Installation and User Guide CCMS312

Similar documents
Charge your future! The emh1: Our wallbox for your electric vehicle

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

CAN-Translator. User s guide

Owner s Manual. Advanced Wind/Solar Hybrid (Street Light) Controller

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Heat Meter Integrator

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

USERS MANUAL MCD REMOTE OPERATOR

GS2 Series - Introduction

MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35

Automated Precision Weighing

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

ET9500 BEMS Interface Box Configuration Guide

1.0 Features and Description

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

CONA -control Monitoring system for steam traps

Parker Hannifin GmbH & Co. KG Tube Fittings Division Europe Am Metallwerk 9, Bielefeld Phone Fax

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Advanced Battery Charger. 3 - stage charging capability (IUoU) 25A

PowerJet Sequential Injection INDEX. 1 Introduction 1.1 Features of the Software. 2- Software installation

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

Installation Guide B-BOX Pro2.5 ~ 10.0

INDEX 1 Introduction 2- Software installation 3 Open the program 4 General - F2 5 Configuration - F3 6 - Calibration - F5 7 Model - F6 8 - Map - F7

Instruction of connection and programming of the VECTOR controller

CORNERING LIGHTING MODULE CLM02-CAN INSTALLATION MANUAL

PDC PROPELLER DE-ICE CONTROLLER

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

LPG STARTBOX. Instruction Manual. Rempel Power Systems GmbH

TachoDrive key + TachoDrive Express software

MICROPROCESSOR BASED CONTROLLER

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

INDEX. 1.Safety Precautions and Warnings...3

Orica Seismic Electronic Initiation System OSEIS TESTER. Manual

Flight Systems. Replacement for KASSEC DESCRIPTION

IB IL 24 SEG/F. Function. INTERBUS Inline Segment Terminal With Fuse. Data Sheet 5656B

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

X11CA-IM MASTER MODULE

80V 300Ah Lithium-ion Battery Pack Data Sheet

MICROMAT-F / MINIMAT-F SCREWDRIVING SYSTEM

DKG-109 AUTOMATIC MAINS FAILURE UNIT

SP PRO KACO Managed AC Coupling

SPEEDRIVE INSTRUCTIONS MANUAL

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Water Specialist PR Control Valve Programming and Cover Drawing Manual

LAMBDA SENSOR CONTROLLER

Automated Precision Weighing

Operating Instructions

Important instructions

TAROT ZYX-S2 Three-axis Gyro User Manual

Wallbox. emh1. with charging cable. Instruction Manual VERSION: EMH1-5X1/5X ARTICLE NO.:

Repair instructions UNIVERSAL 320 UNIVERSAL 320 R Andreas Hettich GmbH & Co. KG AR1401EN

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Brushed. Brushed. Brushed Motor

Automatic Gear Shaft Control GSW2001. Automation system for shifting and testing of vehicle gearboxes directly at the selector shaft

Installation instructions. Adapter AD 01 AD 02 AD 03

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Note: If anything is damaged or missing, contact your customer representative immediately.

Continental Hydraulics Installation Manual CEM-AA-A

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

Operating Instructions Control 330 Conductivity meter

Digital Hand Controller. Manual

Manual. Lynx Ion 24V/180Ah Lithium Ion Batteries

EV Charge Control Standard-compliant control of the Control Pilot and Proximity Plug interfaces between the electric vehicle and charging station

photovoltaikforum.com

User Manual Rittal PMC UPS 6kVA

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

SP PRO ABB Managed AC Coupling

SPG-DIGI. Operating Instruction. Please read carefully before use!

QUANTUM LX CONTROL PANEL

Cable Duct AS-i 3.0 Motor Modules

Positive displacement batch controller

Operating Instructions

EPS/ELA-Series User Manual EPS/ELA 250W

BMS24. Thanks for your purchasing the BMS24 for your vehicle.

