SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

Similar documents
HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

Solenoid Actuated Diesel Engine Air Shut Down Valves

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

Diesel Engine Shutdown Valves

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

MVX-Series Diesel Engine Air Shut Down Valves

Diesel Engine Shutdown Valve

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

SELECTION, APPLICATION AND MAINTENANCE

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

Diesel Engine Shutdown System

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Flameproof Alternators

SELECTION, APPLICATION AND MAINTENANCE

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

SELECTION, APPLICATION AND MAINTENANCE

E-M Series. Combined Manual and Automatic Engine Overspeed Shut Down Valves

System Selection Guide

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

Automatic Fuel Shut Down Valves

Air Intake Shut-off Valve

E Series. Automatic Engine Overspeed Shut Down Valves

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

Diesel Engine Air Intake Shutoff Valves

Intake Air Shut-off Valve

Flameproof Alternator

Self-Exciting Flameproof Alternator

by AMOT World class diesel engine safety solutions Product Selection Guide

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Flameproof Alternator

Flameproof Alternator

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Pressure and Temperature Switches

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

Pilot Operated 2-Way Gas Valves

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Metal Particle Detector

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

Pneumatic Indicating Relay

Optimise your temperature control

2-Way Temperature Sensing Valves

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

Model H. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations

Thermostatic Control Valves

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50203 AIR INTAKE SHUT-OFF VALVES APPLICATION DODGE 5.9L CUMMINS.

Is the heart of your engine protected?

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

PH2 AIR INTAKE EMERGENCY SHUT-OFF VALVES. APPLICATION C ½ DODGE 6.7L CUMMINS C DODGE 6.

3-Way Temperature Control Valve

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

E1186X Breather Kit. For Yanmar L48N Engines

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50207 AIR INTAKE SHUT-OFF VALVES APPLICATION FORD 6.7L POWERSTROKE.

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

Model E. Thermostatic Control Valves. Typical applications

Thermostatic Control Valve

Metal Particle Detector

Thermostatic Control Valve

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

II 2GD. xxxx. Westlock 2200 Series Quantum - ATEX certified Installation & Operating Instructions

Installation, Operation and Maintenance Manual DOC.IOM.MO.E October MO-Series Manual Override Gearboxes

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

DOUBLE GATE KNIFE GATE VALVE

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Series 500. Liquid Level Transmitters. Instruction Manual

Installation Instructions

Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black Tekn gas Black

BI-DIRECTIONAL KNIFE GATE VALVE

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Rosemount 485 Annubar Pak-Lok Assembly

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

NELES BO SERIES BUTTERFLY VALVE FOR RECOVERY OF OXYGEN IN VACUUM PRESSURE SWING ADSORPTION (VPSA) PLANTS

289 Series Relief Valves

With regards to safety it is not necessary to check for correct operation.

SERIES 2000 GAS SAFETY SHUT OFF VALVE

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

M1/M2 POCKET FEEDER. Compact design DESIGN FEATURES. Special ball and seat design. Large ball pocket capacity. Automatic cycling

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

RUBBER SLEEVE KNIFE GATE VALVE

THROUGH CONDUIT KNIFE GATE VALVE. OBX 09/11 2nd EDITION Revision 1 Reserves the right to change specifications without notice

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

RUBBER SLEEVE KNIFE GATE VALVE

MAPAG Butterfly valve - Type BK For cryogenic applications. Installation, Maintenance and Operating Instructions

M High Performance Power Transmission Couplings

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

Sepehr Hydraulic Asia

DOUBLE GATE KNIFE GATE VALVE. OBX 09/09 8th EDITION Reserves the right to change specifications without notice

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

TOP SMART intelligent position monitor:

type 122a three-way Switching Valve

Rosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016

Transcription:

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop) Selection, Application and Maintenance Valve Numbers SVX-340 SVX-350 SVX-341 SVX-351 SVX-540 SVX-550 SVX-541 SVX-551

DESCRIPTION Diesel Engine Shutdown Valves - SVX 340-551 12 and 24 vdc solenoid powered diesel engine shut down valves based on the standard 3 and 5 slimfit Chalwyn butterfly valves. Designed for applications where no suitable electrical supply is available during engine start up and a manual override facility is therefore required. Once the protected engine is running and electrical power is available the valve is latched in the open (run) position by the solenoid until power is lost or until the manual emergency shut down facility is operated. These valves are available in flange mounted form or can be supplied fitted with hose adapters and/or a flametrap housing. Versions of these valves are available for both hazardous and non-hazardous area application. Valve bodies and discs are manufactured in corrosion resistant hard anodised aluminium with PTFE coating. The valve spindle is made from 316 grade stainless steel. Typical Valve Arrangement C2 (Max) C2 (Min) C1 Optional hose adaptors B B1 Solenoid supply cable A Manual start override/ emergency stop cable Solenoid Main Dimensions (mm) Illustration based on SVX-540 SVX-340 SVX-350 SVX-540 SVX-550 Valve Type SVX-341 SVX-351 SVX-541 SVX-551 Nominal Bore Diameter 76 (3 ) 127 (5 ) A mm 213.5 270 B mm 111.5 167.25 B1 mm 144 172 C1 mm 37.5 45.5 C2 minimum & maximum 82.5 to 112.5 101.9 to 157.5 page 2

