Input 2 0-2V or 0-10V +/- 1% f.s 10 bit Input 3-20mA 20mA COMMUNICATION INTERFACES Ethernet Interface SE1000-CCG-G 10/100-BaseT Wireless Connections ZigBee card ( * ) Power Reduction Interface RS232 Interface SUPPORTED RS485 DEVICES (A) SolarEdge Devices Export Inverter Data Electricity Meters Revenue Meters 4 control pins, 5V, GND For local connection Yes Yes Yes (also supports integration with third-party meters, such as for accurate export limitation readings) Export Data to Non-SolarEdge Logger Yes ENVIRONMENTAL Operating Temperatures -20 to 60 C Protection Rating IP20 Indoor MECHANICAL Mounting Type DIN Rail / Wall mount Dimensions (L W H) 161.6 90 62 mm Weight 0.5 kg STANDARD COMPLIANCE Safety UL60950-1, IEC-60950-1 EMC FCC Part 15 class B, IEC61000-6-2, IEC61000-6-3 (a) for supported protocols and devices, see link: www.solaredge.com/files/pdfs/se-gateway-supported-devices (*) sold separately - see individual product specs for supported locations Yes 34 SolarEdge Commercial Offering www.solaredge.com 35

Environmental Sensors Environmental Monitoring of a SolarEdge System Connect environmental sensors to the SolarEdge inverter Calculate site performance ratio Irradiance, temperature, and wind measurements Direct Irradiance SE1000-SEN-IRR-S1 Ambient Temperature SE1000-SEN-TAMB-S2 Panel Temperature SE1000-SEN-TMOD-S2 Wind Velocity SE1000-SEN-WIND-S1 INSTALLATION SPECIFICATIONS Control and Communication Gateway Needed (sold separately; SE1000-CCG-G) 154 86 40 / 64 58 34 / 64 58 34 / 165 105 105 / mm / Dimensions 6 3.5 1.5 2.5 2.3 1.3 2.5 2.3 1.3 6.5 4.2 4.2 in Weight 340 / 0.75 350 / 0.77 350 / 0.77 750 / 1.65 gm / lb Enclosure type Operating Temperature Powder-coated aluminum -20 to 70 / -4 to 155 Pulver Coated Aluminium -40 to 80 / -40 to 176 Pulver Coated Aluminium -40 to 80 / -40 to 176 Housing - Aluminum (AlMgSi1) Cup star - Synthetic, with fibre glass (PC-GF10) Bottom - Synthetic (POM H2320) Protection Rating IP65 IP67 IP67 IP55 Units 0 to 70 / 32 to 155 C / F The warranty and service for the sensors is provided directly by Ingenieurbüro Mencke & Tegtmeyer GmbH; for more details, please see http://www.imt-solar.com/products.html Direct Irradiance SE1000-SEN-IRR-S1 Ambient Temperature SE1000-SEN-TAMB-S2 Panel Temperature SE1000-SEN-TMOD-S2 Wind Velocity SE1000-SEN-WIND-S1 OUTPUT Electrical output range 0-1.4V 0-10V 4-20mA 4-20mA MEASUREMENT Range 0-1400 W/m 2-40 to 90 C / -40 to 194 F -40 to 90 C / -40 to 194 F Accuracy ±5% 1% of full scale 1% of full scale 0-50 m/s ±0.5 m/s or ±3% of measuring value Units 36 SolarEdge Commercial Offering www.solaredge.com 37

Analog Sensor Connections With the connection of sensors to the SolarEdge Control and Communication Gateway (CCG), PV system owners can monitor the site s irradiance, temperature and wind velocity. This also enables the SolarEdge monitoring server to calculate and display the site performance ratio (PR), calculated based on the sensor readings. 38 SolarEdge Commercial Offering www.solaredge.com 39

Comprehensive Service Suite SolarEdge supports you throughout your PV project life cycle. We provide the tools and services to help you grow your business with us. Project Design and Pre-Sale Our dedicated tools and engineering services help you close deals. Project Design & Pre-Sale Tailor-made design optimisation by SolarEdge pre-sale engineers Training and tools help your sales team convey the added value of the SolarEdge solution Project Execution LCOE and ROI analysis PV simulation and Comparative system analysis Operation & Maintenance 40 SolarEdge Commercial Offering www.solaredge.com 41

Comprehensive Service Suite (Cont.) Project Execution Operation & Maintenance Our advanced tools and features will assist you to easily and smoothly execute projects. Our advanced monitoring platform allows you to guarantee system availability and high performance ratio for system lifetime. Performance monitoring Project design validation prior to installation Hands-on installation training by local field engineers Installation validation checklist Fleet management Pre-scheduled performance and status reports of multiple sites Fault detection DC safety protecting installers from high DC voltage Easy and flexible string layout Pinpointed automatic alerts Inter-site and multi-site comparisons Executive reporting Remote and on-site installation support by local service teams Inverter and panel-level fault identification Remote troubleshooting tools Service Remote operations to commission and activate the installation Site specific automated production reports Automatic commissioning report Rapid RMA process 42 SolarEdge Commercial Offering Follow the sun call center www.solaredge.com 43

SolarEdge invented an intelligent inverter that has changed the way power is harvested and managed in PV systems. The SolarEdge DC optimised inverter maximises power generation at the individual PV panel-level while lowering the cost of energy produced by the PV system. Addressing a broad range of solar market segments, from residential to commercial and largescale solar, the SolarEdge DC optimised inverter solution includes PV inverters, power optimisers, and cloud-based monitoring. By connecting power optimisers to each panel, the system enables superior power harvesting and panel management. System costs remain competitive by centralising the DC-AC inversion and grid interaction at a simplified PV inverter. Enhanced PV asset management including reduced O&M costs are enabled through panel-level monitoring and remote troubleshooting. Another benefit is the automatic DC shutdown, for installer, maintenance personnel, and firefighter safety, through the SafeDC mechanism. Website Email www.solaredge.com australia-info@solaredge.com SolarEdge @SolarEdgePV SolarEdgePV SolarEdge SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2018/V01/ENG AUS. Subject to change without notice. This document includes estimates of various parameters of the compared solar systems, including annual A/C energy production, performance ratio and shading loss based on PVsyst computer-simulated results for installations using our and competing systems. While we are not aware of any reason to believe these estimates and comparisons are materially inaccurate or misleading, they are inherently uncertain and the projected results are not guaranteed. Actual results will vary depending on a number of factors, including actual field conditions, quality of installment and other variances from the assumptions underlying the estimates. Although care has been taken to ensure the accuracy, completeness and reliability of the estimates and comparisons presented, SolarEdge assumes no responsibility for these. MORE SPECIFICALLY, IN NO EVENT SHALL SOLAREDGE BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL OR INCIDENTAL LOSSES OR DAMAGES RESULTING FROM OR ARISING OUT OF USE OF OR RELIANCE ON THE ESTIMATES AND COMPARISONS PRESENTED. Cautionary Note Regarding Market Data and Industry Forecasts: This brochure may contain market data and industry forecasts from certain third-party sources. This information is based on industry surveys and the preparer s expertise in the industry and there can be no assurance that any such market data is accurate or that any such industry forecasts will be achieved. Although we have not independently verified the accuracy of such market data and industry forecasts, we believe that the market data is reliable and that the industry forecasts are reasonable.