DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Similar documents
DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Vistop TM isolating switches 63 to 160A

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

K50H004UP cam changeover switch - 4-pole A - screw mounting

DPX moulded case circuit breakers

Cat N 3. OVERALL DIMENSIONS

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

DPX Magnetic only

Euroload Changeover Switch

Essential equipment for all your requirements

COMPLETE SOLUTIONS FOR POWER PROTECTION

DX³ RCCBs - ID 4P up to 100 A

Changeover & Bypass Sw it ches

DPX earth leakage DPX 3 -I earth leakage

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

25A 25A 32A 40A 40A 63A 63A 80A

K30H001YP cam star-delta switch - 3-pole A - screw mounting

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

XL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A

Industrial Contactors CTX 3 3P 185A - 800A

DPX 1600 Electronic release

Phase + Neutral, neutral on right side


Thermal magnetic and trip-free switches

CATALOGUE SPARE PARTS AND RETROFIT KITS FOR AIR CIRCUIT BREAKERS AND TRIP FREE SWITCHES

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Phase + Neutral, neutral on left side

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

cor Long Run Experience

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Low Voltage. Interpact. Switch-disconnectors INS/INV40 to 2500 A. Catalogue 2011

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

TX³ RCCBs 2P up to 100 A

DPX 630 Electronic release

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

AF40... AF96 3-pole contactors Technical data

K50F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

DRX 125 Circuit breaker (not adjustable)

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

DX³ 4-pole RCBO 6000 A/10 ka

Switch disconnectors

up to 63 A (1 module per pole)

Modular contactors and relays

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

(1,5 modules per pole)

DMX 3 -I 2500 switch disconnectors

Switch Disconnectors

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

DRX 100 B/N/H Circuit breaker (not adjustable)

Motorized switch-disconnectors OTM 40 to 125 Amperes

SIRCO M and MV Universal load break switches from 16 to 160 A

Contents. Volume 5 Motor Control and Protection CA E December

SWITCH FUSES 3KL71 from 32A to 800A Description

DRX 250 B/N/H Circuit breaker (not adjustable)

DX³ RCBO 6000A Phase + Neutral, neutral on left

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions

RX 3 M.C.B A up to 63 A

Power protection solutions

An innovative technology

MANUALLY OPERATED CHANGEOVER SWITCHES

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

DPX Electronic + earth leakage

DX³ RCBO 6000A Phase + Neutral, neutral on right

SIRCO PV IEC Load break switches for photovoltaic applications from 100 to 3200 A, up to 1500 VDC

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

500V / V /

Switches disconnectors with fuse-holders. XNF series TF series

DX³ RCBO 6000 A Phase + Neutral, neutral right side

RX 3 M.C.B A up to 63 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Cylindrical fuse-link

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

Fuse switch disconnectors

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

PowerLine Switch Fuses OESA_PL, A. Contents: Technical data... 9/2. Ordering information DIN-pattern... 9/3 BS-pattern...

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

Panel Mount Switches

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

D509E. Manual Motor - Starters

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Safety rope switches with reset for emergency stop

Transcription:

DCX-M changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

FOR COMMERCIAL BUILDINGS AND DCX-M In = 63 A Quality & design CONFORM TO EN/IEC 60947-3 The new DCX-M range of changeover switches has been designed according to IEC 60947-3 standard for its use in low voltage installations for commercial and industrial buildings. Compact design allows space saving inside electrical switchboard.

