Operating Instructions

Similar documents
Drive Technology \ Drive Automation \ System Integration \ Services. Data sheet. MOVIAXIS Multi-Axis Servo Inverter. Information regarding UL

Data Sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61B MOVIDRIVE compact, MOVIDRIVE A Information regarding UL

Data sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61A, MOVIDRIVE compact, MOVIDRIVE A Information regarding UL * _0119*

Data sheet. MOVITRAC 07B, MOVITRAC 07A Information regarding UL * _1216*

moog MSD Servo Drive UL-Certification MSD Servo Drive product range

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV

Revision MOVITRAC LTE-B * _1114*

Revision. Mechatronic Drive System MOVIGEAR DBC-B, DAC-B, DSC-B, SNI-B, * _0315*

8 BK brakes. 8.1 Description of BK brakes (CMP40 to CMP63) Description of BK brakes (CMP40 to CMP63)

For regenerative operation, the MOVIPRO is connected to an external braking resistor.

Brake Chopper BC BC 4.1. Instruction and Operation Manual

Manual. Conversion Aid MOVIDRIVE MDR60A Regenerative Power Supply Unit Series from DCV185 to DCV200

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Drive Technology \ Drive Automation \ System Integration \ Services. Revision MOVIFIT FC

Synergy EN product information

Addendum to the Operating Instructions

Kinetix 5700 Capacitor Modules

Braking resistor. Braking resistor types for Infranor drives.

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B. Revision. Edition 07/ / EN

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Question Number: 1. (a)

Description CMP servomotors are delivered with 2-pole resolvers as standard. Further information on other resolvers is available on request.

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

BT300 Variable Frequency Drive Bypass

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

ABB industrial drives ACS800, drive modules. 2 to Vac 5 to Vac

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

Technical Information

Compliance with CE Marking and UL Standard

Edition. Spiroplan W10 DT56 Geared Motor 06/ x / EN

1.1 Caution Statements

Braking Unit, Braking Resistor Unit

SUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

Applications DC Motors Stepping and Servos Solenoid Valves Relays Lamps and Signal Systems Input to On-Board Regulators Some Floppy Disc Drives.

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Operating Instructions

Caution: Wear protective goggles danger of chipped pieces! 01733AXX

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Manual. Brake Diagnostics (as of V ) * _0415* Phone: Fax: Web: -

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

ABB machinery drives. Application guide Common DC system for ACS380 drives

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Low-Peak 600V Class RK1

COLLEGE PHYSICS Chapter 21 CIRCUITS, BIOELECTRICITY, AND DC INSTRUMENTS

ABB industrial drives ACS800, drive modules 0.55 to 2900 kw Catalog

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Emotron FDU and VFX 2.0

Installation Instructions Bus Bar Kit for 6-pulse, 4-drive System VLT Series FC 102, FC 202, and FC 302. Description. Kit Part Number.

ZE motor-protective relay Overload monitoring of EEx e motors

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

SDC,Inc. SCR-Regenerative Ac Drive

MAGNETIC MOTOR STARTERS

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

COMBIVERT F5 ELEVATOR DRIVE

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

Transforming Energy.. For Advanced Technology

General Purpose US Fuses

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

SD Series Non-Fused Load Switches

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Drives in Common Bus Configurations with PowerFlex 755TM Bus Supplies

SMT-BM 20 A BMM 05 F BMM 05 AF

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Hitachi America, Ltd.

Series L9 UL-489 Miniature Circuit Breakers

Functions provided by measuring relays in railway equipment

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

Braking Unit, Braking Resistor Unit

EDB6032_G/GB Antriebstechnik. Operating Instructions. Brake chopper 6032/6033/6034

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

SRC 311. Technical Specification

DISCONTINUED PRODUCT POWER PROTECTION. Series 600 UPS. Multi-Module Three Phase 338 kva to 1000 kva; 60 Hz. Installation Manual

Electrical Wiring Practices

SIRIUS 3RU2 Thermal Overload Relays

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Power systems Protection course

Brake Resistor Design Guide. How to Read this Design Guide 3 Abbreviations 4. Safety Precautions 5 CE Conformity and Labelling 5

5. Installation on Pedestal - IP 21 / IP 54 Units 43

to allow a current in one circuit to operate a switch in another circuit to protect a circuit by melting if the current becomes too large

Thermal overload relay TF65 and TF96

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

OTEC Transfer switch open transition

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

ELECTRICAL POWER and POWER ELECTRONICS

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

Thermal overload relay TF140DU and TF140DU-V1000

MaxPak Plus Analog DC V S Drive

SUBMITTAL SAVCPC AQUAVAR CPC. (Centrifugal Pump Control)

Transfer switch OTEC open or delayed transition

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Braking unit Option Instruction Manual PB7-4132K

Type C Track Circuit Uninterruptable Power Supply

Transcription:

Drive Technology \ Drive Automation \ System Integration \ Services Operating Instructions MOVIAXIS MultiAxis Servo Inverter Information regarding UL Edition 0/0 685 / EN

