Diesel Engine Shutdown Valve

Similar documents
SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

MVX-Series Diesel Engine Air Shut Down Valves

Diesel Engine Shutdown Valves

Solenoid Actuated Diesel Engine Air Shut Down Valves

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

Diesel Engine Shutdown System

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

Air Intake Shut-off Valve

System Selection Guide

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

Automatic Fuel Shut Down Valves

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

Diesel Engine Air Intake Shutoff Valves

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

E-M Series. Combined Manual and Automatic Engine Overspeed Shut Down Valves

SELECTION, APPLICATION AND MAINTENANCE

E Series. Automatic Engine Overspeed Shut Down Valves

by AMOT World class diesel engine safety solutions Product Selection Guide

Flameproof Alternators

SELECTION, APPLICATION AND MAINTENANCE

Intake Air Shut-off Valve

SELECTION, APPLICATION AND MAINTENANCE

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50203 AIR INTAKE SHUT-OFF VALVES APPLICATION DODGE 5.9L CUMMINS.

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

Pilot Operated 2-Way Gas Valves

PH2 AIR INTAKE EMERGENCY SHUT-OFF VALVES. APPLICATION C ½ DODGE 6.7L CUMMINS C DODGE 6.

Optimise your temperature control

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50207 AIR INTAKE SHUT-OFF VALVES APPLICATION FORD 6.7L POWERSTROKE.

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

Pneumatic Indicating Relay

Pressure and Temperature Switches

Metal Particle Detector

2-Way Temperature Sensing Valves

Flameproof Alternator

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

Model H. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations

Flameproof Alternator

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

Thermostatic Control Valves

Self-Exciting Flameproof Alternator

Is the heart of your engine protected?

3-Way Temperature Control Valve

E1186X Breather Kit. For Yanmar L48N Engines

1.75" to 2.5" sizes available Compact and lightweight Low maintenance, pull cable valve

Flameproof Alternator

3 Edition Product brochure GB AGA

Bulk Liquid Filtration

Thermostatic Control Valve

RUBBER SLEEVE KNIFE GATE VALVE

OBSOLETE DOCUMENT. 167D Series Switching Valves. Bulletin 71.7:167D. Introduction. Features

Type 310A-32A Pressure Reducing Regulator

RUBBER SLEEVE KNIFE GATE VALVE

Thermostatic Control Valve

Installation, Operation. IOM 1540 Rev. 1. Page 1 of

167D Series Switching Valves

SERIES 835 PROCESS-RATED CLASS 150 WAFER-SPHERE HIGH-PERFORMANCE BUTTERFLY VALVES

Installation, Operation and Maintenance Manual DOC.IOM.MO.E October MO-Series Manual Override Gearboxes

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

type 122a three-way Switching Valve

MAPAG Butterfly valve - Type BK For cryogenic applications. Installation, Maintenance and Operating Instructions

Model E. Thermostatic Control Valves. Typical applications

reliable actuators to

C40008 & C40009 EXHAUST BRAKES

Series 500. Liquid Level Transmitters. Instruction Manual

Y690A Series Pressure Reducing Regulators

THROUGH CONDUIT KNIFE GATE VALVE. OBX 09/11 2nd EDITION Revision 1 Reserves the right to change specifications without notice

Tightness control TC. Product brochure GB Edition 12.10

Instruction Manual. Back Pressure Regulator (Low Shear ¾ ) Bar Pilot Control

PWP Series - PressureGuard Wellhead Protection

2009 PCED Gasoline Engines SECTION 1: Description and Operation. Intake Air System

Shafer RV-Series Rotary Vane Valve Actuators Valve Operating Systems for Critical Pipeline Applications

RC 200 designs. Pressure ranges RC 200-DA: 2-10 bar / psi RC 200-SR: 2-10 bar / psi

4 Redundant Control System

Inspection, Testing, and Maintenance Fire Pumps NFPA 25, Chapter 8 as amended by CCR, Title 19 Page 1 of 8

TOP SMART intelligent position monitor:

Valves with a difference. Thin Wafer. Check Valves DVC INTERNATIONAL

M1/M2 POCKET FEEDER. Compact design DESIGN FEATURES. Special ball and seat design. Large ball pocket capacity. Automatic cycling

Series 900 Minifolds. Aluminium Air Distribution Manifolds. Manifolds & Minifolds. Technical Specifications. hnl-uk.com. Series 900 Minifolds

BERMAD Irrigation. High Performance Plastic Valves. 100 Series - Water Control Solutions

FORGED STAINLESS STEEL Rack And Pinion Actuator S Series

289 Series Relief Valves

Transcription:

