IN-LINE HYDRAULIC FLOW TESTER

Similar documents
TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Collision Repair Set. Form No No. 1517A 4-Ton Set. No. 1519A 10-Ton Set. Parts List & Operating Instructions for: 1519A. Part No. Item No.

Operating instructions Form no safety definitions

MANUAL PALLET VALVE # Manifold Mount Outlet Port # /16-20 UNF SAE-4 Outlet Port # /4 NPT Outlet Port Max. Capacity: 5,000 PSI

OPERATOR S MANUAL Model 60010

Air / Hydraulic Pump

Hydraulic Hub Grappler Kit

IN-LINE HYDRAULIC FLOW TESTER 75 GPM, 300 I/min.

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

Rear Suspension Bushing Remover/Installer

Air / Hydraulic Pump Instructions. CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine.

IN-LINE HYDRAULIC FLOW TESTER

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

Explanation of Safety Signal Words

Under Axle Jack Max. Capacity: 25 Tons

IN-LINE HYDRAULIC FLOW TESTER 75 GPM, 300 I/min.

Air / Hydraulic Floor Service Jack

KLW4000D Multi-Port Power Pack

Instruction Manual. Double Acting Hydraulic, Hollow Piston Cylinders RHD Series. Maximum Operating Pressure 700 bar

Instruction Manual. Maximum Operating Pressure 510 bar

MODEL 890 / 892 POWER POST 10 TON CAPACITY

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

SERIES OPERATION AND MAINTENANCE MANUAL

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

Analog Hydraulic Testers

Portable Two-Stage Under Axle Jack Max. Capacity: First Stage: 27.5 Tons Second Stage: 11 Tons. Safety Precautions

QS-2200A ELECTRIC/HYDRAULIC LUBRICATION UNIT OPERATING MANUAL CONTENTS:

Racing Jack Max. Capacity: 3,000 lbs. (1,361 kg)

Air / Hydraulic Floor Service Jack

Instruction Manual. Single Acting, Pancake, Locking Collar Hydraulic Cylinders RPLC Series. Maximum Operating Pressure 700 bar

Operating Instructions for: PE10 Series. Electric-Powered 10 Series Hydraulic Pump SPX

Instruction Manual. Single Acting, High Tonnage, Low Height Cylinders RSH Series. Maximum Operating Pressure 700 bar

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

Forklift Jack. Scissors Max. Capacity: 4 ton Scissors Low Height: 2-5/32 in. (55 mm) Scissors High Height: 17-29/32 in. (455 mm)

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

Hydraulic Pump Troubleshooting P & BDP Series Models

High Lift Transmission Jack

High Lift Transmission Jack

Instruction Manual. Single Acting, Aluminium, Locking Collar Hydraulic Cylinders ARSLC Series. Maximum Operating Pressure 700 bar

Hydraulic PTO Flow Device

Instruction Manual. Maximum Operating Pressure 700 bar

Motorcycle/ATV Lift. Max. Capacity: 1,500 lbs. Parts List

FTMP-8 AND FTMP-12 Midget Puller Units

Fuel System Diagnosis

HYDRAULIC PUMP BATTERY POWERED. Operating Instructions for: SPX Hydraulic Technologies th Street Rockford, IL USA powerteam.

Hydraulic Immediate Need Power Pack

PE39 Series Compact Torque Wrench Pump

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

Service Jack. Form No Parts List & Operating Instructions 1510B. Max. Capacity: 5 and 10 Tons. 1 of 3. Sheet No. Issue Date: Rev.

Troubleshooting the Transmission Hydraulic System

User Manual for: PE30 Series. Electric-Powered 30 Series Hydraulic Pump SPX


MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

User Manual for: PE8 Series PE17 Series. Electric-Powered 8 & 17 Series Two-Stage Hydraulic Pump SPX

Air / Hydraulic Under Axle Jack

IBT Series Square Drive Torque Wrenches

Troubleshooting The Transmission Hydraulic System

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves


D Instructions/Parts. Siphon Feed Detail Spray Gun D

User Manual for: PE8 Series PE17 Series. Electric-Powered 8 & 17 Series Two-Stage Hydraulic Pump SPX

T1-Titanium Non-HVLP Spray Gun

Operating Instructions & Parts Manual

GPM Hydraulic Flow Meter User Manual

Installation. Installation. 12. System Diagram... 10

Gauge Adapter Instruction Manual

OPERATION AND MAINTENANCE MANUAL

Manifold w/ Needle Valve Instruction Manual

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL F AIR HYDRAULIC PUMP

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench -

ELECTRIC RJ SERIES RAIL JACKS

Fisher 657 Diaphragm Actuator Sizes and 87

Owner's Manual. Model: LS-PCO-100-GEM ( ) (100 Gallon Skid-Mounted High Pressure Sprayer) Technical Specifications. General Information

