D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

Similar documents
D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types)

SELECTION, APPLICATION AND MAINTENANCE

SELECTION, APPLICATION AND MAINTENANCE

D-Series Automatic Engine Overspeed Shut Down Valves (Mini Range)

D200 Spindle Type Automatic Engine Overspeed Air Intake Shut Down Valve (including Manual, Oil and Air Pressure Shut Down Control options)

MVX-Series Diesel Engine Air Shut Down Valves

HVX-Series Diesel Engine Shut Down Valves (Oil Pressure Latched Types with Manual Start Override/Emergency Stop)

Diesel Engine Shutdown Valves

SVX-Series Solenoid Actuated Diesel Air Shut Down Valves

SVX-Series Diesel Engine Shut Down Valves (Solenoid Latched Types with Manual Start Override/Emergency Stop)

Diesel Engine Shutdown Valve

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

Solenoid Actuated Diesel Engine Air Shut Down Valves

E-M Series. Combined Manual and Automatic Engine Overspeed Shut Down Valves

E Series. Automatic Engine Overspeed Shut Down Valves

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Stop Types)

Diesel Engine Safety Solutions. Automatic Engine Overspeed Shut Down Valves - D Series

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run Types for Non-Hazardous Areas)

FS2 Valves. Solenoid Powered to Close / Auto Reset Butterfly Valves

FS3 Valves. Solenoid Powered to Open / Spring to Close (failsafe)

Diesel Engine Shutdown System

SVX-Series Solenoid Actuated Diesel Engine Air Shut Down Valves (Energised to Run, Hazardous Area Types without Manual Override)

World class manufacturer of safety solutions SYSTEM SELECTION GUIDE. Safety solutions for vehicles and machines working in petrochemical plants

by AMOT World class diesel engine safety solutions Automatic Engine Overspeed Shut Down Valves - D Series

Air Intake Shut-off Valve

System Selection Guide

Flameproof Alternators

Automatic Fuel Shut Down Valves

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDB3 Compact Butterfly Valve. by AMOT. Overview. Typical Applications

Diesel Engine Air Intake Shutoff Valves

Intake Air Shut-off Valve

Flameproof Alternator

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Pilot Operated 2-Way Gas Valves

SELECTION, APPLICATION AND MAINTENANCE

Optimise your temperature control

PH1 AIR INTAKE EMERGENCY SHUT-OFF VALVE PULL CABLE ACTUATION.

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

PH2 C50219A AIR INTAKE SHUT-OFF VALVE. T800 KENWORTH / ISX ENGINE WITH POWERGUARD SMART OVERSPEED LIMITER

2-Way Temperature Sensing Valves

Is the heart of your engine protected?

Flameproof Alternator

Metal Particle Detector

Self-Exciting Flameproof Alternator

Flameproof Alternator

by AMOT World class diesel engine safety solutions Product Selection Guide

PH3 AIR INTAKE EMERGENCY SHUT-OFF VALVE WITH POWERGUARD SMART OVERSPEED LIMITER. Generic PH3 Truck Shut-Off Valve Kit.

Pneumatic Indicating Relay

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

Pressure and Temperature Switches

3-Way Temperature Control Valve

C50254A PH3 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS WITH POWERGUARD SMART OVERSPEED LIMITER

Model J. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations available

PH2 POWERHALT AIR INTAKE SHUT-OFF VALVE C50201A ½ DODGE 6.7L CUMMINS C50202A DODGE 6.

Model H. Thermostatic Control Valves. Typical applications. Key benefits. Key features. Accreditations

Thermostatic Control Valves

1 Engine and peripherals

AIR INTAKE EMERGENCY SHUT-OFF VALVE C50203 AIR INTAKE SHUT-OFF VALVES APPLICATION DODGE 5.9L CUMMINS.

E1186X Breather Kit. For Yanmar L48N Engines

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Installation Manual. Model T675A Engine Brakes. For Mack 6 Cylinder, 2 valve Head ENDT-673, 675, 676 & E6 Series Engines.