Diesel Engine Shutdown Valves - SVX 340-551 The Chalwyn solenoid SSX-103 and SSX-104 built into the hazardous area valves type SVX-340, SVX-341, SVX-540 and SVX-541 are marked as follows: CHALWYN by AMOT Bury St Edmunds, ENGLAND TYPE SSX-103 EEx e II T4 (Tamb = -30 c to +50 c) 0518 11 2 G D IP66 SIRA99ATEX3186X SERIAL NO. xxxxx 12 VOLTS, HOLD 1.1A CHALWYN by AMOT Bury St Edmunds, ENGLAND TYPE SSX-104 EEx e II T4 (Tamb = -30 c to +50 c) 0518 11 2 G D IP66 SIRA99ATEX3186X SERIAL NO. xxxxx 24 VOLTS, HOLD 0.5A IMPORTANT NOTES: SOLENOID TYPE SSX-103 and SSX-104 Araldite epoxy adhesive and an elastomeric cable seal are used in the construction of these solenoids. The characteristics of these materials with regard to attack by aggressive substances shall be taken into account when installing or using the product in a hazardous area. Solenoids SSX-103 and SSX-104 must not be mounted or installed in such a way that the effective ambient temperature exceeds 50 c. page 3

SELECTION Diesel Engine Shutdown Valves - SVX 340-551 Valve types SVX-340, SVX-341, SVX-540 and SVX-541 are suitable for installation in Zone l, Group IIB, T4 hazardous areas. Valve types SVX-350, SVX-351, SVX-550 and SVX-551 are not suitable for hazardous area application. Determine the size and position of the SVX valve to be installed. Check that the electrical cable can be routed away without risk of damage. Alternative entry points are available for the cable (check with Chalwyn). Identify a suitable position for the start override lever (RLX-100) which is both convenient for operation and permits a reasonably straight run for the start override cable to the SVX valve. Start override cables are available from stock in the lengths shown below. Other sizes available on request. SVX valves are designed for mounting between flanges but can also be supplied complete with fitted hose adaptors selected from the table below. Hose Adaptor Options 76mm (3 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-320 38 ( 1 1 / 2 ) HAX-322 44.5 (1 3 / 4 ) HAX-301 51 (2) HAX-303 57 (2 1 / 4 ) HAX-304 60 (2 3 / 8 ) HAX-305 63.5 (2 1 / 2 ) HAX-306 67 (2 5 / 8 ) HAX-307 70 (2 3 / 4 ) HAX-309 76 (3) HAX-312 82.5 (3 1 / 4 ) HAX-314 89 (3 1 / 2 ) HAX-319 102 (4) 127mm (5 ) Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-501 89 (3 1 / 2 ) HAX-503 95 (3 3 / 4 ) HAX-505 102 (4) HAX-507 108 (4 1 / 4 ) HAX-509 114 (4 1 / 2 ) HAX-511 121 (4 3 / 4 ) HAX-513 127 (5) HAX-518 140 (5 1 / 2 ) HAX-523 152 (6) Override Cable Options Cable Identity Cable Length CHW-100 1.0m CHW-200 2.0m CHW-250 2.5m CHW-300 3.0m page 4