PLUS PLUS & PRO. Installation manual

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

All In one uninterruptible power supply solutions

Quick Installation Guide for X50 Plus Car OBD Multi-function instrument Product introductions

Operating instruction and technical description

Excel 10 W7751H3007 VAV ACTUATOR

Atlas 5. Instruction Manual. Handheld Indoor Air Quality Monitor. Measures CO2, Temperature and Humidity DISTRIBUTED BY

BRAKE TESTER DECELEROMETER

Off Grid Solar Inverter. LVS 50M User Manual

JUMO digiline ORP. Intelligent electronics with digital interface or analog output for redox sensors. Operating Manual T90Z001K000

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

OV4 Installation Manual

MODEL: PSN3. Final Control Elements. STROKE 6: 0 to 60 mm (0 to 2.36 )

Application. Battery. Public Grid GS HYBRID INVERTER

Thermal flow sensor TFS-35

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Transcription:

SEITE 1 Installation and User Guide CCMS312 Description The charging current management system CCMS312 is used as a control unit for up to 8 emh1 (EVCC). Functions of the CCMS312: Simple load management equal distribution of the maximum current I m,that can be provided by upstream infrastructure to the requesting emh1 Display and change the maximum current I m Display the actual charging current I a for each emh1 Display the status of the connected emh1 CCMS312 includes: LC display with 3 lines of 16 characters 6 functional buttons two RJ12-headers as RS485-communication interface a 12V supply terminal two network cables LOMK130 one supply cable LOMK430 Technical data Power supply PWR Header MOLEX MiniFit JR 5569 2pol. Rated voltage 12V= (9.0 30.0V) Rated current 40mA Max. length of cable 3m Fuse 750mA slow blow onboard (non-replaceable) Serial RS485 interface Header 2x RJ12 Data rate 38.4kBd, 8 data bit, 1 stop bit, no parity Max. length of cable 10m per segment Max. number of bus nodes 10 (1x CCMS312, 8x emh1, 1x PC or equiv.) Each emh1 requires a unique address! Use 120Ωresistor to terminate both ends of the network, if necessary! Ambient temperature (storage) -30 85 C Ambient temperature (operation) -25 55 C Relative humidity IP rating 10 90% no condensation IP20 Declaration of conformity CCMS312 is marked with the CE-tag. Corresponding declaration of conformity is available on request at Bayerische Elektrozubehör GmbH & Co. KG or as download at www.abl-sursum.com

SEITE 2 Dimensions Assembly Assembly is done by 4 screws Ø4.5 mm on a stable and even surface Strain relief must be provided externally Power is supplied via a separate power adapter Terminal assignment Pin X2/3 (RS485) 1 M (GND485) 2 M (GND485) 3 A 4 B 5 M (GND485) 6 RESET Pin X1 (Power) 1 +12V 2 M (GND) GND and GND485 are connected via a 100 Ohm resistor. RS485-Network emh1 #1 emh1 #2 emh1 #3 CCMS312 emh1 #4 emh1 #5 emh1 #6 emh1 #7 emh1 #8 12V DC LOMK430 e.g. LOMK130 120 optional 120 The sequence of emh1 and CCMS312 is not relevant. Linear wiring of the RS485-network is mandatory. Tree and star topologies must not be used!

SEITE 3 Setup Step To do 1 All emh1 must have a firmware for charging current management systems emh1 with charging socket: V2.7 or higher emh1 with charging cable: V5.3 or higher 2 Setup unique CCMS address for each emh1 Setting address of emh1 can be done using the user software EVCC_Set_I (V1.1 or higher) 3 Connection and fixture of network-cables 4 Connect CCMS312 to power-supply using LOMK430 and switch on power-supply 5 Set maximum current I m and password. 6 Functional test (all emh1 detected?) Display Main Display Password query Setting contrast Setting I m Setting Password Confirmation I m Explanation of buttons Button to the left Button to the right Button to bottom Button to top ESC Button Escape Button Enter If a button is not listed in the following description of functions, no function is provided for that button in this mode! Basic functions in each window: Push ESC Main Display No button pushed within 1 minute Main Display Test Mode By simultaneously pushing ESC and while switching on the power-supply the stored emh1 are deleted and the Test-Mode is activated: 1. Display is colored black to identify possible pixel errors 2. Push to continue test; corresponding message is shown; Test-Mode is terminated by any other button 3. Push,, and separately; corresponding message is shown 4. Push ESC to change contrast of display