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

Thermostatic Valve. Filterstat - Model FJA. Typical applications. Key features and benefits. Mixing Diverting

Type 289P Pilot-Operated Relief Valve

PH2 AIR INTAKE EMERGENCY SHUT-OFF VALVES. APPLICATION C ½ DODGE 6.7L CUMMINS C DODGE 6.

Removal and Installation of Fuel Injection Pumps

type 122a three-way Switching Valve

EXPLOSION PROOF. Diesel Engines For Hazardous Areas

400 Series 404D-22TA Industrial Open Power Unit 46.2 kw / rpm

ATB Series - Integral Throttle Body Actuators

Type 289P Pilot-Operated Relief Valve

AIR INTAKE EMERGENCY SHUT-OFF VALVE PH2 C50204 AIR INTAKE SHUT-OFF VALVE DODGE 6.7L CUMMINS.

Bettis GC01-Extension Series Extension Pneumatic Double-Acting & Spring-Return Actuator Torque Chart Metric

Y690A Series Pressure Reducing Regulators

Installation Instructions

SI unit. Supplementary unit unit. in Ib Ibf Ibfft psi qt(us) F. kg N Nm bar 1 C

Thermostatic Control Valve

Type 310A-32A Pressure Reducing Regulator

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Operating Instructions M3 and M3HW Jackscrew Manual Override. Service Instructions Rev. D October 2014

Bettis Nuclear Series Actuators. Operation and Maintenance Manual VA Rev. E June 2014

Oregon Fuel Injection

Thermostatic Control Valve

400 Series 403D-15 Industrial Open Power Unit 24.2 kw / 32.5 hp

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

Product Information ROSS CONTROLS

Mini-Pak TM 6. Industry s most advanced additive injection system for load racks with multiple injection points.

Bettis G01-Extension Series Extension Pneumatic Double-Acting & Spring-Return Actuator Torque Chart Imperial

Installation Instructions


TROUBLESHOOTING FLOW CHARTS

Installation Instructions

400 Series 404D-22 Industrial Open Power Unit 37 kw / rpm

Control Valves. Type HP-10, 10,000 PSI. User Manual. RCV-UM EN-01 (August 2014)

Bettis GH-Series Pneumatic Spring-Return Actuator Torque Chart Imperial

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

289 Series Relief Valves

M High Performance Power Transmission Couplings

SEries 41 check valve installation, operation & maintenance manual

Petrol Driven Water Pump. Model No. CD1-1 Part No OPERATING & MAINTENANCE INSTRUCTIONS

Transcription:

D-Series Automatic Engine Overspeed Shut Down Valves (Bendix Types) Selection, Application and Maintenance Valve Numbers D45 D51 D57 D64 D70 D80 CE204 (12) D series

DESCRIPTION A range of spring loaded poppet valves designed to automatically stop an engine by closing down the air intake should excessive overspeeding occur. Build options are available to suit virtually all popular combinations of engine ratings and air intake pipe size. The closing force on the valve is provided by the intake air flow passing through. As the air flow increases, the closing force builds up. This is resisted by the valve spring, the pre-load on which is adjustable such that at a given air flow the resulting force overcomes the spring resistance and causes the valve to close. Once closed the valve will not reset to the open condition until the engine stops. This type of valve may be fitted to either naturally aspirated or turbocharged engines. It should be noted however that for a given valve setting the repeatability of the actual shut down speed has a greater scatter in the case of a turbocharged engine. However, unless for special reasons a precisely repeatable shut down speed is required, adequate protection from excessive overspeed and potential resulting damage is still achieved. The basic dimensions for this family of valves are tabulated below. Valve Type A mm B mm C mm WEIGHT Kg D45 D51 D57 D64 D70 D80 54.0 58.0 62.7 67.5 74.5 87.5 112 115 118 119 125 139 19 19 19 19 19* 19* 0.7 0.8 0.9 1.0 1.1 1.5 Outside diameter X is selected to suit the bore of the engine air intake hose see page 3 SELECTION. Dimensions marked * increase to 25mm for outside diameter X valves of 86mm or greater. Notes: * For smaller valve sizes see Chalwyn Mini Range valve data sheet CE 209. * For larger valve sizes see Spindle and D200 valve data sheets CE 205 and CE 231. * For integral air cleaner and manual shut down options see data sheets CE 206 and CE 207. 2 D SERIES -Bendix Types AUTOMATIC ENGINE OVERSPEED VALVES T: +44 (0)1284 715739 204 (12) Sales@chalwyn.co.uk