INSTRUCTION, GPT HAND PUMP KIT (BUCHER PUMP) INSTALLATION

TRANSFER PUMP INSTRUCTIONS P/N 14251NOS

ELECTRIC HYDRAULIC PUMP

1/2" AIR DRIVEN DIAPHRAGM PUMP

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

Hydraulic Gear Puller Instruction Manual

Instructions for Installation, Operation, Care and Maintenance

OPERATORS MANUAL for Electric Pressure Washers

Bench Press Max Capacity: 16.5 Ton

Air-Assist Service Jack Max. Capacity: 10 Tons

Clevis Plunger & Base Instruction Manual

HexPro Series Low Profile Wrenches

FRP SystemOne GELCOATER OPERATION MANUAL. MAGNUM VENUS PRODUCTS Operation Manual. Part No. M Revision

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

END SUCTION CENTRIFUGAL PUMPS

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) MODEL C ELECTRIC HYDRAULIC PUMP

Fuel System Diagnosis

Form No , 3, 4 5. Parts List for: MODEL F AIR HYDRAULIC PUMP. Maximum Capacity: 10,000 PSI. Item Part No. No. No.

ELECTRIC HYDRAULIC PUMP

Rams. Operating Instructions & Parts Manual. Model Number B65142 B65150 B65442 B65444 B65452 B Capacity 4 Ton 4 Ton 10 Ton 10 Ton 10 Ton 25 Ton

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

Operating Manual. High Performance Vacuum Pump Models and 15600

Low Profile Wrenches Operation and Maintenance Manual

Transcription:

SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800) 541-1418 Fax: (800) 288-7031 SPX Corporation 655 Eisenhower Drive Owatonna, MN 55060-0995 USA Phone: (507) 455-7000 Tech. Services: (800) 533-6127 Fax: (800) 955-8329 Order Entry: (507) 455-1480 Fax: (800) 283-8665 International Sales: (507) 455-7223 Fax: (507) 455-7746 IN-LINE HYDRAULIC FLOW TESTER The 75 GPM (300l/min.) and 200 GPM (750 l/min.) inline hydraulic flow testers are compact, self-contained, portable instruments for testing hydraulic systems in the shop or field. To simplify identification of the testers in this instruction sheet, the two versions are identified by their English (GPM) flow capacities. Individual components are identified in Figure 3. SAFETY PRECAUTIONS WARNING Before operating the pump, all hose connections must be tightened with the proper tools. Do not overtighten. Connections should only be tightened securely and leak-free. Overtightening can cause premature thread failure or can cause high pressure fittings to split at pressures lower than their rated capacities. Should a hydraulic hose ever rupture, burst, or need to be disconnected, immediately shut off the pump. Never attempt to grasp a leaking pressurized hose with your hands. The force of the escaping hydraulic fluid could cause serious injury. Do not subject the hose to potential hazard such as fire, sharp surfaces, heavy impact or extreme heat or cold. Do not allow the hose to kink, twist, curl or bend so tightly that the oil flow within the hose is blocked or reduced. Periodically inspect the hose for wear because any of these conditions can damage the hose and result in personal injury. Do not use the hose to move attached equipment. Stress may damage the hose and cause personal injury. Hose material and coupler seals must be compatible with the hydraulic fluid used. Hoses also must not come in contact with corrosive materials such as creosote-impregnated objects and some paints. Consult the manufacturer before painting a hose. Never paint the couplers. Hose deterioration due to corrosive materials may result in personal injury. SET-UP Form No. 102547 Operating Instructions for: HT200 014-051E CAS-10280 HT200P 4221 CAS-10283 MEL-10005 4222 D-01074AA WF-10054 4223 D-01075AA Y94A 4224 D-01169AA Y95 ACTP-1008 HT75 Y96A ACTP-1009 HT75P Y97 Battery Installation IMANT: If the tester is being operated on auxiliary power (not batteries), leave batteries in proper place and connected or insulate the battery contacts (both sides) to prevent shorting. The testers are provided with three nine-volt transistorized batteries that must be installed before operation. See Figure 1. 75 GPM Tester: Remove the four screws holding the battery panel on the underside of the tester. Remove the battery panel. Insert the batteries into the spring clips and fasten the battery contacts. See Figure 1. 200 GPM Tester: The battery panel is located to the right of the meter panel. Remove the two screws, and lift the panel from the case. Insert the batteries into the spring clips and fasten the battery contacts. See Figure 2. 3 NINE VOLT BATTERIES BATTERY PANEL BATTERY PANEL 3 NINE VOLT BATTERIES 75 GPM Tester 200 GPM Tester Figure 1 Sheet No. 1 of 4 SPX Corporation