A replacement power supply always available The new range meets the requirements of manual supply invertors for transfers between the main supply and the alternative supply. A wide range accessories * Direct handles External handles Extended shafts Locking devices Auxiliary contacts Bridging links Main supply G Alternative supply Protective plates Mounting kits for integration into XL³ enclosures *For details see attached catalogue pages In = 160 A In = 250 A In = 630 A A complete range of changeover switches from 63 to 1600 A - 3P and 3P+E Size 1 Size 2 Size 3 Size 4 Size 5 Size 6 200 A 100 A 250 A 40 A 125 A 315 A 630 A 1000 A 63 A 160 A 400 A 800 A 1250 A 1600 A Cage terminals Lugs Lugs Lugs Lugs Lugs WWW.LEGRAND.COM 1

INDUSTRIAL BUILDINGS DCX-M Safety, reliability & flexibility EXCELLENT BEHAVIOUR IN ANY SITUATION 2 DCX-M range offers a high level of security and reliability particularly adapted for the most demanding environments and guaranteed by its electrical and mechanical performance.

Advanced switched neutral pole (early make - late break) Moulded case with frame parts of non - flammable fibre glass reinforced polyester with high mechanical and electrical track resistance and with low water absorption Clear marking of the handle position ensuring safety of the operator (on the front panel of the switch or on the external handle) Front operation with direct or external handle (on the switchboard door) Cage terminals for Size 1 switches and connection with lugs for Size 2 to 6 Visible contact indication via a window in the switch case Standard extended shaft included with the external handle. All type off handles are padlockable in OFF (O) position DCX-M switches can handle any situation in electrical circuits without any risk for the operator: Excellent thermal and dielectric properties of insulating materials adjacent to current - carrying parts: Dielectric strength, electrical track resistance and dimensional stability at high temperatures. Knife - type contacts with self - wiping action on the contact surfaces, providing: Increased contact pressure under heavy starting currents or with short - circuit conditions Shock and vibration proof contacts. On - Load switching of AC (inductive an capacitive) and DC (size 1 and 2 switches) loads up to 1000 V. Rated breaking current of up to 8 times the rated operational current and high making and withstanding currents: short circuit currents Up to 100 ka Uninterrupted duties in extreme temperature conditions as well as the polluted environment of any industrial process. WWW.LEGRAND.COM 3

DCX-M changeover switches from 40 to 1600 A 4 311 21 4 311 24 4 311 26 4 311 29 Technical characteristics p. 8 to 13 Conform to EC EN 60947-3 Moulded case design with frame parts of non - flammable glass fibre reinforced polyester with high mechanical and electrical track resistance and with low water absorption Knife - type contacts with self - wiping action on the contact surfaces, providing: - under heavy starting currents or with short - circuit conditions, the contact pressure is increased - shock and vibration proof contacts Four breaking points per pole with two double - break contacts Pack Cat.Nos Changeover switches 3P 3P+N Size 1 Cage terminals Handle Intensity position 1 4 311 00 4 311 20 40 A I - O - II 1 4 311 01 4 311 21 63 A I - O - II Size 2 Connection with lugs 1 4 311 02 4 311 22 100 A I - O - II 1 4 311 03 4 311 23 125 A I - O - II 1 4 311 04 4 311 24 160 A I - O - II Size 3 Connection with lugs 1 4 311 05 4 311 25 200 A I - O - II 1 4 311 06 4 311 26 250 A I - O - II 1 4 311 07 4 311 27 315 A I - O - II 1 4 311 08 4 311 28 400 A I - O - II Connection OUT Pack Cat.Nos Changeover switches (continued) 3P 3P+N Size 5 Connection with lugs Handle Intensity position 1 4 311 11 4 311 31 1000 A I - O - II 1 4 311 12 4 311 32 1250 A I - O - II Size 6 Connection with lugs 1 4 311 13 4 311 33 1600 A I - O - II Connection OUT Size 4 Connection with lugs 1 4 311 09 4 311 29 630 A I - O - II 1 4 311 10 4 311 30 800 A I - O - II OUT 4