SELECTION Determine the rating of the engine to which the valve is to be fitted and whether or not turbocharged. Using the table below identify which valve(s) would be suitable. Finalise the selection by identifying the valve which can also be supplied with end diameters X to match the bore of the engine air intake hose at the position the valve is to be fitted. Note, end diameters are manufactured to the nearest 1mm. Generally, where more than one valve meets all requirements, select the larger valve size to minimise engine air intake restriction. Valve Selection chart in Metric Units Valve Type D45 D51 D57 D64 D70 D80 Engine Power at rated Speed Kw Naturally Aspirated Engine 7.5 to 38 15 to 54 22 to 72 30 to 93 40 to 120 50 to 179 Turbocharged Engine 7.5 to 32 15 to 45 22 to 60 30 to 78 40 to 100 50 to 149 Engine Air Intake Hose Bore mm Minimum 40 51 57 63 70 70 Maximum 70 80 83 96 102 108 Valve Selection chart in Non-metric Units Valve Type Engine Power at rated Speed hp Naturally Aspirated Engine Turbocharged Engine Engine Air Intake Hose Bore inches Minimum Maximum D45 10 to 50 10 to 42 1 9 / 16 2 3 / 4 D51 20 to 72 20 to 60 2 3 1 / 8 D57 30 to 97 30 to 80 2 1 / 4 3 1 / 4 D64 40 to 125 40 to 104 2 1 / 2 3 3 / 4 D70 54 to 161 54 to 134 2 3 / 4 4 D80 67 to 240 67 to 200 2 3 / 4 4 1 / 4 Engine power is obtained using mathematical calculations for standard applications. Air velocity may vary by intake hose configurations. Valves should be sized as close to the middle of the range as possible. T: +44 (0) 1284 715739 sales@chalwyn.co.uk D SERIES -Bendix Types AUTOMATIC ENGINE OVERSPEED VALVE 3 204 (12)

FITTING 1. The Chalwyn valve is designed for fitting as close to the engine air intake manifold as possible. Where an engine air intake flametrap is also fitted, the Chalwyn valve must always be positioned on the upstream (air cleaner) side of the flametrap. These same requirements are generally applicable to both naturally aspirated and turbocharged engines but for the case of a turbocharged engine the following may be applicable. a) Insufficient space to fit between the turbocharger and engine. In this case the valve may be fitted upstream of the turbocharger. b) The turbocharger air outlet temperature is exceptionally high (200 o c plus). In this case fit the valve downstream of the intercooler or upstream of the turbocharger. 2. Where more than one Chalwyn valve is fitted to an engine as in the case of an engine with multiple intake pipes, a balance pipe arrangement must be installed to connect the various intake pipes together downstream (engine side) of the shut down valves. Typically balance pipe diameters should be about 30% of the diameter of the intake pipes. 3. When fitting, ensure the direction of air flow is in compliance with direction indicated on the body. D70 and D80 valves may be fitted in any attitude. The other valves in this family must be fitted such that the air flow is between vertically down and horizontal. 4. The flexible cuffs at the inlet and outlet of the valve should be of a re-inforced type, provide adequate support for the valve and prevent excessive vibration. If necessary, additional support brackets mounted from the engine should be considered. 5. Particular care must be taken to ensure the integrity of the intake pipework between the Chalwyn valve and intake manifold. Ideally metal pipework should be used and any gaps kept as short as possible, (taking into account any relative movement), and closed by re-inforced hose. The possibility of a hose collapse on closure of the shut down valve should be avoided. 6. Any engine crankcase breather connections into the intake system between the Chalwyn valve and engine or any internal crankcase breather arrangement venting directly into the engine intake ports must be sealed and replaced by an external breather system venting either to atmosphere or to the intake system upstream of the shut down valve. External breather system kits for various engine types are available from Chalwyn. 4 D SERIES -Bendix Types AUTOMATIC ENGINE OVERSPEED VALVES T: +44 (0)1284 715739 204 (12) Sales@chalwyn.co.uk

