Parking space border or support. Drive axis 15 L

Similar documents
Parking space border or support. Drive axis 15 L

PRODUCT DATA. crosswise shifting 2000 kg / 2600 kg

PRODUCT DATA kg

Free space car height car height. height 340 (330) height 360 (340) car height car height

Barrier. Delimitation car height lower level car height lower level

Free space height 340 (330) height 360 (340) height 400 (360) height

PRODUCT DATA. Parking Automat P kg 1

Data Sheet WÖHR PARKING PLATFORM 501

Product Data SingleVario

Product Data SingleVario 2061

Stack Parking Surface Mounted Stackers

PRODUCT DATA. Tower system. The tower system can be. Higher loads per parking. upon request

Available in 5 platform widths from 7'-7" to 8'-11" Available in 2 headroom heights: 5'-9" and 6'-11" Available in 4400 lbs or 5060 lbs load capacity

PRODUCT DATA. Parking Automat P kg 1

TECHNICAL SPECIFICATION SEMI-AUTO BI-DIRECTIONAL MAX 2 SMART SOLUTIONS FOR VEHICLE PARKING AND CAR STORAGE

December 23, 2013 Our Ref: TR Queen East Limited c/o The Andrean Group 1013 Wilson Avenue, Suite 201 Toronto, ON M3K 1G1

LIFTPARKER N4100 S/D. The best solution for. ceiling heights below 3m

STOREPARKER SERIES STOREPARKER N2503 THE DEPENDENT PARKING SYSTEM ON 3 LEVELS WITHOUT PIT DEPENDENT PARKING SYSTEMS

Quadro Outdoor T2 S/D

To retrieve #5 platform first #6 platform be lifted up. entrance level.

PARKLINE SERIES PARKLINE N5102 THE SEMI-AUTOMATIC PARKING SYSTEM WITHOUT PIT AND NO COLUMNS AT THE ENTRY SEMI AUTOMATICS SHORT DESCRIPTION

Carlift Series PHP 220F

PRODUCT RANGE. we compact parking space. Otto Wöhr GmbH Auto-Parksysteme

Operating Instructions Pedestrian Turnstile Type MPT 33

Assembly and Operating Instructions

The #PT platform then slides under #2 and #4 platforms to cover the now-empty space.

Fully automatic parking systems. Always a premium solution

so increased accessibility

UNIPARKER SERIES UNIPARKER N5303 THE SEMI-AUTOMATIC PARKING SYSTEM WITH PIT AND WITHOUT COLUMNS AT THE ENTRY SEMI-AUTOMATICS SHORT DESCRIPTION

PARKLINE N5803 PARKLINE SERIES THE SEMI-AUTOMATIC PARKING SYSTEM ON 3 LEVELS, WITHOUT PIT SEMI-AUTOMATICS

When platform #4 is requested. Platform #3 and #5 shift to the left. Then platform #4 is lowered to the entrance level.

Moisture-proof cable branch boxes Ceiling distribution boxes Lamp suspension boxes Wall boxes Concrete wall boxes and accessories

Underfloor Wheel Lathe Type U CNC-controlled machine with automatic measuring system

Parkonfor Series. Parkist C Series Parkist 1C - 11C - 111C / 2C - 22C - 222C

Dropped Crossing Service

Semi-automatic parking systems. The urban trend in parking

Operating Instructions Type MPT 53

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011

Technical data/component parts

TTM Consulting (Vic) Pty Ltd

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

2 PARK SPECIFICATIONS

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

Battery Pack Charger OpenStage WL 3 / OpenStage WL3 Plus. Installation Guide A31003-M2000-J

Traffic Guidance Signs Type TGS and Retrofit-Kit

Robots. KUKA Roboter GmbH. KR QUANTEC extra HA. Specification KR QUANTEC. extra HA. Issued: Version: Spez KR QUANTEC extra HA V4

CAR PARKING SYSTEMS Program overview

OPERATING INSTRUCTIONS. Operating Instructions

LIFTPARKER N4602 LIFTPARKER SERIES THE OPTIMIZED SOLUTION WITH OFFSET COLUMNS CAR STACKERS

Energy Supply Systems

Regulations relating to the Use of Vehicles, Chapter 5

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

Backflushing Filter AutoFilt RF3

Operating Instructions. Globoidal cam gear

RUBBER BELLOWS TYPE 1A & 1S SERIES

BODYWORK FITTING GUIDE 1/398 English edition 06/2007. Recommendation "free space to the rear of the cab for positioning the crane feet"

NOTE Please read this Operating Manual carefully before first using the device and strictly adhere to the instructions!