SEWEURODRIVE Driving the world

Contents Contents Information regarding UL.... Field Wiring Power Terminals.... Short Circuit Current Rating.... Branch Circuit Protection... 5. Overload Protection... 5.5 Ambient Temperature... 5 Wiring diagrams... 6. Connection of supply module, capacitor / buffer module, axis module, brake and V switchedmode power supply module... 6. Connecting braking resistors... 0..... Connecting of regenerative power module... 5 Information regarding UL MOVIAXIS MultiAxisServo Inverter

Information regarding UL Field Wiring Power Terminals Information regarding UL. Field Wiring Power Terminals Use 60 / 75 C copper wire only. Tighten terminals to inlbs (Nm) as follows Tightening torque Power supply module Mains connection X Braking resistor terminals Size.5 5.05 in.lb (0.5 0.6 Nm).5 5.05 in.lb (0.5 0.6 Nm) Size.55 5.0 in.lb (.0.0 Nm).55 5.0 in.lb (.0.0 Nm) Size 5.05 88.508 in.lb (6.0 0.0 Nm).55 5.0 in.lb (.0.0 Nm) Regenerative power module Mains connection X Emergency braking resistor terminals One size 5.05 88.508 in.lb (6.0 0.0 Nm).55 5.0 in.lb (.0.0 Nm) Regenerative power module Mains connection X EcoLine Filter 06..76 in.lb ( 5 Nm) connection X Size.5 5.05 in.lb (0.5 0.6 Nm) Size 0.6.76 in.lb (..5 Nm) Size.76 5.06 in.lb (.5.7 Nm) Size.55 5.0 in.lb (.0.0 Nm) Size 5.55 5.0 in.lb (.0.0 Nm) Size 6 5.05 88.508 in.lb (6.0 0.0 Nm) DC link discharge module Braking resistor connection X5 All sizes.55 5.0 in.lb (.0.0 Nm) Models DClink bars All Models.55 5.0 in.lb (.0.0 Nm). Short Circuit Current Rating Suitable for use on a circuit capable of delivering not more than,000 rms symmetrical amperes: Max. voltage is limited to 500 V. Information regarding UL MOVIAXIS MultiAxisServo Inverter

Information regarding UL Branch Circuit Protection. Branch Circuit Protection Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with National Electrical Code and any additional local codes. MXP power supply module 0 kw 5 kw 50 kw 75 kw Input fuse 0 A 0 A 80 A 5 A MXR80A075 "Maximum Power" variant "Clean Power" variant regenerative power module Input fuse 5 A 80 A MXR8A 75 kw 50 kw regenerative power module Input fuse 50 A 00 A If you use cable cross sections that are dimensioned for a smaller current than the rated current of the unit, make sure that the fuse is dimensioned for the used cable cross section. For information on selecting cable cross sections, refer to the project planning manual. Comply with the countryspecific installation regulations in addition to the above notes. The plugin connections of the V supply are limited to 0 A. Option cards that are supplied via the 0 V and V terminals at the front must be protected individually or in groups by A melting fuses according to UL 8.. Overload Protection The units are provided with motor overload protection with a trip current adjuated to 50 % of the rather motor current..5 Ambient Temperature The units are suitable for an ambient temperature of 5 C. NOTES UL certification does not apply to operation in voltage supply systems without earthed star point (IT systems). Information regarding UL MOVIAXIS MultiAxisServo Inverter 5

Wiring diagrams Connection of supply module, capacitor / buffer module, axis module, brake Wiring diagrams. Connection of supply module, capacitor / buffer module, axis module, brake and V switchedmode power supply module.. Wiring of power terminals MXP80.. Size and L L L K L L L Line filter L L L X L L L Cable length < 600 mm ) ) ) ) ) ) Capacitor module Supply module R R U V switchedmode power supply unit X X For connection of BW see chapter "Connection of braking resistor" ** ) = DC link bus bar = (grounding point of housing) = Power shield clamp 65977 * When F6 (trip contact at overload relay) triggers, K must be opened and DI00 "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. ** Make sure to provide separate isolation for the brake lines when ling the brakes with V. We recommend using SEW hybrid cables that offer complete shielding with shielding supports as well as separate shielding for the brake line. *** Install the connection cables between the brake rectifier and the brake separately from other power cables when installing the brake rectifier in the cabinet. Joint installation is only permitted with shielded power cables. 6 Information regarding UL MOVIAXIS MultiAxisServo Inverter

Wiring diagrams Connection of supply module, capacitor / buffer module, axis module, brake.. Wiring of power terminals MXP80.. Size L L L K L L L Line filter L L L Cable length < 600 mm X L L L ) ) ) ) ) ) Capacitor module Supply module R R X U X V Switchedmode power supply unit For connection of BW see chapter "Connection of braking resistor" ** ) = DC link bar = (housing grounding point) = Power shield clamp 6597705 Footnotes: (page 6) Information regarding UL MOVIAXIS MultiAxisServo Inverter 7