DCX-M changeover switches auxiliaries and accessories 4 311 40 4 311 42 4 311 55 4 311 60 4 311 61 Pack Cat.Nos Direct handles Black rotary handles 1 4 311 45 For DCX-M between 40 A and 160 A 1 4 311 46 For DCX-M between 200 A and 400 A 1 4 311 47 For DCX-M 630 A and 800 A 1 4 311 48 For DCX-M 1000 A and 1250 A 1 4 311 49 For DCX-M 1600 A External handles Black rotary handles Supplied with standard rod 1 4 311 40 For DCX-M between 40 A and 160 A 1 4 311 41 For DCX-M between 200 A and 400 A 1 4 311 42 For DCX-M 630 A and 800 A 1 4 311 43 For DCX-M 1000 A and 1250 A 1 4 311 44 For DCX-M 1600 A Extended shafts Replace the standard rods supplied with the external handles, when required by the door distance 1 4 311 50 For DCX-M between 40 A and 160 A 1 4 311 51 For DCX-M between 200 A and 400 A 1 4 311 52 For DCX-M 630 A and 800 A 1 4 311 53 For DCX-M 1000 A and 1250 A Safety key lock devices Simple lock devices 1 4 311 70 For DCX-M between 40 A and 160 A 1 4 311 71 For DCX-M between 200 A and 400 A 1 4 311 72 For DCX-M 630 A and 800 A 1 4 311 73 For DCX-M 1000 A and 1250 A 1 4 311 74 For DCX-M 1600 A Double lock devices 1 4 311 75 For DCX-M between 40 A and 160 A 1 4 311 76 For DCX-M between 200 A and 400 A 1 4 311 77 For DCX-M 630 A and 800 A 1 4 311 78 For DCX-M 1000 A and 1250 A 1 4 311 79 For DCX-M 1600 A Pack Cat.Nos Auxiliary contacts For DCX-M between 40 and 1250 A 1 4 311 55 1 NO + 1 NC 1 4 311 56 2 NO + 2 NC For DCX-M 1600 A 1 4 311 57 1 NO + 1 NC 1 4 311 58 2 NO + 2 NC Bridging links 1 4 311 60 For DCX-M 40 A and 63 A 1 4 311 61 For DCX-M 100 A and 125 A 1 4 311 62 For DCX-M 1600 A Rear protective plates 1 4 311 65 For DCX-M between 200 A and 400 A 1 4 311 66 For DCX-M 630 A and 800 A 1 4 311 67 For DCX-M 1000 A and 1250 A Mounting kits for DCX-M Kit comprising plate and faceplate for fixing DCX-M For vertical mounting in XL 3 800 and XL 3 4000 enclosures 1 0 211 20 For DCX-M 40 A and 63 A 1 0 211 21 For DCX-M 100 A and 160 A 1 0 211 22 For DCX-M 200 A and 400 A For horizontal mounting in XL 3 800 and XL 3 4000 enclosures 1 0 211 27 For DCX-M 100 A and 160 A 1 0 211 28 For DCX-M 200 A and 400 A For vertical mounting in XL 3 4000 enclosures 1 0 211 23 For DCX-M 630 A and 800 A 1 0 211 24 For DCX-M 1000 A and 1250 A 1 0 211 25 For DCX-M 1600 A For horizontal mounting in XL 3 4000 enclosures 1 0 211 29 For DCX-M 630 A and 800 A 5

DCX-M handles and accessories selection chart Changeover switch I-O-II Direct handle External handle A Size Connection 3P 4P Cat.Nos L (mm) D (mm) 40 1 cage terminals 4 311 00 4 311 20 4 311 45 4 311 40 137 90-180 63 1 cage terminals 4 311 01 4 311 21 4 311 45 4 311 40 137 90-180 100 2 lugs 4 311 02 4 311 22 4 311 45 4 311 40 137 161-250 125 2 lugs 4 311 03 4 311 23 4 311 45 4 311 40 137 161-250 160 2 lugs 4 311 04 4 311 24 4 311 45 4 311 40 137 161-250 200 3 lugs 4 311 05 4 311 25 4 311 46 4 311 41 161 158-254 250 3 lugs 4 311 06 4 311 26 4 311 46 4 311 41 161 158-254 315 3 lugs 4 311 07 4 311 27 4 311 46 4 311 41 161 158-254 400 3 lugs 4 311 08 4 311 28 4 311 46 4 311 41 161 158-254 630 4 lugs 4 311 09 4 311 29 4 311 47 4 311 42 151 187-255 800 4 lugs 4 311 10 4 311 30 4 311 47 4 311 42 151 187-255 1000 5 lugs 4 311 11 4 311 31 4 311 48 4 311 43 125 215-264 1250 5 lugs 4 311 12 4 311 32 4 311 48 4 311 43 125 215-264 1600 6 lugs 4 311 13 4 311 33 4 311 49 4 311 44 204 413-573 6