Operating Instructions, Form No. 102547, Back sheet 1 of 4 Fittings 75 GPM Tester: The inlet and outlet ports (shown in Figure 2) are designed for SAE straight o-ring union adapters, 1-1/16-12 male thread by 3/4 NPSM female straight union. When the tester is not being used, always insert the port plugs to protect the unit from damage or contamination. 200 GPM Tester: The inlet and outlet ports (shown in Figure 2) are designed for SAE Standard 1 1/2 inch, 4-bolt split flange fittings. Flange bolts must be 1/2-13 UNC by 1 1/2 inch long SAE Grade 5 with spring lockwashers, torqued at 55/65 ft. lbs. When the tester is not being used, always assemble the cover plates to protect the tester from damage or contamination. Hoses 1. Connect the pressure hose from the pump or pressure line of the system to the tester INLET port. 2. Connect the return hose to the tester OUTLET port. NOTE: If the hoses are connected wrong, the tester gives flow readings but the pressure control valve does not function. No damage to the unit occurs. TESTER CONNECTION S 75 GPM 200 GPM OUTLET SAFETY DISC HOSE CONNECTOR INLET Figure 2 OUTLET SAFETY DISC HOSE CONNECTOR INLET Operating Controls Both testers have similar operating controls, but the location of the controls may differ. Some controls are not available if the tester does not have the phototach accessory. Refer to Figure 3. : Pull this switch to turn the tester ON; push to turn the tester OFF. When the tester is not being used, the switch must be in the OFF position. METER: The meter displays flow and temperature readings, depending on the setting of the FLOW/RPM switch. IMANT: In an extremely dry environment, a static charge can build up on the meter face causing a false meter reading. To detect this condition, touch the meter face on either side of the needle. If the needle changes its position, discharge the meter face by wiping with a damp cloth. FUSE: The fuse protects the meter from sudden power surges when using auxiliary power. LOW BATT: This indicator light alerts the operator that battery power is low, which can result in false readings. FLOW/RPM: Set this switch to read either flow or revolutions per minute on the meter. HI/LOW RANGE: Use this switch to set the range for the flow meter. Refer to the following chart: GPM l/min 75 GPM Tester 3-15 10-60 Low Scale 15-75 50-300 High Scale 200 GPM Tester 5-40 20-150 Low Scale 25-200 100-750 High Scale TEMP: When this switch is toggled ON, fluid temperature is displayed on the meter temperature scale in both degrees Fahrenheit and Celsius. When the toggle switch is released, the meter returns to its previous mode. AUX PWR: Insert optional auxiliary power sources into this jack. CAL: This jack is provided for calibration instrument input. LIGHT: This is a two position toggle switch for the tachometer. INPUT: Insert the optional phototach electrical cable into this jack. RPM SELECTOR: This is a multi-position switch that allows selection of six different tachometer ratios.