Wiring diagrams Connection of supply module, capacitor / buffer module, axis module, brake.. Wiring the MXP8.. power connections with integrated braking resistor L L L K X L L L Line filter L L L Cable length < 600 mm L L L Supply module Ri R R Ri U X ** X = (Housing grounding point) = Power shield clamp 659797 Footnotes: (page 6) 8 Information regarding UL MOVIAXIS MultiAxisServo Inverter

Wiring diagrams Connection of supply module, capacitor / buffer module, axis module, brake.. Wiring the MXP8.. power connections with external braking resistor L L L K X L L L Line filter L L L Cable length < 600 mm L L L Supply module Ri R R Ri U X Connection of BW see chaoter Connection of braking resistor ** X = (Housing grounding point) = Power shield clamp 65995 Footnotes: (page 6) Information regarding UL MOVIAXIS MultiAxisServo Inverter 9

Wiring diagrams Connecting braking resistors. Connecting braking resistors Supply module X R R Supply module X R R BW...P 6 97 95 F6 98 96 affects K RB RB BW...T T T F6 affects K Supply module X R R Supply module X R R F6 affects K F6 affects K Ω BW... BW...0 655907 BW...P BW...T BW..., BW...0 If the signal contact F6 trips, K must open. When F6 (trip contact at overload relay or temperature switch) triggers, K must open and "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. When the internal temperature switch trips, K must open. When F6 (trip contact at overload relay or temperature switch) triggers, K must open and "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. When the external bimetallic relay (F6) trips, K must open. When F6 (trip contact at overload relay or temperature switch) triggers, K must open and "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. Braking resistor type BW.. BW...0 BW...T BW...P Overload protection External bimetallic relay F6 External bimetallic relay F6 Internal temperature switch or External bimetallic relay F6 Internal bimetallic relay F6 0 Information regarding UL MOVIAXIS MultiAxisServo Inverter

Wiring diagrams. BMK brake with terminal box U ** *** X 5a a a K U AC 5 BMK TS BS BMK brake with SB plug connector 65807 U ** *** X K 5 BMK TS BS U AC BMK brake with SBB plug connector 65809 U ** *** X D B C K 5 BMK TS BS UAC 658755 Footnotes: (page 6) Information regarding UL MOVIAXIS MultiAxisServo Inverter

Wiring diagrams BME brake with terminal box U ** *** X U AC 5a a a F/5 TS BS K DB00 K DGND 5 BME Directly led motor brake 65989 U ** X 659988 Footnotes: (page 6) Information regarding UL MOVIAXIS MultiAxisServo Inverter

Wiring diagrams BP brake BMV with terminal box U ** *** X 5a a K DC V 5 BMV BP brake BMV with SB plug connector 65057 U ** *** X D C K DC V 5 BMV BP brake BMV with SBB plug connector 650 U ** *** X K DC V 5 BMV 650875 Footnotes: (page 6) Information regarding UL MOVIAXIS MultiAxisServo Inverter

Wiring diagrams BY brake BMV with terminal box U ** *** X 5a a a K DC V 5 BMV TS BS BY brake BMV with SB plug connector 650659 U ** *** X D B C K DC V 5 BMV TS BS BY brake BMV with SBB plug connector 65080 U ** *** X K 5 BMV TS BS DC V 6509867 Footnotes: (page 6) BST brake For information about BST brake, refer to the "BST SafetyRelated Module" operating instructions. Information regarding UL MOVIAXIS MultiAxisServo Inverter

Wiring diagrams Connecting of regenerative power module. Connecting of regenerative power module.. Wiring of the power connections without NFH EcoLine filter L L L N DC V 5 6 Cable length 5 m A A K ** K F6 * NOT AUS *** U V W L L L X8 Line filter L L L OFF Cable length.5 m / AWG U Choke U X Cable length.5 m ON K L L L W V U X8 Sa Sb X9 Regenerative power module R R U X X = (grounding point of housing) = Power shield clamp 659665 * When F6 (trip contact at overload relay) triggers, K must be opened and "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. ** Emergency stop release delay only in line with applicable system and countryspecific safety regulations and customer specifications. Information regarding UL MOVIAXIS MultiAxisServo Inverter 5

Wiring diagrams Connecting of regenerative power module.. Wiring of the power connections with NFH EcoLine filter L L L N DC V 5 A A K F6 * 6 L L L NFH K EMERG. STOP** Cable length 5 m Cable length.5 m / AWG U V W L L L L L L X8 Line filter L L L U Choke U X OFF ON K Cable length m Cable length.5 m L L L W V U X8 Sa Sb X9 Regen. supply module R R U X X = (housing grounding point) = Power shield clamp 65999 Footnotes: (page 5) 6 Information regarding UL MOVIAXIS MultiAxisServo Inverter

SEWEURODRIVE Driving the world SEWEURODRIVE Driving the world SEWEURODRIVE GmbH & Co KG P.O. Box 0 D766 Bruchsal/Germany Phone 9 75 750 Fax 9 75 75970 sew@seweurodrive.com www.seweurodrive.com