SEITE 4 Main Display In the Main Display the maximum current I m, that can be provided by upstream infrastructure, the actual maximum charging current of each emh1 (I a ) and the status of the emh1 are displayed. I m : x x x A 1 2 3 4 5 6 7 8 I a : y y A z z z z z z z z xxx := I m; yy := I a ; z:= Status emh1 z Function Description - NONEXISTANT emh1 not stored * OFFLINE emh1 stored but not detected A OFF State A: Standby emh1 W WAIT State B1: EV detected, not enabled by CCMS312 B EVFOUND State B2: EV detected; waiting for request for charging by EV or charging stopped/interrupted by EV C CHARGE State C: Request for charging by EV E ERROR State E: Error emh1 U UNKNOWN Unknown state received from emh1 M MANUAL emh1 in Manual-(Service-)Mode I IDLE emh1 deactivated by CCMS312. If the emh1 is in state B for more than 30 minutes, it is deactivated for 15 minutes to maximize I a for remaining emh1 Actual maximum charging current per emh1 (I a ) is calculated as following: I a = I m /N I m := current, that can be provided by upstream infrastructure N := Number of emh1 in state W, B or C I a is round down to following values automatically: 0A, 6A, 7A, 8A, 9A, 10A, 11A, 12A, 13A, 14A, 15A, 16A, 18A, 20A, 22A, 24A, 26A, 28A, 30A, 32A If an additional emh1 enters state W, I a is recalculated: I a 6A all emh1 are adjusted to new I a ; the additional emh1 is enabled (status B) I a <6A all emh1 keep old I a ; the additional emh1 is not enabled (Status W). W flashes for that emh1, that will be enabled first, if possible Example (I m = 22A): 1. EV connected to emh1 #3 (Status W) 1. Recalculate I a : 22A/1 = 22A I a = 22A 3. Enable #3 (Status B resp. C) 2. EV connected to emh1 #5 (Status W) 1. Recalculate I a : 22A/2 = 11A I a = 11A 3. Enable #5 (Status B resp. C) 3. EV connected to emh1 #2 (Status W) 1. Recalculate I a : 22A/3 = 7,33A I a = 7A 3. Enable #2 (Status B resp. C) 4. EV connected to emh1 #7 (Status W) 1. Recalculate I a : 22A/4 = 5,5A<6A (!) I a = 7A 2. #7 not enabled (Status W flashing) 5. EV connected to emh1 #4 (Status W) 1. Recalculate I a : 22A/4 = 5,5A<6A (!) I a = 7A 2. #4 not enabled (Status W) 6. EV disconnected from emh1 #3 (Status A) 1. Recalculate I a : 22A/4 = 5,5A<6A (!) I a = 7A 3. After 10s #7 is enabled (Status B resp. C) 4. #4 not enabled (Status W flashing)

SEITE 5 Password query To enter function (main display) push button To make changes, the correct password must be entered in the password query. P A S S W O R D ********: 8 character password When shipped, the password is ********., Select a position in the password, the selected digit blinks Capital letters, numbers and the special characters *,?,! and _ can be selected Password is correct Maximum current setting Password is incorrect Main Display Setting Maximum current I m Following values are available for I m : 12A, 14A, 16A, 18A, 20A, 22A, 24A, 26A, 28A, 30A, 32A, 48A, 63A, 70A, 80A, 100A, 125A Due to safety reasons I m must be set twice. I m : x x x A C o n f i r m I m : y y y A xxx: Maximum current yyy: Confirm maximum current I m : Contrast setting Confirm I m : I m : I m : Confirm I m : Confirm I m : Password change Increase value Decrease value I m = Confirm I m Maximum current confirmation

SEITE 6 Confirmation maximum current For safety reasons, I m must be confirmed again in the maximum current confirmation. C o n f i r m I m : x x x A y y y y y xxx: Maximum current yyyyy: Confirmation NO or YES Button functions maximum current confirmation: Toggle between NO and YES NO Maximum current setting YES Accept maximum current Main Display Setting contrast C o n t r a s t : k k kk: Contrast value Change contrast Accept new contrast Main Display ESC Restore old contrast Main Display Password change Via the password change a new password can be set. P W 1 : P W 2 : ********: 8 character password, Select a position in the password, the selected digit blinks Capital letters, numbers and the special characters *,?,! and _ can be selected PW1 = PW2 store new password Main Display To reset the CCMS312 to factory settings a PC / laptop and the program chip45boot2 are required!