AXIAL FANS Axis / Tubo OPERATION MANUAL

M A N U A L. Field Current Controller F2.2

Electromotoric Actuators

GTK 80. Technical data

KR 30, 60-3; KR 30 L16-2

INTRODUCTION TO EMIP PROJECT

SECTION VII METERING INSTALLATIONS

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

MEYER-Rotating Fork Positioners are attachments used to transport loads and replace

KR 30, 60-4 KS; KR 60 L16-2 KS

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Solenoid Operator 0516 / 1216

Standard. Industrial Storage Technology

ARTICLE 8 OFF-STREET PARKING AND PRIVATE DRIVEWAY STANDARDS

KR QUANTEC prime. Robots. With F and C Variants Specification. KUKA Roboter GmbH. Issued: Version: Spez KR QUANTEC prime V10 KR QUANTEC

PN /21/ SURFACE SMOOTHNESS REQUIREMENTS FOR PAVEMENTS

Electrical operating instructions

Body assembly guidelines Volkswagen Nutzfahrzeuge

Original operating instructions. Transit silo. Model. Transit silo

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

LIFTPARKER N4102 LIFTPARKER SERIES THE IDEAL SOLUTION IN CASE OF LOW CLEAR HEIGHTS CAR STACKERS

Technical specifi cation Slipform Paver SP 15 / SP 15 i

LIFTPARKER N4403 LIFTPARKER SERIES THE IDEAL SOLUTION IN 3 PLATFORM LEVELS FOR DEEPER PITS AND HIGH CLEAR HEIGHTS CAR STACKERS

0 = 0 mm rear cover panel edging (standard) Number = rear cover panel edging according to table

PN 420-7/18/ SURFACE SMOOTHNESS REQUIREMENTS FOR PAVEMENTS

ZB0050 / ZB0051 ZB0070 / ZB0071

Installation and Maintenance Manual. End Terminals

LIFTPARKER N4202 LIFTPARKER SERIES THE IDEAL SOLUTION FOR AN ADJUSTABLE CAR HEIGHT CAR STACKERS

JUNG PUMPEN COMPLI 1500 / 2500 SEWAGE LIFTING STATIONS

Robots. KUKA Deutschland GmbH KR QUANTEC PA. With HO and arctic Variants Specification KR QUANTEC. Version: Spez KR QUANTEC PA V9

ELVORON HOME ELEVATOR

Reinforced edge channels KE-100

Home Elevator. Planning Guide

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

Instruction manual and installation guide Traction sheave brake TSB TSB

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

DESCRIPTION, TECHNICAL SPECIFICATION, OPERATION, AND MAINTENANCE MANUAL FOR THE ISU-SYSTEM INNOVATIVER SATTELANHÄNGER UMSCHLAG

TRASH RACK CLEANING MACHINE

Product card User manual. Koliber Safes Koliber Deposit Drop Safes KSN Wall Safes Grade S1

180 ZONING 180. ARTICLE XXX Parking Minimum required automobile parking spaces. [Amended by Ord. No. 464; by Ord. No.

Operating Instructions. Parallel shaft cam gear

Transcription:

Page 1 Car Headroom according to local regulations 9,5 Warning light B Direction of movement KLAUS Multiparking GmbH Hermann-Krum-Straße 2 D-319 Aitrach Fon +49 (0 ) 75 65 5 0-0 Fax +49 (0 ) 75 65 5 0- info@multiparking.com www.multiparking.com 32 Parking space border or support PRODUCT DATA longitudinally shifting 00 kg / 2300 kg Type PE-215 PE-245 PH-215 PH-245 1 2 Top edge finished floor Tolerances for the evenness of the carriageway must be strictly complied with in accordance with DIN (= German Industrial Standard) No. 12, chart 3, line 3. All space requirements are minimum finished dimensions. Tolerances for space requirements +3 0. in cm. L 500 530 1000 1060 B 215 245 215 245 Travel path 470 500 970 1030 3 Suitable for Standard passenger cars: Limousine, station wagon, SUV, van, according to specifications in the table and maximal surface load. Wheel-location recess Drive axis Standard Special 2 width max. 190 cm max. 190 cm length max. 500 cm max. 500 cm height weight wheel load 10 cm less than headroom max. 00 kg max. 500 kg max. 2300 kg max. 575 kg Travel path 15 L ParkBoard PE ParkBoard PH 1 2 Building law requirements According to the German Building Code parking spaces on longitudinally shifting parking pallets are only permitted if the following requirements are met: Next to the ParkBoards a remaining driving lane width of 275 cm minimum must be maintained. ParkBoards must not be installed before power-driven parking systems. In case of two-way traffic in the driving lane no through traffic is permitted. The ParkBoards must be traversable on all sides. Walkable areas must provide headroom of 0 cm. Make sure to observe the ventilation systems, bearers or other s. The ParkBoards have a height of 9,5 cm. Standard type Special system: maximum load (PE-245/PH-245) for extra charge. 3 To follow the minimum finished dimensions, make sure to consider the according to VOB, part C (DIN 1330 and 1331) and the DIN 12. ParkBoard PE/PH Code number 54.16.990-005 Version 03.13

ParkBoard PE/PH Code number 54.16.990-005 Version 03.13 of 6 Page 1 Car : Longitudinal pallets with above-floor drive () 1 x ParkBoard PE 1 x ParkBoard PH 515 500 500 500 1015 1000 1000 1000 650 650 4 4 acc. to local requirements 1015 1015 2 x ParkBoard PE 2 x ParkBoard PH 650 4 500 650 4 1015 1000 1015 acc. to local requirements 3 x ParkBoard PE Combination 3 x ParkBoard PH 650 4 500 500 650 4 1015 1000 1000 1015 At a length of 40 m up to 5 pallets can be arranged as group should their shifting path overlap. In this case the operating elements must be within a distance of 10 m of a possible point of contact between two pallets. 4 Recommendation of KLAUS Multiparking. Above-floor drive () or support Cover marked with yellow/black stripes Cable mounted to support Drive dowelled to floor 5 49 33 If distance to support > 49, cable cover is required! 30 and (abstract from DIN 1 2, table 3) The distance between the lower flange of the ParkBoards and the garage ground must therefore not exceed 2 cm. To adhere to the safety regulations and DIN EN 14 010 recommendations and to get the necessary even ground, the of evenness to DIN 12, table 3, line 3, must not be exceeded. Therefore exact levelling of the ground client is essential. Column 1 2 3 4 5 6 Vertical measurement as limits in mm with measuring points distances in m to Line Reference 0,1 1 4 10 15 Unfinished to surface of covers, subconcrete and subsoils for higher 2 demands, e.g. as foundation for cast plaster floor, industrial soils, paving tiles and slabstone paving, compund floor paving. Finished surfaces for 5 12 15 minor purposes, e.g. warehouses, cellar. 3 Finished grounds, e.g. floor pavement serving as foundation for coverings. Coverings, tile coverings, PVC flooring and glued coverings. 2 4 10 12 15 5 Tolerances in mm 15 10 5 Line 2 Line 3 0 9 10 1 19 21 22 23 24 25 26 27 2 29 30 Distance between measuring points in m 5 Intermediate values are to be taken out the diagram and must be rounded-off to mm.

Page 1 Car ParkBoard PE/PH Code number 54.16.990-005 Version 03.13 of 6 : Longitudinal Pallets with Underfloor Drive () If the drive axis cannot be placed in front of a support the drive will be designed as underfloor drive. Precondition: Drive axis located in parking space axis; recess in floor. For arrangement of longitudinal pallets, see example. 2 x ParkBoard PH Conduit EN 40 (M40) with taut wire to nearest support or to wall 1015 1000 1015 Underfloor Drive () 25 49 37 75 Conduit EN 40 (M40) 50 Box for drive Box cast in concrete after Rail System Prior to floor pavement 6 7 Running rail 2 +0,5 2 +0,5 Top edge finished floor 176 (6) 49 ca.4 Filled up with rails packed up max.5 In recess 6 7 Running rail 250 () ca.4 On finished floor 6 7 Running rail 0,5 +0,5 2 +0,5 Projection of the guide rail above top edge of finished floor is mandatory on both sides of the rail including the level for the drive! The rails are dowelled directly onto the top edge of the finished floor. Drill hole depth: approx. 9 cm. 6 7 We do not recommend mastic asphalt. Tolerances for the evenness of the carriageway must be strictly complied with in accordance with DIN (= German Industrial Standard) No. 12, chart 3, line 3. No expansion joints are permitted within the area of the rail system. in brackets for PE-245/PH-245.