Operating Instructions Form No. 102547 CONTROL VALVE: The pressure control valve regulates system pressure by restricting the flow to develop back pressure in the system. The control valve maintains the pressure setting during and after change in flow. To increase pressure, turn the control valve clockwise; to reduce pressure, turn the control valve counterclockwise. IMANT: Before testing the system, open the pressure control valve all the way by turning the valve counterclockwise. Increase pressure SLOWLY. NOTE: Oil the pressure control valve regularly. Each time the flow tester is connected to a hydraulic system for testing, the unit may be noisy the first time pressure is increased with the control valve. The noise is caused by air trapped in the internal parts of the control valve. To flush the air out, increase pressure to approximately 2000 PSI and then back to 0 PSI. It may be difficult to adjust the pressure control valve when testing in a closed center system or under high back pressure. Even when the control valve stem threads are lubricated with a good grade of oil, the valve becomes difficult to adjust by hand at approximately 1100 PSI back pressure and almost impossible to adjust by hand at approximately 1600 PSI back pressure. S: Pressure readings are taken from the high pressure (0-6000 PSI, 0-410 BAR) and low pressure (0-600 PSI, 0-41 BAR) gauges on the flow block. As pressure increases, the low pressure gauge gives readings up to 500 PSI (35 BAR) and then cuts out, switching to the high pressure gauge. SNUBBER KNOB: A gauge snubber knob is located at the lower left corner of the gauge block. To dampen (slow) the movement (pulsation) in the gauge needles, turn the snubber knob clockwise at a low pressure setting. NOTE: When the gauges are dampened, the reaction time of the needles will be slow. Build pressure very slowly to allow time for the needles to react. HIGH SNUBBER KNOB FUSE CALIBRATION AUXILIARY POWER METER DIAL (FLOW, TEMP.) TEMP HIGH SNUBBER KNOB METER DIAL (FLOW, TEMP.) TEMP FUSE AUXILIARY POWER CALIBRATION Figure 3 Operating Controls 75 GPM FLOW/RPM 200 GPM HI/LOW RANGE SWTICH LOW HI/LOW RANGE SWTICH LOW LIGHT CONTROL VALVE LOW BATT INDICATOR LIGHT RPM SELECTOR LIGHT INPUT CONTROL KNOB LOW BATT INDICATOR LIGHT RPM SELECTOR FLOW/RPM INPUT OVERLOAD PROTECTION SAFETY DISC: A safety disc located at the back of the tester (See Figure 2) protects the flow tester from extreme pressure. If pressure exceeds the ranges listed in the following chart, the disc ruptures, relieving oil and reducing pressure before damage can occur. A hose connector surrounds the disc to act as a shield against oil spray should the disc rupture. For more protection, a 1 1/4 inch I.D. hose should be inserted into the connector and clamped in place. This hose should be long enough to direct oil back to the reservoir or another container. Safety Disc Burst Range 75 GPM 5510/6093 PSI @ 60 F 5250/5835 PSI @ 160 F 200 GPM 5220/6790 PSI @ 105 F 6000/7000 PSI @ 72 F Sheet No. 2 of 4

Operating Instructions, Form No. 102547, Back sheet 2 of 4 PHOTOTACH ACCESSORY Use the phototach accessory to read an object s RPM on the high or low flow scale (depending on the position of the HI/LOW RANGE selector switch). NOTE: The phototach accessory must be used with an auxiliary power source because the phototach requires more power than the batteries can supply. WARNING To help prevent personal injury, Stay clear of all moving mechanical parts while using the tachometer. The object to be tested must be motionless while applying the lightreflective material. 1. Apply a light-reflective material (such as a small piece of white tape) to the object. 2. Insert the electrical cable of the phototach assembly into the INPUT jack on the tester panel. 3. Set the FLOW/RPM toggle switch to RPM. To turn the phototach pickup bulb ON, set the LIGHT switch to the ON position for incandescent sensor and OFF for infrared sensor. 4. Hold the phototach pickup perpendicular to, and within 12 inches of the reflecttive material on the rotating object. Read the flow meter on the tester. INFRARED SENSOR MAGNETIC BASE ACCESSORIES (For more complete descriptions, request a current catalog from your distributor.) Calibrator Use the calibrator to check meter readings on the 75 or 200 GPM hydraulic tester at any time the tester is not connected into a hydraulic system. Insert the cable from the calibrator into the CAL jack on the tester. Under normal conditions, the meters should be calibrated about every six months to a year. However, the calibrator should be used whenever flow readings seem suspect or when the tester has been repaired. THUMB WHEEL ROTARY Auxiliary Power Cord This power cord is convenient for field use as a back-up if the internal battery power drops too low to operate the tester. The unit draws power from a 12 or 24 volt vehicle battery and automatically overrides tester internal battery function without harming good batteries. The Auxiliary Power Cord can be used with any tester. NOTE: Do not use this cord on positive (+) ground systems. Use only internal batteries or auxiliary power converter. LOW BATTERY INDICATOR LIGHT CALIBRATOR Auxiliary Power Converter By using this power converter, any tester can be operated from any 120 volt, 60 cycle outlet. AUXILIARY POWER CONVERTER AUXILIARY POWER CORD Note: Shaded areas reflect last revision(s) made to this form.