Diesel Engine Shutdown Valve Models PVX-300, 301 PVX-500, 501 PVX-800, 801 (Pneumatically Actuated) Typical Applications PVX-300, PVX-500, PVX-800 Failsafe application to meet EU ATEX 94/9/EC defined hazardous areas Zone 1 and 2 applications to EN 1834 engine safety standards US offshore engines to Class 1 Div 2 and Div 1 safety standards International offshore platform engine installations PVX-301, PVX 501, PVX 801 Petrochemical and LNG refineries All international areas where non-failsafe is permitted US offshore BOEMRE 2011 Safety Standards Zone 2 fire pump engine offshore applications Vehicles with air brakes Fuel tankers Emergency vehicles Vacuum trucks Key benefits Simple direct air pressure operation Build options to either open or close on the application of air pressure Automatic reset on loss of air pressure Valve status indicator Combination of body sizes and hose adaptors to suit air intake diameters from 38 mm (1 1/2 inches) to 203 mm (8 inches) www.chalwyn.com

page 2

Description Pneumatically operated diesel engine air intake closure valves based on the standard Chalwyn slimfit 3, 5 and 8 bore butterfly valves with variants for both hazardous and non-hazardous areas. Available in basic flange mounted form or supplied fitted with hose adaptors or an integral flame trap housing (3 valves only). Body and disc manufactured in corrosion resistant hard anodised aluminium with PTFE coating. Suitable for salt air offshore environments. Typical PVX Valve Arrangement Air Actuator Position indicator 1/8 BSP Female Air Connection Port Vent Optional Hose Adaptor A C 1 B C 2 (min) C 2 (max) Main Dimensions (mm) Valve Type PVX-300 PVX-301 PVX-500 PVX-501 PVX-800 PVX-801 Nominal Bore Diameter 76 (3 ) 127 (5 ) 203 (8 ) A mm 208.0 257.0 354.5 B mm 111.5 167.0 257.0 * If accurate C 2 measurement is required please contact Chalwyn. C 1 mm 37.5 45.5 56.0 C 2 min & max * 82.5 to 112.5 102.0 to 157.5 136.5 to 185.5 page 3

Selection Determine the size and position of the PVX valve to be installed. Within the various constraints imposed in the application the valve should be as generously sized as possible. A pneumatic supply must be available to operate this valve type. PVX-300, PVX-500 and PVX-800 valves open on the application of air pressure. The fail safe mode of operation of the PVX-300, PVX-500 and PVX-800 models makes them suitable for use in zone 1 hazardous areas. PVX-301, PVX-501 and PVX-801 close on the application of air pressure. This type of valve and Chalwyn control system is recommended for larger vehicles that have air brakes (see page 7). The actuators fitted to these valves are suitable for an operating temperature range between -20 C (-4 F) and 120 C (248 F) and a maximum applied pressure of 8 bar (120 psi). Ideally if hose adaptors or an integral intake flame trap housing is to be used, these should be identified and ordered from Chalwyn at the same time as the basic PVX valve. Hose Adaptor Options 76mm (3 ) PVX-30* Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-320 38 (1 1 / 2 ) HAX-322 44 (1 3 / 4 ) HAX-301 51 (2) HAX-303 57 (2 1 / 4 ) HAX-304 60 (2 3 / 8 ) HAX-305 63.5 (2 1 / 2 ) HAX-306 67 (2 5 / 8 ) HAX-307 70 (2 3 / 4 ) HAX-309 76 (3) HAX-312 82 (3 1 / 4 ) HAX-314 89 (3 1 / 2 ) HAX-319 102 (4) 127mm (5 ) PVX-50* Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-501 89 (3 1 / 2 ) HAX-503 95 (3 3 / 4 ) HAX-505 102 (4) HAX-507 108 (4 1 / 4 ) HAX-509 114 (4 1 / 2 ) HAX-511 121 (4 3 / 4 ) HAX-513 127 (5) HAX-518 140 (5 1 / 2 ) HAX-523 152 (6) 203mm (8 ) PVX-80* Bore Valves Adaptor To Suit Hose Bore Part Number mm (inches) HAX-807 178 (7) HAX-808 203 (8) page 4