Diesel Engine Shutdown Valves - SVX 340-551 INSTALLATION (Mechanical) In the case of a naturally aspirated engine, the Chalwyn SVX shut down valve should generally be fitted as close to the engine air intake manifold as possible. If an intake flame trap is also fitted, the SVX valve must be installed upstream (air cleaner side) of the flame trap. To avoid excessively high temperatures at the SVX valve when fitted to a turbocharged engine, it is recommended the valve is fitted either upstream of the turbocharger or downstream of the intercooler (if fitted). Again, if an air intake flametrap is also fitted, the valve must be installed upstream of the flametrap. SVX intake shut down valves may be installed either horizontally or vertically. Air flow may be in either direction. Position the SVX valve such that the electrical and mechanical cables can be routed away clear of any hot or sharp surface. If hose adaptors are used, the mating hose should be of a re-inforced type, provide adequate support for the valve and prevent excessive vibration. If necessary, additional support brackets mounted from the engine should be considered. Particular care must be taken to ensure the integrity of the intake pipework between the Chalwyn valve and intake manifold. Ideally metal pipework should be used and any gaps kept as short as possible, (taking into account any relative movement) and closed by reinforced hose. The possibility of a hose collapse on closure of the shut down valve should be avoided. Any engine crankcase breather connections into the intake system between the SVX valve and engine, or any internal crankcase breather arrangement venting directly into the engine intake ports must be sealed and replaced by an external breather system venting either to atmosphere or to the intake system upstream of the shut down valve. External breather system kits for various engine types are available from Chalwyn. The lever assembly RLX-100 should be mounted using the three through holes provided in the assembly. It must be positioned where convenient for operation and also to permit a reasonably straight run without tight bends for the override cable between the lever assembly and valve. The lever RLX-100 is sprung towards the valve closed position. With no power applied the SVX valve is also sprung to the closed position. With both the RLX-100 and SVX valve in the closed position fit the override cable. Adjust cable and tighten the locknuts such that with the SVX valve fully closed, the outboard end of the lever RLX-100 is positioned about 5 to 10mm from its central stop (closed) position. When the RLX-100 is exercised over its operating stroke the distinct sound of the SVX valve closing should now be audible. page 5

Diesel Engine Shutdown Valves - SVX 340-551 INSTALLATION (Electrical) Valve Type Specification Power Rating Cable Colour SVX-340 SVX-540 SVX-341 SVX-541 SVX-350 SVX-550 SVX-351 SVX-551 EExe II T4 EExe II T4 Non Flameproof Non Flameproof V A Hold Common 12 24 12 24 1.1 0.5 1.1 0.5 Brown Brown Red Red Blue Blue Black Black Subject to the valve type, either a 12volt or 24volt supply is required to energise the solenoid to latch the valve in the run (open) position (see above). When de-energised the SVX valve will always return to the closed position except when overridden by the manual start override. The electrical supply to the solenoid must be arranged/operated such that power is not applied to the SVX valve until it is held open by the manual start override. In the case of the hazardous area valves SVX-340, SVX-341, SVX-540 and SVX-541 the outer braiding of the supply cable must be earthed at the supply end. The solenoid end cover should be earthed using the earth tag of the cable gland. The electrical supply system for the hazardous area type valves must be suitable for the hazardous environment of the application and appropriate glanding used at the supply end of the solenoid cable. Clamping devices should be fitted to the cable as close as possible to the glands. 1. Prior to starting engine use the start override lever to open the SVX valve to the run position. 2. Continue to hold the valve in the run position whilst starting and running up engine. 3. As soon as the appropriate electrical supply is available at the SVX solenoid, the valve will latch in the run position. The override lever may then be released and should remain in the run position. 4. If at any time the electrical supply to the solenoid is lost the SVX valve will close and stop the engine. 5. To carry out a manual emergency stop, move the start override lever from the run position back to the stop (valve closed) position. Note. Only apply power to the SVX valve solenoid after the SVX valve has first been opened by the start override control. page 6

MAINTENANCE MONTHLY: Diesel Engine Shutdown Valves - SVX 340-551 Check that the fasteners locating the SVX valve and any associated intake system or support bracket fasteners are tight. Check that any flexible hoses in the air intake system between the SVX valve and engine are free from damage and suitable for further service. Check that the electrical cable to the valve is properly clamped/supported and free from damage. Start engine. Run at or just above low idle speed. Carry out a manual emergency stop. The engine should stop within a few seconds of moving the start override lever from the run to stop position. If not: a) Check then engine air intake system for freedom from leaks. b) Check that the start override cable is properly adjusted. Should these checks not resolve the problem return the SVX valve to Chalwyn for inspection. page 7

Americas Asia Pacific Europe, Middle East and Africa AMOT - USA Tel: +1 281 940 1800 Fax: +1 713 559 9419 info@amotusa.com AMOT - China Tel: +86 (0)21 6279 7700 Fax: +86 (0)21 5237 8560 shanghai@amot.com AMOT - UK Tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 info@amot.com Roda Deaco by AMOT - Canada Tel: +1 780 465 4429 Fax: +1 780 469 6275 info@rodadeaco.com AMOT Singapore Tel: +65 6408 6265 Fax: +65 6408 6266 singapore@amot.com AMOT - Germany Tel: +49 (0)40 8537 1298 Fax: +49 (0)40 8537 1331 germany@amot.com AMOT - Russia Tel: +7 495 617 12 96 Fax: +7 495 913 97 65 russia@amot.com DS-MVX301-803-ShutdownValves-CE217-0712-rev1 www.chalwyn.com by AMOT