ParkBoard PE/PH Code number 54.16.990-005 Version 03.13 of 6 Page 1 Car max. 1 % max. 1 % in this area the same level is necessary 260 (290) 7 7 Tolerances for the evenness of the carriageway must be strictly complied with in accordance with DIN (= German Industrial Standard) No. 12, chart 3, line 3. No expansion joints are permitted within the area of the rail system. in brackets for PE-245/PH-245. Accessing standard parking spaces (for example No. 6) 21 Operating element for ParkBoard 21 Operating element for ParkBoard 21 If ParkBoard 21 is empty: passing of ParkBoard possible If ParkBoard 21 is occupied: press corresponding pushbutton for no. 21 on operating element. Pallets and 21 are moved together automatically, and parking spaces 6 (and 7) become free. Accessing the ParkBoard spaces 21 with ParkBoard PE. To access parking space no. both ParkBoard and 21 are moved in a way that the required driving lane is created. with ParkBoard PH. Direction of driving Exit to driving lane ParkBoard PE at end of driving lane 515 500 500 750 500 500 515 500 500 21 21 21 Unfavourable! Parking spaces 1, 2, 11, 12 can only be accessed unfavourably since both driving and turning range are strongly restricted. Dislocated parking spaces Solution: Dislocate support or drive. Driving and turning range for parking spaces 1, 2, 11, 12 are improved! Solution: Use of one ParkBoard PH. Driving and turning range for parking spaces 1, 2, 11, 12 are improved! 1 2 3 4 5 1 2 3 4 5 Extension (max. 1 m) 1 2 3 4 5 11 12 13 14 15 Not possible! Parking space 12 cannot be accessed if parking space is occupied. Reason: Axes of opposite parking spaces are offset. 11 12 13 14 15 Makeshift: One sided extension for ParkBoard. 11 12 13 14 15 Makeshift: Moving drive (Drive D). Drive D on the ParkBoard allows longer travel path. Power supply via trailing cable. Special guide rail. Warning: ParkBoard not accessible within range of drive!

ParkBoard PE/PH Code number 54.16.990-005 Version 03.13 of 6 Page 1 Car supply / Control system The must provide a supply of 5 x 2,5 mm 2 (3 PH+N+PE) to the electric cabinet (larger systems may require larger cross sections). Proposals for position of control box and operating element are specified in the floor plans provided by KLAUS Multiparking. Range of application By default, the system can only be used for a fixed number of users. If different users use the system (e.g. short-time parkers in office buildings or hotels) the Multiparking system needs to be adjusted. If required, would you please contact us. Available documents maintenance offer/contract declaration of conformity Corrosion protection See separate sheet regarding corrosion protection. Environmental conditions Environmental conditions for the area of multiparking systems: Temperature range 10 to +40 C. Relative humidity 50% at a maximum outside temperature of +40 C. Building application documents According to LBO and GaVo (garage regulations) the Multiparking systems are subject to approval. We will provide the required building application documents. Operation Operation via operating element with automatic reset function (two pushbuttons for left/right movement). Care To avoid damages resulting from corrosion, make sure to follow our cleaning and care instructions and to provide good ventilation of your garage. CE Certification The systems offered correspond to DIN EN 14010 and the EC Machinery Directive 06/42/EG. Palettenkonstruktion Noise emission Ball bearing of the rollers provide a low sound level. On block opration ParkBoards must only be operated on block if the operator s stand is not more than 10 m from the platform edges that are to be operated on block, and if it is installed at least 1.60 m above garage floor.