ADJUSTMENT Once the Chalwyn valve is installed, adjustment of the overspeed trip setting is carried out using the adjuster and locknut (refer to diagram). Basically rotating the adjuster clockwise will increase the engine speed at which automatic shut down occurs. As supplied, the valve will be adjusted such that shut down will generally occur well below the engine high idle speed. To increase the shut down speed to the required setting proceed as follows:- 1. Start engine. Slowly accelerate. Note speed at which shut down occurs. 2. Remove hose at air inlet to Chalwyn valve to expose the adjuster and locknut (see diagram). 3. Release locknut. Turn adjuster clockwise one turn. Tighten locknut. 4. Refit inlet hose to Chalwyn valve. 5. Start engine. Slowly accelerate. Note speed at which shut down occurs. 6. Repeat the above steps 2 to 5 until the first setting at which the engine does not shut down at high idle speed (i.e. maximum throttle, no load). Then either: a) Use the results of shut down speed versus adjuster setting as a calibration check to make a final adjustment to give the required setting (typically 10% to 15% over high idle). or b) If a very precise setting is not required, turn the adjuster a further one turn clockwise to take the shut down above high idle speed by a suitable margin. When using this setting procedure it may be found that the engine occasionally shuts down during the normal operation. If so, turn the adjuster clockwise by a further one half turn. 7. Ensure the adjuster locknut is fully tightened. (Use a thread lock adhesive on the locknut threads). Notes: Turbocharged Engines. When setting up a valve on a turbocharged engine using the preceding method, it may be found that at high power outputs, the engine will shut down at a lower speed than required. If this occurs, further small adjustments in steps of one half turn clockwise should be made until the problem is eliminated. Jammed Valve. If in the course of adjusting the valve it jams on its seat, release by turning CLOCKWISE viewed from adjuster end of valve. T: +44 (0) 1284 715739 sales@chalwyn.co.uk D SERIES -Bendix Types AUTOMATIC ENGINE OVERSPEED VALVE 204 (12) 5

MAINTENANCE Three Monthly: 1. Disconnect intake pipework and release the valve from any support brackets etc. to allow it to be removed. 2. Inspect the valve internally for cleanliness. If necessary, clean in paraffin or white spirit taking normal precautions. Dry the valve thoroughly. 3. Check there is no excessive wear and that the valve moves smoothly over its complete operating stroke. DO NOT LUBRICATE. 4. Refit valve. Check valve setting based on the Adjustment instructions given herein. Important Notes: The three monthly routine maintenance period requirement is dependent on the operating conditions to which the equipment is exposed and, by experience, may need to be varied. Any maintenance problems not covered by the routine maintenance schedule should be discussed with your Chalwyn Distributor before any repair work is undertaken 6 D SERIES -Bendix Types AUTOMATIC ENGINE OVERSPEED VALVES T: +44 (0)1284 715739 204 (12) Sales@chalwyn.co.uk

Americas AMOT - USA Tel: +1 281 940 1800 Fax: +1 713 559 9419 info@amotusa.com Roda Deaco by AMOT - Canada Tel: +1 780 465 4429 Fax: +1 780 469 6275 info@rodadeaco.com Asia Pacific AMOT - China Tel: +86 (0)21 6279 7700 Fax: +86 (0)21 5237 8560 shanghair@amot.com AMOT - Singapore Tel: +65 6408 6265 Fax: +65 6408 6266 singapore@amot.com Europe, Middle East and Africa AMOT - UK Tel: +44 (0)1284 715739 Fax: +44 (0)1284 715747 info@amot.com AMOT - Germany Tel: +49 (0)40 8537 1298 Fax: +49 (0)40 8537 1331 germany@amot.com AMOT - Russia Tel: +7 495 617 12 96 Fax: +7 495 913 97 65 russia@amot.com CHALWYN RESERVES THE RIGHT TO UPDATE THIS PRODUCT SPECIFICATION WITHOUT PRIOR NOTICE.