Installation 1. In the case of a naturally aspirated engine the Chalwyn PVX shut down valve should generally be fitted as close to the engine air intake manifold as possible. If an air intake flame trap is also fitted, the PVX valve must be installed upstream (air cleaner side) of the flame trap. 2. To avoid excessively high intake air temperatures at the PVX valve when fitted to a turbocharged engine, it may be necessary to fit the PVX valve either upstream of the turbocharger or downstream of the intercooler (if fitted). Again, if an air intake flametrap is also fitted, the valve must be installed upstream of the flametrap. 3. Where more than one PVX valve is fitted to an engine, as in the case of an engine with multiple intake pipes, a common pneumatic supply to the valves should be used to ensure that all valves close simultaneously. A balance pipe arrangement should also be incorporated to connect the separate intake pipes together downstream (engine side) of the shut down valves. Typically balance pipe diameters should be about 30% of the diameter of the intake pipes. 4. The PVX valve may be installed at any convenient angle. 5. If hose adaptors are used, the mating hose should be of a reinforced or strong silicone type, provide adequate support for the valve and prevent excessive vibration. If necessary, additional support brackets mounted from the engine should be considered. 8. Connect the intake port of the actuator to the air supply using suitable pipe and 1/8 BSP connector (male, parallel). 9. A fitting kit of several connectors with suitable BSP threads is available from Chalwyn as part SKA-100. This includes flexible hose. 10. For further installation schematics and details of electric systems to operate PVX-301 or PVX-501 on vehicles, please see System Selection Guide at www.dieselsafety.com/technical downloads. (Some detail of this is shown on page 7). Notes Maximum temperature of the engine intake air at the PVX valve not to exceed 150 C. Alternative types of air actuated valves are available from Chalwyn - see brochures CE231, CE236 and CE237. If automatic diesel fuel shut down is required in combination with air intake shut down a Chalwyn FSX-200 fuel shut down valve should also be specified (brochure CE226). Also order chosen PVX valve with Y suffix and an FKX-300 fitting kit for easiest connections to the FSX-200. 6. Particular care must be taken to ensure the integrity of the intake pipework between the Chalwyn valve and intake manifold. Ideally metal pipework should be used and any gaps kept as short as possible, (taking into account any relative movement) and closed by reinforced hose. The possibility of a hose collapse on closure of the shut down valve must be avoided. 7. Any engine crankcase breather connections into the intake system between the PVX valve and engine, or any internal crankcase breather arrangement venting directly into the engine intake ports must be sealed and replaced by an external breather system venting either to atmosphere or to the intake system upstream of the shut down valve. External breather system kits for various engine types are available from Chalwyn. page 5

Operation PVX-300, PVX-500 and PVX-800 Prior to engine start, air pressure must be applied to these failsafe PVX valves to open to the engine run position. (Note, the external yellow indicator on the valve shows the position of the valve disc). Air pressure must be maintained between 4 and 8 bar to hold the intake valve fully open whilst the engine runs. To carry out an emergency engine stop by closing the air intake valve, close down the air supply and vent the supply line. The valve will fully close once the air supply pressure at the valve falls below 2 bar. NOTE: The pneumatic supply to the valve must be clean and dry. PVX-301, PVX-501 and PVX-801 With no air pressure applied to these PVX valves they will be naturally sprung fully open and the engine may be run. To carry out an emergency stop apply an air pressure of 4 to 8 bar to close the intake shut down valve. The supply pressure must be vented before attempting to re-start the engine. This venting will happen automatically and at a controlled slow speed when kit SKA-100 and 24 Volt Solenoid SVA-200 are installed and the outlet vent device is adjusted correctly. The PVX valve will then return to open position allowing the engine to run. Maintenance Weekly: Exercise the valve by applying and venting the control air supply pressure. Check by observing the external position indicator that the valve is freely moving between the open and closed positions. For vehicle installations this can be done by holding the manual toggle electric switch as shown in the System Selection Guide schematic on page 11. The PVX-301/501 will reset to open automatically when the switch is released. Monthly: Check that the fasteners locating the PVX valve and any associated intake system or support bracket fasteners are securely tightened. Check that any flexible hoses in the engine intake system between the PVX valve and engine are free from damage and suitable for further service. Check that the air supply pipe to the PVX valve is properly supported, free from damage and the pipe fittings are tight. Run engine, preferably at low idle. Vent (or supply as appropriate) the control air pressure to the PVX valve and check that the engine stops within a few seconds. If not, check the engine air intake system for leaks. Should this not solve the problem remove the intake valve and return to Chalwyn for further investigation. page 6

Diesel Engine Shutdown Valve - PVX Control System Information Chalwyn has a broad array of fully automatic shutoff systems and manual shutoff systems. Common operating methods include electric, pneumatic, electric/pneumatic, mechanical, or combinations of these mechanisms. The Chalwyn System Selection Guide provides an overview of the most common types of systems used in applications today. The overview includes a description of the solution, a diagram of the components and includes the functional highlights of the components used in each solution. These overviews will provide the information required to help you determine the best type of solution for your application. Download the brochure at www.dieselsafety.com/ technicaldownloads For further details of application of Chalwyn PVX*01 valves for vehicles requiring automatic shutdown of overspeed, please contact Chalwyn or your local distributor (www.dieselsafety.com/distributor). page 7

Americas Asia Pacific Europe, Middle East and Africa AMOT - USA Tel: +1 281 940 1800 Fax: +1 713 559 9419 info@amotusa.com Roda Deaco by AMOT - Canada Tel: +1 780 465 4429 Fax: +1 780 469 6275 info@rodadeaco.com AMOT - China Tel: +86 (0)21 6279 7700 Fax: +86 (0)21 5237 8560 shanghair@amot.com AMOT Singapore Tel: +65 6408 6265 Fax: +65 6408 6266 singapore@amot.com AMOT - UK Tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 info@amot.com AMOT - Germany Tel: +49 (0)40 8537 1298 Fax: +49 (0)40 8537 1331 germany@amot.com AMOT - Russia Tel: +7 495 617 12 96 Fax: +7 495 913 97 65 russia@amot.com DS-PVX-Shutdown Valve-CE224-0712-rev1 www.chalwyn.com by AMOT