Auxiliary contacts Bridging links Shaft extensions Rear protective plate Safety lock device 1 NO + 1 NC 2 NO + 2 NC Cat. Nos L (mm) D (mm) Simple Double 4 311 55 4 311 56 4 311 60 4 311 50 187 90-240 - 4 311 70 4 311 75 4 311 55 4 311 56 4 311 60 4 311 50 187 90-240 - 4 311 70 4 311 75 4 311 55 4 311 56 4 311 61 4 311 50 187 161-306 - 4 311 70 4 311 75 4 311 55 4 311 56 4 311 61 4 311 50 187 161-306 - 4 311 70 4 311 75 4 311 55 4 311 56-4 311 50 187 161-306 - 4 311 70 4 311 75 4 311 55 4 311 56-4 311 51 305 158-414 4 311 65 4 311 71 4 311 76 4 311 55 4 311 56-4 311 51 305 158-414 4 311 65 4 311 71 4 311 76 4 311 55 4 311 56-4 311 51 305 158-414 4 311 65 4 311 71 4 311 76 4 311 55 4 311 56-4 311 51 305 158-414 4 311 65 4 311 71 4 311 76 4 311 55 4 311 56-4 311 52 290 187-405 4 311 66 4 311 72 4 311 77 4 311 55 4 311 56-4 311 52 290 187-405 4 311 66 4 311 72 4 311 77 4 311 55 4 311 56-4 311 53 275 215-414 4 311 67 4 311 73 4 311 78 4 311 55 4 311 56-4 311 53 275 215-414 4 311 67 4 311 73 4 311 78 4 311 57 4 311 58 4 311 62 consult us consult us consult us - 4 311 74 4 311 79 7

DCX-M changeover switches dimensions Size 1 3P Cat.Nos 4 311 00/01 and 3P+N Cat.Nos 4 311 20/21 57 28,5 57 24 33 81 33 24 64 75 14 OFF 74 83 57 28,5 57 Ø 4,5 227 Size 2 3P Cat.Nos 4 311 02/03/04 18 91 Ø 10 135 43,6 3 OFF 128 110 84,4 94 Ø 4,5 34 34 14 181 44,8 3 146 3P+N Cat.Nos 4 311 22/23/24 18 91 Ø 10 43,6 135 3 OFF 34 Size 3 3P Cat.Nos 4 311 05/06/07/08 and 3P+N Cat.Nos 4 311 25/26/27/28 119 235 116 Ø 6 42 67 3 3 OFF 25 158 192 216 170 128 110 84,4 44,8 Ø 4,5 34 192 14 44,8 146 3 Ø 10,5 45 88 45 151 8

Size 4 3P Cat.Nos 4 311 09/10 and 3P+N Cat.Nos 4 311 29/30 162 321 159 40 47 5 87 5 Ø 7 OFF 232 282 312 247 Ø 12,5 65 121 65 180 Size 5 3P Cat.Nos 4 311 11/12 and 3P+N Cat.Nos 4 311 31/32 424 210 214 50 57 6 88 6 Ø 9 OFF 295 375 419 315 Ø 14,5 85 163 85 Size 6 3P Cat.No 4 311 13 and 3P+N Cat.No 4 311 33 209 250 200 60 Ø 14,1 60 100 10 Ø 16,2 330 255 330 441 350 310 40 Ø 13 36 100 100 100 551 120 10 342 9