Operating Instructions Form No. 102547 TYPICAL TESTING PROCEDURES The following test procedures show how the tester can be used to located a problem in the hydraulic system by checking the efficiency of each component. In this example, the system consists of a reservoir, pump, relief valve, directional control valve and double-acting cylinder. EXAMPLE OF A PROBLEM: The cylinder s piston moves out a almost normal speed under no load, but gradually slows down as the load increases. 1. Check all hoses and connections for leakage before beginning any test. TESTING THE PUMP (See Figure 4) IMANT: Do not allow the pressure reading on the tester gauges to exceed the maximum relief valve pressure of the pump. Serious damage to the pump can result because the system relief valve no longer protects the pump. 1. Shut the pump OFF, and place the control valve in the neutral position. Disconnect the line between the pump and relief valve. 2. Connect line A (outlet from the tester) to the pressure port of the relief valve. 3. Connect line B (inlet of the tester) to the discharge port of the pump. Symptom: If the action of the gauges is erratic, and severe pulsations occur even after the dampener knob has been adjusted, cavitation could be a problem. Solution: Check the oil level, filter and suction line. 6. Induce a load on the pump with the tester pressure control valve at approximately 50% o f the maximum system pressure. Slowly increase pressure by turning the control valve clockwise while watching the pressure gauges on the tester. 7. When normal operating temperature is reached (per manufacturer s specification), open the tester pressure control valve. Record the volume at low pressure displayed on the flow meter. 8. Increase pressure by turning the handle clockwise, maintaining required engine RPM at all pressure check points. Record the volume at various increments up to maximum pressure. 9. Open the pressure control valve and shut off the pump. Compare the test result against the manufacturer s specifications. Symptom: Low flow readings. Solution: Repair pump, suction line or filter. If the flow readings are OK, test the relief valve next. Figure 4 Sheet No. 3 of 4

Operating Instructions, Form No. 102547, Back sheet 3 of 4 TESTING THE RELIEF VALVE (See Figure 5) IMANT: When testing the system relief valve, refer to the valve manufacturer s manual to determine the relief valve setting. 1. Shut the pump OFF, and place the control valve in the neutral position. Disconnect the line between the relief valve and the directional control valve. 2. Connect the line A (outlet from the tester) to the pressure port of the directional control valve. 3. Connect the line B (inlet of the tester) to the discharge line after the relief valve. 6. When normal operating temperature is reached (per manufacturer s specification), maintain the required engine RPM at all pressure check points. 7. Turn the tester pressure control valve clockwise until the relief valve setting has been reached. (The relief valve setting is easily recognized. The pressure gauge needle will fluctuate, indicating unloading or bypassing of oil over the relief valve. The GPM indicator will shown a decrease in flow through the tester indicating that the balance of pump output is going through the relief valve.) Record volume and pressure at various increments to maximum pressure. Symptom: The pressure at which the flow falls to 0 (the relief pressure) is lower than maximum operating pressure. Solution: Adjust the relief valve. Symptom: The flow reading on the tester is not the same as the pump. Solution: The relief valve is leaking and must be repaired. If the problem is not in the relief valve, test the directional valve next. Figure 5 TESTING THE DIRECTIONAL VALVE (See Figure 6) 1. Shut the pump OFF, and place the control valve in the neutral position. Disconnect the line between the cylinder and the tee. Plug the port on the tee. 2. Connect line A (outlet from the tester) to reservoir. 3. Connect line B (inlet of the tester) to the outlet port on the directional control valve. 6. When normal operating temperature is reached (per manufacturer s specification), shift the directional valve from neutral to the advance (lift) position. This directs the oil to line B (the inlet port of the tester). 7. Turn the tester pressure control valve clockwise until the relief valve setting has been reached. Record volume and pressure at various increments to maximum pressure, maintaining required engine RPM at all pressure check points. 8. Repeat this test procedure on the other side of the directional control valve. Symptom: Full volume and pressure can not be reached. Solution: Repair or replace the directional control valve. If full rated volume at full pressure is recorded, the problem must be in the cylinder. Figure 6

Operating Instructions Form No. 102547 TESTING WITH A TEE CONNECTION (See Figure 7) The following procedure illustrates a method of testing overall circuit performance. 1. Shut the pump OFF, and place the control valve in the neutral position. 2. Connect line A (outlet from the tester) to reservoir. 3. Connect line B (inlet of the tester) to a tee connection in the circuit between the control valve and cylinder. 6. When normal operating temperature is reached (per manufacturer s specification), shift the directional valve from neutral to the cylinder extend position. 7. Partially close the tester pressure control valve to allow the cylinders to extend and dead-end. NOTE: If design characteristics of the cylinder make a dead-end inadvisable, a greater-than-capacity load can be put on the unit to simulate dead-ending. Oil will flow to the reservoir either through the tester or through leaks in components of the circuit. 8. Record the flow at no load. Increase the load on the circuit by slowly closing the tester pressure control valve. Record the flow at various pressure check points, maintaining required engine RPM. The difference in readings indicates oil lost because of leaks somewhere in the circuits. Figure 7 Sheet No. 4 of 4