Page 1 Car ParkBoard PE/PH Code number 54.16.990-005 Version 03.13 Numbering of parking spaces Consecutive numbering of stationary parking spaces and longitudinal shifting ParkBoards. Building services Any required lighting, ventilation, fire extinguishing and fire alarm systems as well as clarification and compliance with the relevant regulatory requirements. supply to the control box Power supply: three phase 230/400 V/50 Hz with neutral and ground wire (other voltage network, voltage or frequency are possible after the technical checking by us). Main fuse: 3 x fuse 10 A (slow) or circuit breaker 3 x 10 A (trigger characteristic K or C). For 5 ParkBoards and more: 3 x fuse 16 A (slow) or circuit breaker 3 x 16 A (trigger characteristic K or C). Supply line 5 x 2.5 mm 2 to the main cabinet, depending on line layout, line length or system size a larger cross sections may be required. DIN VDE 0100 and other relevant local standards must be observed The supply line to the main cabinet must be provided during. The functionality can be monitored on site by our fitters together with the electrician. If this cannot be done during for some reason for which the is responsible, the must commission an electrician at their own expense and risk. General description Multiparking system for parking 1 or 2 vehicles per ParkBoard. are in accordance with the respective underlying height and width dimensions. ParkBoards, which can be moved lengthwise are installed in the driving lane of underground garages. These parking pallets make it possible to achieve additional parking spaces in the driving lane, which is generally only used for maneuvering vehicles. The ParkBoards can be driven on if vacant, or moved if occupied by a car when accessing parking spaces located in the back. This operation uses dead man s control safety mechanism. Therefore, the operating elements are generally mounted to the opposite supports and the ParkBoards and parking spaces arranged controller can be seen. Operating instructions are permanently mounted to each operating station in a clearly visible location. These ParkBoards are available in the following designs: ParkBoard PE for 1 car ParkBoard PH for 2 cars in a row ParkBoard consisting of: Sloped steel frames with supported low-noise track and guide rollers Cross members Platform base sections (cover plates) Positioning aid Various small parts etc. ParkBoard height approx. 9,5 cm above finished floor Above-floor drive: Base plate mounted to the ground with geared motor Limit switch and housing The housing also serves as safety mechanism. The load transmission is carried out via a high-tension chain located in a U-profile which is open facing outwards. This chain is looped around two chain wheels and driven motor. Marking Any additional yellow-black markings on the platform edges according to ISO 364. of 6 Main switch One lockable main switch coresponding to EN 604-1, 5.3.2 a), b) or c) and 10.7.4 mounted in the supply line per main cabinet. The main switch is to be mounted directly next to the main cabinet. Floor / Rails Flooring structure in accordance with our instructions, please see page 2 and 3 (recesses, rail systems). Recesses, for the evenness of the driving lane must adhere to DIN 12, sheet 3, line 3. Stuffing of rail system with cement floor for the whole length. Bringing in of floor pavement. Conduit M40 with taut wire to underfloor drive. If the following are not included in the quotation, they will also have to be provided / paid for : Costs for final technical approval by an authorized body Main switch Underfloor drive:: This drive unit is mounted in a floor recess which must be built by the. This drive consists of: 1 geared motor Chain wheels Limit switch Fully mounted in a stable underfloor housing with cover The load transmission is carried out identically to the "above-floor drive" Moving drive (special): Drive unit mounted to the ParkBoard Power is supplied via a drag-line cable (or via contact lines in exceptional cases) The load transmission is carried out using a chain, which is inlaid in a special rail (double rail) consisting of: Two rails mounted on the floor The rails protrude 5 mm above finished floor The rail on the entrance side is the guide rail and ensures safe guiding when shifting the ParkBoards. equipment consisting of: Operating device with 2 buttons (right/left) Emergency Stop Control box Blinking lights Various cables with accessoriesr Control system The ParkBoards are operated using a push-button with corresponding direction definition in hold-to-run control Limit switches stop the ParkBoards when the maximum movement distance has been reached Warning lights blink during movement The electrical wiring originates in the control box We reserve the right to change this specification without further notice KLAUS Multiparking reserves the right in the course of technical progress to use newer or other technologies, systems, processes, procedures or standards in the fulfillment of their obligations other than those originally offered provided the derives no disadvantage from their so doing.