DCX-M direct handles dimensions For DCX-M 40 to 160 A Cat. No 4 311 45 For DCX-M 630 and 800 A Cat. No 4 311 47 50 245 For DCX-M 200 to 400 A Cat. No 4 311 46 For DCX-M 1000 and 1250 A Cat. No 4 311 48 105 35 For DCX-M 1600 A Cat. No 4 311 49 81 81 360 81 360 73,3 10

DCX-M external handles dimensions For DCX-M 40 to 160 A Cat. No 4 311 40 105 max. 15 min. For DCX-M 630 and 800 A Cat. No 4 311 42 75 max. 7 min. 15 50 245 70 13 2,5 41 For DCX-M 200 to 400 A Cat. No 4 311 41 103 max. 7 min. For DCX-M 1000 and 1250 A Cat. No 4 311 43 56 max. 7 min. 15 360 70 105 15 For DCX-M 1600 A Cat. No 4 311 44 238 max. 78 min. 7 70 360 59,5 11

DCX-M technical characteristics Technical characteristics According to IEC / EN 60947-3 40 A 63 A 100 A 125 A 160 A 200 A 250 A Rated thermal current Ith (A) Ambient temperature 40 C 50 63 100 125 160 200 250 50 C 50 63 100 125 160 - - 65 C 35 44 90 90 110 - - Rated thermal current in enclosure Ithe (A) - - - - - 200 250 Rated insulation voltage Ui (V) 800 800 1000 1000 1000 1000 1000 Rated dielectric strength (V) 50 Hz 1 min. 3500 3500 4000 4000 4000 6000 6000 Rated impulse withstand voltage Uimp (kv) 8 8 8 8 8 8 8 AC rated operational current (1) at 50/60 Hz Ie (A) DC rated operational current (2) Ie (A) 400 V 500 V 690 V AC21A 50 63 100 125 160 200 250 AC22A 50 63 100 125 160 200 250 AC23A 50 63 100 125 160 160 180 AC21A 50 63 100 125 160 200 250 AC22A 50 63 100 125 160 200 250 AC23A 40 50 80 100 125 125 150 AC20A 50 63 100 125 160 - - AC21A 50 63 100 125 160 200 250 AC22A 40 50 100 100 125 160 200 AC23A 25 32 60 80 80 80 100 800 V AC20A - - 100 125 160 200 250 1000 V AC20A - - 100 125 160 - - 48 V DC23A (II) 80 100 200 200 200 - - 110 V 230 V 400 V DC21A (II) 63 63 160 160 160 - - DC23A (I) 40 63 100 125 160 - - DC21A (I) 40 63 100 125 160 - - DC23A (I) 40 63 100 125 125 - - DC21A (I) 20 25 50 63 63 - - DC23A (I) - - - - - - - DC20A (II) 80 125 200 250 250 - - 500 V DC23A (I) - - - - - - - 3 x 230 V AC23A 15.9 20 31.5 39.8 50.9 - - AC rated operational 3 x 400 V AC23A 27.7 34.9 54.7 69.2 88.6 80 90 power (3) Pe (kw) 3 x 500 V AC23A 27.7 34.6 61.6 69.2 88.6 78 94 3 x 690 V AC23A 23.9 30.5 56.6 76.4 76.4 69 86 Rated capacitor power (kvar) 400 V 22.5 28.3 45 56.2 72 83 104 Rated breaking capacity (A) 400 V AC23 400 504 800 1000 1280 1280 1440 Rated making capacity (A) 400 V AC23 500 630 1000 1250 1600 1600 1800 Short-circuit behaviour 63 A 63 A 100 A 125 A 160 A 200 A 250 A Short - circuit making capacity (4) - peak value Icm (ka) 5 5 13 13 13 12 12 Short - time withstand current - 1 sec Icw (ka ms) 3 3 7 7 7 8 8 Conditional short - circuit current rms value (5) (ka ms) 100 100 100 100 100 - - Maximum cut - off current (peak value) 10 10 17 17 20 - - Maximum power dissipation I²t (A 2 /s x 10 3 ) 54.7 54.7 55 55 198 - - Minimum number of mechanical operations (6) (Cycles) 30000 30000 30000 30000 30000 10000 10000 Minimum number of electrical operations (6) AC23 1500 1500 1000 1000 1000 - - 400 V (Cycles) AC22A - - - - - 1000 1000 3 P 0.8 0.8 1.8 1.8 1.8 4.8 4.8 Maximum weight (kg) 4 P 0.8 0.8 2 2 2 5.3 5.3 Connecting capacity 40 A 63 A 100 A 125 A 160 A 200 A 250 A Rigid cable Cu mm² 25 25 95 95 95 240 240 Bar Thickness / Wid mm - - 5 / 25 5 / 25 5 / 25 2 x 5 / 30 2 x 5 / 30 Tightening torque Nm 2 2 4 / 13 4 / 13 4 / 13 24 24 1: Other voltages and / or utilization categories: please consult us 2: For series (I) or Parallel (II) connection of 4P switches, see diagrams 3: Indicative values: current values vary from one motor manufacturer to another 4: Without limiting protective device (short - circuit maintained 50... 100 ms) 5: With a protective device limiting the cut - off current and the joule integral to the indicated values 6: Please consult us for more operations 7: Rated operational current AC22B 12

315 A 400 A 630 A 800 A 1000 A 1250 A 1600 A 315 400 630 800 1000 1250 1600 - - - - - - 1600 - - - - - - 1600 315 400 630 800 1000 1250-1000 1000 1000 1000 1000 1000 1000 6000 6000 8000 8000 8000 8000 10000 8 8 12 12 12 12 12 315 400 630 800 1000 1250 1600 315 (7) 400 (7) 630 800 (7) 1000 1250 (7) 1600 200 250 500 630 1000 1250 1000 315 400 630 800 1000 1250 1600 315 400 (7) 630 800 (7) 1000 1250 (7) 1250 160 200 315 400 800 1000 900 - - - - - - 1600 315 400 630 800 1000 1250 1600 250 315 (7) 500 630 (7) 800 1000 (7) 1000 125 160 250 315 630 800 630 315 400 630 800 1000 1250 1600 - - 630 800 1000 1250 1600 - - - - - - 2000 - - - - - - 1600 - - - - - - 1600 - - - - - - 1600 - - - - - - 1000 - - - - - - 1600 - - - - - - 800 - - - - - - 2500 - - - - - - 800 - - - - - - 318.6 100 125 250 315 501 626 554.2 100 125 197 250 501 626 623.5 108 138 216 272 544 691 602.3 131 166 262 333 416 520 450.3 1600 2000 4000 4000 8000 10000 8000 2000 2500 5000 5000 10000 12500 10000 Series connection of 4P switches up to up to 160 A (DC) I - + + - + + - - Parallel connection of 4P switches up to up to 160 A (DC) + II + - - 315 A 400 A 630 A 800 A 1000 A 1250 A 1600 A 12 12 20 20 32 32 75 8 8 13 13 25 25 50 - - - - - - - - - - - - - - - - - - - - - 10000 10000 10000 10000 10000 10000 10000 - - - - - - 500 1000 200 (7) 1000 100 (7) 500 100 (7) 5 5 11.5 11.9 22.5 24.3 42.9 5.5 5.5 12.6 13.2 25 27.3 47.3 315 A 400 A 630 A 800 A 1000 A 1250 A 1600 A 240 240 2 x 240 2 x 240 - - - 2 x 5 / 30 2 x 5 / 30 2 x 6 / 45 2 x 6 / 45 2 x 10 / 60 2 x 10 / 60 2 x 7 / 80 24 24 45 45 55 55 55